Hip & Pelvis Jun 2024Total hip arthroplasty (THA) is an effective treatment for osteoarthritis, and the popularity of the direct anterior approach has increased due to more rapid recovery... (Review)
Review
Total hip arthroplasty (THA) is an effective treatment for osteoarthritis, and the popularity of the direct anterior approach has increased due to more rapid recovery and increased stability. Instability, commonly caused by component malposition, remains a significant concern. The dynamic relationship between the pelvis and lumbar spine, deemed spinopelvic motion, is considered an important factor in stability. Various parameters are used in evaluating spinopelvic motion. Understanding spinopelvic motion is critical, and executing a precise plan for positioning the implant can be difficult with manual instrumentation. Robotic and/or navigation systems have been developed in the effort to enhance THA outcomes and for implementing spinopelvic parameters. These systems can be classified into three categories: X-ray/fluoroscopy-based, imageless, and computed tomography (CT)-based. Each system has advantages and limitations. When using CT-based systems, preoperative CT scans are used to assist with preoperative planning and intraoperative execution, providing feedback on implant position and restoration of hip biomechanics within a functional safe zone developed according to each patient's specific spinopelvic parameters. Several studies have demonstrated the accuracy and reproducibility of robotic systems with regard to implant positioning and leg length discrepancy. Some studies have reported better radiographic and clinical outcomes with use of robotic-assisted THA. However, clinical outcomes comparable to those for manual THA have also been reported. Robotic systems offer advantages in terms of accuracy, precision, and potentially reduced rates of dislocation. Additional research, including conduct of randomized controlled trials, will be required in order to evaluate the long-term outcomes and cost-effectiveness of robotic-assisted THA.
PubMed: 38825818
DOI: 10.5371/hp.2024.36.2.87 -
Structural Heart : the Journal of the... May 2024Treatment options for patients with mitral regurgitation (MR) and mitral annular calcification (MAC) are limited. The limitations of current transcatheter mitral valve...
BACKGROUND
Treatment options for patients with mitral regurgitation (MR) and mitral annular calcification (MAC) are limited. The limitations of current transcatheter mitral valve replacement (TMVR) technologies include high screen failure rates, increased risk of left ventricular outflow tract obstruction, and high residual regurgitation. The aim of this study was to evaluate outcomes of TMVR with the AltaValve system (4C Medical, Maple Grove, MN), a supra-annular TMVR with atrial fixation, in patients with severe MR and moderate or severe MAC.
METHODS
Six patients with moderate or severe MAC who were treated with AltaValve TMVR had procedural and mid-term outcomes available.
RESULTS
Technical success was achieved in all patients. Median follow-up was 232 days. At discharge, 80% of patients had none/trace MR, and 20% had mild MR. There was no intraprocedural mortality, device malposition, embolization, or thrombosis. One patient expired 3 days postprocedure due to complications related to the transapical access. All other patients were discharged from the hospital without issues. Echocardiography assessments at 30 days showed complete resolution of MR in all patients, with 1 patient with mild MR and a mean mitral valve gradient of 3.7 ± 1.4 mmHg. All patients were in New York Heart Association Class I/II at 30-day follow-up, showing marked improvement as compared with baseline.
CONCLUSIONS
In patients with severe MR and severe MAC, the AltaValve TMVR technology may represent a viable treatment option. The atrial fixation minimizes the risk of left ventricular outflow tract obstruction and potentially expands treatable patients, especially in patients with MAC.
PubMed: 38799804
DOI: 10.1016/j.shj.2024.100294 -
Reumatologia 2024Total hip arthroplasty (THA) is nowadays considered as the most effective treatment option for end-stage hip osteoarthritis (OA) and one of the most successful...
INTRODUCTION
Total hip arthroplasty (THA) is nowadays considered as the most effective treatment option for end-stage hip osteoarthritis (OA) and one of the most successful orthopedic procedures. Precise reproduction of the center of rotation (COR) is among the most important aspects of recreating native hip biomechanics after THA as it is strictly related to muscle tension and force distribution within the hip joint. Both vertical and horizontal shift in cup positioning and COR restoration are commonly observed radiological signs corresponding with lesser functional outcome. The aim of this study was to assess whether the superior border of the native acetabulum morphology has an impact on cup positioning and COR restoration in patients undergoing THA as treatment of primary OA of the hip.
MATERIAL AND METHODS
A cohort of 150 consecutive patients with diagnosis of end-stage primary hip OA who underwent THA via an anterolateral approach with the same implant in 2021 was analyzed retrospectively. Standard standing pelvic X-rays were performed pre- and postoperatively and appropriate measurements were taken. Several radiological parameters on obtained X-rays were assessed. Statistical analysis of all the measurements was performed.
RESULTS
There was a statistically significant positive weak correlation between cup offset and acetabular roof angle ( = 0.25, = 0.002). There were statistically insignificant positive correlations between acetabular roof angle and COR restoration ( = 0.14, = 0.097), acetabular roof angle and total offset ( = 0.087, = 0.29) and a negative correlation between acetabular roof angle and femoral offset ( = 0.071, = 0.39).
