Arthroscopy : the Journal of... May 2024To evaluate whether the modified suture-button Latarjet procedure with coracoacromial ligament (CAL) and pectoralis minor (PM) preservation could achieve excellent...
Modified Suture-Button Latarjet Procedure With Coracoacromial Ligament and Pectoralis Minor Preservation Achieves Good Clinical Outcomes at 2-Year Follow-Up: Case Series of Latarjet Technique.
PURPOSE
To evaluate whether the modified suture-button Latarjet procedure with coracoacromial ligament (CAL) and pectoralis minor (PM) preservation could achieve excellent outcomes at the 2-year follow-up.
METHODS
During January 2019 to January 2021, the data of patients who underwent modified suture-button Latarjet with CAL and PM preservation in our department were collected. The glenoid bone loss of these patients was greater than 20% or greater than 10% with high demands for exercise. Partial coracoid osteotomy was based on the results of a preoperative 3-dimensional computed tomography evaluation of the glenoid defect area and corresponding coracoid process morphology. The preoperative and postoperative clinical results were assessed. The minimal clinically important difference (MCID) was used to compare improvement in clinical outcomes. Graft-glenoid union and remodeling were assessed using postoperative 3-dimensional computed tomography, and magnetic resonance imaging was performed to confirm the integrity of the CAL and PM postoperatively.
RESULTS
In total, 35 patients were included in this study; the mean follow-up time was 26.9 ± 1.9 months. No case of recurrent dislocation or sublaxity. Significant improvements were observed in mean visual analog scale (VAS) scores for pain during motion, American Shoulder and Elbow Surgeons (ASES) score, Rowe score, and Walch-Duplay score (P < .001). The percentage of patients achieving at least an MCID improvement in clinical outcomes was VAS 85.71%, ASES 97.14%, Rowe 100%, and Walch-Duplay 97.14%. Thirty-three patients (94.3% of all cases) were able to return to their preoperative sport levels, 34 grafts (97.1%) achieved bone union (1 soft union) in 6.3 ± 2.2 months, and the coracoid grafts restored 97.1 ± 4.0% of the perfect-fitting circle at the last follow-up. Postoperative computed tomography scan showed that 31 grafts (88.6%) were placed ideally in vertical view. In the axial view, 25 grafts (82.9%) were flushed to the glenoid, whereas 1 and 5 grafts were fixed medially and laterally, respectively. The CAL and PM were visualized postoperatively. No arthropathy was observed in any patient at the last follow-up.
CONCLUSIONS
The modified suture-button Latarjet procedure with CAL and PM preservation obtained good clinical and radiological results without recurrence or complications. A substantial number of patients (>85%) achieved the MCID for the VAS, ASES, Rowe, and Walch-Duplay scores. In addition, the malpositioned graft (17.1%) did not cause arthropathy of the joints at 2-year follow-up.
LEVEL OF EVIDENCE
Level IV, retrospective case series.
PubMed: 38735417
DOI: 10.1016/j.arthro.2024.04.037 -
Journal of Clinical Medicine Apr 2024Veno-arterial (V-A) and Veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) support is increasingly utilized for acute cardiogenic shock and/or respiratory... (Review)
Review
Veno-arterial (V-A) and Veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) support is increasingly utilized for acute cardiogenic shock and/or respiratory failure. Echocardiography and point-of-care ultrasonography (POCUS) play a critical role in the selection and management of these critically ill patients, however, there are limited guidelines regarding their application. This comprehensive review describes current and potential application of echocardiography and POCUS for pre-ECMO assessment and patient selection, cannulation guidance with emphasis on dual-lumen configurations, diagnosis of ECMO complications and trouble-shooting of cannula malposition, diagnosis of common cardiac or pulmonary pathologies, and assessment of ECMO weaning appropriateness including identification of the aortic mixing point in V-A ECMO.
