Nutrients Apr 2023The Mediterranean diet (MD) is a healthy diet pattern that can prevent chronic age-related diseases, especially age-related eye diseases (AREDs) including cataract,... (Review)
Review
The Mediterranean diet (MD) is a healthy diet pattern that can prevent chronic age-related diseases, especially age-related eye diseases (AREDs) including cataract, glaucoma, age-related macular degeneration (AMD), diabetic retinopathy (DR) and dry eye syndrome (DES). In this study, we systematically reviewed studies in the literature that had reported associations between adherence to the MD and the five above-mentioned AREDs. Randomized controlled trials as well as prospective and retrospective observational studies were included; 1164 studies were identified, of which 1, 2, 9, 2 and 4 studies met our eligibility criteria for cataract, glaucoma, AMD, DR, and DES, respectively. According to these studies, higher MD adherence was associated with reduced risks of incident DR, incident AMD and progression to late AMD, but whether early and neovascular AMD could be alleviated remained to be debated. The results regarding the effects of the MD on DES were mixed, with three studies reporting an associations between MD and decreased severity or incidence of DES, whereas one study reported the opposite. No significant associations were observed between the MD and cataract or glaucoma. Generally, convincing evidence suggested a protective effect of the MD against AMD and DR. However, the evidence for cataract, glaucoma, and DES was less conclusive, and high-quality studies are needed for comprehensive evaluations of the potential benefits of MD on these eye diseases.
Topics: Humans; Angiogenesis Inhibitors; Diet, Mediterranean; Prospective Studies; Retrospective Studies; Vascular Endothelial Growth Factor A; Visual Acuity; Wet Macular Degeneration; Glaucoma; Cataract; Diabetic Retinopathy
PubMed: 37432187
DOI: 10.3390/nu15092043 -
Journal of Glaucoma Oct 2023This systematic review has revealed that variable definitions of glaucoma continue to be used in prevalence studies, despite the introduction of the International...
PRCIS
This systematic review has revealed that variable definitions of glaucoma continue to be used in prevalence studies, despite the introduction of the International Society of Geographic and Epidemiologic Ophthalmology (ISGEO) criteria.
PURPOSE
To systematically review diagnostic criteria and examinations performed in glaucoma prevalence studies over time and determine the quality of reporting. Accurate estimates of glaucoma prevalence are crucial to inform resource allocation. However, diagnosis of glaucoma comprises inherently subjective examinations and the cross-sectional nature of prevalence studies precludes monitoring for progression.
METHODS
A systematic review of PubMed, Embase, Web of Science, and Scopus was performed to examine diagnostic protocols used by glaucoma prevalence studies and evaluate uptake of the ISGEO criteria, introduced in 2002 to standardize glaucoma diagnosis in prevalence studies. Detection bias and compliance with the Strengthening Reporting of Observational Studies in Epidemiology (STROBE) guidelines were evaluated.
RESULTS
Ten thousand five hundred forty-four articles were identified. After deduplication, 5589 articles were screened, yielding 136 articles pertaining to 123 studies. An absence of data in many countries was identified. Ninety-two percent of studies stated diagnostic criteria, and 62% used the ISGEO criteria since their publication. Weaknesses of the ISGEO criteria were identified. Temporal variations in the performance of various examinations were observed, including heterogeneity in angle assessment. Mean STROBE compliance was 82% (range 59-100%); 72 articles had a low risk of detection bias, 4 had a high risk, and 60 had some concerns.
CONCLUSION
Heterogeneous diagnostic definitions persist in glaucoma prevalence studies, despite introduction of the ISGEO criteria. Standardization of criteria remains imperative and the development of new criteria represent a valuable opportunity to achieve this goal. In addition, methods of determining diagnoses are poorly reported, suggesting a need for improvement in study conduct and reporting. Accordingly, we propose the Reporting of quality Of GlaUcoma Epidemiological Studies (ROGUES) Checklist. We have also identified a need for further prevalence studies in regions with limited data and to update Australian angle closure glaucoma prevalence. Design and reporting of future studies can be informed by this review's insights into diagnostic protocols previously used.
Topics: Humans; Cross-Sectional Studies; Intraocular Pressure; Australia; Glaucoma; Glaucoma, Angle-Closure; Prevalence
PubMed: 37406297
DOI: 10.1097/IJG.0000000000002248 -
Ophthalmology Science Dec 2023To provide standardized confidence limits of the transient pattern electroretinogram (tPERG) P50 and N95 and steady state pattern electroretinogram (ssPERG) amplitudes...
