Micromachines Jun 2024This study developed a novel dielectric wetting microfluidic operation platform combining parallel-plate and coplanar-plate regions with a curved surface structure as...
This study developed a novel dielectric wetting microfluidic operation platform combining parallel-plate and coplanar-plate regions with a curved surface structure as the connection structure. With the new electrowetting on dielectric (EWOD) platform, "droplet pull-out" has been successfully achieved and viewed as an essential new operation for microfluidics with the dielectric wetting technique. The EWOD system is divided into a PDMS substrate top plate and an indium tin oxide (ITO) glass substrate as a bottom layer on this chip. In the parallel-plate region, the droplets can be generated and transported through the square parallel electrodes; in the single-plate area, the droplets can be pulled out from the parallel structure, transported and mixed through the common grounded coplanar electrodes. In dielectric wetting performance testing, coplanar electrodes can apply a maximum driving force of 31.22 µN to DI water and 13.38 µN to propylene carbonate (PC). This driving force is sufficient to detach the sample from the top cover and pull the sub-droplet from the parallel plate structure for DI water, PC and polyethylene glycol diacrylate (PEGDA) buffer. The novel EWOD system also possesses the advantage of precise volume control for liquid samples; the volume error of the generated droplet can be controlled within 0.1% to 2%.
PubMed: 38930767
DOI: 10.3390/mi15060797 -
Micromachines Jun 2024Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high...
Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have been performed to empirically and computationally study hemolysis in medical devices, such as valves and blood pumps, little is known about blood damage in microfluidic devices. In this study, four variants of a representative microfluidic membrane-based oxygenator and two controls (positive and negative) are introduced, and computational models are used to predict hemolysis. The simulations were performed in ANSYS Fluent for nine shear stress-based parameter sets for the power law hemolysis model. We found that three of the nine tested parameters overpredict (5 to 10×) hemolysis compared to empirical experiments. However, three parameter sets demonstrated higher predictive accuracy for hemolysis values in devices characterized by low shear conditions, while another three parameter sets exhibited better performance for devices operating under higher shear conditions. Empirical testing of the devices in a recirculating loop revealed levels of hemolysis significantly lower (<2 ppm) than the hemolysis ranges observed in conventional oxygenators (>10 ppm). Evaluating the model's ability to predict hemolysis across diverse shearing conditions, both through empirical experiments and computational validation, will provide valuable insights for future micro ECMO device development by directly relating geometric and shear stress with hemolysis levels. We propose that, with an informed selection of hemolysis parameters based on the shear ranges of the test device, computational modeling can complement empirical testing in the development of novel high-flow blood-contacting microfluidic devices, allowing for a more efficient iterative design process. Furthermore, the low device-induced hemolysis measured in our study at physiologically relevant flow rates is promising for the future development of microfluidic oxygenators and dialyzers.
PubMed: 38930760
DOI: 10.3390/mi15060790 -
Micromachines Jun 2024In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens...
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.
PubMed: 38930725
DOI: 10.3390/mi15060755 -
Micromachines Jun 2024This work reports a simple bubble generator for the high-speed generation of microbubbles with constant cumulative production. To achieve this, a gas-liquid co-flowing...
This work reports a simple bubble generator for the high-speed generation of microbubbles with constant cumulative production. To achieve this, a gas-liquid co-flowing microfluidic device with a tiny capillary orifice as small as 5 μm is fabricated to produce monodisperse microbubbles. The diameter of the microbubbles can be adjusted precisely by tuning the input gas pressure and flow rate of the continuous liquid phase. The co-flowing structure ensures the uniformity of the generated microbubbles, and the surfactant in the liquid phase prevents coalescence of the collected microbubbles. The diameter coefficient of variation (CV) of the generated microbubbles can reach a minimum of 1.3%. Additionally, the relationship between microbubble diameter and the gas channel orifice is studied using the low Capillary number () and Weber number () of the liquid phase. Moreover, by maintaining a consistent gas input pressure, the CV of the cumulative microbubble volume can reach 3.6% regardless of the flow rate of the liquid phase. This method not only facilitates the generation of microbubbles with morphologic stability under variable flow conditions, but also ensures that the cumulative microbubble production over a certain period of time remains constant, which is important for the volume-dominated application of chromatographic analysis and the component analysis of natural gas.
PubMed: 38930722
DOI: 10.3390/mi15060752 -
Micromachines May 2024Modern microtechnology methods are widely used to create neural networks on a chip with a connection architecture demonstrating properties of modularity and hierarchy...
Modern microtechnology methods are widely used to create neural networks on a chip with a connection architecture demonstrating properties of modularity and hierarchy similar to brain networks. Such in vitro networks serve as a valuable model for studying the interplay of functional architecture within modules, their activity, and the effectiveness of inter-module interaction. In this study, we use a two-chamber microfluidic platform to investigate functional connectivity and global activity in hierarchically connected modular neural networks. We found that the strength of functional connections within the module and the profile of network spontaneous activity determine the effectiveness of inter-modular interaction and integration activity in the network. The direction of intermodular activity propagation configures the different densities of inhibitory synapses in the network. The developed microfluidic platform holds the potential to explore function-structure relationships and efficient information processing in two- or multilayer neural networks, in both healthy and pathological states.
PubMed: 38930702
DOI: 10.3390/mi15060732 -
Micromachines May 2024By leveraging the benefits of a high energy density, miniaturization and integration, acoustic-wave-driven micromotors have recently emerged as powerful tools for...
