-
Cureus Nov 2023Pulmonary valve replacement (PVR) is a critical aspect of surgical management for patients with tetralogy of Fallot (ToF). Determining an optimal timeframe for... (Review)
Review
Pulmonary valve replacement (PVR) is a critical aspect of surgical management for patients with tetralogy of Fallot (ToF). Determining an optimal timeframe for intervention is imperative, as it directly impacts long-term outcomes and the risk of complications in ToF patients. Ventriculotomy with the transannular patch is currently indicated for right ventricular outflow tract obstruction, but the patch itself can lead to pulmonary regurgitation (PR), dyspnea, and cyanosis, among other complications. This investigation seeks to establish an evidence-based timeline to enhance the overall quality of care for individuals with this congenital heart condition. From 2002 to 2022, 21,935 articles regarding the PVR timing for ToF were examined and filtered. The publications were screened using PRISMA guidelines, and 32 studies were included for analysis and review. Among the studies, PVR was strongly indicated for patients who had developed severe PR, especially in asymptomatic patients and those experiencing fatigue and exercise intolerance. Severe PR was associated with arrhythmias such as right bundle branch block, atrioventricular block, and prolonged QRS intervals, in which male sex and high right ventricular end-diastolic volume (RVEDV) were significant predictors of long preoperative QRS duration. Most physicians found RVEDV necessary for making surgical referrals despite a lack of correlation between PR severity and RVEDV or indexed right ventricular end-systolic volume (RVESVi). However, asymptomatic ToF patients with preoperative RVESVi benefited from PVR. Except for some variations in QRS intervals among studies, arrhythmias tended to persist post-op, yet NYHA functional class and RV size improved significantly following PVR. Older age at PVR was found to be associated with adverse cardiac events, whereas early PVR presented with appropriately short QRS intervals. Cardiac function tended to be significantly worse in patients undergoing late PVR versus early PVR, with timelines ranging from one to three decades following initial ToF repair. Choosing the best timeline for PVR largely depends on the patient's baseline cardiopulmonary presentation, and additional quantitative deformation analysis can help predict an appropriate timeline for ToF patients.
PubMed: 38156158
DOI: 10.7759/cureus.49577 -
Clinical Therapeutics Feb 2024Cardiovascular adverse events (CVAEs) are common adverse effects of first-generation Bruton tyrosine kinase inhibitors (BTKis) and limit their use considerably. This led... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
Cardiovascular adverse events (CVAEs) are common adverse effects of first-generation Bruton tyrosine kinase inhibitors (BTKis) and limit their use considerably. This led to the development of second-generation BTKis-acalabrutinib and zanubrutinib-which are more selective, potent, and presumed to have better safety profiles than the previous group of medications. However, there have been sporadic reports of CVAEs associated with second-generation BTKis in clinical practice. To address this issue, a comprehensive meta-analysis to pool the documented CVAEs was performed, including major hemorrhage, any bleeding, atrioventricular block, atrial fibrillation/flutter, pericardial effusion, pericarditis, heart failure, cardiac arrest, myocardial infarction, hypertension, hypotension, and stroke. This meta-analysis incorporated 8 studies. Among these, 6 were Phase III trials and 2 were Phase II trials. These studies collectively enrolled a total of 2938 patients.
METHODS
Multiple databases, including PubMed, MEDLINE, Cochrane Library, Scopus, and EMBASE, were systematically searched for relevant clinical trials from inception through January 14, 2023. The effect measure used was odds ratio (OR) and 95% CI.
FINDINGS
Of a total of 1774 studies identified during the initial database search, 8 were included in the meta-analysis. The incidence of overall and cardiovascular mortality was comparable between the 2 groups. There were no significant differences observed for cardiovascular mortality (OR = 0.36; 95% CI, 0.08-1.65; n = 2588; I = 45%; P = 0.19). Similar results were found for all-cause mortality (OR = 0.85; 95% CI, 0.67-1.07), any bleeding (OR = 1.90; 95% CI, 0.88-4.09), major bleeding (OR = 1.07; 95% CI, 0.65-1.76), atrioventricular block (OR = 0.74; 95% CI, 0.15-3.68), atrial fibrillation/flutter (OR = 0.74; 95% CI, 0.37-1.50), and other CVAEs associated with second-generation BTKis.
