-
Frontiers in Physiology 2024Transcatheter aortic valve replacement (TAVR) is a minimally invasive interventional solution for treating aortic stenosis. The complex post-TAVR complications are...
Transcatheter aortic valve replacement (TAVR) is a minimally invasive interventional solution for treating aortic stenosis. The complex post-TAVR complications are associated with the type of valve implanted and the position of the implantation. The study aimed to establish a rapid numerical research method for TAVR to assess the performance differences of self-expanding valves released at various positions. It also aimed to calculate the risks of postoperative paravalvular leak and atrioventricular conduction block, comparing these risks to clinical outcomes to verify the method's effectiveness and accuracy. Based on medical images, six cases were established, including the aortic wall, native valve and calcification; one with a bicuspid aortic valve and five with tricuspid aortic valves. The parameters for the stent materials used by the patients were customized. High strain in the contact area between the stent and the valve annulus may lead to atrioventricular conduction block. Postoperatively, the self-expanding valve maintained a circular cross-section, reducing the risk of paravalvular leak and demonstrating favorable hemodynamic characteristics, consistent with clinical observations. The outcomes of the six simulations showed no significant difference in valve frame morphology or paravalvular leak risk compared to clinical results, thereby validating the numerical simulation process proposed for quickly selecting valve models and optimal release positions, aiding in TAVR preoperative planning based on patients'geometric characteristics.
PubMed: 38903911
DOI: 10.3389/fphys.2024.1407215 -
Cureus May 2024The decision to assess the severity and determine the ideal timing of intervention for low-gradient aortic stenosis poses a greater challenge. Recently, a novel method...
PURPOSE
The decision to assess the severity and determine the ideal timing of intervention for low-gradient aortic stenosis poses a greater challenge. Recently, a novel method for determining the flow status of patients with aortic stenosis has been introduced, utilizing flow rate measurements. In this study, we investigated whether the flow status of patients with low-gradient aortic stenosis is linked to mortality within a three-year timeframe.
METHODS
Twenty-nine patients diagnosed with low-gradient aortic stenosis and valve area ≤ 1 cm were identified during 2010-2015. Each patient's flow rate across the aortic valve was computed, and the study scrutinized echocardiographic parameters to ascertain their correlation with mortality over a three-year timeframe.
RESULTS
We observed that among patients with low-gradient aortic stenosis and a valve area of ≤1 cm, a decreased flow rate across the aortic valve emerged as an independent predictor of mortality. A flow rate < 210 ml/s was linked with a three-year mortality rate of 66.7%, whereas a low stroke volume index < 35 ml/m² did not show an association with three-year mortality. This observation might be attributed to the smaller body sizes prevalent among these older patients, particularly females, which could influence the calculation of the stroke volume index.
CONCLUSION
In older patients with low-gradient aortic stenosis, the flow rate can better reflect flow status than the stroke volume index, and it also suggests a prognostic significance in predicting mortality. Additional studies are warranted to validate these findings across broader patient populations and to assess the potential efficacy of early intervention strategies in this particular patient cohort.
PubMed: 38903309
DOI: 10.7759/cureus.60776 -
Journal of Cardiothoracic Surgery Jun 2024The aim of this study is to report the preliminary real-word clinical and hemodynamic performance from the MANTRA study in patients undergoing aortic valve replacement...
BACKGROUND
The aim of this study is to report the preliminary real-word clinical and hemodynamic performance from the MANTRA study in patients undergoing aortic valve replacement with Perceval PLUS sutureless valve.
METHODS
MANTRA is an ongoing "umbrella" prospective, multi-center, international post-market study to collect real-life safety and performance data on Corcym devices (Corcym S.r.l, Saluggia, Italy). Clinical and echocardiographic outcomes were collected preoperatively, at discharge and at each follow up. KCCQ-12 and EQ-5D-5L quality of life questionnaires were collected preoperatively and at 30-days.