PubMed: 38731160
DOI: 10.3390/jcm13092630 -
Joint Diseases and Related Surgery Apr 2024This study aims to assess the association between isolated subscapularis tears and coracoid morphology using magnetic resonance imaging (MRI) and to calculate the...
OBJECTIVES
This study aims to assess the association between isolated subscapularis tears and coracoid morphology using magnetic resonance imaging (MRI) and to calculate the optimal cut-off values of the significant predictor to predict subscapularis tears.
PATIENTS AND METHODS
Between January 2018 and December 2022, a total of 60 patients (29 males, 31 females; mean age: 58.4±8.4 years; range, 18 to 80 years) diagnosed with subscapularis tendon tears who were treated as Group A and 60 patients (29 males, 31 females; mean age: 46.8±11.5 years; range, 18 to 80 years) without subscapularis tendon tears who were treated as Group B were included. Axial coracoid-humeral distance (aCHD), sagittal coracoid-humeral distance (sCHD), coracoid overlap (CO) and coracoid angle (CA) of all patients were measured. Logistic regression was used to investigate the association between subscapularis tears as variables including aCHD, sCHD, CO and CA. Receiver operating characteristic curve analysis was used to determine the diagnostic values of coracoid morphology for subscapularis tears.
RESULTS
The mean values of CO, aCHD and sCHD in Group A were 22.16 mm, 5.13 mm, and 5.56 mm, respectively. The mean values in Group B were 16.99 mm, 7.18 mm, and 7.29 mm, respectively. The degree of CA in Group A was 95.81 and 111.69 in Group B. The differences in the above measurement values were significant between two Groups. The CO was found to be associated with higher odds of subscapularis tears. The optimal cut-off value of CO was 19.79 mm.
CONCLUSION
Based on our study results, CO is positively associated with isolated subscapularis tears. In addition, coracoid bursa effusion, cysts in the lesser tuberosity or a tear and malposition of long head of the biceps tendon on MRI may predict the presence of a clinically significant subscapularis tear.
Topics: Humans; Male; Female; Magnetic Resonance Imaging; Middle Aged; Adult; Aged; Adolescent; Coracoid Process; Young Adult; Aged, 80 and over; Rotator Cuff Injuries; China; Retrospective Studies; East Asian People
PubMed: 38727104
DOI: 10.52312/jdrs.2024.1587 -
The Ultrasound Journal May 2024Point-of-care ultrasound (POCUS) has become a mainstay in the evaluation of critically ill patients in the intensive care unit (ICU). ECMO patients are susceptible to...
BACKGROUND
Point-of-care ultrasound (POCUS) has become a mainstay in the evaluation of critically ill patients in the intensive care unit (ICU). ECMO patients are susceptible to complications during prolonged ICU stay, including cannula malposition, which has deleterious consequences. Although the literature surrounding utility of ultrasound on ECMO patients is expansive, direct comparison between radiographic imaging versus ultrasound for identification of cannula malposition is lacking.
CASE PRESENTATION
The authors identified four patients with cannula malposition discovered through POCUS that was missed on routine radiographic imaging. Identification and correction of malposition changed their ECMO course.
CONCLUSION
This case series is the first in literature demonstrating that ultrasound may be superior to radiographic images for ECMO cannula malposition. Further investigation into this subject is warranted.
PubMed: 38717534
DOI: 10.1186/s13089-024-00357-6 -
BMC Pregnancy and Childbirth May 2024The objective of the meta-analysis was to determine the influence of uterine fibroids on adverse outcomes, with specific emphasis on multiple or large (≥ 5 cm in... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
The objective of the meta-analysis was to determine the influence of uterine fibroids on adverse outcomes, with specific emphasis on multiple or large (≥ 5 cm in diameter) fibroids.
MATERIALS AND METHODS
We searched PubMed, Embase, Web of Science, ClinicalTrials.gov, China National Knowledge Infrastructure (CNKI), and SinoMed databases for eligible studies that investigated the influence of uterine fibroids on adverse outcomes in pregnancy. The pooled risk ratio (RR) of the variables was estimated with fixed effect or random effect models.
