Respiration; International Review of... 2023Endoscopic techniques, including endobronchial ultrasound (EBUS) and endoscopic ultrasound (EUS), are used as the initial approach for the diagnosis and staging of lung... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Endoscopic techniques, including endobronchial ultrasound (EBUS) and endoscopic ultrasound (EUS), are used as the initial approach for the diagnosis and staging of lung cancer and the diagnosis of thoracic and abdominal lesions. Historically, the transvascular approach has been avoided because of concerns about bleeding.
OBJECTIVES
This article is a systematic review of studies evaluating the feasibility and safety of transvascular needle aspiration (TVNA) under the guidance of EBUS or EUS in the diagnosis of thoracic and abdominal lesions.
METHODS
We performed a systematic search of the MEDLINE, Embase, and Cochrane databases to identify studies evaluating the application of EBUS/EUS-guided TVNA (EBUS/EUS-TVNA) for lesions located at the contralateral side of the vessel for which the transvascular approach was the best puncture path. We performed a meta-analysis of diagnostic yield estimations. We also reviewed the complications related to the procedure.
RESULTS
Eleven observational studies were included in the final analysis. Meta-analysis yielded a pooled overall diagnostic yield of 82.10% (95% confidence interval, 0.74-0.89) for TVNA, with an I2 value of 52%. No publication bias was detected by Egger's test (p = 0.8528). The overall complications included minor bleeding, minor hematoma, pseudo-aneurysm of the aorta, hemoptysis, acute hypoxic respiratory failure, and moderate bleeding. The major complication rate was 2.71%.
CONCLUSIONS
EBUS/EUS-TVNA is feasible and probably safe when performed by experienced endoscopists in carefully selected patients. In view of the potential risks associated with the transvascular approach, especially the development of hematoma and pseudoaneurysm, the fanning technique was avoided, and the area of aspiration should be assessed by EUS for 3 min after each aspiration. Most importantly, EBUS/EUS-TVNA should only be performed if the results will impact the clinical management.
Topics: Humans; Endosonography; Feasibility Studies; Endoscopic Ultrasound-Guided Fine Needle Aspiration; Lung Neoplasms; Bronchoscopy; Neoplasm Staging; Lymph Nodes; Mediastinum
PubMed: 36646057
DOI: 10.1159/000528529 -
Journal of Endovascular Therapy : An... Jan 2023To evaluate the technical success and complication rates of vascular closure devices (VCDs) in the axillary artery. (Review)
Review
PURPOSE
To evaluate the technical success and complication rates of vascular closure devices (VCDs) in the axillary artery.
MATERIALS AND METHODS
MEDLINE and Embase were searched independently by two reviewers to identify observational studies from inception through October 2021. The following outcomes were meta-analyzed: technical success, hematoma, dissection, pseudoaneurysm, infection, and local neurological complications. Complications were also graded as mild, moderate, and severe. A logistic regression evaluating the influence of sheath size for the outcome of technical success rate was performed using individual patient-level data.
RESULTS
Of 1496 unique records, 20 observational studies were included, totaling 915 unique arterial access sites. Pooled estimates were as follows: technical success 84.8% (95% confidence interval [CI]: 78%-89.7%, I=60.4%), hematoma 7.9% (95% CI: 5.8%-10.6%, I=0%), dissection 3.1% (95% CI: 1.3%-7.3%, I=0%), pseudoaneurysm 2.7% (95% CI: 1.3%-5.7%, I=0%), infection <1% (95% CI: 0%-5.7%, I=20.5%), and local neurological complications 2.7% (95% CI: 1.7%-4.4%, I=0%). There was a significant negative association between sheath size and technical success rate (odds ratio [OR]: 0.87 per 1 French (Fr) increase in sheath size, 95% CI: 0.80-0.94, p=0.0005). Larger sheath sizes were associated with a greater number of access-site complications (adjusted odds ratio [aOR]: 1.21 per 1 Fr increase sheath size, 95% CI: 1.04-1.40, p=0.013).
CONCLUSIONS
Off-label use of VCDs in the axillary artery provides an 85% successful closure rate and variable complication rate, depending on the primary procedure and sheath size. Larger sheaths were associated with a lower technical success and greater rate of access-related complications.
CLINICAL IMPACT
Safe arterial access is the foundation for arterial intervention. While the common femoral artery is a well established access site, alternative arterial access sites capable of larger sheath sizes are needed in the modern endovascular era. This article provides the largest synthesis to date on the use of vascular closure devices for percutaneous axillary artery access in endovascular intervention. It should serve clinicians with added confidence around this approach in terms of providing a reference for technical success and complications. Clinically, this data is relevant for patient consent purposes as well as for practice quality improvement in setting safety standards for this access site.
