Clinical Ophthalmology (Auckland, N.Z.) 2024To assess long term changes of the surgically induced astigmatism (SIA) and corneal higher-order aberrations (HOAs) after 2.2 mm clear corneal incisions (CCIs) in...
Long Term Evaluation of Surgically Induced Astigmatism and Corneal Higher-Order Aberrations After 2.2 Mm Clear Corneal Incisions in Femtosecond Laser-Assisted Cataract Surgery: Temporal versus Superior Approach.
PURPOSE
To assess long term changes of the surgically induced astigmatism (SIA) and corneal higher-order aberrations (HOAs) after 2.2 mm clear corneal incisions (CCIs) in femtosecond laser-assisted cataract surgery and compare them between 2 types of CCIs: temporal and superior approach.
PATIENTS AND METHODS
Patients received the temporal CCIs (Group A) or the superior CCIs (Group B). Outcome measures included visual acuity, manifest refraction, corneal astigmatism, SIA, flattening effect, and corneal HOAs. Correlation between postoperative corneal HOA and SIA at each follow-up were analysed.
RESULTS
This study assessed data from 106 eyes, of which 64 in Group A and 42 in Group B. The two groups had similar postoperative visual acuity of distance, intermediate and near (all P > 0.05). SIA and corneal HOAs were significantly lower in Group A than Group B in the early postoperative period, while there was no significant difference in the late postoperative period. At 6 months after surgery, the arithmetic mean of SIA over corneal 4mm zone was 0.33 ± 0.19D for temporal incision, and 0.37 ± 0.25D for superior incision. For Group A, the correlations of HOAs and SIA persisted from 1 week to 6 months after surgery. For Group B, the changes in corneal HOAs were significantly related to the SIA at 1 week and 1 month postoperatively.
CONCLUSION
This study suggested the consistency of increasing and recovering process of corneal HOAs and SIA after surgery. Compared to the superior incisions, temporal incisions might induce quicker corneal recovery and less change in SIA and corneal HOAs.
PubMed: 38659425
DOI: 10.2147/OPTH.S456110 -
BMC Ophthalmology Apr 2024To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification... (Observational Study)
Observational Study Comparative Study
PURPOSE
To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS).
SETTING
Department of Ophthalmology, Shanghai Aier Eye Hospital, China.
DESIGN
A retrospective, observational study.
METHODS
Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months.
RESULTS
101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group.
CONCLUSIONS
Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.
Topics: Humans; Retrospective Studies; Male; Female; Phacoemulsification; Visual Acuity; Middle Aged; Laser Therapy; Aged; Multifocal Intraocular Lenses; Refraction, Ocular; Lens Implantation, Intraocular; Pseudophakia; Treatment Outcome; Prosthesis Design; Cataract Extraction; Follow-Up Studies
PubMed: 38658894
DOI: 10.1186/s12886-024-03440-7 -
Arquivos Brasileiros de Oftalmologia 2024To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. (Comparative Study)
Comparative Study
PURPOSE
To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages.
METHODS
Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed.
RESULTS
The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision.
CONCLUSIONS
In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.
Topics: Humans; Keratoconus; Visual Acuity; Male; Female; Retrospective Studies; Keratoplasty, Penetrating; Adult; Cicatrix; Treatment Outcome; Corneal Edema; Young Adult; Corneal Transplantation; Time Factors; Adolescent; Astigmatism; Middle Aged; Postoperative Complications; Cell Count; Endothelium, Corneal
PubMed: 38656029
DOI: 10.5935/0004-2749.2023-0144 -
Taiwan Journal of Ophthalmology 2024The purpose of this study is to investigate visual and tomographic outcomes and complications of long-arc length intrastromal corneal ring segment (ICRS) implantation...
PURPOSE
The purpose of this study is to investigate visual and tomographic outcomes and complications of long-arc length intrastromal corneal ring segment (ICRS) implantation for the treatment of advanced keratoconus.
MATERIALS AND METHODS
This retrospective study enrolled 10 eyes of 9 subjects. All patients received 320-degree ICRS (320-ICRS) implantation with femtosecond laser-assisted technique based on their advanced grading with preoperative high keratometry (K) value, asphericity (Q), and astigmatism. Medical records and corneal tomography changes of consecutive patients were reviewed at baseline, 1, and 3 months after treatment.
