Journal of Clinical Medicine Jun 2024Blowout fractures are common midfacial fractures in which one or several of the bones of orbital vault break. This is usually caused by a direct trauma to the eye with a...
Blowout fractures are common midfacial fractures in which one or several of the bones of orbital vault break. This is usually caused by a direct trauma to the eye with a blunt object such as a fist. Fracturing of the fragile orbital bones can lead to changes in the orbital volume, which may cause enophthalmos, diplopia, and impaired facial aesthetics. : The aim of this study is to investigate whether there is an association between volume change of the bony orbit and age, gender, or trauma mechanism. : A retrospective study of patients with unilateral blowout or blow-in fractures treated and examined in Päijät-Häme Central Hospital, Lahti, Finland was conducted. Altogether, 127 patients met the inclusion criteria. Their computed tomographs (CT) were measured with an orbit-specific automated segmentation-based volume measurement tool, and the relative orbital volume change between fractured and intact orbital vault was calculated. Thereafter, a statistical analysis was performed. A -value less than 0.05 was considered significant. : We found that relative increase in orbital volume and age have a statistically significant association ( = 0.022). Trauma mechanism and gender showed no significant role. : Patient's age is associated with increased volume change in fractures of the bony orbit.
PubMed: 38930147
DOI: 10.3390/jcm13123618 -
Diagnostics (Basel, Switzerland) Jun 2024Orbital floor fractures (OFFs) represent an interesting chapter in maxillofacial surgery, and one of the main challenges in orbit reconstruction is shaping and cutting...
Classical Orbital Floor Post-Traumatic Reconstruction vs. Customized Reconstruction with the Support of "In-House" 3D-Printed Models: A Retrospective Study with an Analysis of Volumetric Measurement.
BACKGROUND
Orbital floor fractures (OFFs) represent an interesting chapter in maxillofacial surgery, and one of the main challenges in orbit reconstruction is shaping and cutting the precise contour of the implants due to its complex anatomy.
OBJECTIVE
The aim of the retrospective study was to demonstrate, through pre- and postoperative volumetric measurements of the orbit, how the use of a preformed titanium mesh based on the stereolithographic model produced with 3D printers ("In-House" reconstruction) provides a better reconstruction volumetric compared to the intraoperatively shaped titanium mesh.
MATERIALS AND METHODS
The patients with OFF enrolled in this study were divided into two groups according to the inclusion criteria. In Group 1 (G1), patients surgically treated for OFF were divided into two subgroups: G1a, patients undergoing orbital floor reconstruction with an intraoperatively shaped mesh, and G1b, patients undergoing orbital floor reconstruction with a preoperative mesh shaped on a 3D-printed stereolithographic model. Group 2 (G2) consisted of patients treated for other traumatic pathologies (mandible fractures and middle face fractures not involving orbit). Pre- and postoperative orbital volumetric measurements were performed on both G1 and G2. The patients of both groups were subjected to the measurement of orbital volume using Osirix software (Pixmeo SARL, CH-1233 Bernex, Switzerland) on the new CT examination. Both descriptive (using central tendency indices such as mean and range) and regressive (using the Bravais-Pearson index, calculated using the GraphPad program) statistical analyses were performed on the recorded data.
RESULTS
From 1 January 2017 to 31 December 2021, of the 176 patients treated for OFF at the "Magna Graecia" University Hospital of Catanzaro 10 fulfilled the study's inclusion criteria: 5 were assigned to G1a and 5 to G1b, with a total of 30 volumetric measurements. In G2, we included 10 patients, with a total of 20 volumetric measurements. From the volumetric measurements and statistical analysis carried out, it emerged that the average of the volumetric differences of the healthy orbits was ±0.6351 cm, the standard deviation of the volumetric differences was ±0.3383, and the relationship between the treated orbit and the healthy orbit was linear; therefore, the treated orbital volumes tend to approach the healthy ones after surgical treatment.