IMPLICATIONS
Based on the available evidence, there is no indication of worse cardiovascular outcomes or superiority of second-generation BTKis compared with standard treatments in terms of safety profile. However, additional large-scale controlled trials are needed to provide robust support for the superior tolerability of new-generation BTKis.
Topics: Humans; Atrial Fibrillation; Tyrosine Kinase Inhibitors; Atrioventricular Block; Myocardial Infarction; Hypertension
PubMed: 38102000
DOI: 10.1016/j.clinthera.2023.11.014 -
The American Journal of Cardiology Dec 2023Clinical evidence and emerging studies suggest that the clinical heterogeneity observed in hypertrophic cardiomyopathy could be because of gender-based differences. We... (Meta-Analysis)
Meta-Analysis Review
Gender-Based Outcome Discrepancies in Patients Who Underwent Alcohol Septal Ablation or Septal Myectomy for Hypertrophic Obstructive Cardiomyopathy: A Systematic Review and Meta-Analysis.
Clinical evidence and emerging studies suggest that the clinical heterogeneity observed in hypertrophic cardiomyopathy could be because of gender-based differences. We aimed to explore the gender-related differences pertaining to the treatment outcomes after alcohol septal ablation (ASA) and septal myectomy (SM). We searched PUBMED/MEDLINE, EMBASE, and SCOPUS to identify studies that report gender-stratified comparison of outcomes. The primary outcome of interest was short-term (within 30 days) mortality. A total of 15 studies totaling 31,907 patients (47% men and 53% women) were included. Women were found to be significantly older at the time of intervention (ASA: mean difference [MD] 7.55 years; SM: MD 4.41). In the ASA and SM treatment arms, women had a significantly higher risk of short-term all-cause mortality (ASA: risk ratio 0.48, 95% confidence interval 0.32 to 0.71, p = 0.0003; SM: risk ratio 0.63, 95% confidence interval 0.44 to 0.90, p = 0.01), more frequent permanent pacemaker implantation (ASA; p = 0.002, SM: p = 0.05), and longer in-hospital stay (ASA: MD 1.00 days, SM: MD 0.69). Among those who underwent ASA, women had a significantly higher rate of atrioventricular block. In conclusion, regardless of ASA or SM, women consistently presented at an older age and exhibited a higher risk-increased mortality rate, a greater incidence of atrioventricular block, and a higher likelihood of permanent pacemaker requirement-and longer hospital stay among women than men. This strongly emphasizes the need for a gender-specific approach to optimize care and improve treatment outcomes in hypertrophic cardiomyopathy.
Topics: Male; Humans; Female; Ethanol; Atrioventricular Block; Ablation Techniques; Heart Septum; Cardiomyopathy, Hypertrophic; Treatment Outcome
PubMed: 37839170
DOI: 10.1016/j.amjcard.2023.09.033 -
Frontiers in Cardiovascular Medicine 2023Atrioventricular block (AVB) is a serious complication following coronary artery bypass grafting (CABG) surgery, and its high-grade form may necessitate the implantation... (Review)
Review
BACKGROUND AND OBJECTIVES
Atrioventricular block (AVB) is a serious complication following coronary artery bypass grafting (CABG) surgery, and its high-grade form may necessitate the implantation of a permanent pacemaker (PPM). AVB is associated with increased morbidity and mortality rates. This study aims to estimate the incidence of AVB and subsequent PPM implantation after isolated CABG surgery.
MATERIAL AND METHODS
We searched electronic databases of PubMed, Embase, and Scopus from inception to 18 November 2022. Clinical trials and observational studies reporting the incidence of post-CABG AVB or subsequent PPM implantation in adult patients were included. The total incidence for all included outcomes was calculated using the inverse variance method, and the statistic was reported to evaluate the heterogeneity of studies.
