Journal of Shoulder and Elbow Surgery Jun 2024Rotator cuff tears (RCTs) are a prevalent cause of shoulder pain and dysfunction. For those who fail initial conservative treatment, operative intervention can be... (Review)
Review
INTRODUCTION
Rotator cuff tears (RCTs) are a prevalent cause of shoulder pain and dysfunction. For those who fail initial conservative treatment, operative intervention can be pursued. A significant and common complication after rotator cuff repair (RCR) is retearing or non-healing. Numerous augmentations to traditional suture RCR have been studied. Of these, the Smith+Nephew Regeneten bioinductive collagen patch has had promising initial results; however, analytic data for its use is lacking, and there is no meta-analysis comparing the available data to historical RCR outcomes.
METHODS
A PRISMA-guided literature search was conducted using Ovid MEDLINE, PubMED, Cochrane, and ClinicalTrials.gov. 13 studies met inclusion and exclusion criteria. Only clinical trials on full and partial-thickness tears were included. American Shoulder and Elbow Surgeon score (ASES), Constant-Murley score (CMS), the visual analog scale for pain (VAS), the minimal clinically important difference (MCID), tendon thickness, and complication rates were primary outcomes of interest. A meta-analysis was performed to determine the overall complication and retear rate from the included studies.
RESULTS
ASES, CMS, and VAS improved significantly in all studies that reported them, and most patients achieved MCID. Patient-reported outcome measure (PROM) improvements were similar to historical improvements in standard RCR, and a similar proportion of patients achieved MCID after standard repair. Tendon thickness improved significantly and to a similar degree as standard RCR. Overall retear rate after full thickness RCR augmented with the bioinductive patch was 8.3%. For partial thickness RCR, total retear rate of 1.1% across all patients. The overall complication rate with the bioinductive patch was 15.5% across all full-thickness RCR studies and 16.2% in partial thickness RCR. We found overall retear rate to be lower after augmentation with the bioinductive patch compared to traditional repair; however, the overall complication rate was similar for full-thickness tears and higher for partial-thickness tears. Lastly, adverse reactions to the bioinductive patch were noted at 0.2%.
CONCLUSIONS
The bioinductive collagen patch appears to be a safe augmentation for rotator cuff repair. Patients are likely to experience significant subjective improvement in PROMs and significant increases in tendon thickness. Retear rate has been a concern after RCR for decades, and the bioinductive patch may help mitigate this risk. There is a lack of case-control studies comparing the bioinductive patch to traditional suture RCR. Such data is needed to better determine the role of the bioinductive patch in the treatment of full and partial-thickness rotator cuff repairs.
PubMed: 38942225
DOI: 10.1016/j.jse.2024.05.002 -
Arthroscopy : the Journal of... Jun 2024The objective of the current study was to analyze if the arthroscopic Bankart repair using a knotless suture anchor has a better functional outcome than the conventional... (Review)
Review
PURPOSE
The objective of the current study was to analyze if the arthroscopic Bankart repair using a knotless suture anchor has a better functional outcome than the conventional knot-tying Bankart repair.
METHODS
Comprehensive literature search was done in Pubmed, Scopus, Embase, and Cochrane databases in May 2023. Studies comparing the clinical outcome of Bankart repair using knotless and knot-tying techniques were included in the study. In vitro, animal, and level 4 and 5 studies were excluded. The risk of bias of randomized controlled trials (RCT) was calculated according to the RoB 2 tool, and for non-randomized studies, MINORS criteria were used. Statistical analysis was done using RevMan software.
RESULTS
A total of nine studies, including two RCT and seven non-randomized comparative studies involving 720 patients, were included in the systematic review. The ROWE score ranged 81.7 to 94.3 in the knot-tying and 86 to 96.3 in the knotless group. VAS scores at final follow-up ranged between 0.1 to 1.7 in the knot-tying and 0.7 to 2.5 in the knotless group. The rate of redislocation, subluxation, and revision surgery in the knot-tying group ranged from 0 to 14.7%, 16.7 to 29.7%, and 1.6 to 17.6%, respectively, while that in the knotless group ranged from 2.4 to 23.8%, 7.4 to 22.2%, and 2.4 to 19%, respectively. The mean external rotation was 54 to 65 degrees in the knot-tying and 61 to 99 in the knotless group. The mean forward-flexion was 164 to 172 in the knot-tying and 165 to 174 in the knotless group. Our subjective synthesis doesn't reveal any difference in the outcome between the two groups.