CONCLUSION
This study demonstrates that if the volume is restored within the range of the standardized mean, the diplopia is completely recovered already after surgery or after one month. For orbital volumes that do not fall within this range, functional recovery could occur within 6 months or be lacking. The restoration of the orbital volume using pre-modeled networks on the patient's anatomical model, printed internally in 3D, allows for more accurate reconstructions of the orbital floor in less time, with clinical advantages also in terms of surgical timing.
PubMed: 38928663
DOI: 10.3390/diagnostics14121248 -
Journal of Functional Biomaterials May 2024This contribution gives basic information about the mechanical behavior of the facial part of the human skull cranium, i.e., the splanchnocranium, associated with...
This contribution gives basic information about the mechanical behavior of the facial part of the human skull cranium, i.e., the splanchnocranium, associated with external loads and injuries caused mainly by brachial violence. The main areas suffering from such violence include the orbit, frontal, and zygomatic bones. In this paper, as a first approach, brachial violence was simulated via quasi-static compression laboratory tests, in which cadaveric skulls were subjected to a load in a testing machine, increasing till fractures occurred. The test skulls were also used for research into the dynamic behavior, in which experimental and numerical analyses were performed. A relatively high variability in forces inducing the fractures has been observed (143-1403 N). The results lay the basis for applications mainly in forensic science, surgery, and ophthalmology.
PubMed: 38921517
DOI: 10.3390/jfb15060143 -
Annals of Anatomy = Anatomischer... Jun 2024Orbital floor fractures result in critical changes in the shape and inferior rectus muscle (IRM) position. Radiological imaging of IRM changes can be used for surgical...
BACKGROUND
Orbital floor fractures result in critical changes in the shape and inferior rectus muscle (IRM) position. Radiological imaging of IRM changes can be used for surgical decision making or prediction of ocular symptoms. Studies with a systematic consideration of the orbital floor defect ratio in this context are missing in the literature. Accordingly, this study on human cadavers aimed to systematically investigate the impact of the orbital floor defect ratio on changes in the IRM and the prediction of posttraumatic enophthalmos.
METHODS
Seventy-two orbital floor defects were placed in cadaver specimens using piezosurgical removal. The orbital defect area (ODA), orbital floor area (OFA), position and IRM shape, and enophthalmos were measured using computed tomography (CT) scans.
RESULTS
The ODA/OFA ratio correlated significantly (p < 0.001) with the shape (Spearman's rho: 0.558) and position (Spearman's rho: 0.511) of the IRM, and with enophthalmos (Spearman's rho: 0.673). Increases in the ODA/OFA ratio significantly rounded the shape of the IRM (ß: 0.667; p < 0.001) and made a lower position of the IRM more likely (OR: 1.093; p = 0.003). In addition, increases in the ODA/OFA ratio were significantly associated with the development of relevant enophthalmos (OR: 1.159; p = 0.008), adjusted for the defect localization and shape of the IRM. According to receiver operating characteristics analysis (AUC: 0.876; p < 0.001), a threshold of ODA/OFA ratio ≥ 32.691 for prediction of the risk of development of enophthalmos yielded a sensitivity of 0.809 and a specificity of 0.842.
CONCLUSION
The ODA/OFA ratio is a relevant parameter in the radiological evaluation of orbital floor fractures, as it increases the risk of relevant enophthalmos, regardless of fracture localization and shape of the IRM. Therefore, changes in the shape and position of the IRM should be considered in surgical treatment planning. A better understanding of the correlates of isolated orbital floor fractures may help to develop diagnostic scores and standardize therapeutic algorithms in the future.
PubMed: 38889825
DOI: 10.1016/j.aanat.2024.152294 -
Clinical Case Reports Jun 2024The most frequently reported adverse reaction to zoledronic acid is an acute phase reaction resembling influenza. While rarer adverse events such as osteonecrosis of the...