RESULTS
A total of 28 studies met the inclusion criteria. Four studies [3 cohorts, 1 randomized controlled trial (RCT)] reported AVB without specifying its type; one (cohort) reported different degrees of AVB, 20 (12 cohorts, 8 RCTs) reported complete heart block (CHB) (or AVB requiring temporary pacing), and nine (8 cohorts, 1 RCT) reported the number of PPM inserted due to AVB. The pooled incidence of AVB, CHB (or AVB requiring temporary pacing), and PPM due to AVB was 1.16%, 1.73%, and 0.58%, respectively. Meta-regression analysis revealed that age, gender, diabetes, hypertension, hyperlipidemia, or smoking were not significantly associated with AVB, CHB, or PPM implantation.
CONCLUSION
This study highlights the incidence of AVB and the need for PPM implantation following CABG surgery. The findings emphasize the importance of postoperative monitoring and surveillance to improve patient outcomes.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022377181, identifier PROSPERO CRD42022377181.
PubMed: 37593149
DOI: 10.3389/fcvm.2023.1225833 -
The American Journal of Cardiology Sep 2023The outcomes of leadless pacemaker (LP) implantation after transvenous lead removal (TLR) of infected cardiac implantable electronic devices (CIEDs) are not...
The outcomes of leadless pacemaker (LP) implantation after transvenous lead removal (TLR) of infected cardiac implantable electronic devices (CIEDs) are not well-established. This study sought to describe the outcomes of LP implantation after TLR of infected CIED. We conducted a literature search using PubMed and Embase for a combination of terms including LP implantation, transvenous lead extraction, TLR, transvenous lead explant, infected CIED, infected pacemaker, and infected implantable cardioverter defibrillator. The inclusion criterion was LP implantation after TLR of infected CIED. The exclusion criterion was TLR for noninfectious reasons. Study end points included procedural complications and LP infection during follow-up. Of 132 publications reviewed, 13 studies with a total of 253 patients (74 ± 14 years of age, 174 [69%] males) were included. The most common indication of the initial device implantations was a high-degree atrioventricular block (n = 100 of 253, 39.5%). Of the 253 patients included, 105 patients (41.5%) underwent concomitant LP implantation during the TLR procedure, and 36 patients (14.2%) had temporary transvenous pacing as a bridge from TLR to LP implantation. Of the 148 patients with data on the type of CIED infection, 56.8% had systemic CIED infection and 43.2% had isolated pocket infection. Staphylococcus aureus was the most common causative organism in 33% of the reported patients. The LP was implanted an average of 5.4 ± 10.7 days after TLR of infected CIED. During the LP implantation, 1 patient (0.4%) had unsuccessful implantation because of an intraprocedural complication requiring sternotomy. After LP implantation, 2 patients (0.8%) developed groin hematoma, 2 patients (0.8%) developed femoral arteriovenous fistula, and 1 patient (0.4%) developed pericardial effusion requiring pericardiocentesis. During a mean follow-up of 11.3 ± 10.6 months, 3 patients (1.2%) developed pacemaker syndrome, 1 patient (0.4%) developed acute on chronic heart failure exacerbation, and only 1 patient (0.4%) developed LP-related infection requiring LP retrieval. This study suggests that LP implant is feasible and safe after removal of infected CIED with cumulative adverse events at 4% and a reinfection rate of 0.4%. Large prospective studies are needed to better evaluate the best timing of LP implantation after TLR of an infected CIED.
