-
Indian Journal of Dermatology 2024
PubMed: 38841239
DOI: 10.4103/ijd.ijd_1101_23 -
The Journal of the Canadian... Apr 2024Axillary-subclavian venous thrombosis (ASVT) is a type of upper extremity deep vein thrombosis (UEDVT). UEDVTs are classified as either primary or secondary depending on...
BACKGROUND
Axillary-subclavian venous thrombosis (ASVT) is a type of upper extremity deep vein thrombosis (UEDVT). UEDVTs are classified as either primary or secondary depending on their etiology. Although uncommon, clinicians should be aware of the clinical presentation of UEDVT as timely diagnosis and early treatment is critical in preventing possible post-thrombotic complications.
CASE PRESENTATION
We report a rare case of axillary-subclavian and internal jugular vein thrombosis in the absence of clear risk factors in a 78-year-old male weightlifter who presented to the office with two-week duration of left upper extremity pain and swelling following strenuous exercise at the gym.
SUMMARY
The combination of unusual thrombi location, in addition to the unusual absence of existing thoracic-outlet compression or indwelling medical hardware, makes our case of UEDVT especially uncommon. Clinicians should be aware of this rare disease due to the debilitating effects both in the short and long term.
PubMed: 38840961
DOI: No ID Found -
SAGE Open Medicine 2024We explored the differences in deep venous catheterization-associated complications between patients with hematological malignancies after peripherally inserted central...
A retrospective cohort study of implantable venous access port-related and peripherally inserted central catheter-related complications in patients with hematological malignancies in China.
OBJECTIVE
We explored the differences in deep venous catheterization-associated complications between patients with hematological malignancies after peripherally inserted central catheter placement and such patients after implantable venous access port catheterization.
INTRODUCTION
peripherally inserted central catheters and implantable venous access ports are the most popular devices used for chemotherapy. However, no study has revealed differences between peripherally inserted central catheters and implantable venous access ports in Chinese patients with hematological malignancies.
METHODS
The clinical data of 322 patients with hematological malignancies who were treated from January 1, 2020 to December 30, 2021 were included in a retrospective cohort study. Postoperative color Doppler ultrasonography and follow-up results were used to compare the incidence rates of deep venous catheterization -associated complications after peripherally inserted central catheters and implantable venous access ports catheterization.
RESULTS
The relative risk of catheter-related complications considering the type of device was 8.3 (95% CI = 3.0-22.8). In addition, chi-square segmentation analysis revealed a significant difference in the complication rate between the internal jugular vein and the basilic vein (χ = 22.002, < 0.0001) and between the subclavian vein and the basilic vein (χ = 28.940, < 0.0001).
CONCLUSION
Implantable venous access ports are safer than peripherally inserted central catheters for Chinese patients with hematological malignancies. The implantation of implantable venous access ports could be firstly considered for systematic anti-cancer treatment.
PubMed: 38826826
DOI: 10.1177/20503121241257190 -
Cureus Apr 2024The prolonged use of hemodialysis catheters is associated with several complications with infection being the most common. The increased susceptibility to infections in...
The prolonged use of hemodialysis catheters is associated with several complications with infection being the most common. The increased susceptibility to infections in patients on hemodialysis can be attributed to decreased immunity, though age, other comorbidities, and properties of the catheter act as modifiers. Hematogenous spread of the infection can lead to sepsis and seeding into other organs. In this article, we report an unusual case of septic emboli to the brain in a 30-year-old male on prolonged use of a right internal jugular vein (IJV) catheter for hemodialysis. An interesting finding in the case was the presence of a patent foramen ovale (PFO), a persisting embryonic structure that allows right-to-left shunting. It is suspected that this PFO led to the passage of septic emboli from the right IJV site to the brain. Before our case, septic emboli to the brain have been reported to occur from valvular vegetation in case of infective endocarditis. The mainstay of managing patients with septic emboli is the use of antibiotics; additional interventions may be needed on a case-to-case basis.
PubMed: 38826600
DOI: 10.7759/cureus.59419 -
Molecules and Cells Jun 2024Excessive blood vessel wall thickening, known as intimal hyperplasia, can result from injury or inflammation and increase the risk of vascular diseases. Tumor necrosis...