RESULTS
A total of 328 patients underwent aortic valve replacement with Perceval PLUS in 29 International institutions. Patients were enrolled from July 2021 to October 2023 and enrollment is still ongoing. Mean age was 71.9 ± 6.4 years, mean EuroSCORE II was 2.9 ± 3.9. Minimally invasive approach was performed in 44.2% (145/328) of patients; concomitant procedures were done in 40.8% (134/328) of cases. Thirty-day mortality was 1.8% (6/328) and no re-interventions were reported. Pacemaker implant was required in 4.0% (13/328) of the patients. The assessment of the functional status demonstrated marked and stable improvement in NYHA class in most patients at 30-day follow-up, with significant increase of KCCQ-12 summary score (from 58.8 ± 23.0 to 71.8 ± 22.1, p < 0.0001) and EQ-5D-5L VAS score (from 64.5 ± 20.4 to 72.6 ± 17.5, p < 0.0001). Mean pressure gradient decreased from 46.2 ± 17.3 mmHg to 10.1 ± 4.7 mmHg at 30-day follow-up. Low or no incidence of moderate-to-severe paravalvular or central leak was reported.
CONCLUSIONS
Preliminary results demonstrate good clinical outcomes and significant improvement of Quality of Life at 30-days, excellent early hemodynamic performance within patient implanted with Perceval PLUS.
TRIAL REGISTRATION
The MANTRA study has been registered in ClinicalTrials.gov (NCT05002543, Initial release 26 July 2021).
Topics: Humans; Aged; Male; Female; Prospective Studies; Heart Valve Prosthesis; Aortic Valve; Heart Valve Prosthesis Implantation; Treatment Outcome; Aortic Valve Stenosis; Prosthesis Design; Sutureless Surgical Procedures; Quality of Life; Hemodynamics; Aged, 80 and over; Middle Aged
PubMed: 38902742
DOI: 10.1186/s13019-024-02861-1 -
BMC Cardiovascular Disorders Jun 2024Previous studies have shown the importance of energy deficiency and malfunctioning mitochondria in the pathophysiology of hypertrophic cardiomyopathy (HCM). There has... (Observational Study)
Observational Study
BACKGROUND
Previous studies have shown the importance of energy deficiency and malfunctioning mitochondria in the pathophysiology of hypertrophic cardiomyopathy (HCM). There has been a little research into the relationship between plasma free fatty acids (FFA), one of the heart's main energy sources, and HCM. We evaluated its clinical importance in HCM to see if there was a link between plasma FFA metabolism and HCM.
METHODS
In a single-center retrospective observational study, we investigated 420 HCM patients diagnosed at Beijing Anzhen Hospital between January 1, 2018, and December 31, 2022. Meanwhile, 1372 individuals without HCM (non-HCM) were recruited. 391 non-HCM patients were chosen as controls via a propensity score matching (PSM) study with a 1:1 ratio.
RESULTS
FFA in HCM patients showed statistically significant correlations with creatinine (r = 0.115, p = 0.023), estimated GFR (r=-0.130, p = 0.010), BNP (r = 0.152, p = 0.007), LVEF (r=-0.227, p < 0.001), LVFS (r=-0.160, p = 0.002), and LAD (r = 0.112, p = 0.028). Higher FFA levels were found in HCM patients who had atrial fibrillation and NYHY functional classes III or IV (p = 0.015 and p = 0.022, respectively). In HCM patients, multiple linear regression analysis revealed that BNP and LVEF had independent relationships with increasing FFA (Standardized = 0.139, p = 0.013 and =-0.196, p < 0.001, respectively).
CONCLUSIONS
Among HCM patients, the plasma FFA concentration was lower, and those with AF and NYHY functional class III or IV had higher FFA levels, and LVEF and BNP were independently associated with increasing FFA. The findings of the study should help inspire future efforts to better understand how energy deficiency contributes to hypertrophic cardiomyopathy (HCM) development.