Topics: Male; Humans; Female; Treatment Outcome; Prosthesis-Related Infections; Device Removal; Pacemaker, Artificial; Defibrillators, Implantable; Retrospective Studies
PubMed: 37542954
DOI: 10.1016/j.amjcard.2023.07.071 -
Pediatric Cardiology Dec 2023Pacing indications in children are clearly defined, but whether an epicardial (EPI) or an endocardial (ENDO) pacemaker performs better remains to be elucidated. This... (Meta-Analysis)
Meta-Analysis Review
Pacing indications in children are clearly defined, but whether an epicardial (EPI) or an endocardial (ENDO) pacemaker performs better remains to be elucidated. This systematic review and meta-analysis aimed to directly compare the incidence of pacemaker (PM) lead-related complications, mortality, hemothorax and venous occlusion between EPI and ENDO in children with atrioventricular block (AVB) or sinus node dysfunction (SND). Literature search was conducted in MEDLINE (via PubMed), Scopus by ELSEVIER, Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, and OpenGrey databases until June 25, 2022. Random-effects meta-analyses were performed to assess the pacing method's effect on lead failure, threshold rise, post-implantation infection and battery depletion and secondarily on all-cause mortality, hemothorax and venous occlusion. Several sensitivity analyses were also performed. Of 22 studies initially retrieved, 18 were deemed eligible for systematic review and 15 for meta-analysis. Of 1348 pediatric patients that underwent EPI or ENDO implantation, 542 (40.2%) had a diagnosis of congenital heart disease (CHD). EPI was significantly associated with higher possibility of PM-lead failure [pooled odds ratio (pOR) 3.00, 95% confidence interval (CI) 2.05-4.39; I = 0%]; while possibility for threshold rise, post-implantation infection and battery depletion did not differ between the PM types. Regarding the secondary outcome, the mortality rates between EPI and ENDO did not differ. In sensitivity analyses the results were consistent results between the two PM types. The findings suggest that EPI may be associated with increased PM-lead failure compared to ENDO while threshold rise, infection, battery depletion and mortality rates did not differ.
Topics: Child; Humans; Atrioventricular Block; Sick Sinus Syndrome; Cardiac Pacing, Artificial; Hemothorax; Treatment Outcome; Pacemaker, Artificial; Postoperative Complications; Vascular Diseases
PubMed: 37480376
DOI: 10.1007/s00246-023-03213-x -
Current Problems in Cardiology Dec 2023His-Purkinje conduction system pacing (HPCSP) via His bundle pacing (HBP) and Left Bundle Branch Pacing (LBBP) offer a physiological approach to pacing by restoring... (Meta-Analysis)
Meta-Analysis Review
Left Bundle Branch Pacing: A Paradigm Shift in Physiological Pacing for Patients With Atrioventricular Block and Preserved Left Ventricular Systolic Function, A Systematic Review and Meta-analysis.
His-Purkinje conduction system pacing (HPCSP) via His bundle pacing (HBP) and Left Bundle Branch Pacing (LBBP) offer a physiological approach to pacing by restoring normal ventricular activation. This meta-analysis compares the feasibility, outcomes, and success rates of HBP and LBBP in patients with atrioventricular block (AVB) and preserved left ventricular function. A systematic search identified studies comparing LBBP with HBP in AVB patients with preserved systolic function. Primary outcomes included QRS duration, success rates, pacing threshold, and improvement in R-wave amplitudes. Secondary outcomes were procedure time and fluoroscopy time. Random-effects models calculated odds ratios (OR) and mean differences (MD) with 95% confidence intervals (CI). Methodological quality was assessed using the Newcastle-Ottawa scale. Among 382 screened articles, seven observational studies involving 1035 patients were analyzed. The mean age was 69.9 years, the mean LVEF was 59.3%, and the average follow-up duration was 8.7 months. LBBP showed higher R-wave amplitudes (MD 7.88, 95% CI 7.26 to 8.50, P < 0.0001) and lower pacing thresholds (MD -0.64, 95% CI -0.81 to -0.47, P < 0.0001) compared to HBP. LBBP had shorter procedure time (MD -17.81, 95% CI -30.44 to -5.18, P = 0.006) and reduced fluoroscopy time (MD -5.39, 95% CI -8.81 to -1.97, P = 0.002). No significant differences were observed in QRS duration or success rates. LBBP offers advantages over HBP, including improved electrical activation, lower pacing thresholds, and shorter procedure and fluoroscopy times. Success rates and QRS duration reductions were comparable between LBBP and HBP. These findings support LBBP as a feasible and effective alternative to HBP in AVB patients with preserved systolic function.
