World Journal of Surgical Oncology Jun 2024This study aimed to evaluate the oncological and reproductive outcomes of fertility-preserving re-treatment in progestin-resistant endometrial carcinoma (EC) and...
OBJECTIVE
This study aimed to evaluate the oncological and reproductive outcomes of fertility-preserving re-treatment in progestin-resistant endometrial carcinoma (EC) and atypical endometrial hyperplasia (AEH) women who desire to maintain their fertility.
METHODS
Our study included 61 progestin-resistant EC/AEH patients. These patients underwent treatment with gonadotropin-releasing hormone agonist (GnRHa) solely or a combination of GnRHa with levonorgestrel-releasing intrauterine system (LNG-IUD) or aromatase inhibitor (AI). Histological evaluations were performed every 3-4 months. Upon achieving complete remission (CR), we recommended maintenance treatments including LNG-IUD, cyclical oral contraceptives, or low-dose cyclic progestin until they began attempting conception. Regular follow-up was conducted for all patients. The chi-square method was utilized to compare oncological and fertility outcomes, while the Cox proportional hazards regression analysis helped identify risk factors for CR, recurrence, and pregnancy.
RESULTS
Overall, 55 (90.2%) patients achieved CR, including 90.9% of AEH patients and 89.7% of EC patients. The median re-treatment time was 6 months (ranging from 3 to 12 months). The CR rate for GnRHa alone, GnRHa + LNG-IUD and GnRHa + AI were 80.0%, 91.7% and 93.3%, respectively. After a median follow-up period of 36 months (ranging from 3 to 96 months), 19 women (34.5%) experienced recurrence, 40.0% in AEH and 31.4% in EC patients, with the median recurrence time of 23 months (ranging from 6 to 77 months). Among the patients who achieved CR, 39 expressed a desire to conceive, 20 (51.3%) became pregnant, 11 (28.2%) had successfully deliveries, 1 (5.1%) was still pregnant, while 8 (20.5%) suffered miscarriages.
CONCLUSION
GnRHa-based fertility-sparing treatment exhibited promising oncological and reproductive outcomes for progestin-resistant patients. Future larger multi-institutional studies are necessary to confirm these findings.
Topics: Humans; Female; Endometrial Neoplasms; Adult; Retrospective Studies; Fertility Preservation; Endometrial Hyperplasia; Progestins; Follow-Up Studies; Pregnancy; Drug Resistance, Neoplasm; Gonadotropin-Releasing Hormone; Levonorgestrel; Middle Aged; Prognosis; Intrauterine Devices, Medicated; Neoplasm Recurrence, Local; Pregnancy Rate; Aromatase Inhibitors; Antineoplastic Agents, Hormonal
PubMed: 38918837
DOI: 10.1186/s12957-024-03439-w -
Radiotherapy and Oncology : Journal of... Jun 2024In this study, we assessed the robustness of intensity modulated proton therapy (IMPT) in esophageal cancer for anatomical variations during treatment.
BACKGROUND AND PURPOSE
In this study, we assessed the robustness of intensity modulated proton therapy (IMPT) in esophageal cancer for anatomical variations during treatment.
METHODS
The first sixty esophageal cancer patients, treated clinically with chemoradiotherapy were included. The treatment planning strategy was based on an internal target volume (ITV) approach, where the ITV was created from the clinical target volumes (CTVs) delineated on all phases of a 4DCT. For optimization, a 3 mm isotropic margin was added to the ITV, combined with robust optimization using 5 mm setup and 3 % range uncertainty. Each patient received weekly repeat CTs (reCTs). Robust plan re-evaluation on all reCTs, and a robust dose summation was performed. To assess the factors influencing ITV coverage, a multivariate linear regression analysis was performed. Additionally, clinical adaptations were evaluated.
RESULTS
The target coverage was adequate (ITV V94%>98 % on the robust voxel-wise minimum dose) on most reCTs (91 %), and on the summed dose in 92 % of patients. Significant predictors for ITV coverage in the multivariate analysis were diaphragm baseline shift and water equivalent depth (WED) of the ITV in the beam direction. Underdosage of the ITV mainly occurred in week 1 and 4, leading to treatment adaptation of eight patients, all on the first reCT.
CONCLUSION
Our IMPT treatment of esophageal cancer is robust for anatomical variations. Adaptation appears to be most effective in the first week of treatment. Diaphragm baseline shifts and WED are predictive factors for ITV underdosage, and should be incorporated in an adaptation protocol.
PubMed: 38917884
DOI: 10.1016/j.radonc.2024.110409 -
PloS One 2024Orexin-mediated stimulation of orexin receptors 1/2 (OX[1/2]R) may stimulate the diaphragm and genioglossus muscle via activation of inspiratory neurons in the...
Orexin receptor 2 agonist activates diaphragm and genioglossus muscle through stimulating inspiratory neurons in the pre-Bötzinger complex, and phrenic and hypoglossal motoneurons in rodents.