PubMed: 36625294
DOI: 10.1177/15266028221147451 -
Journal of Vascular and Interventional... Apr 2023To estimate the rates of technical success and adverse events of vascular closure devices (VCDs) in the brachial artery and compare the rates of adverse events with... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
To estimate the rates of technical success and adverse events of vascular closure devices (VCDs) in the brachial artery and compare the rates of adverse events with manual compression.
MATERIALS AND METHODS
MEDLINE and Embase were searched for observational studies examining VCDs in the brachial artery. Meta-analyses were performed using random effects for the following outcomes: (a) technical success, (b) hematoma at the access site, (c) pseudoaneurysm, (d) local neurological adverse events, and (e) total number of adverse events. A pairwise meta-analysis compared VCD with manual compression for the outcomes of hematoma and the total number of adverse events.
RESULTS
Of 1,761 eligible records, 16 studies including 510 access sites were included. Primary procedures performed were peripheral arterial disease interventions, percutaneous coronary intervention, and endovascular thrombectomy for ischemic stroke. The technical success rate was 93% (95% CI, 87%-96%; I = 47%). Data on the following adverse events were obtained via meta-analysis: (a) hematoma, 9% (5%-15%; I = 54%); (b) stenosis or occlusion at access site, 3% (1%-14%; I = 51%); (c) infection, 0% (0%-5%; I = 0%); (d) pseudoaneurysm, 4% (1%-13%; I = 61%); (e) local neurological adverse events, 5% (2%-13%; I = 54%); and (f) total number of adverse events, 15% (10%-22%; I = 51%). Angio-Seal success rate was 96% (93%-98%; I = 0%), whereas the ExoSeal success rate was 93% (69%-99%; I = 61%). When comparing VCD and manual compression, there was no difference in hematoma formation (relative risk, 0.75; 95% CI, 0.35-1.63; I = 0%; P = .47) or the total number of adverse events (relative risk, 0.75; 95% CI, 0.35-1.58; I = 76%; P = .45).
CONCLUSIONS
Despite being off-label, studies suggest that VCDs in the brachial artery have a high technical success rate. There was no significant difference in adverse events between VCDs and manual compression in the brachial artery.
Topics: Humans; Vascular Closure Devices; Brachial Artery; Aneurysm, False; Femoral Artery; Hematoma; Treatment Outcome; Hemostatic Techniques
PubMed: 36526077
DOI: 10.1016/j.jvir.2022.12.022 -
Heliyon Nov 2022Intracranial aneurysms presenting as third ventricular and adjoining part masses are rare and are always associated with obstructive hydrocephalus. It is vital to...
OBJECTIVE
Intracranial aneurysms presenting as third ventricular and adjoining part masses are rare and are always associated with obstructive hydrocephalus. It is vital to provide precise diagnostics and apt treatment for such patients since endovascular or microsurgical operations remain challenging. This study aimed to discuss differential diagnosis tactics based on the cases we followed and the current literature on intracranial aneurysms mimicking third ventricular masses.
METHODS
We followed a case series of intracranial aneurysms presenting as third ventricular masses. Literature reports related to aneurysms adjoining the third ventricle since 1979 were systematically reviewed and summarized.
RESULTS
Twenty-seven cases of this disease were collected. A total of 92.6% of cases developed hydrocephalus. Six cases were reported as third ventricular tumors in primary radiologic reports, and misdiagnosis hindered subsequent clinical decisions. We found a significant correlation between thrombosis and misdiagnosis, as well as between misdiagnosis and craniotomy rate. There are also false negative angiography reports for aneurysms from our cases and literature review. Strategies for the diagnosis and treatment of these aneurysms have changed over time. The uniqueness of our cases sheds light on the use of CT angiography, which has proven to be an appropriate test for diagnosis and reexamination but was not widely applied in previous reports. VW-MRI may be useful to assess rupture risk. Distinct treatment strategies show no significant difference in prognosis.
CONCLUSIONS
Thrombosed aneurysms should be considered as a differential diagnosis in patients with third ventricular masses. Application of CTA and VW-MRI can be beneficial. Aneurysm coil occlusion might be a favorable treatment for cases with mass effects. Further studies should be conducted to confirm our observations.
PubMed: 36458318
DOI: 10.1016/j.heliyon.2022.e11506 -
International Journal of Nursing Studies Jan 2023Hemostasis control after percutaneous endovascular procedures through the femoral approach remains challenging for catheterization laboratory nurses, given method... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Hemostasis control after percutaneous endovascular procedures through the femoral approach remains challenging for catheterization laboratory nurses, given method variability.
OBJECTIVE
To summarize the available evidence on vascular devices efficacy dedicated to hemostasis control compared to the extrinsic compression after percutaneous procedures in the femoral vein or artery.