CONCLUSIONS
The present study revealed that preoperative acetabular roof angle influences the positioning of the prosthetic cup in the transverse axis. There also seems to be a correlation between the acetabular roof angle and COR restoration, but its significance needs further evaluation. Surgeons could use this knowledge to preoperatively assess the risk of cup malposition and adjust their technique during the THA procedure with probable improvement of hip function.
PubMed: 38799773
DOI: 10.5114/reum/186724 -
HeartRhythm Case Reports May 2024
PubMed: 38799594
DOI: 10.1016/j.hrcr.2024.02.009 -
Journal of Imaging Apr 2024The position of the fetal head during engagement and progression in the birth canal is the primary cause of dystocic labor and arrest of progression, often due to...
The position of the fetal head during engagement and progression in the birth canal is the primary cause of dystocic labor and arrest of progression, often due to malposition and malrotation. The authors performed an investigation on pregnant women in labor, who all underwent vaginal digital examination by obstetricians and midwives as well as intrapartum ultrasonography to collect four "geometric parameters", measured in all the women. All parameters were measured using artificial intelligence and machine learning algorithms, called AIDA (artificial intelligence dystocia algorithm), which incorporates a human-in-the-loop approach, that is, to use AI (artificial intelligence) algorithms that prioritize the physician's decision and explainable artificial intelligence (XAI). The AIDA was structured into five classes. After a number of "geometric parameters" were collected, the data obtained from the AIDA analysis were entered into a red, yellow, or green zone, linked to the analysis of the progress of labor. Using the AIDA analysis, we were able to identify five reference classes for patients in labor, each of which had a certain sort of birth outcome. A 100% cesarean birth prediction was made in two of these five classes. The use of artificial intelligence, through the evaluation of certain obstetric parameters in specific decision-making algorithms, allows physicians to systematically understand how the results of the algorithms can be explained. This approach can be useful in evaluating the progress of labor and predicting the labor outcome, including spontaneous, whether operative VD (vaginal delivery) should be attempted, or if ICD (intrapartum cesarean delivery) is preferable or necessary.
PubMed: 38786561
DOI: 10.3390/jimaging10050107 -
Diagnostics (Basel, Switzerland) May 2024This case concentrates on the persistent left superior vena cava (PLSVC), a rare vascular anomaly which contributes to central venous catheter (CVC) misplacement. A...
This case concentrates on the persistent left superior vena cava (PLSVC), a rare vascular anomaly which contributes to central venous catheter (CVC) misplacement. A 72-year-old woman with renal insufficiency presented to the hospital with recurrent bleeding from her permanent CVC device placed in the right common jugular vein. An initial attempt to replace the device was unsuccessful, necessitating the placement of a secondary catheter in the left jugular vein. Shortly after the procedure, the patient developed swelling of the face and neck. Further diagnostic imaging, including a chest radiograph and computed tomography (CT), revealed CVC misplacement in the PLSVC and coronary sinus, thrombosis of the common jugular vein, and a posterior mediastinal hematoma. Conservative therapy of the mediastinal hematoma was implemented and proved effective in this case. A temporary CVC was inserted into the left femoral vein. Two months later, the catheter underwent further dysfunction and a decision was made to place a long-term permanent CVC via the right femoral vein. The patient is currently awaiting an arteriovenous fistula for dialysis use. This case emphasizes the importance of radiological techniques for CVC procedural placement, as well as the detection of congenital abnormalities. Providers regularly placing CVCs should have an in-depth knowledge of the possible complications and potential anatomical variations, especially as seen in high-risk patients.
PubMed: 38786336
DOI: 10.3390/diagnostics14101038 -
The Journal of Arthroplasty May 2024Hip resurfacing arthroplasty (HRA) is a bone-conserving alternative to total hip arthroplasty. We present the 2-year clinical and radiographic follow-up of a novel...
BACKGROUND
Hip resurfacing arthroplasty (HRA) is a bone-conserving alternative to total hip arthroplasty. We present the 2-year clinical and radiographic follow-up of a novel ceramic-on-ceramic HRA in an international multicenter cohort.
METHODS
Patients undergoing HRA between September 2018 and January 2021 were prospectively included. Patient-reported outcome measures (PROMs) in the form of the Forgotten Joint Score, Hip Disability and Osteoarthritis Outcome Score Jr., Western Ontario and McMaster Universities Arthritis Index, Oxford Hip Score, and University of California, Los Angeles, Activity Score were collected preoperatively, and at 1 and 2 years postoperation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis or loosening, and heterotopic ossification formation.
RESULTS
The study identified 200 patients who reached a minimum 2-year follow-up (mean 3.5 years). Of these, 185 completed PROMs follow-up at 2 years. There was a significant improvement in Hip Disability and Osteoarthritis Outcome Score (P < .001) and Oxford Hip Score (P < .001) between the preoperative, 1-year, and 2-year outcomes. Patients had improved activity scores on the University of California, Los Angeles, Active Score (P < .001), with 45% reporting a return to high-impact activity at 2 years. At 1 and 2 years, the Forgotten Joint Score was not significantly different (P = .38). There was no migration, osteolysis, or loosening of any of the implants. No fractures were reported over the 2-year follow-up, with only 1 patient reporting a sciatic nerve palsy. There were 2 revisions, 1 for unexplained pain at 3 months due to acetabular component malposition and 1 at 33.5 months for acetabular implant failure.