Suppression of neointimal hyperplasia induced by arteriovenous anastomosis and balloon injury in rats by multimeric tumor necrosis factor-related apoptosis-inducing ligand.
Excessive blood vessel wall thickening, known as intimal hyperplasia, can result from injury or inflammation and increase the risk of vascular diseases. Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) plays key roles in tumor surveillance, autoimmune diseases, and apoptosis; however, its role in vascular stenosis remains controversial. Treatment with recombinant isoleucine zipper hexamerization domain soluble TRAIL (ILz(6):TRAIL) significantly inhibited the progression of neointimal hyperplasia (NH) induced by anastomosis of the carotid artery and jugular vein dose dependently, and adenovirus expressing secretable ILz(6):TRAIL also inhibited NH induced by balloon injury in the femoral artery of rats. This study demonstrated the preventive and partial regressive effects of ILz(6):TRAIL on anastomosis of the carotid artery and jugular vein- or balloon-induced NH.
Topics: Animals; Hyperplasia; Neointima; Rats; Male; TNF-Related Apoptosis-Inducing Ligand; Rats, Sprague-Dawley; Carotid Arteries; Jugular Veins; Femoral Artery
PubMed: 38823606
DOI: 10.1016/j.mocell.2024.100075 -
Journal of Medical Case Reports May 2024Lemierre's syndrome is a fatal and rare disease that is typically characterized by oropharyngeal infection and internal jugular vein thrombosis. Timely institution of... (Review)
Review
BACKGROUND
Lemierre's syndrome is a fatal and rare disease that is typically characterized by oropharyngeal infection and internal jugular vein thrombosis. Timely institution of appropriate antibiotics is the standard treatment.
CASE PRESENTATION
The authors report a case of Lemierre's syndrome. A 67-year-old male patient of Han ethnicity in China suffered from a large inflammatory neck mass involving left internal jugular vein thrombosis diagnosed as Lemierre's syndrome and finally cured by surgical treatment. In addition, a literature review was carried out through PubMed using the terms "Lemierre's syndrome/disease and review, meta-analysis or retrospective study" and "Lemierre's syndrome/disease and internal jugular vein". This search yielded six articles that recorded surgical methods such as drainage, craniotomy, tooth extraction, and ligation of the occluded vein to give clinicians more ideas about the treatment of the Lemierre's syndrome.
CONCLUSION
This is the first review to summarize the conditions under which surgical treatment are conducted. Additionally, this is the first report of such a large inflammatory neck mass that was completely cured by surgical resection and internal jugular vein ligation. The authors also offer several conclusions regarding surgical intervention in Lemierre's syndrome for the first time.
Topics: Humans; Lemierre Syndrome; Male; Jugular Veins; Aged; Treatment Outcome; Ligation; Anti-Bacterial Agents; Drainage; Tomography, X-Ray Computed; Venous Thrombosis
PubMed: 38816729
DOI: 10.1186/s13256-024-04584-2 -
Cardiorenal Medicine May 2024Congestion, marked by elevated cardiac filling pressures and their repercussions, is a contributing factor to morbidity and mortality in heart failure and critical... (Review)
Review
Congestion, marked by elevated cardiac filling pressures and their repercussions, is a contributing factor to morbidity and mortality in heart failure and critical illness. Relying on traditional methods for bedside evaluation often leads to inadequate decongestion and increased hospital readmissions. Point-of-care ultrasound (POCUS), particularly multi-organ POCUS, including the Venous Excess Ultrasound (VExUS), offers a promising approach in this scenario. VExUS enables the quantification of systemic venous congestion, aiding in fluid overload states by assessing inferior vena cava and venous Doppler waveforms. This comprehensive review delves into the latest developments in comprehending and evaluating congestion, shedding light on technical intricacies to enhance the effective application of VExUS. Recent studies emphasize the importance of evaluating signs of hemodynamic congestion before administering intravenous fluids, highlighting the concept of 'fluid tolerance'. Moreover, VExUS-guided decongestion significantly improves decongestion rates in acute decompensated heart failure patients with acute kidney injury. Newer studies also highlight the prognostic implications of VExUS in the general ICU cohorts not confining to cardiac surgery patients. However, performing VExUS without understanding technical pitfalls may lead to clinical errors. Technical considerations in performing VExUS include nuances related to inferior vena cava and internal jugular vein ultrasound and familiarity with Doppler principles, optimal settings, and artifacts. Additionally, local structural alterations such as those seen in liver and kidney disease impact Doppler waveforms, emphasizing the need for careful interpretation. Overall, VExUS presents a valuable tool for assessing congestion and guiding management, provided clinicians are familiar with its technical complexities and interpret findings judiciously.
