Noise & HealthOtitis media (OM) refers to a common clinical ear disease. Noise seriously damages human hearing function. This study aimed to investigate the effects of various noise...
BACKGROUND
Otitis media (OM) refers to a common clinical ear disease. Noise seriously damages human hearing function. This study aimed to investigate the effects of various noise types on the hearing function of patients who have recovered from mild OM.
MATERIALS AND METHODS
A total of 160 patients with mild OM treated at our hospital from May 2020 to May 2023 were retrospectively selected for this study. Based on clinical data, the patients were divided into the non-noise group (n = 80) and the noise (n = 80) group. The hearing thresholds of the two groups were compared across various noise types at 500, 1000, and 2000 Hz. In addition, the hearing thresholds of the noise group were compared under the same conditions.
RESULTS
The noise group exhibited significantly higher hearing thresholds at 500, 1000, and 2000 Hz than the non-noise group (P < 0.05). Under traffic, urban construction, and industrial noises, the auditory thresholds at 500, 1000, and 2000 Hz in the noise group were significantly higher than those observed under domestic and speech noises (P < 0.05).
CONCLUSION
Noise shows a close relationship with the hearing function of patients with OM. Traffic, urban construction, and industrial noises greatly influence the hearing function of patients who have recovered from mild OM.
Topics: Humans; Otitis Media; Male; Female; Adult; Middle Aged; Retrospective Studies; Auditory Threshold; Noise; Hearing Loss, Noise-Induced; Aged
PubMed: 38904828
DOI: 10.4103/nah.nah_6_24 -
Noise & HealthDigital noise reduction (DNR) minimizes the effect of noise on speech signals by continuously monitoring frequency bands in the presence of noise. In the present study,...
AIMS
Digital noise reduction (DNR) minimizes the effect of noise on speech signals by continuously monitoring frequency bands in the presence of noise. In the present study, we explored the effect of DNR technology on speech intelligibility in individuals using hearing aids (HAs) and investigated implications for daily use.
METHODS AND MATERIAL
Eighteen participants with bilateral moderate sensorineural hearing loss (aged 16-45 years) were included. Bilateral receiver-in-the-ear HAs were fitted in the participants. The adaptive and nonadaptive (with a signal-to-noise ratio (SNR) of +5 and -5 dB, respectively) Turkish matrix sentence test (TURMatrix) in noise and free-field hearing assessments, including hearing thresholds with hearing aids, speech recognition thresholds (SRT), and speech discrimination scores, were conducted in two different conditions: HA in the DNR-on and DNR-off conditions.
RESULTS
No significant difference was observed between free-field hearing assessments with the HA in the DNR-off and DNR-on conditions (P > 0.05). Furthermore, the adaptive and nonadaptive TURMatrix revealed significant differences between the scores under the DNR-on and DNR-off conditions (P < 0.05). Nevertheless, under the DNR-on condition, there was no correlation between free-field hearing assessments with HA and TURMatrix results (P > 0.05). However, a significant correlation was observed between SRT scores with HA and TURMatrix scores (adaptive and nonadaptive, +5 and -5 dB SNR, respectively) under the DNR-off condition (P < 0.05).
CONCLUSION
Our study findings suggest that DNR can improve speech intelligibility in noisy environments. Therefore, DNR can enhance an individual's auditory comfort by improving their capacity to grasp speech in background noise.
Topics: Humans; Hearing Aids; Adult; Noise; Male; Middle Aged; Hearing Loss, Sensorineural; Female; Young Adult; Adolescent; Speech Intelligibility; Signal-To-Noise Ratio; Auditory Threshold; Speech Perception; Speech Reception Threshold Test
PubMed: 38904826
DOI: 10.4103/nah.nah_67_23 -
Frontiers in Veterinary Science 2024Even with recent research advances, effective delivery of a compound to its target cells inside the inner ear remains a challenging endeavor due to anatomical and...
