Journal of Cardiology May 2024Risk stratification for patients with non-ischemic cardiomyopathy (NICM) remains challenging as previous studies predicting life-threatening ventricular arrhythmia...
The significance of non-sustained ventricular tachycardia on life-threatening ventricular arrhythmia events in patients with non-ischemic cardiomyopathy in the contemporary era: A systematic review and meta-analysis.
BACKGROUND
Risk stratification for patients with non-ischemic cardiomyopathy (NICM) remains challenging as previous studies predicting life-threatening ventricular arrhythmia (LTVA) events were conducted before the establishment of the current standard treatment. We investigated the prognostic value of non-sustained ventricular tachycardia (NSVT) in NICM patients among recent studies.
METHODS
MEDLINE, Embase were searched from January 2000 to October 2023. The risk of NSVT on LTVA and mortality was assessed using a random-effects model for patients with NICM. A meta-regression analysis was employed to identify sources of heterogeneity. The systematic review and meta-analysis were carried out according to the PRISMA guidelines.
RESULTS
A total of 18 studies were identified, including 5238 pooled participants. Meta-analysis demonstrated that the presence of NSVT was considered a significant prognostic indicator for LTVA events [hazard ratio (HR): 2.90; 95 % CI; 2.31-3.64] with low heterogeneity (I: 19 %) and for mortality (HR; 2.28; 95%CI; 1.26-4.13) with high heterogeneity (I: 69 %). The prognostic value of NSVT for LTVA was not affected by either ejection fraction or medications at baseline.
CONCLUSION
NSVT remained an important predictor of LTVA events even in patients receiving healthcare in contemporary eras. Detection of NSVT helps us to identify the high-risk patients with NICM.
PubMed: 38754764
DOI: 10.1016/j.jjcc.2024.05.004 -
ESC Heart Failure May 2024Implantable cardioverter defibrillators (ICDs) reliably prevent death due to life-threatening arrhythmias; this may become less relevant in people with more severe heart... (Review)
Review
Implantable cardioverter defibrillators (ICDs) reliably prevent death due to life-threatening arrhythmias; this may become less relevant in people with more severe heart failure who are reaching the end of life (EOL). This review aimed to explore the ICD deactivation process and identify ethical issues, especially around the initiation of relevant discussions among professionals and patients. Available literature was reviewed using four electronic databases to identify issues that may deter healthcare professionals from having important deactivation discussions and to address considerations for ICD management prior to the EOL. The search resulted in the retainment of 12 studies. Three themes emerged from the data: barriers and facilitators, ethical considerations in clinical practice, and nurse's role. Lack of knowledge, which has been associated with cultural differences, has been found among the barriers, and interdisciplinary education and open communication appeared as facilitators. As clinicians' ethical considerations and fears emerged from the literature, nurses' special role has not been sufficiently supported. Complex care requires facilitation by multidisciplinary teams and education around the device's function regarding EOL issues. Establishing expert consensus statements on advance care planning might help define the distinct roles of each healthcare practitioner involved. Further research is needed in addressing the identified gaps.
PubMed: 38741255
DOI: 10.1002/ehf2.14831 -
Neurosurgical Review May 2024Cerebral aneurysms in complex anatomical locations and intraoperative rupture can be challenging. Many methods to reduce blood flow can facilitate its exclusion from the... (Meta-Analysis)
Meta-Analysis
BACKGROUND AND OBJECTIVES
Cerebral aneurysms in complex anatomical locations and intraoperative rupture can be challenging. Many methods to reduce blood flow can facilitate its exclusion from the circulation. This study evaluated the safety and efficacy of using adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping.
METHODS
Databases (PubMed, Embase, and Web of Science) were systematically searched for studies documenting the use of adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping and were included in this single-arm meta-analysis. The primary outcome was 30-day mortality. Secondary outcomes included neurological outcomes by mRs and GOS, and cardiac outcomes. We evaluated the risk of bias using ROBIN-I, a tool developed by the Cochrane Collaboration. OpenMetaAnalyst version 2.0 was used for statistical analysis and I2 measured data heterogeneity. Heterogeneity was defined as an I > 50%.