RESULTS
There are 6 female and 3 male patients with a mean age of 29.6 ± 7.8 years in this study. Mean K (Km) reduced from 59.01 ± 5.81 D preoperatively to 50.7 ± 5.3 and 50.2 ± 3.66 postoperatively (after 1 month and 3 months respectively, < 0.001). The changes in mean K, K1, K2, and maximum K (Kmax) reading were all statistically significant (all < 0.001). Mean uncorrected distance visual acuity (UCVA) improved from 20/400 to 20/200. Mean best-corrected distance visual acuity (BCVA) improved from 20/100 to 20/60. Both UCVA and BCVA showed a trend of improvement at postoperative month 3, though insignificant in BCVA ( = 0.114). Mean Q improved from -1.59 ± 0.62 preoperatively to -0.48 ± 1.08 and -0.11 ± 1.04 postoperatively (after 1 month and 3 months respectively, = 0.016, 0.002). No intraoperative or postoperative complications were observed.
CONCLUSIONS
The present results suggest that implanting a 320-ICRS is a safe and effective procedure for treating patients with advanced keratoconus. Preoperative corneal measurements and the selection of types and thickness of ICRS are important to prevent unpredictable results.
PubMed: 38654996
DOI: 10.4103/tjo.TJO-D-24-00004 -
Taiwan Journal of Ophthalmology 2024This review explores contemporary challenges in penetrating keratoplasty (PK), focusing on technical intricacies, technological advancements, and strategies for... (Review)
Review
This review explores contemporary challenges in penetrating keratoplasty (PK), focusing on technical intricacies, technological advancements, and strategies for preventing graft rejection. A systematic literature search from January 2018 to July 2023 was conducted across PubMed, Cochrane, Web of Science, Scopus, and EMBASE. The inclusion criteria comprised studies on PK and its comparison with other corneal pathologies, with emphasis on keratoconus (KC). Two independent reviewers screened studies, extracting relevant data. The review covers PK evolution, highlighting infra-red femtosecond lasers' impact on graft shapes, minimizing astigmatism, and enhancing wound healing. Graft rejection, a primary complication, is examined, detailing risk factors and preventive measures. Preoperative considerations, diagnostic techniques for rejection, and PK in KC are discussed. Postoperative care's significance, including intraocular pressure monitoring and steroid administration, is emphasized. The paper concludes with a comprehensive approach to prevent graft rejection, involving topical and systemic medications. An outlook on evolving monoclonal antibody research is presented. As the field progresses, personalized approaches and ongoing therapeutic exploration are expected to refine strategies, enhancing PK outcomes.
PubMed: 38654981
DOI: 10.4103/tjo.TJO-D-24-00001 -
Vision (Basel, Switzerland) Apr 2024Myopia management contact lenses have been shown to successfully decrease the rate of eye elongation in children by changing the peripheral refractive profile of the...
BACKGROUND
Myopia management contact lenses have been shown to successfully decrease the rate of eye elongation in children by changing the peripheral refractive profile of the retina. Despite the efforts of the scientific community, the retinal response mechanism to defocus is still unknown. The purpose of this study was to evaluate the local electrophysiological response of the retina with a myopia control contact lens (CL) compared to a single-vision CL of the same material.
METHODS
The retinal electrical activity and peripheral refraction of 16 eyes (16 subjects, 27.5 ± 5.7 years, 13 females and 3 males) with myopia between -0.75 D and -6.00 D (astigmatism < 1.00 D) were assessed with two CLs (Filcon 5B): a single-vision (SV) CL and an extended-depth-of-focus (EDOF) CL used for myopia management. The peripheral refraction was assessed with an open-field WAM-5500 auto-refractometer/keratometer in four meridians separated by 45° at 2.50 m distance. The global-flash multifocal electroretinogram (gf-mfERG) was recorded with the Reti-port/scan21 (Roland Consult) using a stimulus of 61 hexagons. The implicit time (in milliseconds) and response density (RD, in nV/deg) of the direct (DC) and induced (IC) components were used for comparison between lenses in physiological pupil conditions.
RESULTS
Although the EDOF decreased both the HCVA and the LCVA (one and two lines, respectively; < 0.003), it still allowed a good VA. The EDOF lens induced a myopic shift in most retinal areas, with a higher and statistically significant effect on the nasal retina. No differences in the implicit times of the DC and IC components were observed between SV and EDOF. Compared with the SV, the EDOF lens showed a higher RD in the IC component in the foveal region ( = 0.032). In the remaining retinal areas, the EDOF evoked lower, non-statistically significant RD in both the DC and IC components.