Topics: Humans; Cardiomyopathy, Hypertrophic; Retrospective Studies; Male; Female; Fatty Acids, Nonesterified; Middle Aged; Biomarkers; Adult; Energy Metabolism; Aged; Ventricular Function, Left; Beijing
PubMed: 38902636
DOI: 10.1186/s12872-024-03925-9 -
Insights Into Imaging Jun 2024Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively... (Review)
Review
Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively employed in place of surgical aortic valve replacement also in intermediate-risk patients. The potential lasting consequences of minor complications, which might have limited impact on elderly patients, could be more noteworthy in the longer term when occurring in younger individuals. That's why a greater focus on early diagnosis, correct management, and prevention of post-procedural complications is key to achieve satisfactory results. ECG-triggered multidetector computed tomography angiography (CTA) is the mainstay imaging modality for pre-procedural planning of TAVI and is also used for post-interventional early detection of both acute and long-term complications. CTA allows detailed morphological analysis of the valve and its movement throughout the entire cardiac cycle. Moreover, stent position, coronary artery branches, and integrity of the aortic root can be precisely evaluated. Imaging reliability implies the correct technical setting of the computed tomography scan, knowledge of valve type, normal post-interventional findings, and awareness of classic and life-threatening complications after a TAVI procedure. This educational review discusses the main post-procedural complications of TAVI with a specific imaging focus, trying to clearly describe the technical aspects of CTA Imaging in post-TAVI and its clinical applications and challenges, with a final focus on future perspectives and emerging technologies. CRITICAL RELEVANCE STATEMENT: This review undertakes an analysis of the role computed tomography angiography (CTA) plays in the assessment of post-TAVI complications. Highlighting the educational issues related to the topic, empowers radiologists to refine their clinical approach, contributing to enhanced patient care. KEY POINTS: Prompt recognition of TAVI complications, ranging from value issues to death, is crucial. Adherence to recommended scanning protocols, and the optimization of tailored protocols, is essential. CTA is central in the diagnosis of TAVI complications and functions as a gatekeeper to treatment.
PubMed: 38900378
DOI: 10.1186/s13244-024-01729-1 -
JTCVS Techniques Jun 2024Aortic valve neocuspidization with autologous pericardium is gaining increasing attention as a surgical treatment option for aortic valve disease. However, little is...
OBJECTIVES
Aortic valve neocuspidization with autologous pericardium is gaining increasing attention as a surgical treatment option for aortic valve disease. However, little is known about midterm durability and valve-related events.
METHODS
Patients undergoing aortic valve neocuspidization between 2016 and 2021 were included. Transthoracic echocardiography was performed before the operation, at discharge, and annually thereafter. Data were analyzed for incidences of structural valve deterioration, bioprosthetic valve failure, survival, freedom from reoperation, and hemodynamic performance.
RESULTS
A total of 162 patients underwent aortic valve neocuspidization (mean age, 52.6 ± 16.6 years; range, 13-78 years); 114 (70.4%) were male. A total of 132 patients presented with a bicuspid aortic valve (81.5%) and 126 patients presented with aortic valve stenosis (77.8%). Concomitant procedures were performed in 63 patients (38.9%). Mean follow-up was 3.5 ± 1.2 years. At discharge, peak and mean pressure gradients were 15.6 ± 7.2 mm Hg and 8.4 ± 3.7 mm Hg, respectively, with a mean effective orifice area of 2.4 ± 0.8 cm. After 5 years, peak and mean pressure gradients were 14.5 ± 4.6 mm Hg and 7.5 ± 2.2 mm Hg, respectively, with a mean effective orifice area of 2.3 ± 0.8 cm. At 5 years, cumulative incidences of moderate and severe structural valve deterioration and bioprosthetic valve failure were 9.82% ± 3.87%, 6.96% ± 3.71%, and 12.1% ± 4.12%, respectively. Survival was 97.3% ± 1.4%, and freedom from reoperation was 91.3% ± 2.4%.
