Cureus Mar 2024Introduction The disinfection of impressions is crucial to eliminate the viral and other microbial loads to prevent the cross contamination of diseases. The aim of this...
Introduction The disinfection of impressions is crucial to eliminate the viral and other microbial loads to prevent the cross contamination of diseases. The aim of this study was to compare the effect of different virucidal disinfecting methods on the dimensional accuracy and surface detail reproduction (SDR) of impression materials. Methods A total of 160 samples were fabricated with different impression materials using zinc oxide eugenol (Group 1), alginate (Group 2), polyether (Group 3), and addition silicone (Group 4) impression materials, each containing 40 samples (n=40). These groups were further divided into Subgroups A, B, C, and D (n=10) based on the disinfecting method used. Disinfection was carried out using 0.2% peracetic acid (A), a natural polymer of glucosamine (B), ultraviolet (UV) radiation (C), and ozonated water (D). The disinfected impressions were poured in type IV gypsum, and the obtained casts were checked for dimensional accuracy and surface detail reproduction (SDR). For dimensional accuracy, a one-way analysis of variance (ANOVA) test and, for surface detail reproduction, the chi-square test were used to compare the different subgroups of each impression material separately. Results Zinc oxide eugenol samples showed the lowest mean dimensional change when disinfected with 0.2% peracetic acid (1A=154.1 µm), and alginate showed the lowest mean dimensional change when disinfected using ozonated water (2D=134.9 µm). On the other hand, the lowest mean dimensional change observed in polyether and addition silicone samples was those which were disinfected using UV radiation (3C=100.9 µm and 4C=113.5 µm). Surface detail was reproduced adequately in most of the samples. Conclusion A 0.2% peracetic acid could be used to disinfect zinc oxide eugenol impressions, ozonated water for alginate impressions, and UV radiation for polyether and addition silicone impressions.
PubMed: 38623104
DOI: 10.7759/cureus.55931 -
BMC Oral Health Apr 2024Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a...
BACKGROUND
Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods.
METHODS
This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes.
RESULTS
A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes.
CONCLUSIONS
This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.
Topics: Humans; Disinfection; Glutaral; Sodium Hypochlorite; Disinfectants; Dental Impression Materials; Dental Impression Technique
PubMed: 38622548
DOI: 10.1186/s12903-024-04188-8 -
Materials (Basel, Switzerland) Mar 2024This study presents a methodology to prevent the overdesign of electric dispensers for dental impression materials by analyzing the necessary load and determining the...
This study presents a methodology to prevent the overdesign of electric dispensers for dental impression materials by analyzing the necessary load and determining the appropriate pressurization speed and drive motor capacity. We derived an equation to calculate the required torque and rotational speed of the motor based on the extrusion load and the speed of the impression material. A specialized load measurement system was developed to measure the load necessary to extrude the impression material. Through experiments and image processing, we measured the radius of curvature of the trajectory of the impression material and correlated it with the pressurization speed. Techniques such as position coordinate plotting, curve fitting, and circle fitting were employed to determine the pressurization speed that aligns with the manufacturer's recommended curvature radius. These findings led to a substantial decrease in the necessary motor torque and rotational speed compared with the current standards. This research provides a systematic approach to sizing drive motors using extrusion load and pressurization speed, aiming to reduce overdesign, power consumption, and the weight and size of the motor and battery, thereby contributing to the development of more efficient and compact dental impression material dispensers.
PubMed: 38611981
DOI: 10.3390/ma17071467 -
Polymers Apr 2024The impression materials utilized today in dental medicine offer a good reproducibility and are easily accepted by patients. However, because they are polymer-based,...
The impression materials utilized today in dental medicine offer a good reproducibility and are easily accepted by patients. However, because they are polymer-based, they have issues regarding their dimensional stability. In this respect, the present work proposes a new type of dental impression, which is reinforced with rigid mouthguards. The aim of the study is to test the performances of such new impressions by comparing them to conventional ones-from this critical point of view, of the dimensional stability. Three types of polymeric materials were considered for both types of impressions: alginate, condensation silicone, and addition silicone. In order to obtain the new type of impressions, a manufacturing technique was developed, comprising the following phases: (i) conventional impressions were made; (ii) a plaster model was duplicated, and 15 rigid mouthguards were obtained; (iii) they were inserted in the impression technique, with each mouthguard positioned on the cast before the high-consistency material was inserted in the tray and the practitioner took the impression; (iv) the mouthguard remained in the tray and the low-viscosity material was inserted over the mouthguard; (v) the impression was positioned on the model, and after the material hardened, the mouthguard-reinforced impression was analyzed. In the evaluation of the dimensional stability, rigorous statistical analysis was essential to discern the performance differences between conventional and mouthguard-reinforced dental impressions. Statistical analyses employed non-parametric Mann-Whitney U tests because of the non-normal distribution of the data. They indicated a statistically significant improvement in the dimensional stability of addition silicone impressions when reinforced with mouthguards ( < 0.05), showcasing superior performance over conventional methods. Conversely, alginate and condensation silicone reinforced impressions did not exhibit the same level of stability improvement, suggesting the need for further optimization of these materials. In conclusion, from the three considered elastomers, addition silicone was found to be the prime candidate for high-precision dental impressions, with the potential to improve their quality from conventional impressions by utilizing the proposed reinforcing technique.
PubMed: 38611252
DOI: 10.3390/polym16070994 -
Journal of Pharmacy & Bioallied Sciences Feb 2024The transfer of interocclusal data from the patient's mouth to articulators utilizing various types of recording media is necessary for the production of dental...