RESULTS
Our systematic search yielded 10,100 results. After the removal of duplicates and exclusion by title and abstract, 64 studies were considered for full review, of which 29 were included. The overall risk of bias was moderate. The pooled proportions of the adenosine analysis for the different outcomes were: For the primary outcome: 11,9%; for perioperative arrhythmia: 0,19%; for postoperative arrhythmia: 0,56%; for myocardial infarction incidence: 0,01%; for follow-up good recovery (mRs 0-2): 88%; and for neurological deficit:14.1%. In the rapid ventricular pacing analysis, incidences were as follows: peri operative arrhythmia: 0,64%; postoperative arrhythmia: 0,3%; myocardial infarction: 0%. In the hypothermia analysis, the pooled proportion of 30-day mortality was 11,6%. The incidence of post-op neurological deficits was 35,4% and good recovery under neurological analysis by GOS was present in 69.2%.
CONCLUSION
The use of the three methods is safe and the related complications were very low. Further studies are necessary, especially with comparative analysis, for extended knowledge.
Topics: Humans; Intracranial Aneurysm; Adenosine; Hypothermia, Induced; Treatment Outcome; Neurosurgical Procedures; Cardiac Pacing, Artificial
PubMed: 38730072
DOI: 10.1007/s10143-024-02450-9 -
Healthcare (Basel, Switzerland) Apr 2024Smartwatches represent one of the most widely adopted technological innovations among wearable devices. Their evolution has equipped them with an increasing array of... (Review)
Review
Smartwatches represent one of the most widely adopted technological innovations among wearable devices. Their evolution has equipped them with an increasing array of features, including the capability to record an electrocardiogram. This functionality allows users to detect potential arrhythmias, enabling prompt intervention or monitoring of existing arrhythmias, such as atrial fibrillation. In our research, we aimed to compile case reports, case series, and cohort studies from the Web of Science, PubMed, Scopus, and Embase databases published until 1 August 2023. The search employed keywords such as "Smart Watch", "Apple Watch", "Samsung Gear", "Samsung Galaxy Watch", "Google Pixel Watch", "Fitbit", "Huawei Watch", "Withings", "Garmin", "Atrial Fibrillation", "Supraventricular Tachycardia", "Cardiac Arrhythmia", "Ventricular Tachycardia", "Atrioventricular Nodal Reentrant Tachycardia", "Atrioventricular Reentrant Tachycardia", "Heart Block", "Atrial Flutter", "Ectopic Atrial Tachycardia", and "Bradyarrhythmia." We obtained a total of 758 results, from which we selected 57 articles, including 33 case reports and case series, as well as 24 cohort studies. Most of the scientific works focused on atrial fibrillation, which is often detected using Apple Watches. Nevertheless, we also included articles investigating arrhythmias with the potential for circulatory collapse without immediate intervention. This systematic literature review provides a comprehensive overview of the current state of research on arrhythmia detection using smartwatches. Through further research, it may be possible to develop a care protocol that integrates arrhythmias recorded by smartwatches, allowing for timely access to appropriate medical care for patients. Additionally, continuous monitoring of existing arrhythmias using smartwatches could facilitate the assessment of the effectiveness of prescribed therapies.
PubMed: 38727449
DOI: 10.3390/healthcare12090892 -
British Journal of Anaesthesia Jul 2024
Meta-Analysis
Topics: Humans; Thoracic Surgical Procedures; Morpholines; Urea; Cardiac Surgical Procedures; Anti-Arrhythmia Agents; Postoperative Complications
PubMed: 38724326
DOI: 10.1016/j.bja.2024.03.036 -
Current Problems in Cardiology Jul 2024Metabolic-dysfunction-associated Steatotic liver disease (MASLD) is a high-risk condition for both liver fibrosis and cardiovascular disease (CVD). Therefore,... (Meta-Analysis)
Meta-Analysis
A review regarding the article 'Electrocardiographic abnormalities in patients with metabolic dysfunction-associated Steatotic liver disease: A systematic review and meta-analysis.'.