CONCLUSIONS
Aortic valve neocuspidization accomplishes low pressure gradients early after initial surgery and during follow-up. Survival in this young patient population is excellent. The main reason for reoperation is endocarditis, and rates for structural valve degeneration are low.
PubMed: 38899113
DOI: 10.1016/j.xjtc.2024.02.011 -
Arquivos Brasileiros de Cardiologia 2024Transcatheter aortic valve implantation (TAVI) has established itself as the preferential strategy to approach severe aortic stenosis. Information on procedural... (Observational Study)
Observational Study
BACKGROUND
Transcatheter aortic valve implantation (TAVI) has established itself as the preferential strategy to approach severe aortic stenosis. Information on procedural improvements and nationwide results obtained with the technique throughout the past decade are unknown.
OBJECTIVES
To assess the temporal variation of the demographic profile, procedural characteristics, and in-hospital outcomes of patients undergoing TAVI procedures at the Rede D'Or São Luiz.
METHODS
Observational registry comprising 29 national institutions, comparing the characteristics of the TAVI procedures performed from 2012 to 2017 (Group 1) to those performed from 2018 to 2023 (Group 2). The statistical significance level adopted was p < 0.05.
RESULTS
This study assessed 661 patients, 95 in Group 1 and 566 in Group 2, with a mean age of 81.1 years. Group 1 patients had a higher prevalence of New York Heart Association functional class III or IV and STS risk score > 8%. In addition, they more often underwent general anesthesia, transesophageal echocardiographic monitoring, and access through femoral dissection. Group 2 patients had a higher success rate of the TAVI procedure (95.4% versus 89.5%; p = 0.018), lower mortality (3.9% versus 11.6%; p = 0.004), and less often needed permanent pacemaker implantation (8.5% versus 17.9%; p = 0.008).
CONCLUSIONS
The 10-year temporal trends analysis of the TAVIDOR Registry shows a reduction in patients' clinical complexity over time. Furthermore, the advance to minimalistic implantation techniques, added to the technological evolution of the devices, may have contributed to the favorable outcomes observed among those whose implantation occurred in the last 5 years studied.
Topics: Humans; Transcatheter Aortic Valve Replacement; Male; Female; Registries; Aged, 80 and over; Aortic Valve Stenosis; Aged; Treatment Outcome; Time Factors; Risk Factors; Brazil; Hospital Mortality
PubMed: 38896588
DOI: 10.36660/abc.20230467 -
European Heart Journal. Case Reports Jun 2024Unicuspid aortic valve (UAV) represents a rare congenital anomaly characterized by two subtypes: acommissural unicuspid aortic valve and unicommissural unicuspid aortic...
BACKGROUND
Unicuspid aortic valve (UAV) represents a rare congenital anomaly characterized by two subtypes: acommissural unicuspid aortic valve and unicommissural unicuspid aortic valve. Acommissural UAV is often diagnosed and corrected during the neonatal period due to haemodynamic instability. Unicommissural UAV leads to aortic stenosis (AS) in early adulthood. The diagnostic challenge associated with UAV primarily stems from its eccentric orifice opening and valvular calcification, resulting in difficult visualization of the commissures and localization of the orifice plane. This case report aims to demonstrate the unique morphological features of UAV through a comprehensive analysis using multimodality imaging.
CASE SUMMARY
A 61-year-old woman presented to the emergency department for recurrent episodes of dyspnoea. Severe AS was diagnosed on transthoracic echocardiography (TTE) by Doppler haemodynamic measurement. However, follow-up transesophageal echocardiography (TEE) and CT transcatheter aortic valve replacement showed moderate AS by planimetry. Following this, patient was monitored closely, but her dyspnoea kept worsening. Cardiovascular magnetic resonance (CMR) was performed due to persistent dyspnoea, identifying UAV with eccentric loophole orifice with unicommissural attachment and opposite free leaflet edge. The patient was managed medically.