Topics: Humans; Aged; Atrioventricular Block; Bundle of His; Ventricular Function, Left; Cardiac Pacing, Artificial; Electrocardiography; Treatment Outcome
PubMed: 37473943
DOI: 10.1016/j.cpcardiol.2023.101983 -
Catheterization and Cardiovascular... Jul 2023Left circumflex coronary artery (LCx) injury related to mitral valve surgery is a rare complication. The best treatment option is not defined, and percutaneous coronary... (Review)
Review
Left circumflex coronary artery (LCx) injury related to mitral valve surgery is a rare complication. The best treatment option is not defined, and percutaneous coronary intervention (PCI) may represent an effective treatment to avoid prolonged myocardial ischemia. To evaluate feasibility and efficacy of PCI treatment, all records of LCx injury related to mitral valve surgery and treated with PCI were included after a systematic PubMed searching. Moreover, we retrospectively analyzed our single-center PCI database and patients fulfilling the inclusion criteria were included. Patients undergoing transcatheter mitral valve intervention, non-mitral valve surgery, conservatively or surgically treated after LCx injury were excluded. Data about patient characteristics, procedural details, PCI success, and in-hospital mortality were collected. Fifty-six patients were included, 58.9% were male (n = 33) and the median age was 60.5 years (IQR = 21.75). The majority had left dominant or codominant coronary system (62.2%, n = 28 and 15.6%, n = 7, respectively). Clinical manifestations ranged from hemodynamic stability (21.1%, n = 8) to hemodynamic instability (42.1%, n = 16) and cardiac arrest (18.4%, n = 7). On ECG, 23.5% of patients (n = 12) presented ST-segment depression, 58.8% (n = 30) ST-segment elevation, 7.8% (n = 4) atrioventricular block, and 29.4% (n = 15) ventricular arrhythmias. Left ventricle dysfunction was present in 52.3% (n = 22) of patients and wall motion abnormalities in 71.4% (n = 30). PCI success rate was 82.1% (n = 46) and in-hospital mortality 4.5% (n = 2). LCx injury related to mitral surgery is a rare complication characterized by an increased risk of mortality. PCI seems a feasible treatment option, still burdened by suboptimal results, probably related to the technical challenges posed by the surgical failure.
Topics: Humans; Male; Middle Aged; Female; Coronary Vessels; Percutaneous Coronary Intervention; Treatment Outcome; Retrospective Studies; Mitral Valve
PubMed: 37210617
DOI: 10.1002/ccd.30693 -
Diagnostics (Basel, Switzerland) Apr 2023Neonatal lupus (NL) is a clinical syndrome that develops in the fetus as a result of maternal autoimmune antibodies. Congenital complete heart block (CHB) is the most... (Review)
Review
Endocardial Fibroelastosis as an Independent Predictor of Atrioventricular Valve Rupture in Maternal Autoimmune Antibody Exposed Fetus: A Systematic Review with Clinicopathologic Analysis.
BACKGROUND
Neonatal lupus (NL) is a clinical syndrome that develops in the fetus as a result of maternal autoimmune antibodies. Congenital complete heart block (CHB) is the most common manifestation, while extranodal cardiac manifestations of NL, such as endocardial fibroelastosis (EFE) and myocarditis, are rare but more serious. Less is known about this atrioventricular valve rupture due to valvulitis as a consequence of maternal autoantibodies. We have described a case of cardiac neonatal lupus with an antenatally detected CHB patient who developed mitral and tricuspid valve chordal rupture at 45 days of age. We compared the cardiac histopathology and the fetal cardiac echocardiographic findings of this case with another fetus that was aborted after being antenatally diagnosed with CHB but without valvar rupture. A narrative analysis after a systematic review of the literature regarding atrioventricular valve apparatus rupture due to autoimmune etiology along with maternal characteristics, presentation, treatment, and outcome have been discussed in this article.