Metabolic-dysfunction-associated Steatotic liver disease (MASLD) is a high-risk condition for both liver fibrosis and cardiovascular disease (CVD). Therefore, therapeutic strategies to prevent both liver fibrosis and atherosclerotic CVD are required for the treatment of MASLD. Metabolic dysfunction-associated steatohepatitis (MASH) is the more severe form of MASLD, is defined histologically by the presence of lobular inflammation and hepatocyte ballooning and is associated with a greater risk of fibrosis progression. While CVD is the leading cause of mortality in patients with MASLD, those with more severe liver fibrosis are at increased risk of liver-related mortality, with the risk increasing exponentially with fibrosis stage. MASH has been found in 63% of patients with MASLD undergoing liver biopsy in an Asian multi-center cohort. Multiple complex pathways are involved in the association between MASLD and CVD. The visceral accumulation of fat around the liver and other organs, including the pericardium, leads to the release of fat-derived metabolites with the activation of several inflammatory pathways Cardiac rhythm abnormalities are prevalent in MASLD, such as prolongation of the QT interval, ventricular arrhythmias, and atrial fibrillation. Therapeutic interventions that improve cardiometabolic risk factors may be beneficial for an improvement in MASLD. The effects of such therapeutic interventions on lipid, lipoprotein and apoprotein accumulation in the liver and on hepatic steatosis and fibrosis still remain unelucidated. Which lipid factor is crucial for developing MASLD also remains largely unknown.
Topics: Humans; Electrocardiography; Fatty Liver; Arrhythmias, Cardiac; Cardiovascular Diseases
PubMed: 38718937
DOI: 10.1016/j.cpcardiol.2024.102626 -
Forensic Science International Jun 2024Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions.
METHODS
A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I statistic was used to assess heterogeneity.
RESULTS
A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases.
CONCLUSIONS
Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.
Topics: Humans; Arrhythmias, Cardiac; Defibrillators, Implantable; Equipment Failure; Pacemaker, Artificial; Cause of Death; Guidelines as Topic; Autopsy
PubMed: 38714107
DOI: 10.1016/j.forsciint.2024.112001 -
Thrombosis Research Jun 2024This systematic review assesses the likelihood of developing dementia and cognitive impairment in patients with atrial fibrillation (AF) receiving non-vitamin K... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
This systematic review assesses the likelihood of developing dementia and cognitive impairment in patients with atrial fibrillation (AF) receiving non-vitamin K antagonist oral anticoagulants (NOACs) as opposed to vitamin K antagonists (VKAs).
METHODS
We performed a systematic review with meta-analysis and trial sequential analysis (TSA), which encompassed both randomized controlled trials (RCTs) and observational studies. The objective was to assess the impact of NOACs and VKAs on the incidence of dementia in individuals diagnosed with AF.
RESULTS
Out of 1914 studies that were screened, 31 studies were included in the final analysis, which consisted of nine RCTs or their subsequent post-hoc analyses, in addition to 22 observational studies. The meta-analysis shows that NOACs were associated with a decreased probability of developing dementia of any cause [Rate Ratio (RR): 0.88; 95 % confidence interval (95 % CI): 0.82-0.94], especially in patients below the age of 75 (RR: 0.78; 95 % CI: 0.73-0.84). Consistent patterns were observed across all forms of dementia and cognitive function decline. The overall evidence indicates notable variability in the outcome with a moderate-to-low degree of certainty. The TSA suggests that the total sample size of the included trials (155,647 patients) was significantly smaller than the required information size of 784,692 patients to discern the true effect of NOAC versus VKA in terms of reducing dementia risk.
CONCLUSION
NOACs may reduce the likelihood of developing dementia in patients with AF, particularly in those under the age of 75. This review highlights the urgent necessity for thorough research to determine the efficacy of NOACs in safeguarding cognitive health.
Topics: Humans; Atrial Fibrillation; Anticoagulants; Administration, Oral; Dementia; Cognitive Dysfunction; Randomized Controlled Trials as Topic; Cognition Disorders; Aged
PubMed: 38704897
DOI: 10.1016/j.thromres.2024.04.032 -
Journal of Cardiothoracic Surgery May 2024To evaluate the clinical efficacy and safety of intraoperative intravenous amiodarone for arrhythmia prevention in on-pump coronary artery bypass grafting (CABG)... (Meta-Analysis)
Meta-Analysis Review
The efficacy and safety of intraoperative intravenous amiodarone in patients undergoing on-pump coronary artery bypass grafting surgery: a systemic review and PRISMA-compliant meta-analysis.
