-
BMC Oral Health Jun 2024Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs... (Comparative Study)
Comparative Study
BACKGROUND
Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs without detrimentally affecting their physical properties and biocompatibility. This study compared the chemical and mechanical properties, as well as the cytotoxicity, of elastomeric micelles-containing glass ionomer cement (DeltaFil, DT) with commonly used materials, including EQUIA Forte Fil (EF), Fuji IX GP Extra (F9), and Ketac Molar (KT).
METHOD
Powder particles of GICs were examined with SEM-EDX. Setting kinetics were assessed using ATR-FTIR. Biaxial flexural strength/modulus and Vickers surface microhardness were measured after immersion in water for 24 h and 4 weeks. The release of F, Al, Sr, and P in water over 8 weeks was analyzed using a fluoride-specific electrode and ICP-OES. The toxicity of the material extract on mouse fibroblasts was also evaluated.
RESULTS
High fluoride levels in the powder were detected with EF and F9. DT demonstrated an initial delay followed by a faster acid reaction compared to other cements, suggesting an improved snap set. DT also exhibited superior flexural strength than other materials at both 24 h and 4 weeks but lower surface microhardness (p < 0.05). EF and F9 showed higher release of F, Al, and P than DT and KT. There was no statistically significant difference in fibroblast viability among the tested materials (p > 0.05).
CONCLUSIONS
Elastomeric micelles-containing glass ionomer cement (DT) exhibited satisfactory mechanical properties and cytocompatibility compared with other materials. DT could, therefore, potentially be considered an alternative high-strength GIC for load-bearing restorations.
Topics: Glass Ionomer Cements; Animals; Mice; Materials Testing; Micelles; Fibroblasts; Hardness; Elastomers; Flexural Strength; Aluminum; Fluorides; Strontium; Polycarboxylate Cement; Cell Survival; Microscopy, Electron, Scanning; Surface Properties; Pliability; Kinetics; Spectroscopy, Fourier Transform Infrared; Stress, Mechanical; Time Factors; Biocompatible Materials
PubMed: 38902666
DOI: 10.1186/s12903-024-04468-3 -
The Pan African Medical Journal 2024anorectal malformations (ARM) are among the most common congenital anomalies in pediatric surgery. Early detection and management of vestibular fistulas are crucial for...
INTRODUCTION
anorectal malformations (ARM) are among the most common congenital anomalies in pediatric surgery. Early detection and management of vestibular fistulas are crucial for optimal outcomes, capitalizing on the pliability of sphincter muscles and the preservation of somatosensory integration. This study aimed to assess the incidence, clinical presentation, and management outcomes of vestibular fistula ARM in a low-income hospital setting.
METHODS
a retrospective audit was conducted on female pediatric patients aged up to 12 years treated for vestibular fistula ARM from January 1, 2011, to June 30, 2016. Data were collected from medical records, and patients were categorized into one of three surgical management groups. Clinical assessments, preoperative procedures, and surgical interventions were meticulously documented.
RESULTS
among 656 neonates, the incidence of vestibular fistula ARM was 8.2%. Patients presented at various ages, with 69.4% being early presenters. Notably, 11.1% of cases presented after 30 weeks of age. Functional fistula, constipation, and bowel obstruction were common presenting symptoms. Associated anomalies were relatively low. The choice of surgical approach varied, with a predominant 3-stage at 68%. Complication development did not significantly differ between surgical groups (p-value 0.083). Immediate postoperative complications were minimal, but complications at definitive anoplasty varied among the surgical groups. Anal strictures and fistula recurrence were noted. At 12 months post-surgery, anal strictures persisted in 9 participants.
CONCLUSION
this study highlights the challenges and outcomes associated with vestibular fistula ARM in a resource-constrained setting. The 3-stage approach, despite its historical preference, demonstrated suboptimal outcomes. A 2-stage procedure appears to offer a balanced alternative, particularly suitable for low-income healthcare systems. Further research and collaborative efforts are essential to refine the management of vestibular fistula ARM and improve patient outcomes.
Topics: Humans; Female; Retrospective Studies; Anorectal Malformations; Child; Infant; Child, Preschool; Infant, Newborn; Postoperative Complications; Incidence; Treatment Outcome; Poverty; Developing Countries; Recurrence; Rectal Fistula
PubMed: 38854868
DOI: 10.11604/pamj.2024.47.121.42919 -
Plastic and Reconstructive Surgery.... May 2024This study aimed to demonstrate the clinical application of the dorsoproximal interphalangeal island flap as an alternative approach to skin graft or cross-finger flap...
BACKGROUND
This study aimed to demonstrate the clinical application of the dorsoproximal interphalangeal island flap as an alternative approach to skin graft or cross-finger flap to repair lesions at the ventral site at the proximal interphalangeal (PIP) finger joint.