CONCLUSION
The available literature does not demonstrate a clear difference in functional outcomes, residual pain, and rate of complications like redislocation, subluxation and revision surgery between Bankart repair performed with knotted and knotless anchors.
PubMed: 38942097
DOI: 10.1016/j.arthro.2024.05.036 -
Journal of Reconstructive Microsurgery Jun 2024Background Rupture of the extensor mechanism of the knee has severe functional morbidity, and repair can be complicated by infection, allograft degeneration, and...
Background Rupture of the extensor mechanism of the knee has severe functional morbidity, and repair can be complicated by infection, allograft degeneration, and recurrent rupture. Techniques of autologous tissue repair utilizing pedicled flaps such as the gastrocnemius offer vascularized methods of reconstruction, with potentially diminished complication rates. The goal of this study was to evaluate the functional outcomes and complications associated with pedicled flap repair of the knee extensor mechanism. Methods A systematic review was conducted following PRISMA guidelines. Publications that focused on local myocutaneous flaps as a means for reconstruction were included. Causes for knee extensor mechanism deficit, flap characteristics, ambulation rate, changes in range of motion pre- and post-operation, and postoperative complications were analyzed. Technique reports including primary suture repairs, synthetic mesh, and allograft use were excluded. Results An initial 119 studies were identified, with final review of 22 observational studies encompassing 128 cases of pedicled flap reconstructions. The gastrocnemius (88.2%, n=113), quadriceps (6.3%, n=8), and a combination of the vastus and gastrocnemius flaps (5.5%, n=7), were the most frequently utilized flaps. Functional outcomes were favorable with 87.2% of patients achieving ambulation without external support. Variability in range of motion outcomes across different flap may be secondary to the patient characteristics as well as extent of initial injury. Conclusions Autologous pedicle flap reconstruction of the knee extensor mechanism emerges as a viable option for cases characterized by extensive defects and insufficient soft tissue coverage, which are not amenable to direct suture repairs or allografts. Postoperative assessments revealed that the majority of patients experienced improved ambulation status, with no instances of deterioration noted among the patients.
PubMed: 38936419
DOI: 10.1055/a-2355-4073 -
The Journal of Hospital Infection Jun 2024We aimed to compare which suture devices could reduce the incidence of incisional surgical site infections (SSIs) after gastrointestinal surgery using a systematic... (Review)
Review
AIM
We aimed to compare which suture devices could reduce the incidence of incisional surgical site infections (SSIs) after gastrointestinal surgery using a systematic review and network meta-analysis.
METHODS
The CENTRAL, PubMed, and ICHUSHI-Web databases were searched from January 1st, 2000, to December 31st, 2022, for randomised clinical trials (RCTs) comparing the incidence of incisional SSI after gastrointestinal surgery among patients treated with different surgical suture devices, including non-absorbable sutures, absorbable sutures, skin staplers, and tissue adhesives (last searched in August 23th 2023). The risk of bias was assessed using the criteria of the Cochrane Handbook for Systematic Reviews of Interventions. To estimate the pooled odds ratios (ORs) for each comparison, we employed a fixed-effect inverse-variance model based on the Mantel-Haenszel approach. This study was registered in PROSPERO and supported in part by the Japan Surgical Infection Society.
RESULTS
A total of 18 RCTs with 5,496 patients were included in this study. The overall SSIs in absorbable sutures were significantly lower than the ones in skin staplers (OR: 0.77; 95% confidence intervals (CI): 0.63-0.95) and non-absorbable sutures (OR: 0.62; 95% CI: 0.39-0.99). On the other hand, SSIs in absorbable sutures were not statistically different from the SSIs in tissue adhesive. The highest P-score was 0.91 for absorbable sutures. A funnel plot for estimating the heterogeneity of the studies revealed that a publication bias would be minimal (Egger test, P = 0.271).
CONCLUSION
This study showed that absorbable sutures reduced incisional SSIs in gastrointestinal surgical operations compared to any other suture devices.
PubMed: 38901769
DOI: 10.1016/j.jhin.2024.04.029 -
Arquivos Brasileiros de Cirurgia... 2024Umbilical and epigastric hernias are among the most common hernias of the abdominal wall; however, there is a lack of standardization for their treatment.