TOPIC
To provide standardized confidence limits of the transient pattern electroretinogram (tPERG) P50 and N95 and steady state pattern electroretinogram (ssPERG) amplitudes in normal controls as compared to ocular hypertension (OHT), glaucoma suspect (GS), or early manifest glaucoma (EMG) eyes.
CLINICAL RELEVANCE
The identification of standardized confidence limits in the context of pattern electroretinogram (PERG) might overcome the high intrinsic variability of the measure, and it might lead to a more intuitive understanding of the results as well as to an easier comparison of data from multiple tests, sites, and operators.
METHODS
The study protocol was prospectively registered on the International Prospective Register of Systematic Reviews (ID: CRD42022370032). A literature search was conducted on PubMed, Web of Science, and Scopus. Studies comparing PERG raw data in normal control eyes as compared to OHT, GS, or EMG were included. The risk of bias was assessed using the National Institute for Health and Clinical Excellence quality assessment tool. The main outcome was the P50, N95, and ssPERG amplitude difference between the control and the study groups' eyes. The standardized mean difference was calculated as a measure of the effect size for the primary outcome. A subanalysis was conducted based on the type of electrodes adopted for the PERG measurements (invasive vs. noninvasive).
RESULTS
Of the 4580 eligible papers, only 23 were included (1754 eyes). Statistically significant amplitude differences were found in the P50, N95, and ssPERG amplitudes between normal controls and OHT, GS, and EMG eyes. The highest standardized mean difference values were observed in the ssPERG amplitude in all 3 sets of comparison. The subanalysis did not reveal any statistically significant differences between invasive and noninvasive recording strategies.
CONCLUSIONS
The use of standardized values as the main outcome measures in the context of the PERG data analysis is a valid approach, normalizing several confounding factors which have affected the clinical utility of PERG both for individual patients and in clinical trials. Steady state PERG apparently better discriminates diseased eyes compared to tPERG. The adoption of skin-active electrodes is able to adequately discriminate between healthy and diseased statuses.
FINANCIAL DISCLOSURES
Proprietary or commercial disclosure may be found after the references.
PubMed: 37334035
DOI: 10.1016/j.xops.2023.100322 -
International Ophthalmology Oct 2023To identify the public level of knowledge about the common ophthalmological conditions in Saudi Arabia. (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To identify the public level of knowledge about the common ophthalmological conditions in Saudi Arabia.
METHODS
We searched Medline, Embase, and CENTRAL for relevant literature. We included questionnaire-based cross-sectional studies performed in Saudi Arabia assessing the public awareness and attitude about general knowledge, causes/risk factors, signs/symptoms, disabilities/consequences, and relieving/management measures of the common ophthalmological conditions including glaucoma, cataract, and diabetic retinopathy (DR). The meta-analysis was performed on outcomes reported in ≥ 2 studies utilizing the random-effects model. Quality assessment was done using the Appraisal tool for Cross-Sectional Studies (AXIS) tool.
RESULTS
Twenty-eight studies were deemed eligible for inclusion in this review. A total of 72 questions were reported in ≥ 2 studies and were included in the meta-analysis. The total number of participants was 14,408. The meta-analysis estimated that 57.63% (95% confidence interval (CI) 56.87-60.07%), 69.90% (95% CI 67.02-76.07%), and 68.65% (95% CI 65.94-71.23%) of the Saudi public have you ever heard or read about glaucoma, cataract, and DR, respectively. Of the public surveyed in the included studies, 43.68% (95% CI 41.54-45.85%), 55.43% (95% CI 54.03-56.82%), and 63% (95% CI 60.8-65.1%) believed that glaucoma, cataract, and DR could be treated.
CONCLUSION
This systematic review showed that the level of knowledge among the Saudi population about the common ophthalmological conditions was the highest with respect to cataract, followed by DR and glaucoma. The areas of unsatisfactory level of awareness about the common ophthalmological conditions included risk factors, signs/symptoms, complications, and management options. These areas need to be addressed appropriately by future educational interventions.
Topics: Humans; Diabetic Retinopathy; Saudi Arabia; Cross-Sectional Studies; Glaucoma; Cataract; Diabetes Mellitus
PubMed: 37314586
DOI: 10.1007/s10792-023-02757-4 -
Journal of Glaucoma Aug 2023Cost-effectiveness analyses (CEAs) quantify and compare both costs and measures of efficacy for different interventions. As the costs of glaucoma management to patients,...