METHODS
A systematic review with meta-analysis of randomized clinical trials was conducted. We compared different hemostasis methods in adult patients who underwent diagnostic and/or therapeutic procedures through femoral access. The databases searched were PubMed, Embase, CINAHL and Cochrane CENTRAL, and updated on 03/2022. The outcomes included hematoma, pseudoaneurysm, bleeding, minor and major vascular complication, time to hemostasis, device failure, and manual compression repetition. The risk of bias was assessed using the Cochrane Risk of Bias Tool 1.0. Pooled effect sizes on continuous, categorical and proportion variables were estimated with the random effects model. The continuous variables were summarized as the difference between means weighted by the inverse of variance (WMD), and the categorical ones by the summary of relative risks (RR), estimated by the DerSimonian and Laird method. The Freeman-Tukey method was used to estimate the summary effect of proportions.
RESULTS
Fifty articles were included in the systematic review. When compared to extrinsic compression, vascular closure devices resulted in a relative risk reduction (RRR) for hematoma: RR 0.82 [95%CI 0.72 to 0.94] and in shorter time to hemostasis WMD -15.06 min [95%CI -17.56 to -12.56]; no association was observed between interventions with vascular closure devices and extrinsic compression for pseudoaneurysm, bleeding, minor and major vascular complications. Compared to extrinsic compression, sealant or gel type devices were compatible with a RRR for hematoma: RR 0.73 [95%CI 0.59 to 0.90]; and metal clip or staple type devices for pseudoaneurysm: RR 0.48 [95%CI 0.25 to 0.90]; and major vascular complication: RR 0.33 [95%CI 0.17 to 0.64]. For each 100 observations, the device failure rate for metal clip or staple was 3.28% [95%CI 1.69 to 6.27]; for suture 6.84% [95%CI 4.93 to 9.41]; for collagen 3.15% [95%CI 2.24 to 4.41]; and for sealant or gel 7.22% [95% CI 5.49 to 9.45].
CONCLUSIONS
Vascular closure devices performed better in hemostasis control. The certainty of the evidence was rated as very low to moderate.
REGISTRATION
PROSPERO CRD42019140794.
Topics: Adult; Humans; Aneurysm, False; Femoral Artery; Vascular Closure Devices; Hemostasis; Hemorrhage; Hematoma; Treatment Outcome
PubMed: 36399944
DOI: 10.1016/j.ijnurstu.2022.104364 -
Pseudoaneurysms and Orthognathic Surgery: A Systematic Review and a Proposed Algorithm of Treatment.The Journal of Craniofacial Surgery May 2023This study aimed to gather existing evidence regarding the incidence, clinical presentation, and management of pseudoaneurysms (PA) after orthognathic surgery, identify...
This study aimed to gather existing evidence regarding the incidence, clinical presentation, and management of pseudoaneurysms (PA) after orthognathic surgery, identify the common blood vessels involved in PA, and propose a treatment algorithm based on current evidence. The protocol for this study was developed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocols and was registered at the International Prospective Register of Systematic Reviews under the registration number CRD42020205479. Although these are rare, oral and maxillofacial surgeons should consider PA as a possible diagnosis, specifically in the maxillary artery of patients with epistaxis, severe facial edema, and swelling following LeFort I osteotomy.
Topics: Humans; Orthognathic Surgery; Aneurysm, False; Osteotomy; Epistaxis; Algorithms
PubMed: 36377043
DOI: 10.1097/SCS.0000000000009134 -
Journal of Neurointerventional Surgery Mar 2023Subarachnoid hemorrhage from cerebral aneurysm rupture is a major cause of morbidity and mortality. Early aneurysm identification, aided by automated systems, may... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Subarachnoid hemorrhage from cerebral aneurysm rupture is a major cause of morbidity and mortality. Early aneurysm identification, aided by automated systems, may improve patient outcomes. Therefore, a systematic review and meta-analysis of the diagnostic accuracy of artificial intelligence (AI) algorithms in detecting cerebral aneurysms using CT, MRI or DSA was performed.
METHODS
MEDLINE, Embase, Cochrane Library and Web of Science were searched until August 2021. Eligibility criteria included studies using fully automated algorithms to detect cerebral aneurysms using MRI, CT or DSA. Following Preferred Reporting Items for Systematic Reviews and Meta-Analysis: Diagnostic Test Accuracy (PRISMA-DTA), articles were assessed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Meta-analysis included a bivariate random-effect model to determine pooled sensitivity, specificity, and area under the receiver operator characteristic curve (ROC-AUC).
PROSPERO
CRD42021278454.