OBJECTIVES
To describe published data on atrioventricular valve rupture in neonatal lupus, including clinical presentation, diagnostic evaluation, management, and outcomes.
METHODS
We conducted a PRISMA-compliant descriptive systematic examination of case reports that included accounts of lupus during pregnancy or in the newborn period that resulted in an atrioventricular valve rupture. We gathered information on the patient's demographics, the details of the valve rupture and other comorbidities, the maternal therapy, the clinical course, and the results. We also used a standardized method to evaluate the cases' quality. A total of 12 cases were investigated, with 11 cases drawn from 10 case reports or case series and 1 from our own experience.
RESULTS
Tricuspid valve rupture (50%) is more common than mitral valve rupture (17%). Unlike mitral valve rupture, which occurs postnatally, the timing of tricuspid valve rupture is perinatal. A total of 33% of the patients had concomitant complete heart block, while 75% of the patients had endocardial fibroelastosis on an antenatal ultrasound. Antenatal changes pertaining to endocardial fibroelastosis can be seen as early as 19 weeks of gestation. Patients with both valve ruptures generally have a poor prognosis, especially if they occur at close intervals.
CONCLUSION
Atrioventricular valve rupture in neonatal lupus is rare. A majority of patients with valve rupture had antenatally detected endocardial fibroelastosis in the valvar apparatus. Appropriate and expedited surgical repair of ruptured atrioventricular valves is feasible and has a low mortality risk. Rupture of both atrioventricular valves occurring at close intervals carries a high mortality risk.
PubMed: 37189582
DOI: 10.3390/diagnostics13081481 -
Anatolian Journal of Cardiology Mar 2023Over the past few years, smartwatches have become increasingly popular in the monitoring of arrhythmias. Although the detection of atrial fibrillation with smartwatches... (Review)
Review
BACKGROUND
Over the past few years, smartwatches have become increasingly popular in the monitoring of arrhythmias. Although the detection of atrial fibrillation with smartwatches has been the subject of various articles, there is no comprehensive research on the detection of arrhythmias other than atrial fibrillation. In this study, we included individual cases from the literature to identify the characteristics of patients with smartwatch-detected arrhythmias other than atrial fibrillation.
METHODS
PubMed, Embase, and SCOPUS were searched for case reports, case series, or cohort studies that reported individual participant-level data, until January 6, 2022. The following search string was used for each databases: ('Smart Watch' OR 'Apple Watch' OR 'Samsung Gear') AND ('Supraventricular Tachycardia' OR 'Cardiac Arrhythmia' OR 'Ventricular Tachycardia' OR 'Atrioventricular Nodal Reentry Tachycardia' OR 'Atrioventricular Reentrant Tachycardia' OR 'Heart Block' OR 'Atrial Flutter' OR 'Ectopic Atrial Tachycardia' OR 'Bradyarrhythmia').
RESULTS
A total of 52 studies from PubMed, 20 studies from Embase, and 200 studies from SCOPUS were identified. After screening, 18 articles were included. A total of 22 patients were obtained from 14 case reports or case series. Four cohort studies evaluating various arrhythmias were included. Arrhythmias, including ventricular tachycardia, atrial fibrillation, atrial flutter, atrioventricular nodal reentry tachycardia, atrioventricular reentrant tachycardia, second- or third-degree atrioventricular block, and sinus bradycardia, were detected with smartwatches.
CONCLUSIONS
Cardiac arrhythmias other than atrial fibrillation are also commonly detected with smartwatches. Smartwatches have an important potential besides traditional methods in the detection of arrhythmias and clinical practice.
Topics: Humans; Atrial Fibrillation; Bradycardia; Atrial Flutter; Tachycardia, Ventricular; Atrioventricular Block; Tachycardia, Atrioventricular Nodal Reentry
PubMed: 36856589
DOI: 10.14744/AnatolJCardiol.2023.2799