PURPOSE
Cost-effectiveness analyses (CEAs) quantify and compare both costs and measures of efficacy for different interventions. As the costs of glaucoma management to patients, payers, and physicians are increasing, we seek to investigate the role of CEAs in the field of glaucoma and how such studies impact clinical management.
METHODS
We adhered to the "Preferred Reporting Items for Systematic Reviews and Meta-analyses" guidelines for our systematic review structure. Eligible studies included any full-text articles that investigated cost-effectiveness or cost-utility as it relates to the field of open angle glaucoma management in the United States. Risk of bias assessment was conducted using the validated Joanna Briggs Institute Critical Appraisal Checklist for Economic Evaluations.
RESULTS
Eighteen studies were included in the review. Dates of publication ranged from 1983 to 2021. Most of the studies were published in the 2000s and performed CEAs in the domains of treatment/therapy, screening, and adherence for patients with primary angle open glaucoma. Of the 18 articles included, 14 focused on treatment, 2 on screening, and 2 on adherence. Most of these studies focused on the cost-effectiveness of different topical medical therapies, whereas only a few studies explored laser procedures, surgical interventions, or minimally invasive procedures. Economic models using decision analysis incorporating state-transition Markov cycles or Montecarlo simulations were widely used, however, the methodology among studies was variable, with a wide spectrum of inputs, measures of outcomes, and time horizons used.
CONCLUSION
Overall, we found that cost-effectiveness research in glaucoma in the United States remains relatively unstructured, resulting in unclear and conflicting implications for clinical management.
Topics: Humans; Glaucoma, Open-Angle; Cost-Benefit Analysis; Intraocular Pressure; Glaucoma; Cost-Effectiveness Analysis
PubMed: 37311022
DOI: 10.1097/IJG.0000000000002249 -
BMC Ophthalmology Jun 2023Micropulse transscleral laser treatment (mTLT) is the latest alternative intraocular pressure (IOP) lowering approach for glaucoma patients. This meta-analysis aims to... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Micropulse transscleral laser treatment (mTLT) is the latest alternative intraocular pressure (IOP) lowering approach for glaucoma patients. This meta-analysis aims to evaluate the efficacy and safety of mTLT and continuous wave transscleral cyclophotocoagulation (CW-TSCPC) for the treatment of glaucoma.
METHODS
We searched the PubMed, Embase, and Cochrane Library of Systematic Reviews databases from January 2000 to July 2022 to identify studies that, evaluated the efficacy and safety of mTLT in glaucoma. There were no restrictions regarding study type, patient age, or type of glaucoma. We analysed the reduction in IOP and the number of anti-glaucoma medications (NOAM), retreatment rates, and complications between mTLT and CW-TSCPC treatment. Publication bias was conducted for evaluating bias. This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline.
RESULTS
We identified 6 eligible studies of which only 2 RCTs and 386 participants with various types of glaucoma at different stages were ultimately included. The results revealed significant IOP decreases after mTLT up to 12 months and significant NOAM reductions at 1 month (WMD=-0.30, 95% CI -0.54 to 0.06), and 3 months (WMD=-0.39, 95% CI -0.64 to 0.14) in mTLT compared to CW-TSCPC. Moreover, the retreatment rates (Log OR=-1.00, 95% CI -1.71 to -0.28), hypotony (Log OR=-1.21, 95% CI -2.26 to -0.16), prolonged inflammation or uveitis (Log OR=-1.63, 95% CI -2.85 to -0.41), and worsening of visual acuity (Log OR=-1.13, 95% CI -2.19 to 0.06) occurred less frequently after mTLT.
CONCLUSION
Our results demonstrated that mTLT could lower the IOP until 12 months after treatment. mTLT seems to have a lower risk of retreatment after the first procedure, and mTLT is superior to CW-TSCPC with respect to safety. Studies with longer follow-up durations and larger sample sizes are necessary in the future.
TRIAL REGISTRATION NUMBER
INPLASY202290120.
Topics: Humans; Glaucoma; Intraocular Pressure; Retreatment; Databases, Factual; Lasers
PubMed: 37308944
DOI: 10.1186/s12886-023-03017-w -
Seminars in Ophthalmology Jan 2024To compare the intraocular pressure (IOP)-lowering effect of different types of surgery available in the literature using a network meta-analysis (NMA) based on a... (Meta-Analysis)
Meta-Analysis Review
Efficacy and Safety of Different Types of Intraocular Pressure-Lowering Surgeries in Patients with Primary Angle Closure (PAC) or PAC Glaucoma: Systematic Review and Network Meta-Analysis of Randomized Clinical Trials.