METHODS
Fifteen patients received flaps (11 men and four women, n = 25 flaps). The repair of volar contracture in finger sequelae after burn injuries was the main indication. Five patients underwent two or more flaps during the same surgical session. The mean patient age was 18 years (range, 7-56 years). Most patients presented with palmar finger contractures of the PIP joint. In three patients, six flaps were rotated to the lateral radial and ulnar proximal surfaces of the finger to treat syndactyly.
RESULTS
Most flaps survived and provided satisfactory functional and aesthetic improvement of palmar scar contracture in the PIP region. Postoperative donor site follow-up was normal. The color and pliability of the skin are similar to those of the surrounding area. The follow-up period ranged from 6 months to 12 years.
CONCLUSIONS
Dorsoproximal interphalangeal island flaps are an option for repairing lesions that lack soft tissue and range in size from 10 × 15 to 12 × 18 mm at the volar site and around the PIP joint. The arch of rotation of this flap allows for lateral, ulnar, and radial rotations around the joint. The indication of six flaps in three patients to repair a proximal lack of tissue caused by syndactyly demonstrated its potential use in this anomaly.
PubMed: 38798926
DOI: 10.1097/GOX.0000000000005805 -
International Wound Journal May 2024Preservation and restoration of hand function after burn injuries are challenging yet imperative. This study aimed to assess the curative effect of a composite skin... (Comparative Study)
Comparative Study
Preservation and restoration of hand function after burn injuries are challenging yet imperative. This study aimed to assess the curative effect of a composite skin graft over an acellular dermal matrix (ADM) and a thick split-thickness skin graft (STSG) for treating deep burns on the hand. Patients who met the inclusion criteria at the First Affiliated Hospital of Wenzhou Medical University between September 2011 and January 2020 were retrospectively identified from the operative register. We investigated patient characteristics, time from operation to the start of active motion exercise, take rates of skin graft 7 days post-surgery, donor site recovery, complications and days to complete healing. Patients were followed up for 12 months to evaluate scar quality using the Vancouver Scar Scale (VSS) and hand function through total active motion (TAM) and the Jebsen-Taylor Hand Function Test (JTHFT). A total of 38 patients (52 hands) who received thin STSG on top of the ADM or thick STSG were included. The location of the donor sites was significantly different between Group A (thick STSG) and Group B (thin STSG + ADM) (p = 0.03). There were no statistical differences in age, gender, underlying disease, cause of burn, burn area, dominant hand, patients with two hands operated on and time from burn to surgery between the two groups (p > 0.05). The time from operation to the start of active motion exercise, take rates of skin graft 7 days post-surgery and days to complete healing were not significantly different between Group A and Group B (p > 0.05). The rate of donor sites requiring skin grafting was lower in Group B than in Group A (22.2% vs. 100%, p < 0.001). There were no statistically significant differences in complications between the groups (p = 0.12). Moreover, 12 months postoperatively, the pliability subscore in the VSS was significantly lower in Group A than in Group B (p = 0.01). However, there were no statistically significant differences in vascularity (p = 0.42), pigmentation (p = 0.31) and height subscores (p = 0.13). The TAM and JTHFT results revealed no statistically significant differences between the two groups (p = 0.22 and 0.06, respectively). The ADM combined with thin STSG is a valuable approach for treating deep and extensive hand burns with low donor site morbidity. It has a good appearance and function in patients with hand burns, especially in patients with limited donor sites.
Topics: Humans; Burns; Male; Female; Skin Transplantation; Adult; Retrospective Studies; Middle Aged; Acellular Dermis; Hand Injuries; Young Adult; Wound Healing; Cicatrix; Treatment Outcome
PubMed: 38783559
DOI: 10.1111/iwj.14934 -
World Journal of Urology May 2024To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout...
PURPOSE
To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model.
MATERIAL AND METHODS
We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively).
RESULTS
Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances.
CONCLUSION
Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.
Topics: Ureteroscopy; Ureteroscopes; Humans; Equipment Design; Lighting; Pliability; Kidney Calices
PubMed: 38704777
DOI: 10.1007/s00345-024-04988-1 -
BMC Surgery Apr 2024To investigate the application and effectiveness of tension-reducing suture in the repair of hypertrophic scars.
PURPOSE
To investigate the application and effectiveness of tension-reducing suture in the repair of hypertrophic scars.
METHODS
A retrospective analysis of clinical data was conducted on 82 patients with hypertrophic scars treated at the Department of Burns and Plastic Surgery of Nanjing Drum Tower Hospital from September 2021 to December 2022. Patients were operated with combination of heart-shaped tension-reducing suturing technique and looped, broad, and deep buried (LBD) suturing technique or conventional suture method. Outcomes of surgical treatment were assessed before and 6 months after surgery using the Patient and Observer Scar Assessment Scale (POSAS) and the Vancouver Scar Scale (VSS).