By leveraging the benefits of a high energy density, miniaturization and integration, acoustic-wave-driven micromotors have recently emerged as powerful tools for microfluidic actuation. In this study, a Lamb-wave-driven micromotor is proposed for the first time. This motor consists of a ring-shaped Lamb wave actuator array with a rotor and a fluid coupling layer in between. On a driving mechanism level, high-frequency Lamb waves of 380 MHz generate strong acoustic streaming effects over an extremely short distance; on a mechanical design level, each Lamb wave actuator incorporates a reflector on one side of the actuator, while an acoustic opening is incorporated on the other side to limit wave energy leakage; and on electrical design level, the electrodes placed on the two sides of the film enhance the capacitance in the vertical direction, which facilitates impedance matching within a smaller area. As a result, the Lamb-wave-driven solution features a much lower driving voltage and a smaller size compared with conventional surface acoustic-wave-driven solutions. For an improved motor performance, actuator array configurations, rotor sizes, and liquid coupling layer thicknesses are examined via simulations and experiments. The results show the micromotor with a rotor with a diameter of 5 mm can achieve a maximum angular velocity of 250 rpm with an input voltage of 6 V. The proposed micromotor is a new prototype for acoustic-wave-driven actuators and demonstrates potential for lab-on-a-chip applications.
PubMed: 38930686
DOI: 10.3390/mi15060716 -
Micromachines May 2024Circulating tumor cells (CTCs), derived from the primary tumor and carrying genetic information, contribute significantly to the process of tumor metastasis. The... (Review)
Review
Circulating tumor cells (CTCs), derived from the primary tumor and carrying genetic information, contribute significantly to the process of tumor metastasis. The analysis and detection of CTCs can be used to assess the prognosis and treatment response in patients with tumors, as well as to help study the metastatic mechanisms of tumors and the development of new drugs. Since CTCs are very rare in the blood, it is a challenging problem to enrich CTCs efficiently. In this paper, we provide a comprehensive overview of microfluidics-based enrichment devices for CTCs in recent years. We explore in detail the methods of enrichment based on the physical or biological properties of CTCs; among them, physical properties cover factors such as size, density, and dielectric properties, while biological properties are mainly related to tumor-specific markers on the surface of CTCs. In addition, we provide an in-depth description of the methods for enrichment of single CTCs and illustrate the importance of single CTCs for performing tumor analyses. Future research will focus on aspects such as improving the separation efficiency, reducing costs, and increasing the detection sensitivity and accuracy.
PubMed: 38930676
DOI: 10.3390/mi15060706 -
Micromachines May 2024Particle trapping and enrichment into confined volumes can be useful in particle processing and analysis. This review is an evaluation of the methods used to trap and... (Review)
Review
Particle trapping and enrichment into confined volumes can be useful in particle processing and analysis. This review is an evaluation of the methods used to trap and enrich particles into constrained volumes in microfluidic and nanofluidic systems. These methods include physical, optical, electrical, magnetic, acoustic, and some hybrid techniques, all capable of locally enhancing nano- and microparticle concentrations on a microscale. Some key qualitative and quantitative comparison points are also explored, illustrating the specific applicability and challenges of each method. A few applications of these types of particle trapping are also discussed, including enhancing biological and chemical sensors, particle washing techniques, and fluid medium exchange systems.
PubMed: 38930668
DOI: 10.3390/mi15060699 -
Micromachines May 2024Conventional microfluidic systems that rely on capillary force have a fixed structure and limited sensitivity, which cannot meet the demands of clinical applications....
Conventional microfluidic systems that rely on capillary force have a fixed structure and limited sensitivity, which cannot meet the demands of clinical applications. Herein, we propose a dual-drive microfluidic device for sensitive and flexible detection of multiple pathogenic microorganisms antigens/antibodies. The device comprises a portable microfluidic analyzer and a dual-drive microfluidic chip. Along with capillary force, a second active driving force is provided by a removable self-driving valve in the waste chamber. The interval between these two driving forces can be adjusted to control the reaction time in the microchannel, optimizing the formation of antigen-antibody complexes and enhancing sensitivity. Moreover, the material used in the self-driving valve can be changed to adjust the active force strength needed for different tests. The device offers quantitative analysis for respiratory syncytial virus antigen and SARS-CoV-2 antigen using a 35 μL sample, delivering results within 5 min. The detection limits of the system were 1.121 ng/mL and 0.447 ng/mL for respiratory syncytial virus recombinant fusion protein and SARS-CoV-2 recombinant nucleoprotein, respectively. Although the dual-drive microfluidic device has been used for immunoassay for respiratory syncytial virus and SARS-CoV-2 in this study, it can be easily adapted to other immunoassay applications by changing the critical reagents.
PubMed: 38930655
DOI: 10.3390/mi15060685 -
Micromachines May 2024MEMS devices are more and more commonly used as sensors, actuators, and microfluidic devices in different fields like electronics, opto-electronics, and biomedical... (Review)
Review
MEMS devices are more and more commonly used as sensors, actuators, and microfluidic devices in different fields like electronics, opto-electronics, and biomedical engineering. Traditional fabrication technologies cannot meet the growing demand for device miniaturisation and fabrication time reduction, especially when customised devices are required. That is why additive manufacturing technologies are increasingly applied to MEMS. In this review, attention is focused on the Italian scenario in regard to 3D-printed MEMS, studying the techniques and materials used for their fabrication. To this aim, research has been conducted as follows: first, the commonly applied 3D-printing technologies for MEMS manufacturing have been illustrated, then some examples of 3D-printed MEMS have been reported. After that, the typical materials for these technologies have been presented, and finally, some examples of their application in MEMS fabrication have been described. In conclusion, the application of 3D-printing techniques, instead of traditional processes, is a growing trend in Italy, where some exciting and promising results have already been obtained, due to these new selected technologies and the new materials involved.
PubMed: 38930648
DOI: 10.3390/mi15060678