BACKGROUND
Umbilical and epigastric hernias are among the most common hernias of the abdominal wall; however, there is a lack of standardization for their treatment.
AIMS
To clarify the controversies regarding therapeutic possibilities, indications, and surgical techniques for umbilical and epigastric hernia repair.
METHODS
A systematic review and qualitative analysis of randomized clinical trials published in the last 20 years, involving adults (aged 18 years and over) with umbilical and/or epigastric hernias, was performed by systematically searching the PubMed/Medline, Cochrane, SciELO, and LILACS databases. The risk of bias in individual studies was assessed using the Cochrane Risk of Bias Tool.
RESULTS
Initially, 492 studies were selected and, subsequently, 15 randomized controlled clinical trials were chosen that met the inclusion criteria and underwent full reading and qualitative analysis, considering possible bias.
CONCLUSIONS
This review concluded that it is evident the superiority of the use of meshes in the repair of epigastric/primary umbilical hernias with a defect larger than 1 cm, even in certain emergency situations. However, suture repair is a good option for patients with a defect smaller than 1 cm. In the laparoscopic approach, recent evidence points towards possible superiority in fixation with fibrin sealant, and fascial defect closure is recommended. In addition, due to a scarcity of randomized controlled trials with low risk of bias, further studies are needed on types, positioning and fixation techniques, as well as the real role of video-assisted laparoscopic surgery in the correction of hernias, especially umbilical.
Topics: Humans; Herniorrhaphy; Hernia, Umbilical; Randomized Controlled Trials as Topic; Surgical Mesh; Hernia, Abdominal
PubMed: 38896702
DOI: 10.1590/0102-6720202400014e1807 -
Archives of Orthopaedic and Trauma... Jun 2024The ideal surgical management for tibial eminence avulsion fractures remains controversial with varying approach, methods of fixation and post-operative regimes reported...
PURPOSE
The ideal surgical management for tibial eminence avulsion fractures remains controversial with varying approach, methods of fixation and post-operative regimes reported throughout literature. The current systematic review and meta-analysis aims to compare between the different approaches, methods of fixation and post-operative regimes for tibial eminence fractures.
METHODS
The systematic review was conducted according to PRISMA guidelines. A search was conducted using PubMed, MEDLINE and CINAHL databases. The keywords used were "anterior cruciate ligament", "tibial spine" or "tibial eminence" and "fracture" or "avulsion". All original human studies that reported the surgical outcomes of tibial eminence fractures were included. Individual patient data meta-analysis was performed.
RESULTS
48 studies with 1367 patients were included. Arthroscopic fixation resulted in significantly greater stability in terms of anterior drawer test (p = 0.018) and Lachman's test (p = 0.042), as compared to open fixation, though there was no significant difference for pivot shift test. There was no significant difference identified in functional scores and activity, including Lysholm score, IKDC subjective score, Tegner score and return to sports. Suture fixation had significantly increased stability compared to screw fixation, in terms of anterior drawer test (p = 0.001) and Lachman's test (p = 0.001), though no significant difference was identified for pivot shift test. Significantly better subjective scores and return to activity were also noted for suture fixation, in terms of Lysholm score (p = 0.008), IKDC subjective score (p = 0.001) and Tegner score (p = 0.001), though no significant difference was identified for return to sports.
CONCLUSION
Arthroscopic and suture fixation had significantly superior outcomes when compared to open and screw fixation. Arthroscopic fixation resulted in significantly improved stability of the knee as compared to open fixation, though no significant difference was identified in terms of functional knee scores and return to activity. Suture fixation resulted in significantly improved stability of the knee and functional knee screws as compared to screw fixation.
PubMed: 38896276
DOI: 10.1007/s00402-024-05318-1 -
Frontiers in Oncology 2024Anastomotic leakage (AL) is one of the most serious complications after laparoscopic anus-preserving surgery for rectal cancer, which significantly prolongs the...
BACKGROUND AND OBJECTIVES
Anastomotic leakage (AL) is one of the most serious complications after laparoscopic anus-preserving surgery for rectal cancer, which significantly prolongs the patient's hospital stay, leads to dysfunction, and even increases the patient's perioperative morbidity and mortality, and little is known about the effectiveness of anastomotic reinforcement sutures to prevent AL. Thus, this study was conducted to evaluate the efficacy of anastomotic reinforcement sutures as a means to prevent AL during laparoscopic surgery for rectal cancer.