INTRODUCTION
Even with recent research advances, effective delivery of a compound to its target cells inside the inner ear remains a challenging endeavor due to anatomical and physiological barriers. Direct intracochlear drug administration with an inner ear catheter (IEC) aims to overcome this obstacle and strives to provide a safe and efficient way for inner ear pharmacotherapy. The goal of this study was to histologically and audiologically evaluate the traumatic properties of a novel IEC for intracochlear drug delivery in a large animal model.
METHODS
Seven inner ears of piglets that had undergone intracochlear fluorescein isothiocyanate dextran application via an IEC ( = 4) or round window membrane (RWM) puncture with a needle ( = 3) followed by sequential apical perilymph sampling were histologically analyzed. Additionally, obtained objective auditory compound action potential and cochlear microphonic measurements were compared. Cochlear cryosections were stained using hematoxylin and eosin, and preservation of inner ear structures was investigated. Moreover, one cochlea was methylmethacrylate-embedded and analyzed with the IEC .
RESULTS
Histological evaluation revealed an atraumatic insertion and subsequent compound application in a majority of IEC-inserted inner ears. Click cochlear compound action potential (CAP) shifts in the IEC groups reached a maximum of 5 dB (1.25 ± 2.5 dB) post administration and prior to perilymph sampling. In comparison, application by RWM puncture generated a maximum click CAP hearing threshold shift of 50 dB (23.3 ± 23.1 dB) coinciding with coagulated blood in the basal cochlear turn in one specimen of the latter group. Furthermore, histology showed an atraumatic insertion of the IEC demonstrating preserved intracochlear structures.
CONCLUSION
The IEC appears to be a promising and efficient way for inner ear drug delivery. The similarities between the porcine and human inner ear enhance the clinical translation of our findings and increase confidence regarding the safe applicability of the IEC in human subjects.
PubMed: 38903692
DOI: 10.3389/fvets.2024.1397554 -
Consciousness and Cognition Jun 2024The level-of-processing (LoP) hypothesis postulates that transition from unaware to aware visual stimuli is either graded or dichotomous depending on the depth of...
The level-of-processing (LoP) hypothesis postulates that transition from unaware to aware visual stimuli is either graded or dichotomous depending on the depth of stimulus processing. Humans can be progressively aware of the low-level features, such as colors or shapes, while the high-level features, such as semantic category, enter consciousness in an all-or none fashion. Unlike in vision, sounds always unfold in time, which might require mechanisms dissimilar from visual processing. We tested the LoP hypothesis in hearing for the first time by presenting participants with words of different categories, spoken in different pitches near the perceptual threshold. We also assessed whether different electrophysiological correlates of consciousness, the auditory awareness negativity (AAN) and late positivity (LP), were associated with LoP. Our findings indicate that LoP also applies to the auditory modality. AAN is an early correlate of awareness independent of LoP, while LP was modulated by awareness, performance accuracy and the level of processing.
PubMed: 38901129
DOI: 10.1016/j.concog.2024.103720 -
PloS One 2024Neurons of the lateral superior olive (LSO) in the auditory brainstem play a fundamental role in binaural sound localization. Previous theoretical studies developed...
Neurons of the lateral superior olive (LSO) in the auditory brainstem play a fundamental role in binaural sound localization. Previous theoretical studies developed various types of neuronal models to study the physiological functions of the LSO. These models were usually tuned to a small set of physiological data with specific aims in mind. Therefore, it is unclear whether and how they can be related to each other, how widely applicable they are, and which model is suitable for what purposes. In this study, we address these questions for six different single-compartment integrate-and-fire (IF) type LSO models. The models are divided into two groups depending on their subthreshold responses: passive (linear) models with only the leak conductance and active (nonlinear) models with an additional low-voltage-activated potassium conductance that is prevalent among the auditory system. Each of these two groups is further subdivided into three subtypes according to the spike generation mechanism: one with simple threshold-crossing detection and voltage reset, one with threshold-crossing detection plus a current to mimic spike shapes, and one with a depolarizing exponential current for spiking. In our simulations, all six models were driven by identical synaptic inputs and calibrated with common criteria for binaural tuning. The resulting spike rates of the passive models were higher for intensive inputs and lower for temporally structured inputs than those of the active models, confirming the active function of the potassium current. Within each passive or active group, the simulated responses resembled each other, regardless of the spike generation types. These results, in combination with the analysis of computational costs, indicate that an active IF model is more suitable than a passive model for accurately reproducing temporal coding of LSO. The simulation of realistic spike shapes with an extended spiking mechanism added relatively small computational costs.