PubMed: 38815571
DOI: 10.1159/000539469 -
Journal of Neurophysiology May 2024Active sampling in the olfactory domain is an important aspect of mouse behaviour, and there is increasing evidence that respiration-entrained neural activity outside of...
Active sampling in the olfactory domain is an important aspect of mouse behaviour, and there is increasing evidence that respiration-entrained neural activity outside of the olfactory system sets an important global brain rhythm. It is therefore important to accurately measure breathing during natural behaviours. We develop a new approach to do this in freely moving animals, by implanting a telemetry-based pressure sensor into the right jugular vein, which allows for wireless monitoring of thoracic pressure. After verifying this technique against standard head-fixed respiration measurements, we combined it with EEG and EMG recording and used evolving partial coherence analysis to investigate the relationship between respiration and brain activity across a range of experiments in which the mice could move freely. During voluntary exploration of odours and objects, we found that the association between respiration and cortical delta and theta rhythms decreased, while the association between respiration and cortical alpha rhythm increased. During sleep, however, the presentation of an odour was able to cause a transient increase in sniffing without changing dominant sleep rhythms (delta and theta) in the cortex. Our data align with the emerging idea that the respiration rhythm could act as a synchronising scaffold for specific brain rhythms during wakefulness and exploration, but suggest that respiratory changes are less able to impact brain activity during sleep. Combining wireless respiration monitoring with different types of brain recording across a variety of behaviours will further increase our understanding of the important links between active sampling, passive respiration, and neural activity.
PubMed: 38810259
DOI: 10.1152/jn.00330.2023 -
Pain Physician May 2024Glossopharyngeal neuralgia (GPN) is a condition that causes simultaneous headache and facial pain. The treatment for GPN is similar to the treatment for trigeminal... (Comparative Study)
Comparative Study
Computed Tomography-Guided Radiofrequency Ablation for Glossopharyngeal Neuralgia: Comparison of Cervical Computed Tomography Angiography, Transverse Process of Atlas, and Styloid Process Localization to Styloid Process Localization Alone.
BACKGROUND
Glossopharyngeal neuralgia (GPN) is a condition that causes simultaneous headache and facial pain. The treatment for GPN is similar to the treatment for trigeminal neuralgia. Craniotomy microvascular decompression (MVD) or radiofrequency (RF) therapy is needed if conservative treatment with oral drugs fails. Therefore, the choice of radiofrequency therapy target is essential when treating GPN. However, finding the glossopharyngeal nerve simply by styloid process positioning is challenging.
STUDY DESIGN
Prospective, clinical research study.
SETTING
Department of Anesthesiology and Pain Medical Center, Jiaxing, China.
OBJECTIVE
To compare the clinical effects of computed tomography (CT)-guided RF treatments on GPN when the triple localization of cervical CT, the transverse process of the atlas, and the styloid process is used to those achieved when the treatments are guided by the styloid process alone.