UNLABELLED
The transfer of interocclusal data from the patient's mouth to articulators utilizing various types of recording media is necessary for the production of dental prostheses. Occlusal errors in the final prosthesis result from any discrepancies in these interocclusal records.
MATERIALS AND METHODS
The purpose of this study was to assess the linear dimensional changes in the four elastomeric interocclusal recording materials as well as the material's resistance to compression during the cast mounting on the articulator.
RESULT
All four elastomeric materials showed decreasing stability over time and 2 mm thickness showed the highest compression resistance with minimal articulation error.
CONCLUSION
Dimensional stability depends on material and time factors, and compressive resistance decreases with increasing thickness.
PubMed: 38595621
DOI: 10.4103/jpbs.jpbs_1047_23 -
Journal of Pharmacy & Bioallied Sciences Feb 2024To understand the psychodynamics of tobacco use among 11- to 14-year-olds in Ahmedabad, India.
AIM
To understand the psychodynamics of tobacco use among 11- to 14-year-olds in Ahmedabad, India.
MATERIALS AND METHODS
A self-administered questionnaire was used to gather information on tobacco use from 5,266 students, aged 11 to 14, enrolled in government-aided English medium schools in Ahmedabad. IBM® SPSS® 26.0 software along with Chi-square tests were used to analyze the data.
RESULTS
A total of 7.2% (376) had ever used tobacco. Of the users, 96.6% (363) knew it was harmful, 76.3% (287) were boys, and 85.2% (320) were initiated by family and friends.
CONCLUSION
Despite being aware of the dangers of tobacco and being unable to purchase from vendors, children continued to obtain tobacco products, being influenced by their close social networks. An effective cessation measure should be directed toward this psychodynamic etiology.
PubMed: 38595591
DOI: 10.4103/jpbs.jpbs_920_23 -
Journal of Pharmacy & Bioallied Sciences Feb 2024The study's objective was to assess the dimensional accuracy of hybrid polyether and polyvinyl siloxane materials for implant impressions.
AIM
The study's objective was to assess the dimensional accuracy of hybrid polyether and polyvinyl siloxane materials for implant impressions.
MATERIALS AND METHODS
Nine groups were created from 45 samples of various building materials and construction techniques from the study. Five samples were tested, and 45 impressions were recorded.
RESULTS
The hybrid non-splinted technique has improved implant site replication, accuracy, and low interimplant distance alterations.
CONCLUSION
The finest possible reproduction of implant sites on the master cast was made feasible by the use of an open, non-splinted method and a hybrid polyvinyl siloxane-polyether impression material.
PubMed: 38595438
DOI: 10.4103/jpbs.jpbs_886_23 -
Journal of Pharmacy & Bioallied Sciences Feb 2024Smart materials encompass a variety of substances, including smart antimicrobial peptides, pit and fissure sealants, impression materials, cement, and sutures. These... (Review)
Review
Smart materials encompass a variety of substances, including smart antimicrobial peptides, pit and fissure sealants, impression materials, cement, and sutures. These materials can change properties under specific stimuli such as temperature, stress, moisture, pH, or electric and magnetic fields. These constituents signify the commencement of a novel era or epoch in the field of smart dentistry and exhibit the potential for enhanced efficacy in the future.
PubMed: 38595377
DOI: 10.4103/jpbs.jpbs_550_23 -
Journal of Pharmacy & Bioallied Sciences Feb 2024The objectives of the current study was to evaluate the disinfection efficacy of ozone, ultraviolet (UV) radiation, herbal and glutaraldehyde method for sterilization of...
OBJECTIVES
The objectives of the current study was to evaluate the disinfection efficacy of ozone, ultraviolet (UV) radiation, herbal and glutaraldehyde method for sterilization of elastomeric impression materials.
MATERIALS AND METHODS
Disinfection of elastomeric impression material was performed with each of the disinfection methods: ozone, UV radiation, herbal, and glutaraldehyde. Later microbiological analysis was performed and the colony-forming units were evaluated and compared.
RESULTS
The highest disinfection efficacy was found with glutaraldehyde, followed by ozone and UV radiation, and the least with neem herbal rinse. Intergroup comparison was highly significant.
CONCLUSION
Dry gaseous ozone and UV radiation can be used effectively for the disinfection of impressions.
PubMed: 38595356
DOI: 10.4103/jpbs.jpbs_962_23 -
BMC Oral Health Apr 2024The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the...
BACKGROUND
The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the autotransplantation of single-rooted teeth.
MATERIALS AND METHODS
Forty samples were assigned to the following surgical techniques for drilling guidance of the artificial sockets: A. augmented reality technique (AR) (n = 20) and B. conventional free-hand technique (FT) (n = 20). Then, two models with 10 teeth each were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan. Afterwards, the autotrasplanted teeth were planned in a 3D dental implant planning software and transferred to the augmented reality device. Then, a postoperative CBCT scan was performed. Data sets from postoperative CBCT scans were aligned to the planning in the 3D implant planning software to analize the coronal, apical and angular deviations. Student's t-test and Mann-Whitney non-parametric statistical analysis were used to analyze the results.
RESULTS
No statistically significant differences were shown at coronal (p = 0.123) and angular (p = 0.340) level; however, apical deviations between AR and FT study groups (p = 0.008) were statistically significant different.
CONCLUSION
The augmented reality appliance provides higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.
Topics: Humans; Augmented Reality; Transplantation, Autologous; Reproducibility of Results; Computer-Aided Design; Surgery, Computer-Assisted; Cone-Beam Computed Tomography; Dental Implants; Imaging, Three-Dimensional
PubMed: 38575886
DOI: 10.1186/s12903-024-04173-1