OBJECTIVE
To compare the intraocular pressure (IOP)-lowering effect of different types of surgery available in the literature using a network meta-analysis (NMA) based on a systematic review.
METHODS
PubMed and the Cochrane database were searched. Randomized clinical trials involving surgical interventions for high IOP for PAC (primary angle closure) or PACG (primary angle closure glaucoma) were included. Descriptive statistics and outcomes were extracted. Bayesian NMA was performed to compare the IOP-lowering effect and the change in the number of antiglaucoma drugs required between baseline and endpoint, as well as success rates.
RESULTS
This NMA included 21 articles with 1237 eyes with PAC or PACG. Interventions were characterised as phacoemulsification (phaco), trabeculectomy, goniosynechialysis (GSL) with viscoelastic or blunt device, goniosurgery (GS) (trabeculotomy or goniotomy), micro-bypass stent (Istent®), endocyclophotocoagulation (ECPL) or various combinations of these procedures. Phaco+GSL [-1.73 (95%CrI: -3.53 to -0.13)] and phaco+GSL+GS [-3.92 (95%CrI: -6.91 to -1.31)] provided better IOP lowering effects than phaco alone. Phaco+trabeculectomy [-3.11 (95%CrI: -5.82 to -0.44)] was inferior to phaco+GSL+GS. Phaco+trabeculectomy [-0.45 (95%CrI: -0.81 to -0.13)] provided a better outcome in terms of reducing the need for antiglaucoma drug compared to phaco alone. There were no differences between the other surgeries in terms of reduction of antiglaucoma drug number and IOP lowering effect. Success rates were similar for all surgical procedures.
CONCLUSIONS
Phaco+GSL+GS showed the most promising results for lowering IOP. Phaco+trabeculectomy resulted in a significant reduction in the number of antiglaucoma drugs compared to phaco alone.
Topics: Humans; Intraocular Pressure; Antiglaucoma Agents; Bayes Theorem; Network Meta-Analysis; Glaucoma, Angle-Closure; Randomized Controlled Trials as Topic; Trabeculectomy; Glaucoma; Phacoemulsification; Treatment Outcome; Retrospective Studies
PubMed: 37296113
DOI: 10.1080/08820538.2023.2223292 -
Ophthalmic Research 2023The iStent (Glaukos Corporation; Laguna Hills, CA, USA) is one of the minimally invasive glaucoma devices. It can be inserted at the time of phacoemulsification or as a... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The iStent (Glaukos Corporation; Laguna Hills, CA, USA) is one of the minimally invasive glaucoma devices. It can be inserted at the time of phacoemulsification or as a stand-alone procedure to lower the intraocular pressure (IOP).
OBJECTIVE
Our aim was to conduct a systematic review and meta-analysis comparing the effect of iStent insertion at the time of phacoemulsification with phacoemulsification alone in patients with ocular hypertension or open-angle glaucoma.
METHODS
We searched EMBASE, MEDLINE (OVID and PubMed), CINAHL, and Cochrane Library for articles published between 2008 and June 2022 (PRISMA 2020 for the checklist). Studies comparing the IOP-lowering effect of iStent with phacoemulsification versus phacoemulsification alone were included. The endpoints were IOP reduction (IOPR) and the mean reduction in the number of glaucoma drops. A quality-effects model was used to compare both surgical groups.
RESULTS
Ten studies were included, reporting on 1,453 eyes. Eight hundred fifty three eyes had the combined iStent and phacoemulsification, and 600 eyes underwent phacoemulsification alone. IOPR was higher in the combined surgery at of 4.7 ± 2 mm Hg compared to 2.8 ± 1.9 mm Hg in phacoemulsification alone. A greater decrease in postoperative eye drops was noted in the combined group having a decrease of 1.2 ± 0.3 eye drops versus of 0.6 ± 0.6 drops in isolated phacoemulsification. The quality effect model showed an IOPR weighted mean difference (WMD) of 1.22 mm Hg (confidence interval [CI]: [-0.43, 2.87]; Q = 315.64; p < 0.01; I2 = 97%) and decreased eye drops WMD 0.42 drops (CI: [0.22, 0.62]; Q = 42.6; p < 0.01; I2 = 84%) between both surgical groups. Subgroup analysis shows that the new generation iStent may be more effective in reducing IOP.
CONCLUSION
iStent has a synergetic effect with phacoemulsification. The reduction of IOP and glaucoma eye drops was higher when iStent is combined with phacoemulsification compared with isolated phacoemulsification.