The most frequently reported adverse reaction to zoledronic acid is an acute phase reaction resembling influenza. While rarer adverse events such as osteonecrosis of the jaw and atypical femoral fractures have gained significant recognition, the ocular adverse effects, particularly scleritis, are not yet fully comprehended. Here, we present the case of a 75-year-old female patient with osteoporosis who developed bilateral redness and intense eye pain 48 h after receiving a 5 mg intravenous dose of zoledronic acid. Clinical presentation suggested bilateral conjunctivitis, but treatment with levofloxacin eye drops and acyclovir ophthalmic gel exacerbated the symptoms over 2 days, predominantly affecting the left eye. Ocular ultrasonography revealed thickening of the left eyeball wall with a "T" sign, while an orbital CT scan showed increased thickness of the left sclera. Treatment with methylprednisolone 80 mg intravenous infusion twice daily led to gradual symptom improvement and eventual resolution of inflammation. This report, based on a review of relevant literature, investigates the treatment and outcomes of zoledronic acid-induced scleritis, emphasizing the importance for clinicians to promptly identify and manage this rare and serious ocular adverse reaction.
PubMed: 38855089
DOI: 10.1002/ccr3.9068 -
Cureus Apr 2024Zygomaticomaxillary complex (ZMC) fractures typically result from traumatic injuries, such as motor vehicle-related incidents, assaults, falls, and sports-related...
Zygomaticomaxillary complex (ZMC) fractures typically result from traumatic injuries, such as motor vehicle-related incidents, assaults, falls, and sports-related injuries. These fractures characteristically occur along suture lines where the zygomatic bone borders the frontal bone, maxilla, temporal bone, and sphenoid bone, resulting in a "tetrapod" fracture pattern that can be surgically fixated utilizing one, two, and three-point plate and screw fixation. However, fractures with complete loss of bone stock are less common, and standardized methods of fixation are not suitable for such complex fractures. Here, we present an interesting case of implantation of a custom-made alloplastic implant in a patient with complex ZMC fractures with loss of bone stock. A 52-year-old male sustained a traumatic gunshot wound to the face, resulting in significant destruction of bones involving the left orbital floor, left lateral orbital wall, and left zygomatic arch. Routine plating was not feasible, so a custom spanning plating system by DePuy Synthes (Synthes USA Products, LLC, West Chester, PA) was designed using the patient's CT scans. The patient recovered well with no complications. This case illustrates the successful application of patient-specific custom plates for complex ZMC fractures when standard plating methods are not suitable.
PubMed: 38817507
DOI: 10.7759/cureus.59379 -
The Journal of Craniofacial Surgery May 2024Orbital walls are one of the most common sites of midface fractures and account for ~40% of traumatic injuries in this region. These fractures are often associated with...
Orbital walls are one of the most common sites of midface fractures and account for ~40% of traumatic injuries in this region. These fractures are often associated with changes in the anatomy of the orbital cavity and frequently affect the orbital inferior wall, infraorbital groove and canal, and medial orbital wall, which leads to changes in its pattern and volume as well. Generally, the forces required for brake superior and lateral walls are greater than those required for thin medial and inferior walls. Disruption of any of these structures leads to the expansion of orbital volume that brings to the appearance of enophthalmos, diplopia, and impaired ocular mobility. The gold standard in the treatment of orbital wall fractures is surgical reconstruction, that includes fracture site exposure, freeing tissue prolapsed into the fracture site, and re-approximating the orbital wall support, usually with an orbital implant. It usually could be achieved by the usage of such as transconjunctival, subciliary, and coronal approaches and implementation of graft and reconstructive materials, including bones, cartilage, titanium, and resorbable mesh. Today, the gold standard in orbital floor reconstruction is the application of titanium mesh orbital plates. However, their implementation could be associated with a number of postoperative complications, such as mispositioning and orbital adherence syndrome. Orbital adherence syndrome is a poorly described and understood phenomenon and appears to occur after the use of large-pored titanium mesh for orbital reconstruction. It usually appears as limited eye movement that appears 1 to 2 weeks after reconstructive procedure. Prevention is possible through careful patient selection and the placement of a smooth interface medium in the initial surgery. The aim of the current study is to present the outcomes of orbital reconstruction done by both orbital mesh and customized smooth-surfaced titanium orbital implants.
PubMed: 38809031
DOI: 10.1097/SCS.0000000000010143 -
Plastic and Reconstructive Surgery.... May 2024Superior orbital fissure syndrome (SOFS) is a rare complication of craniofacial fracture, caused by damage to cranial nerves Ⅲ, Ⅳ, Ⅴ, and Ⅵ, which typically is...