Topics: Models, Neurological; Superior Olivary Complex; Action Potentials; Neurons; Humans; Computer Simulation; Olivary Nucleus; Animals; Sound Localization
PubMed: 38900820
DOI: 10.1371/journal.pone.0304832 -
Diagnostics (Basel, Switzerland) Jun 2024Hearing impairment among adults with intellectual disability (ID) is notably prevalent yet frequently underdiagnosed due, in part, to the challenges associated with...
Hearing impairment among adults with intellectual disability (ID) is notably prevalent yet frequently underdiagnosed due, in part, to the challenges associated with traditional hearing screening methods in this population. This study explores the effectiveness of the Digit-in-Noise (DIN) test as a viable alternative for hearing screening within natural settings and with familiar personnel. A total of 16 Hebrew-speaking adults with ID were recruited from supported employment programs, 10 of whom completed the study. The DIN test, which was administered in a daily environment using a simple digital device, evaluated the speech recognition threshold in noise. Results indicated that while some participants performed comparably to typically developing individuals, others showed varying levels of hearing thresholds, suggesting diverse auditory capabilities within the ID population. This pilot study confirms that the DIN test can be feasibly integrated into routine care settings, offering a friendly and accessible method for assessing hearing abilities in adults with ID. The findings advocate for the broader adoption of and potential modifications to the DIN Test to enhance its applicability and inclusiveness, thereby improving diagnostic accuracy and subsequent auditory care for this underserved population.
PubMed: 38893727
DOI: 10.3390/diagnostics14111202 -
Journal of Otolaryngology - Head & Neck... 2024The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate...
OBJECTIVE
The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes.
METHODS
In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski.
RESULTS
Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS.
CONCLUSION
Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.
Topics: Humans; Retrospective Studies; Male; Female; Cochlear Implantation; Middle Aged; Adult; Cochlear Implants; Follow-Up Studies; Hearing; Aged; Auditory Threshold; Adolescent; Child, Preschool; Treatment Outcome; Child; Electrodes, Implanted; Young Adult; Prosthesis Design; Hearing Loss; Time Factors
PubMed: 38888946
DOI: 10.1177/19160216241250351 -
Trends in Hearing 2024This multi-center study examined the safety and effectiveness of cochlear implantation of children between 9 and 11 months of age. The intended impact was to support...
This multi-center study examined the safety and effectiveness of cochlear implantation of children between 9 and 11 months of age. The intended impact was to support practice regarding candidacy assessment and prognostic counseling of pediatric cochlear implant candidates. Data in the clinical chart of children implanted at 9-11 months of age with Cochlear Ltd devices at five cochlear implant centers in the United States and Canada were included in analyses. The study included data from two cohorts implanted with one or two Nucleus devices during the periods of January 1, 2012-December 31, 2017 (Cohort 1, n = 83) or between January 1, 2018 and May 15, 2020 (Cohort 2, n = 50). Major adverse events (requiring another procedure/hospitalization) and minor adverse events (managed with medication alone or underwent an expected course of treatment that did not require surgery or hospitalization) out to 2 years post-implant were monitored and outcomes measured by audiometric thresholds and parent-reports on the IT-MAIS and LittlEARS questionnaires were collected. Results revealed 60 adverse events in 41 children and 227 ears implanted (26%) of which 14 major events occurred in 11 children; all were transitory and resolved. Improved hearing with cochlear implant use was shown in all outcome measures. Findings reveal that the procedure is safe for infants and that they show clear benefits of cochlear implantation including increased audibility and hearing development.