CONCLUSIONS
The EDOF myopia control CL enhanced the response of the inner layers of the fovea. This might suggest that, besides other mechanisms potentially involved, the central foveal retinal activity might be involved in the mechanism of myopia control with these lenses.
PubMed: 38651440
DOI: 10.3390/vision8020019 -
Frontiers in Medicine 2024Myopia is causing a major public health concern, with its prevalence increasing globally. This study aimed to discuss posterior chamber phakic intraocular lens (pIOL)... (Review)
Review
INTRODUCTION
Myopia is causing a major public health concern, with its prevalence increasing globally. This study aimed to discuss posterior chamber phakic intraocular lens (pIOL) research publication trends and hotspots over the past 20 years.
METHODS
Bibliometric analysis was performed using the Web Science Core Collection to investigate posterior-chamber pIOL research publication trends. The extracted records were analyzed, and a knowledge map was built using VOSviewer v.1.6.20. The analysis included visualizing the annual publication count, countries/regions distribution, international and institutional collaborations, author productivity, and journal contribution, in addition to identifying knowledge bases and hotspots. Burst keywords were extracted using CiteSpace v.6.1.R.
RESULTS
In total, 791 articles on posterior chamber pIOLs published between 2003 and 2023 were retrieved. China had the highest number of publications, whereas Japanese papers received the most citations. Fudan University had the highest number of publications, with articles from Kitasato University having the highest number of citations. Regarding individual research, Xingtao Zhou has published the most significant number of articles, and Shimizu Kimiya had the highest number of citations. The top productive/influential journal was 'Journal of Cataract & Refractive Surgery'. The top cited references primarily focused on reporting the clinical outcomes of implantable collamer lens (ICL) for individuals with moderate to high myopia. The keywords primarily formed four clusters: posterior chamber pIOL clinical outcomes for myopic astigmatism correction, posterior chamber pIOL implantation complications, ICL size selection and postoperative vault predictions, and postoperative visual quality following posterior chamber pIOL implantation.
CONCLUSION
This study presents the first bibliometric analysis of research trends in posterior chamber pIOL over the past two decades. We investigated the current state and emerging trends of global collaboration and research focal points in this field, offering fresh insights and guidance for researchers.
PubMed: 38651068
DOI: 10.3389/fmed.2024.1391327 -
Indian Journal of Ophthalmology May 2024To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and... (Comparative Study)
Comparative Study
Comparative evaluation of biomechanical changes and aberration profile following accelerated collagen cross-linking using hypo-osmolar and iso-osmolar riboflavin: A prospective study.
PURPOSE
To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively.
METHODS
This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups.
RESULTS
In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1.
CONCLUSION
Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.
Topics: Adolescent; Adult; Female; Humans; Male; Young Adult; Biomechanical Phenomena; Collagen; Cornea; Corneal Stroma; Corneal Topography; Corneal Wavefront Aberration; Cross-Linking Reagents; Follow-Up Studies; Keratoconus; Photochemotherapy; Photosensitizing Agents; Prospective Studies; Refraction, Ocular; Riboflavin; Ultraviolet Rays; Visual Acuity; Child
PubMed: 38648433
DOI: 10.4103/IJO.IJO_1387_23 -
BMC Ophthalmology Apr 2024Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained...
BACKGROUND
Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction.
METHODS
We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences.
RESULTS
Binocular examination of 111 children aged 4.86±1.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (p < 0.001) and strong correlation was found between all refractive measurements (Pearson's r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was < 10° in 144 eyes (64.9%).
CONCLUSIONS
Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.
Topics: Child; Humans; Mydriatics; Vision Screening; Refractive Errors; Refraction, Ocular; Astigmatism
PubMed: 38641836
DOI: 10.1186/s12886-024-03459-w -
PloS One 2024The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface)...
PURPOSE
The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK.
METHODS
From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components.
RESULTS
The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK-K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum).
CONCLUSION
In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism.
Topics: Humans; Astigmatism; Biometry; Cornea; Cataract Extraction; Corneal Diseases
PubMed: 38640111
DOI: 10.1371/journal.pone.0300576