DISCUSSION
TTE is the test of choice for AS that defines valvular morphology by direct visualization and grades the severity by haemodynamic measurement. However, the accuracy of TTE can be limited by poor acoustic windows and heavy valvular calcification. TEE measures aortic valve area (AVA) by planimetry that requires accurate localization of the AV orifice plane. Similarly, it applies to multi-detector computed tomography (MDCT). While CMR is expensive and mainly available in tertiary centres, it can provide additional information when there is discordance.
PubMed: 38895171
DOI: 10.1093/ehjcr/ytae269 -
ESC Heart Failure Jun 2024In low-risk patients with severe aortic stenosis (AS), sutureless surgical aortic valve replacement (SU-SAVR) may be an alternative to transcatheter aortic valve...
AIMS
In low-risk patients with severe aortic stenosis (AS), sutureless surgical aortic valve replacement (SU-SAVR) may be an alternative to transcatheter aortic valve implantation (TAVI). The risk of heart failure hospitalization (HFH) after aortic valve replacement (AVR) in this population is incompletely characterized. This study aims to investigate the incidence, predictors, and outcomes of HFH in patients undergoing SU-SAVR versus TAVI.
METHODS AND RESULTS
Patients referred for AVR between 2013 and 2020 at two centres were consecutively included. The decision for SU-SAVR or TAVI was determined by a multidisciplinary Heart Team. Cox regression and competing risk analysis were conducted to assess adverse events. Of 594 patients (mean age 77.5 ± 6.4, 59.8% male), 424 underwent SU-SAVR, while 170 underwent TAVI. Following a mean follow-up of 34.1 ± 23.1 months, HFH occurred in 112 (27.8%) SU-SAVR patients and in 8 (4.8%) TAVI patients (P < 0.001). The SU-SAVR cohort exhibited higher all-cause mortality (138 [32.5%] patients compared with 30 [17.6%] in the TAVI cohort [P < 0.001]). These differences remained significant after sensitivity analyses with 1:1 propensity score matching for baseline variables. SU-SAVR with HFH was associated with increased all-cause mortality (61.6% vs. 23.1%, P < 0.001). Independent associates of HFH in SU-SAVR patients included diabetes, atrial fibrillation, chronic obstructive pulmonary disease, lower glomerular filtration rate and lower left ventricular ejection fraction. SU-SAVR patients with HFH had a 12-month LVEF of 59.4 ± 12.7.
CONCLUSIONS
In low-risk AS, SU-SAVR is associated with a higher risk of HFH and all-cause mortality compared to TAVI. In patients with severe AS candidate to SU-SAVR or TAVI, TAVI may be the preferred intervention.
PubMed: 38894578
DOI: 10.1002/ehf2.14887 -
Journal of Clinical Medicine May 2024Postoperative cardiovascular complications (either in a hospital or within 30 days after the operation) are among the most common problems with non-cardiac surgeries... (Review)
Review
Postoperative cardiovascular complications (either in a hospital or within 30 days after the operation) are among the most common problems with non-cardiac surgeries (NCSs). Pre-existing cardiac comorbidities add significant risk to the development of such complications. Valvular heart disease (VHD), a rather frequent cardiac comorbidity (especially in the elderly population), can pose serious life-threatening peri-/postoperative complications. Being familiar with the recommended perioperative management of patients with VHD or an implanted prosthetic heart valve who are scheduled for NCS is of great importance in daily clinical practice. Although recently published guidelines by the European Society of Cardiology (ESC) and the American College of Cardiology and American Heart Association (ACC/AHA) for the management of VHD and perioperative management of patients undergoing NCS addresses the mentioned problem, a comprehensive review of the guidelines that provides an easy-to-use summary of the recommendations and their similarities and differences is missing in the published literature. In this review article, we summarize all of the relevant important information based on the latest data published in both guidelines needed for practical decision-making in the perioperative management of patients with VHD or after valvular repair (with prosthetic heart valve) who are scheduled for NCS.
PubMed: 38892948
DOI: 10.3390/jcm13113240