RESULTS
Improvements were achieved on scar quality compared to that preoperatively, with a reduction in scar width (1.7 ± 0.6 cm vs. 0.7 ± 0.2 cm, P < 0.001). Assessment using the POSAS and VSS scales showed significant improvements in each single parameter and total score compared to preoperative values (P < 0.05). The Combination method group achieved better score in total score of VSS scale, in color, stiffness, thickness and overall opinion of PSAS scale, and in vascularity, thickness, pliability and overall opinion of OSAS scale.
CONCLUSION
The amalgamation of the heart-shaped tension-reducing suturing technique and the LBD suturing technique has shown promising outcomes, garnering notably high levels of patient satisfaction in the context of hypertrophic scar repair. Patients have exhibited favorable postoperative recoveries, underscoring the clinical merit and the prospective broader applicability of this approach in the realm of hypertrophic scar management.
Topics: Humans; Cicatrix, Hypertrophic; Suture Techniques; Retrospective Studies; Male; Female; Adult; Middle Aged; Treatment Outcome; Young Adult; Sutures; Adolescent
PubMed: 38654240
DOI: 10.1186/s12893-024-02390-7 -
Clinical, Cosmetic and Investigational... 2024Early intervention of surgical scars with a pulsed dye laser is known to effectively prevent pathologic scars. Despite multiple reports on the effectiveness of the...
PURPOSE
Early intervention of surgical scars with a pulsed dye laser is known to effectively prevent pathologic scars. Despite multiple reports on the effectiveness of the treatment, very few studies have demonstrated its appropriate initiation timing. In this study, our objective was to determine the optimal timing for initiating laser treatment following thyroidectomy.
METHODS
This study retrospectively analyzed 91 patients undergoing pulsed dye laser treatment post-thyroidectomy, grouping them by treatment initiation timing. The patients underwent treatment at intervals of 3-4 weeks with at least five sessions. Those with a high pliability score were injected with intralesional corticosteroids. The Antera 3D skin imaging analyzer was used to assess biophysical parameters.
RESULTS
The total Vancouver Scar Scale score significantly reduced after treatment in all groups. The Vancouver Scar Scale score reduction rate was significantly higher after treatment in the group for which the treatment was initiated within 3 weeks of surgery. The pigmentation and erythema score analyzed by Antera 3D was also lower in this group.
CONCLUSION
Early intervention using a pulsed dye laser within 3 weeks of thyroidectomy can substantially inhibit pathological scar development, providing physicians with a guide for optimal treatment commencement.
PubMed: 38644991
DOI: 10.2147/CCID.S444885 -
Child's Nervous System : ChNS :... Jul 2024Endoscopic third ventriculostomy (ETV) is a well-established surgical technique for treating hydrocephalus. Many providers have transitioned to utilizing the specialized...
Endoscopic third ventriculostomy (ETV) is a well-established surgical technique for treating hydrocephalus. Many providers have transitioned to utilizing the specialized Neuroballoon for the stoma dilation in ETV; however, these devices are intermittently unavailable during supply chain shortages. We present the experience of employing cardiac angioplasty and neurovascular balloons as substitutes for the Neuroballoon in 3 patients. The scepter balloon (Microvention), priced at $1800 compared to the standard $300 Neuroballoon (Integra), proved effective, but its pliability presented technical challenges. The substantial cost differential compared to a Neuroballoon ($300) raises economic considerations. The Cardiac TREK balloon (Abbott) was similarly effective, while also being easier to manage endoscopically and cheaper at $158. These experiences support the viability of non-neuroendoscopic specialized balloons as alternatives for ETV dilation of the floor of tuber cinereum.
Topics: Humans; Ventriculostomy; Hydrocephalus; Third Ventricle; Male; Female; Neuroendoscopy; Infant
PubMed: 38639802
DOI: 10.1007/s00381-024-06361-4 -
International Journal of Surgery... Mar 2024This study aimed to investigate the effectiveness of a novel wound protector in enhancing the cosmetic outcomes of thyroidectomy.
PURPOSE
This study aimed to investigate the effectiveness of a novel wound protector in enhancing the cosmetic outcomes of thyroidectomy.
MATERIAL AND METHODS
This multicenter, double-blinded randomized controlled trial enrolled 129 patients undergoing open thyroidectomy. The patients were divided into a wound protector group and a control group. Subjective patient assessments were conducted, measuring wound satisfaction, pain, and itchiness. Additionally, blinded observers evaluated scars using the Vancouver Scar Scale.
RESULTS
The Vancouver Scar Scale revealed significant advantages for the wound protector group, demonstrating improvements in pigmentation (P=0.002), vascularity (P=0.014), pliability (P=0.001), and height (P=0.001).
CONCLUSION
The thyroid wound protector offers a potential to improve post-operative cosmetic outcomes. Further research is warranted to explore patient experiences and optimize the application of this innovative wound protector across diverse surgical contexts.
PubMed: 38498353
DOI: 10.1097/JS9.0000000000001288