RESULTS
43 studies were included, and 41/43 (95%) were retrospective. 34/43 (79%) used AI as a standalone tool, while 9/43 (21%) used AI assisting a reader. 23/43 (53%) used deep learning. Most studies had high bias risk and applicability concerns, limiting conclusions. Six studies in the standalone AI meta-analysis gave (pooled) 91.2% (95% CI 82.2% to 95.8%) sensitivity; 16.5% (95% CI 9.4% to 27.1%) false-positive rate (1-specificity); 0.936 ROC-AUC. Five reader-assistive AI studies gave (pooled) 90.3% (95% CI 88.0% - 92.2%) sensitivity; 7.9% (95% CI 3.5% to 16.8%) false-positive rate; 0.910 ROC-AUC.
CONCLUSION
AI has the potential to support clinicians in detecting cerebral aneurysms. Interpretation is limited due to high risk of bias and poor generalizability. Multicenter, prospective studies are required to assess AI in clinical practice.
Topics: Humans; Artificial Intelligence; Intracranial Aneurysm; Sensitivity and Specificity; Retrospective Studies; Algorithms; Multicenter Studies as Topic
PubMed: 36375834
DOI: 10.1136/jnis-2022-019456 -
Frontiers in Surgery 2022This study compared results of non-surgical treatment (compression and ultrasound guided thrombin injection (UGTI)) and surgery to treat iatrogenic femoral artery... (Review)
Review
OBJECTIVES
This study compared results of non-surgical treatment (compression and ultrasound guided thrombin injection (UGTI)) and surgery to treat iatrogenic femoral artery pseudoaneurysms.
METHODS
PubMed and Embase databases were searched up to October 2021. Primary outcome measure was success rate, and other outcomes examined were complication rate, reintervention rate. Two authors independently reviewed and extracted data. Data were presented as the odds ratios (ORs) with 95% confidence intervals (CIs). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was used to appraise the quality of the body of evidence.
RESULTS
Eight studies were included. A total of 623 patients with pseudoaneurysm undergoing treatment were included, of which 163 subjects underwent surgery, 397 subjects underwent compression, and 63 subjects underwent UGTI. The success rate was significantly lower in the non-surgery group (OR 0.24, 95% CI, 0.08-0.69, = 0%). The complication rate was significantly lower in the non-surgery group (OR 0.10, 95% CI, 0.03 -0.29, = 0%). Patients in the non-surgery group tended to have a lower, but statistically insignificant, reintervention rate (OR 0.11, 95% CI, 0.01-1.06, = 35%). Further, the GRADE assessment showed that these results (success rate, complication rate, and reintervention rate) were of very low quality.
CONCLUSIONS
Available evidence shows that it is reasonable to regard non-surgical treatment as the primary treatment for iatrogenic femoral artery pseudoaneurysms, and surgery as a remedy after failure of non-surgical treatment in some cases.
PubMed: 36211300
DOI: 10.3389/fsurg.2022.905701 -
Archivos Espanoles de Urologia Aug 2022Minimally invasive techniques for the treatment and diagnosis of kidney disease seek to preserve the greatest amount of parenchyma. Bleeding after these practices is...
UNLABELLED
Minimally invasive techniques for the treatment and diagnosis of kidney disease seek to preserve the greatest amount of parenchyma. Bleeding after these practices is rare, but must be treated quickly given its severity. Iatrogenic renal vascular injuries (IRVI) resulting from these procedures include active bleeding, arterial pseudoaneurysms, and arteriovenous fistulas. Renal artery embolization (RAE) is the main pillar in the treatment of this type of complications.
OBJECTIVE
To assess the results of RAE for the treatment of IRVI and its impact on the renal function of patients.
METHOD
Retrospective analysis of all patients who presented vascular complications after renal procedures and who were referred for management by RAE, between August 2012 and December 2020.
RESULTS
18 patients were included. 4 patients presented with pseudoaneurysm, 10 patients with active bleeding, and 1 patient with arteriovenous fistula; 2 patients had a combination of different IRVI; 1 patient did not present any findings at the time of renal angiography in dissonance with her computed tomography angiography. Technical and clinical success was achieved in all patients. One renal artery dissection was the only complication. No differences were found in serum creatinine ( = 0.51), urea ( = 0.37), hemoglobin ( = 0.26) and hematocrit ( = 0.24) after embolization.
CONCLUSION
EAR is a safe and effective method for the treatment of IRVI, achieving a very high technical and clinical success rate with a low incidence of complications and without significant repercussions on the renal function of patients.
Topics: Aneurysm, False; Arteriovenous Fistula; Creatinine; Embolization, Therapeutic; Endovascular Procedures; Female; Hemorrhage; Humans; Iatrogenic Disease; Kidney Diseases; Retrospective Studies; Treatment Outcome; Urea; Vascular System Injuries
PubMed: 36138501
DOI: 10.37554/es-j.arch.esp.urol-20210515-3507-27