RESULTS
Twenty-four studies with 237 509 participants were included. The pooled results showed that fibroids elevated the risk of adverse outcomes, including preterm birth, cesarean delivery, placenta previa, miscarriage, preterm premature rupture of membranes (PPROM), placental abruption, postpartum hemorrhage (PPH), fetal distress, malposition, intrauterine fetal death, low birth weight, breech presentation, and preeclampsia. However, after adjusting for the potential factors, negative effects were only seen for preterm birth, cesarean delivery, placenta previa, placental abruption, PPH, intrauterine fetal death, breech presentation, and preeclampsia. Subgroup analysis showed an association between larger fibroids and significantly elevated risks of breech presentation, PPH, and placenta previa in comparison with small fibroids. Multiple fibroids did not increase the risk of breech presentation, placental abruption, cesarean delivery, PPH, placenta previa, PPROM, preterm birth, and intrauterine growth restriction. Meta-regression analyses indicated that maternal age only affected the relationship between uterine fibroids and preterm birth, and BMI influenced the relationship between uterine fibroids and intrauterine fetal death. Other potential confounding factors had no impact on malposition, fetal distress, PPROM, miscarriage, placenta previa, placental abruption, and PPH.
CONCLUSION
The presence of uterine fibroids poses increased risks of adverse pregnancy and obstetric outcomes. Fibroid size influenced the risk of breech presentation, PPH, and placenta previa, while fibroid numbers had no impact on the risk of these outcomes.
Topics: Humans; Female; Pregnancy; Leiomyoma; Pregnancy Outcome; Uterine Neoplasms; Cesarean Section; Premature Birth; Placenta Previa; Postpartum Hemorrhage; Fetal Membranes, Premature Rupture; Pregnancy Complications, Neoplastic; Abortion, Spontaneous; Abruptio Placentae; Breech Presentation; Risk Factors
PubMed: 38710995
DOI: 10.1186/s12884-024-06545-5 -
Hand Surgery & Rehabilitation Jun 2024Total joint replacement has become significantly more common as a treatment for advanced trapeziometacarpal joint osteoarthritis in recent years. The latest generation...
INTRODUCTION
Total joint replacement has become significantly more common as a treatment for advanced trapeziometacarpal joint osteoarthritis in recent years. The latest generation of prostheses with dual-mobility designs leads to very good functional results and low rates of loosening and dislocation in the short and medium term. Biomechanical studies showed that central placement and parallel alignment of the cup with respect to the proximal articular surface of the trapezium are crucial for both cup stability and prevention of dislocation. Despite correct positioning of the guidewire, incorrect placement or tilting of the inserted cup may occur, requiring immediate intraoperative revision.
METHODS
The existing spherical and conical cup models in sizes 9 mm and 10 mm were transferred to a computer-aided design dataset. Depending on the intraoperative complication (tilting or incorrect placement), the revision options resulting from the various combinations of cup type and size were simulated and analyzed according to the resulting defect area and bony contact area.
RESULTS
In well centered cups, a size 9 conical cup could be replaced by a size 9 spherical cup and still be fixed by press-fit. Conversely, a size 9 spherical cup could not be replaced by a size 9 conical cup, but only by a size 10 cup, of whatever shape. When a size 9 conical cup was tilted up to 20°, the best revision option was to resect the sclerotic margin and insert a size 10 conical cup deeper into the cancellous bone, to achieve the largest contact area with the surrounding bone. When a size 9 cup of whatever shape was poorly centered (misplaced with respect to the dorsopalmar or radioulnar line of the trapezium), placement should be corrected using a size 10 cup, combined with autologous bone grafting of the defect. Again, the size 10 conical cup showed the largest bony contact area.