METHODS
A comprehensive and systematic search was performed in the literature database by combining subject and free terms up to 10 October 2023. The overall literature included was integrated and analyzed using Stata 12.0 software and Review Manager version 5.4 software to assess the effect of anastomotic reinforcement sutures on the incidence of AL.
RESULTS
A total of 2,452 patients from 14 studies were included, and an integrated analysis showed that the use of anastomotic reinforcement sutures significantly reduced the incidence of AL [odds ratio (OR) = 0.26; 95% confidence interval (CI), 0.18-0.37; P < 0.00001; I 0%]. However, the findings confirmed whether or not the anastomosis reinforced with sutures did not affect the incidence of anastomotic stenosis (OR = 0.69; 95% CI, 0.37-1.32; P = 0.27; I = 0%). We performed subgroup analyses of the results of the study, the randomized controlled studies (OR = 0.31; 95% CI, 0.15-0.65; P < 0.001) as well as retrospective studies (OR = 0.28; 95% CI, 0.19-0.41; P < 0.001), 3-0 sutures (OR = 0.28; 95% CI, 0.17-0.45; P < 0.001) versus 4-0 sutures (OR = 0.26; 95% CI, 0.13-0.53; P < 0.001), barbed wire sutures (OR = 0.26; 95% CI, 0.14-0.48; P < 0.001) versus non-barbed wire sutures (OR = 0.30; 95% CI, 0.20-0.46; P < 0.001), interrupted (OR = 0.30, 95% CI, 0.20-0.46; P < 0.001) versus continuous sutures (OR = 0.29, 95% CI, 0.16-0.51; P < 0.001) to the anastomosis, full-thickness suture (OR = 0.29; 95% CI, 0.16-0.51; P < 0.001) versus sutured with the seromuscular layer (OR = 0.27; 95% CI, 0.14-0.53; P < 0.001), anastomotic sutured in one (OR = 0.27; 95% CI, 0.14-0.53; P < 0.001) versus non-one circle (OR = 0.30; 95% CI, 0.20-0.44; P < 0.001), and reinforcing sutures to the dog-ear area (OR = 0.26; 95% CI, 0.14-0.50; P < 0.001) versus the non-dog-ear area (OR = 0.30; 95% CI, 0.20-0.45; P < 0.001), which have suggested that there is no significant difference between each other and that all of them reduce the incidence of AL.
CONCLUSIONS
This study provides evidence that performing reinforcement suturing of the anastomosis during laparoscopic rectal surgery significantly lowers the incidence of postoperative AL but has no significant effect on anastomotic stenosis. It is important to note that further randomized controlled studies are required to confirm this conclusion.
SYSTEMATIC REVIEW REGISTRATION
https://www.crd.york.ac.uk/PROSPERO/, identifier CRD42022368631.
PubMed: 38894871
DOI: 10.3389/fonc.2024.1337870 -
Journal of Clinical Medicine Jun 2024: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this... (Review)
Review
: The Carlevale lens (FIL SSF, Soleko IOL Division, Italy) is a new lens for suture-less scleral fixation. This paper aimed to systematically review articles on this lens, the surgical techniques used for its implantation, complications and outcomes. : This systematic review was performed following the PRISMA guidelines. The search string used was "Carlevale" AND "scleral fixation" from inception until March 2024. For completeness, either case-control studies, case reports or case series written in English were included. The authors used the Newcastle-Ottawa scale for the case-control studies and the JBI Critical Appraisal Checklist for case reports and case series. : Twenty-nine articles were included. Scleral fixation with Carlevale lens can be performed by creating scleral flaps or, alternatively, by using scleral pockets. The two sclerotomies must be diametrically opposed, and are preferably created by 25-gauge trocars. A pars plana vitrectomy should be performed every time, and the design of the lens should be suitable for self-anchoring to the sclera; the most accredited strategy to achieve this is to avoid scleral sutures. There were only a few intraoperative and postoperative complications reported; vitreous hemorrhages were the most frequent intraoperative events, while the most relevant postoperative complications were vitreous hemorrhages, cystoid macular oedema and transient variations in the intraocular pressure. Excellent results have been obtained in terms of BCVA, IOL centration and stability, mean intraocular pressure, postoperative spherical equivalent, separation between anterior and posterior chamber and the distance of the IOL from anterior chamber structures. : The foldable hydrophilic design of the Carlevale lens has shown good effectiveness, IOL stability and few intra and post-operative complications.