Topics: Humans; Infant; Cochlear Implantation; Male; Female; Cochlear Implants; Treatment Outcome; Canada; United States; Time Factors; Retrospective Studies; Auditory Threshold; Postoperative Complications
PubMed: 38887094
DOI: 10.1177/23312165241261480 -
International Journal of Pediatric... Jun 2024The neural response telemetry (NRT) is a standard procedure in cochlear implantation mostly used to determine the functionality of implanted device and to check auditory...
INTRODUCTION
The neural response telemetry (NRT) is a standard procedure in cochlear implantation mostly used to determine the functionality of implanted device and to check auditory nerve responds to the stimulus. Correlation between NRT measurements and subjective threshold (T) and maximum comfort (C) levels has been reported but results are inconsistent, and it is still not clear which of the NRT measurements could be the most useful in predicting fitting levels.
PURPOSE
In our study we aimed to investigate which NRT measurement corresponds better to fitting levels. Impedance (IMP), Evoked Action Potential (ECAP) threshold and amplitude growth function (AGF) slope values were included in the study. Also, we tried to identify cochlear area at which the connection between NRT measurements and fitting levels would be the most pronounced.
MATERIALS AND METHODS
Thirty-one children implanted with Cochlear device were included in this retrospective study. IMP, ECAP thresholds and AGF were obtained intra-operatively and 12 months after surgery at electrodes 5, 11 and 19 as representative for each part of cochlea. Subjective T and C levels were obtained 12 months after the surgery during cochlear fitting.
RESULTS
ECAP thresholds obtained 12 months after surgery showed statistically significant correlation to both T and C levels at all 3 selected electrodes. IMP correlated with C levels while AGF showed tendency to correlate with T levels. However, these correlations were not statistically significant for all electrodes.
CONCLUSION
ECAP threshold measurements correlated to T and C values better than AGF slope and IMP. Measurements obtained twelve months after surgery seems to be more predictive of T and C values compared to intra-operative measurements. The best correlation between ECAP threshold and T and C values was found at electrode 11 suggesting NRT measurements at mid-portion cochlear region to be the most useful in predicting fitting levels.
PubMed: 38885546
DOI: 10.1016/j.ijporl.2024.112001 -
Indian Journal of Otolaryngology and... Jun 2024The present study attempted to understand the association between Auditory neuropathy spectrum disorder (ANSD) and Sickle cell anemia (SCA) and to recognize possible...
The present study attempted to understand the association between Auditory neuropathy spectrum disorder (ANSD) and Sickle cell anemia (SCA) and to recognize possible causative factors for the presence of ANSD in SCA individuals. Two cases, 24 years male and 17years female with a laboratory-confirmed diagnosis of Sickle cell anemia underwent detailed audiological evaluation i.e., pure tone audiometry, speech audiometry, immittance audiometry, otoacoustic emission, and auditory brainstem responses. Audiological evaluation revealed a bilateral moderate low-frequency sensorineural hearing loss in male and bilateral moderately severe sensorineural Hearing loss in female case with elevated Speech Recognition Threshold and poor Speech Identification Scores. 'A' type tympanogram with the absence of Acoustic reflexes and the presence of Otoacoustic emission with no distinct and reproducible peak V in Auditory Brainstem Response (ABR) at 90 dBnHL with the presence of ringing cochlear microphonics on polarity reversal collectively indicating bilateral ANSD in both cases. ANSD and SCA are reported to have a genetic basis of etiology. There might be possibilities that one genetic condition may be common in manifesting both conditions or one genetic condition can cause the presence of another genetic condition or can exaggerate the evolution of another genetic condition. Also, abnormal ABR findings indicate the possibility of neuropathological involvement in isolation or in combination with genetic abnormalities that need detailed investigation to understand non-genetic causative factors. Thus, paved the path for further research in this line and might provide better rehabilitative options.
PubMed: 38883506
DOI: 10.1007/s12070-024-04477-2