CONCLUSION
Our computer-based measurements suggested options for intraoperative cup revision depending on cup shape and size and on type of misalignment with resulting bone defects. These suggestions, however, need to be confirmed in anatomic specimens before introducing them into clinical practice.
Topics: Humans; Prosthesis Design; Reoperation; Joint Prosthesis; Computer Simulation; Computer-Aided Design; Carpometacarpal Joints; Arthroplasty, Replacement; Prosthesis Failure; Osteoarthritis; Trapezium Bone
PubMed: 38701947
DOI: 10.1016/j.hansur.2024.101712 -
Pediatrics and Neonatology Apr 2024Previous studies on congenital heart diseases (CHD) associated with dextrocardia were based on selective patient databases and did not reflect the full spectrum of...
BACKGROUND
Previous studies on congenital heart diseases (CHD) associated with dextrocardia were based on selective patient databases and did not reflect the full spectrum of dextrocardia in the general population. Additionally, these studies had complex classification and presentation. Nor did these studies elaborate on the distribution of the associated CHD's complexity, the various segmental connections, and associated CHD among the four visceroatrial situs.
METHODS
We retrospectively reviewed the medical records of 211 children with primary dextrocardia. We used a segmental approach to diagnose CHD. We then analyzed and compared the distribution of the above-mentioned issues among the four visceroatrial situs.
RESULTS
Dextrocardia occurred most commonly with situs inversus (52.6%), followed by situs solitus (28.4%), asplenia (17.1%), and polysplenia (1.9%). Although some patients had a structurally normal heart (22.7%) or they were associated with simple CHD (17.5%), most patients had complex CHD (59.7%) consisting of a single ventricle (34.6%) or conotruncal anomaly (25.1%) (double-outlet right ventricle [7.6%], corrected transposition of the great arteries [6.2%], complete transposition of the great arteries [5.7%], tetralogy of Fallot [4.7%], etc.). Situs inversus or polysplenia had a higher prevalence of a structurally normal heart or associated with simple CHD, two patent atrioventricular (AV) valves connections, and biventricular AV connections. Situs solitus or asplenia had a higher prevalence of associated complex CHD, common AV valve connection, univentricular AV connection, pulmonary outflow tract obstruction, and anomalous pulmonary venous drainage.
CONCLUSION
Our study finds that situs inversus is the most common visceroatrial situs in dextrocardia. Although some patients had a structurally normal heart or were associated with simple CHD, most patients have associated complex CHD consisting of a single ventricle or conotruncal anomaly. Dextrocardia is associated with a higher incidence of complex CHD in situs solitus and asplenia groups than in situs inversus and polysplenia groups.
PubMed: 38692948
DOI: 10.1016/j.pedneo.2023.10.011 -
Journal of Neurosurgery. Case Lessons Apr 2024Central venous catheters (CVCs) play an indispensable role in clinical practice. Catheter malposition and tip migration can lead to severe complications. The authors...
BACKGROUND
Central venous catheters (CVCs) play an indispensable role in clinical practice. Catheter malposition and tip migration can lead to severe complications. The authors present a case illustrating the endovascular management of inadvertent marginal sinus cannulation after an internal jugular vein (IJV) catheter tip migration.
OBSERVATIONS
A triple-lumen CVC was inserted without complications into the right IJV of a patient undergoing a repeat sternotomy for aortic valve replacement. Two weeks postinsertion, it was discovered that the tip had migrated superiorly, terminating below the torcula in the posterior fossa. In the interventional suite, a three-dimensional venogram confirmed the inadvertent marginal sinus cannulation. The catheter was carefully retracted to the sigmoid sinus to preserve the option of catheter exchange if embolization became necessary. After a subsequent venogram, which displayed an absence of contrast extravasation, the entire catheter was safely removed. The patient tolerated the procedure well.