Topics: Humans; Phacoemulsification; Glaucoma, Open-Angle; Glaucoma Drainage Implants; Glaucoma; Intraocular Pressure; Trabecular Meshwork; Ophthalmic Solutions
PubMed: 37245507
DOI: 10.1159/000531077 -
Graefe's Archive For Clinical and... Jan 2024The association of obstructive sleep apnea (OSA) with development of eye diseases is unclear. This current systematic review and meta-analysis attempts to summarize and... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
The association of obstructive sleep apnea (OSA) with development of eye diseases is unclear. This current systematic review and meta-analysis attempts to summarize and analyze associations between OSA and ocular disorders in the literature.
METHODS
PubMed, EMBASE, Google Scholar, Web Of Science, and Scopus databases were searched from 1901 to July 2022 in accordance with the Preferred Reporting in Systematic Review & Meta-Analysis (PRISMA). Our primary outcome assessed the association between OSA and the odds of developing floppy eyelid syndrome (FES), glaucoma, non-arteritic anterior ischemic optic neuropathy (NAION), retinal vein occlusion (RVO), keratoconus (KC), idiopathic intracranial hypertension (IIH), age-related macular degeneration (AMD), and central serous chorioretinopathy (CSR) through odds ratio calculated at the 95% confidence interval.
RESULTS
Forty-nine studies were included for systematic review and meta-analysis. The pooled OR estimate was highest for NAION [3.98 (95% CI 2.38, 6.66)], followed by FES [3.68 (95% CI 2.18, 6.20)], RVO [2.71(95% CI 1.83, 4.00)], CSR [2.28 (95% CI 0.65, 7.97)], KC [1.87 (95% CI 1.16, 2.99)], glaucoma [1.49 (95% CI 1.16, 1.91)], IIH [1.29 (95% CI 0.33, 5.01)], and AMD [0.92 [95% CI 0.24, 3.58] All observed associations were significant (p < 0.001) aside from IIH and AMD.
CONCLUSION
OSA is significantly associated with NAION, FES, RVO, CSR, KC, and glaucoma. Clinicians should be informed of these associations so early recognition, diagnosis, and treatment of eye disorders can be addressed in at-risk groups, and early referral to ophthalmic services is made to prevent vision disturbances. Similarly, ophthalmologists seeing patients with any of these conditions should consider screening and referring patients for assessment of possible OSA.
Topics: Humans; Eyelid Diseases; Glaucoma; Keratoconus; Optic Neuropathy, Ischemic; Retinal Vein Occlusion; Sleep Apnea, Obstructive
PubMed: 37227479
DOI: 10.1007/s00417-023-06103-3 -
Indian Journal of Ophthalmology May 2023Glaucoma is the second leading cause of blindness in the world, with an estimated 57.5 million people suffering from glaucoma globally. Treatment of glaucoma focuses on... (Meta-Analysis)
Meta-Analysis Review
Glaucoma is the second leading cause of blindness in the world, with an estimated 57.5 million people suffering from glaucoma globally. Treatment of glaucoma focuses on lowering intra-ocular pressure to prevent progression of visual field defects, which is the only proven method for treating this disease. Yoga practices are believed to lower intra-ocular pressure in the eyes and prevent further damage in patients with glaucoma. Therefore, this systematic review was planned to explore the available scientific studies on yoga and intra-ocular pressure in glaucoma patients. PubMed, Cochrane Library, and Google Scholar were the basis for the investigation of the literature. The Jadad Scale was used to assess the quality of included clinical trials, and the JBI Critical Appraisal Checklist was used to assess the quality of included case studies. Based on the quality assessment and eligibility, six studies on yoga and intra-ocular pressure in glaucoma patients carried out between 2007 and 2021 were included in the final review. The results showed a reduction in intra-ocular pressure in patients with glaucoma through Jyoti-trataka (gazing steadily on a point or candle flame) and some other slow yogic breathing techniques, whereas studies on inversion Asanas (yoga postures) showed a rapid increase in intra-ocular pressure soon after starting. The three high-quality RCTs included in the meta-analysis showed a greater improvement in intra-ocular pressure in the yoga groups in both eyes than in the control groups; however, there were some limitations related to a small sample size, study quality, a long-term follow-up period, and variations in the yoga practices. Therefore, further studies with larger sample sizes and long-term follow-up are needed to overcome the limitations for a better understanding.
Topics: Humans; Yoga; Glaucoma; Intraocular Pressure; Tonometry, Ocular; Blindness
PubMed: 37203026
DOI: 10.4103/ijo.IJO_2054_22