PubMed: 38892997
DOI: 10.3390/jcm13113287 -
Journal of Clinical Medicine May 2024The purpose of the study is to compare the visual outcomes and complications of sutured scleral fixation (SSF), a traditional and conservative surgical approach, and... (Review)
Review
The purpose of the study is to compare the visual outcomes and complications of sutured scleral fixation (SSF), a traditional and conservative surgical approach, and the newer and faster Yamane technique for secondary intraocular lens placement. A literature search was performed on PubMed, Embase, and Scopus on studies published between 1 July 2017 to 29 September 2023. Outcomes analyzed included the final best corrected visual acuity (BCVA) between 3 and 12 months to assess the effectiveness of the procedure, post-operative month (POM) 1 BCVA to assess the speed of visual recovery, endothelial cell count (ECC), absolute refractive error, surgical duration, and complication rates. Additional subgroup analyses were performed based on surgeon experience with the technique. Single-surgeon studies had an average of 26 procedures performed, whereas multiple-surgeon studies averaged only 9 procedures performed; these were then used to delineate surgeon experience. A sample-size weighted mean difference (MD) meta-analysis was performed across all variables using RevMan 5.4.1; < 0.05 was considered statistically significant. Thirteen studies with 737 eyes were included: 406 eyes were included in the SSF group, and 331 eyes were included in the Yamane group. There was no significant difference in the final BCVA between groups in both the single-surgeon versus multiple-surgeon studies (MD = -0.01, 95% CI: [-0.06, 0.04], = 0.73). In the single-surgeon studies, the BCVA at POM1 was significantly improved in the Yamane group compared to SSF (MD = -0.10, 95% CI: [-0.16, -0.04], = 0.002). In the multiple-surgeon studies, there was no significant difference in BCVA at POM1 (MD = -0.06, 95% CI: [-0.16, 0.04], = 0.23). The Yamane group had a shorter surgical duration than SSF in both single-surgeon and multiple-surgeon studies (MD = -24.68, 95% CI: [-35.90, -13.46], < 0.0001). The ECC, refractive error, and complication rates did not significantly differ amongst all groups. The Yamane technique demonstrated similar long-term visual outcomes and complication rates to the traditional SSF. Visual recovery was significantly faster in the Yamane group in the single-surgeon studies. The operative times were shorter across all Yamane groups. Based on these findings, it is advisable to consider the Yamane technique as a viable, and perhaps preferable, option for patients requiring secondary IOL placement, alongside traditional SSF methods.
PubMed: 38892783
DOI: 10.3390/jcm13113071 -
Healthcare (Basel, Switzerland) May 2024Total hip arthroplasty is among the most successful procedures in orthopaedic surgery. As the total number of total hip arthroplasties is constantly rising and it is... (Review)
Review
PURPOSE
Total hip arthroplasty is among the most successful procedures in orthopaedic surgery. As the total number of total hip arthroplasties is constantly rising and it is expected to further increase, efforts oriented to optimise surgical pathways are investigated, aiming to reduce complications and diminish costs. The wound suturing phase is one of the steps that may be addressed. Barbed sutures have proved to reduce surgical times and enhance suture stability, then reducing wound-related complications in many surgical fields. The evidence on the use of this technology in total hip arthroplasty is still sparse, and its effect on patient outcomes and costs must still be clarified.
METHODS
A systematic search of studies published from 1 January 2000 to 1 March 2023 was performed. Two authors independently reviewed the literature available in eight electronic databases to identify papers eligible for inclusion.
RESULTS
A total of nine studies investigating 6959 procedures on 6959 patients were included in the final analysis. Five studies were randomised controlled trials, and the overall quality of studies ranged from moderate to high. The mean age of patients ranged from 43.8 to 70 years. BMI ranged from 25 to 31.9 kg/m. The mean follow-up of studies ranged from 3 to 6 months.
CONCLUSIONS
Evidence included in the systematic review suggested that the use of barbed sutures is associated with lower suturing times, complication rates, and overall costs when compared to the use of traditional suturing techniques.
LEVEL OF EVIDENCE
II, systematic review of level I and II studies.
PubMed: 38891138