LESSONS
Clinicians must be vigilant of catheter tip migration and malposition risks. Relying solely on postinsertion radiographs is insufficient. Once identified, prompt management of the malpositioned catheter is paramount in reducing morbidity and mortality and improving patient outcomes. Removing a malpositioned catheter constitutes a critical step, best performed by a specialized team under angiographic visualization.
PubMed: 38684119
DOI: 10.3171/CASE23607 -
Journal of Pediatric and Adolescent... Apr 2024Telemedicine for long-acting reversible contraception (LARC) care is understudied given the rapid implementation of these services in response to the COVID-19 pandemic....
STUDY OBJECTIVE
Telemedicine for long-acting reversible contraception (LARC) care is understudied given the rapid implementation of these services in response to the COVID-19 pandemic. We compared outcomes over 1 year of adolescents and young adults (AYAs) attending a LARC post-insertion visit via telemedicine vs in person.
DESIGN
Longitudinal cohort study.
SETTING
Four academic adolescent medicine clinics in the United States.
PARTICIPANTS
AYAs (ages 13-26 years) who received LARC between 4/1/20 and 3/1/21 and attended a post-insertion visit within 12 weeks.
INTERVENTIONS
none.
MAIN OUTCOME MEASURES
Outcomes over 1 year were compared between AYAs who completed this visit via telemedicine vs in person. We analyzed the data using descriptive statistics, bivariate analyses, and regression models.
RESULTS
Of 194 AYAs (ages 13.9-25.7 years) attending a post-insertion visit, 40.2% utilized telemedicine. Menstrual management (odds ratio (OR) = 1.02; confidence interval (CI): 0.40-2.60), acne management (P = .28), number of visits attended (relative risk (RR) = 1.08; CI: 0.99-1.19), and LARC removal (P = .95) were similar between groups. AYAs attending via telemedicine were less likely than those attending in person to have STI testing (P = .001). Intrauterine device expulsion or malposition and arm symptoms with implant in situ were rare outcomes in both groups.
CONCLUSION
Roughly 40% of AYAs attended a post-insertion visit via telemedicine during the first year of the COVID-19 pandemic and had similar 1-year outcomes as those attending in person. The decreased likelihood of STI testing for those using telemedicine highlights the need to provide alternative options, when indicated, such as asynchronous or home testing. Our results support the use of telemedicine for AYA LARC post-insertion care and identify potential gaps in telemedicine care which can help improve clinic protocols.
PubMed: 38679156
DOI: 10.1016/j.jpag.2024.04.004 -
CVIR Endovascular Apr 2024This study aimed to assess the effectiveness and versatility of an intentional early detachment technique with detachable coils in addressing challenging vascular...
BACKGROUND
This study aimed to assess the effectiveness and versatility of an intentional early detachment technique with detachable coils in addressing challenging vascular embolization scenarios. This novel approach aims to provide an alternative method for achieving precise coil placement when standard methods of detachable coil placement are ineffective owing to vascular anatomy or limited available equipment.
MATERIALS AND METHODS
This retrospective study included 11 patients (nine males and two females; median age, 77 years) who underwent embolization procedures between October 2021 and December 2023 using the intentional early detachment technique through 1.6-Fr or 1.3-Fr microcatheters. In this technique, detachable coils were intentionally detached within the microcatheter and placed through saline flushing. The technique's technical success, complications, and clinical success were evaluated.
RESULTS
The technique was applied in three distinct scenarios: tortuous vascular anatomy (four cases), inadequate system backup (three cases), and 1.3-Fr microcatheter use (four cases). The technical and clinical success rates were 100%. No complications were observed, and no cases of coil migration or malpositioning.
CONCLUSION
The intentional early detachment technique is valuable for interventional radiologists and offers a solution for challenging vascular embolization scenarios. Its application is limited to specific circumstances; however, it can significantly enhance coil placement in complex cases, thereby contributing to improved patient care.
PubMed: 38662076
DOI: 10.1186/s42155-024-00453-7