BACKGROUND
To evaluate the clinical efficacy and safety of intraoperative intravenous amiodarone for arrhythmia prevention in on-pump coronary artery bypass grafting (CABG) patients.
METHODS
A meta-analysis of randomized controlled trials was conducted. Pubmed, Embase, Cochrane Library, Ovid, China National Knowledge Infrastructure, and the Wan Fang database until July 1th, 2023. The primary outcomes of interest included the incidences of intra- and post-operative atrial fibrillation (POAF), ventricular fibrillation, or any arrhythmia, including atrial fibrillation, ventricular fibrillation, ventricular tachycardia, premature ventricular contraction, and sinus bradycardia. For continuous and dichotomous variables, treatment effects were calculated as the weighted mean difference (WMD)/risk ratio (RR) and 95% confidence interval (CI).
RESULTS
A database search yielded 7 randomized controlled trials including 608 patients, where three studies, including three treatments (amiodarone, lidocaine, and saline), contributed to the clinical outcome of atrial fibrillation, ventricular fibrillation, or any arrhythmia. Meta-analysis demonstrated that amiodarone can significantly reduce the incidence of POAF (RR, 0.39; 95%CI: 0.20, 0.77; P = 0.007, I = 0%) in patients undergoing on-pump CABG; there was no statistically significant influence on intra-operative atrial fibrillation, intra- and post-operative ventricular fibrillation, or any arrhythmia.
CONCLUSIONS
The current study suggests that intraoperative administration of intravenous amiodarone may be safe and effective in preventing POAF in patients undergoing on-pump CABG. More well-designed clinical trials are needed to validate this result.
Topics: Humans; Amiodarone; Coronary Artery Bypass; Anti-Arrhythmia Agents; Arrhythmias, Cardiac; Intraoperative Care; Administration, Intravenous; Postoperative Complications; Treatment Outcome; Randomized Controlled Trials as Topic
PubMed: 38702789
DOI: 10.1186/s13019-024-02732-9 -
Thrombosis Research Jun 2024Recommendations about proper anticoagulation in obese patients, body mass index (BMI) > 30 kg/m2, are not yet clearly defined. Obese patients were included in... (Meta-Analysis)
Meta-Analysis
Obese patients with atrial fibrillation are more efficiently protected from thrombosis under warfarin or xabans compared to non-obese patients; a systematic review and Meta-analysis of six randomized controlled trials.
INTRODUCTION
Recommendations about proper anticoagulation in obese patients, body mass index (BMI) > 30 kg/m2, are not yet clearly defined. Obese patients were included in randomized controlled trials comparing new anticoagulants (NOACs) with warfarin in patients with atrial fibrillation or thromboembolism.
METHODS
We performed a medline search entering proper criteria and finally 6 post-hoc analysis of RCTs, reporting outcome according to BMI, were included in this meta-analysis. Two major outcomes were considered end points in our meta-analysis; thrombosis, including ischemic cerebral events (transient or not) and venous thrombosis (DVD) /pulmonary embolism (PE) and bleeding, including major bleeding and clinically relevant non-major bleeding.
RESULTS
In the NOACs treated group, thrombosis occurred less frequently in obese vs non-obese patients; RR and 95 % CI 0,75 (0,58-0,97), p = 0,03, while low heterogeneity was observed (I 40 %). In the warfarin treated subgroup there was statistically significant difference with less thrombotic events occurring in the obese vs non-obese patients; RR and (95 % CI) 0,80 (0,66-0,98), p = 0,03, and heterogeneity was low (I = 24 %). This protective effect called the obesity paradox is limited to obese patients anticoagulated for non-valvular atrial fibrillation (NVAF); RR (95 % CI) was 0,70 (0,58-0,85) p = 0,03 and I = 24 %. Bleeding events were similar under both NOACs and warfarin in obese vs non-obese analysis.
CONCLUSIONS
Obese patients anticoagulated for NVAF with either standard dose of xabans or INR guided warfarin are more efficiently protected against thrombosis compared to non-obese patients.
Topics: Humans; Atrial Fibrillation; Warfarin; Obesity; Anticoagulants; Randomized Controlled Trials as Topic; Thrombosis; Hemorrhage; Factor Xa Inhibitors
PubMed: 38696925
DOI: 10.1016/j.thromres.2024.04.022