Superior orbital fissure syndrome (SOFS) is a rare complication of craniofacial fracture, caused by damage to cranial nerves Ⅲ, Ⅳ, Ⅴ, and Ⅵ, which typically is associated with ophthalmoplegia, blepharoptosis, pupil dilatation and fixation, and upper eyelid and forehead hypesthesia. However, we here describe a very unusual case of craniofacial fracture with SOFS in the absence of pupil symptoms, involving a patient who was injured when he fell while riding his bicycle. Upon medical examination, we observed mild blepharoptosis and ophthalmoplegia of the right eye without pupillary symptoms. Computed tomography (CT) revealed basal skull and zygomatic fractures. After the patient had been treated conservatively for his skull base fracture, facial bone reduction was performed at our hospital. Because ophthalmoplegia and blepharoptosis remained after the surgery, we checked the preoperative CT images again and discovered stenosis of the superior orbital fissure. Postoperative CT revealed a widening of the superior orbital fissure after the facial bone reduction, and therefore, the patient was given steroid treatment without additional surgery. At 6 months postoperatively, the cranial nerves had completely recovered. Our finding emphasizes that, in contrast to common theory, trauma-induced SOFS can result in pupil-sparing oculomotor nerve palsy.
PubMed: 38798927
DOI: 10.1097/GOX.0000000000005828 -
Journal of Personalized Medicine Apr 2024Enophthalmos is a severe complication of primary reconstruction following orbital floor fractures, oncological resections, or maxillo-facial syndromes. The goal of...
Enophthalmos is a severe complication of primary reconstruction following orbital floor fractures, oncological resections, or maxillo-facial syndromes. The goal of secondary orbital reconstruction is to regain a symmetrical globe position to restore function and aesthetics. In this article, we present a method of computer-assisted orbital floor reconstruction using a mirroring technique and a custom-made titanium or high-density polyethylene mesh printed using computer-aided manufacturing techniques. This reconstructive protocol involves four steps: mirroring of the healthy orbit computer tomography files at the contralateral affected site, virtual design of a customized implant, computer-assisted manufacturing (CAM) of the implant using Direct Metal Laser Sintering (DMLS) or Computer Numerical Control (CNC) methods, and surgical insertion of the device. Clinical outcomes were assessed using 3dMD photogrammetry and computed tomography measures in 13 treated patients and compared to a control group treated with stock implants. An improvement of 3.04 mm (range 0.3-6 mm) in globe protrusion was obtained for the patients treated with patient-specific implants (PSI), and no major complications have been registered. The technique described here appears to be a viable method for correcting complex orbital floor defects needing delayed reconstruction.
PubMed: 38793041
DOI: 10.3390/jpm14050459 -
Frontiers in Bioengineering and... 2024In this study, we attempted to demonstrate the actual process of orbital floor fracture visually and computationally in anatomically reconstructed structures and to...
In this study, we attempted to demonstrate the actual process of orbital floor fracture visually and computationally in anatomically reconstructed structures and to investigate them using finite element analysis. A finite element model of the skull and cervical vertebrae was reconstructed from computed tomography data, and an eyeball surrounded by extraocular adipose was modeled in the orbital cavity. Three-dimensional volume mesh was generated using 173,894 of the 4-node hexahedral solid elements. For the cases where the impactor hit the infraorbital foramen, buckling occurred at the orbital bone as a result of the compressive force, and the von Mises stress exceeded 150 MPa. The range of stress components included inferior orbital rim and orbital floor. For the cases where the impactor hit the eyeball first, the orbital bone experienced less stress and the range of stress components limited in orbital floor. The critical speeds for blowout fracture were 4 m/s and 6 m/s for buckling and hydraulic mechanism. Each mechanism has its own fracture inducing energy and its transmission process, type of force causing the fracture, and fracture pattern. It is possible to determine the mechanism of the fracture based on whether an orbital rim fracture is present.
PubMed: 38774815
DOI: 10.3389/fbioe.2024.1354944