METHODS
From August 2016 to December 2019, 19 cases of GPN neuralgia were treated by radiofrequency under the guidance of CT guided by the styloid process only. (These patients comprised the single localization (SL) of styloid process group, in whom the target of the RF treatments was the posterior medial side of half of the styloid process). From January 2020 to December 2022, 16 cases of GPN were treated by RF under the guidance of CT with cervical CTA (CT angiography), the transverse process of the atlas, and the styloid process. (These patients were placed in the TL group, in whom the target of RF therapy was the gap between the internal carotid artery and the internal jugular vein behind the horizontal styloid process at the lower edge of the transverse process of the atlas). Two percent lidocaine was injected subcutaneously at the needle insertion site, and a stylet with a 21-gauge blunt RF needle (model: 240100, manufacturer: Englander Medical Technology Co., Ltd.) was slowly advanced toward the target. After that, an RF probe was introduced, then low (2 Hz)- and high (50 Hz)-frequency currents of the RF instrument (model: PMG-230, Canada Baylis company) were applied to stimulate. A successful test was defined as a 0.5-1.0 mA current stimulation that could induce the original pain area in the pharynx, the inner ear, or both, without any abnormal irritation of the vagus or accessory nerves. If the first test was unsuccessful, then in the SL group, the needle tip's position was adjusted to the distal end of the styloid process, and in the triple localization (TL) group, the needle tip depth's was fine-tuned. A continuous RF treatment was given after a successful test. The RF temperature was 95ºC for 180 seconds. The time that the first puncture reached the target, the puncture paths, the success rate of the first test, the time that the glossopharyngeal nerve was found, the frequency of adjustments to the position of the RF needle, the incidence of intraoperative and postoperative complications, and the therapeutic effects were recorded.
RESULTS
There were no significant differences in demographic data such as age, medical history, lateral classification, and pain score between the groups, but the TL group had a higher proportion of women than did the SL group. All patients' puncture targets were identified according to the designed puncture path before the operation. There was no difference between the 2 groups in the time of the first puncture to the target (5.05 ± 1.22 vs. 5.82 ± 1.51, P = 0.18), and the designed puncture depth (3.65 ± 0.39 vs. 4.04 ± 0.44). The difference in puncture angles (13.48 ± 3.56 vs. 17.84 ± 3.98, P < 0.01) was statistically significant, and in 8 cases in the SL group, the glossopharyngeal nerve could not be found after 60 minutes of testing, so the RF treatment was terminated. Meanwhile, this problem occurred in only 2 cases in the TL group. There were 3 cervical hematoma cases and 2 cases of transient hoarseness and cough in the SL group, whereas the TL group had, respectively, 0 and one cases of those issues. There was no death in either group.
LIMITATIONS
More clinical data should be collected in future studies.
CONCLUSION
When using RF as a treatment for GPN, the glossopharyngeal nerve is easier to find by using the triple positioning of the cervical CTA, the transverse process of the atlas and the styloid process as the target to determine the anterior medial edge of the internal carotid artery behind the styloid process at the level of the lower edge of the atlas transverse process. The glossopharyngeal nerve is more difficult to locate when only the posterior medial edge of the styloid process is targeted. The single-time effective rate of 180 seconds of RF ablation at 90ºC for GPN can reach 87.5% (14/16), suggesting the treatment's potential for clinical application.
Topics: Humans; Glossopharyngeal Nerve Diseases; Radiofrequency Ablation; Prospective Studies; Computed Tomography Angiography; Female; Middle Aged; Male; Cervical Atlas; Aged; Temporal Bone
PubMed: 38805535
DOI: No ID Found -
Journal of Surgical Case Reports May 2024Percutaneous central vein catheterization is commonly performed to access venous circulation for various clinical indications. However, unintentional arterial puncture...
Percutaneous central vein catheterization is commonly performed to access venous circulation for various clinical indications. However, unintentional arterial puncture may occur which can result in catastrophic complications. We report a case of an inadvertent right brachiocephalic artery cannulation in a 77-year-old lady planned for haemodialysis via a percutaneous internal jugular vein vascular access performed under ultrasound guidance. As an intravascular stent is not favourable in view of the close proximity of the right common carotid artery to the site of puncture as well as the risk of massive bleeding upon simple removal of the catheter, an open surgical removal via a median sternotomy was performed. Acquiring the competency in procedural skills, an understanding of the surgical anatomy and anticipating impending complications are of paramount importance in preventing as well as in mitigating the above complication.
PubMed: 38800502
DOI: 10.1093/jscr/rjae329