CONCLUSIONS
The ceramic-on-ceramic resurfacing at 2 years postoperation demonstrates promising results with satisfactory outcomes in all recorded PROMs. Further long-term data are needed to support the widespread adoption of this prosthesis as an alternative to other HRA bearings.
PubMed: 38782243
DOI: 10.1016/j.arth.2024.05.042 -
Journal of Plastic, Reconstructive &... Jul 2024Implant rotation is a known complication to breast reconstruction using anatomical implants. However, there is a lack of large studies investigating the risk of implant...
BACKGROUND
Implant rotation is a known complication to breast reconstruction using anatomical implants. However, there is a lack of large studies investigating the risk of implant rotation and potential predisposing risk factors.
METHOD
We reviewed the medical records of all patients who underwent breast reconstruction with Mentor anatomical implants from 2010 to 2021 at two Danish hospitals. We compared the risk of implant rotation between one- and two-stage breast reconstruction using univariate logistic regression. We analyzed the effect of biological mesh, immediate versus delayed reconstruction, and use of a higher final expander volume than the permanent implant volume on the risk of implant rotation. Finally, we analyzed the success rate of revision surgery for implant rotation.
RESULTS
In total, 1134 patients were enrolled. Patients who underwent two-stage breast reconstruction (n = 720) had a significantly higher risk of implant rotation than those who underwent one-stage breast reconstruction (n = 426; 11% vs. 5%, p < 0.01). There was no significant association between implant rotation and the use of biological mesh, immediate breast reconstruction, or use of a higher final expander volume than the permanent implant volume. The success rate of revision surgery after implant rotation was 73% (62/85 rotations).
CONCLUSIONS
Two-stage breast reconstruction significantly increased the risk of implant rotation compared to one-stage breast reconstruction. The overall risk of implant rotation was low and success rate of revision surgery was high. These findings suggest that anatomical implants are safe to use for breast reconstruction. However, surgeons and patients should be aware of the increased risk of implant rotation after two-stage reconstruction.
Topics: Humans; Female; Retrospective Studies; Middle Aged; Breast Implants; Reoperation; Breast Implantation; Adult; Risk Factors; Breast Neoplasms; Postoperative Complications; Mammaplasty; Denmark; Prosthesis Failure
PubMed: 38781835
DOI: 10.1016/j.bjps.2024.05.018 -
JACC. Case Reports Apr 2024Implantation of prosthetic heart valves may result in both early and late complications. Early complications are usually structural and can have significant hemodynamic...
Implantation of prosthetic heart valves may result in both early and late complications. Early complications are usually structural and can have significant hemodynamic consequences. In this clinical vignette, we highlight how malposition of a newly implanted aortic valve resulted in alterations of coronary perfusion pressure physiology and subsequent significant hemodynamic effects.
PubMed: 38774795
DOI: 10.1016/j.jaccas.2024.102278 -
Cureus Apr 2024Chemotherapy is part and parcel of the multimodality approach to cancer treatment. Chemoports are frequently used to administer chemotherapy, preventing complications...
INTRODUCTION
Chemotherapy is part and parcel of the multimodality approach to cancer treatment. Chemoports are frequently used to administer chemotherapy, preventing complications associated with the use of peripheral lines. However, chemoports have their own set of complications and can be very debilitating at times. Accurate knowledge and correct technique can help prevent and manage these complications properly.
METHODS
We retrospectively analyzed all patients who underwent chemoport insertion for chemotherapy infusion over three years between July 2020 and June 2023. The patient's profile, type of cancer, the technique of chemoport insertion, complications related to chemoport, and its management were recorded retrospectively from patient records.
RESULTS
The total number of patients in our study was 119. The age group of patients ranged from 13 years to 76 years. Of the 119 patients, 55 had breast cancer, 23 had ovarian cancers, 29 had GI cancers including gastroesophageal junction (GEJ)/ stomach/periampullary/colorectal, and 12 had leukemias. The most common intraoperative complication was catheter tip malposition (9.2%). The most common postoperative complications were infection (7.5%), followed by drug extravasation (5.0%), thrombosis (3.3%), wound dehiscence (2.5%), and skin necrosis (0.8%) in decreasing order of frequency. Serious complications such as hemothorax, pneumothorax, air emboli, brachial plexus injury, and pericardial tamponade, commonly reported in the literature, were not seen in any of our cases.
CONCLUSION
Totally implanted venous access devices (TIVAD)/chemoports are indispensable in the management of cancer patients, especially in patients requiring long duration of infusion and prolonged treatment. Although chemoports are associated with a spectrum of complications, proper technique of implantation and use makes it a safe and reliable tool.
PubMed: 38738137
DOI: 10.7759/cureus.58052