Orexin-mediated stimulation of orexin receptors 1/2 (OX[1/2]R) may stimulate the diaphragm and genioglossus muscle via activation of inspiratory neurons in the pre-Bötzinger complex, which are critical for the generation of inspiratory rhythm, and phrenic and hypoglossal motoneurons. Herein, we assessed the effects of OX2R-selective agonists TAK-925 (danavorexton) and OX-201 on respiratory function. In in vitro electrophysiologic analyses using rat medullary slices, danavorexton and OX-201 showed tendency and significant effect, respectively, in increasing the frequency of inspiratory synaptic currents of inspiratory neurons in the pre-Bötzinger complex. In rat medullary slices, both danavorexton and OX-201 significantly increased the frequency of inspiratory synaptic currents of hypoglossal motoneurons. Danavorexton and OX-201 also showed significant effect and tendency, respectively, in increasing the frequency of burst activity recorded from the cervical (C3-C5) ventral root, which contains axons of phrenic motoneurons, in in vitro electrophysiologic analyses from rat isolated brainstem-spinal cord preparations. Electromyogram recordings revealed that intravenous administration of OX-201 increased burst frequency of the diaphragm and burst amplitude of the genioglossus muscle in isoflurane- and urethane-anesthetized rats, respectively. In whole-body plethysmography analyses, oral administration of OX-201 increased respiratory activity in free-moving mice. Overall, these results suggest that OX2R-selective agonists enhance respiratory function via activation of the diaphragm and genioglossus muscle through stimulation of inspiratory neurons in the pre-Bötzinger complex, and phrenic and hypoglossal motoneurons. OX2R-selective agonists could be promising drugs for various conditions with respiratory dysfunction.
Topics: Animals; Diaphragm; Motor Neurons; Orexin Receptors; Rats; Phrenic Nerve; Mice; Male; Hypoglossal Nerve; Rats, Sprague-Dawley; Inhalation; Medulla Oblongata; Isoquinolines; Pyridines
PubMed: 38917189
DOI: 10.1371/journal.pone.0306099 -
Magma (New York, N.Y.) Jun 2024To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric k-k k-space trajectory combined with high-resolution deep learning...
PURPOSE
To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric k-k k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR).
METHODS
All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric k-k trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables.
RESULTS
The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR.
CONCLUSION
Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.
PubMed: 38916681
DOI: 10.1007/s10334-024-01172-9 -
Minerva Surgery Jun 2024
PubMed: 38916539
DOI: 10.23736/S2724-5691.24.10357-7 -
Journal of Anesthesia, Analgesia and... Jun 2024Noninvasive ventilation (NIV) is widely employed as the initial treatment for patients with chronic acute exacerbation of obstructive pulmonary disease (AECOPD)....
Effect of high-flow nasal cannula at different flow rates on diaphragmatic function in subjects recovering from an acute exacerbation of COPD: a physiological prospective pilot study.
BACKGROUND
Noninvasive ventilation (NIV) is widely employed as the initial treatment for patients with chronic acute exacerbation of obstructive pulmonary disease (AECOPD). Nevertheless, high-flow nasal cannula (HFNC) has been increasingly utilized and investigated to mitigate the issues associated with NIV. Flow rate may play a significant role in diaphragmatic function among subjects recovering from AECOPD. Based on these observations, we conducted a physiological study to assess the impact of HFNC therapy on diaphragmatic function, as measured by US, respiratory rate (RR), gas exchange, and patient comfort at various flow rates.
METHODS
A prospective physiological pilot study enrolled subjects with a diagnosis of AECOPD who required NIV for more than 24 h. After stabilization, these subjects underwent a 30-min trial using NIV and HFNC at different sequential flow rates (30-60 L/min). At the end of each trial, diaphragmatic displacement (DD, cm) and diaphragmatic thickness fraction (DTF, %) were measured using ultrasound. Additionally, other physiological variables, such as RR, gas exchange, and patient comfort, were recorded.
RESULTS
A total of 20 patients were included in the study. DD was no different among trials (p = 0.753). DTF (%) was significantly lower with HFNC-30 L/min compared to HFNC-50 and 60 L/min (p < 0.001 for all comparisons). No significant differences were found in arterial pH and PCO at discontinuation of NIV and at the end of HFNC trials (p > 0.050). During HFNC trials, RR remained unchanged without statistically significant differences (p = 0.611). However, we observed that HFNC improved comfort compared to NIV (p < 0.001 for all comparisons). Interestingly, HFNC at 30 and 40 L/min showed greater comfort during trials.
CONCLUSIONS
In subjects recovering from AECOPD and receiving HFNC, flows above 40 L/min may not offer additional benefits in terms of comfort and decreased respiratory effort. HFNC could be a suitable alternative to COT during breaks off NIV.
PubMed: 38915126
DOI: 10.1186/s44158-024-00173-3 -
Thorax Jun 2024Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm...
RATIONALE
Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape.
OBJECTIVES
To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves.
METHODS
In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion.
MEASUREMENTS AND MAIN RESULTS
After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmHO (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature.
CONCLUSIONS
Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength.
TRIAL REGISTRATION NUMBER
NCT05799352.
PubMed: 38914469
DOI: 10.1136/thorax-2024-221375 -
World Neurosurgery Jun 2024Various clinical classifications of craniopharyngiomas (CRPs) have been proposed to suggest optimal surgical planning. We aimed to evaluate the clinical outcomes of...
BACKGROUND
Various clinical classifications of craniopharyngiomas (CRPs) have been proposed to suggest optimal surgical planning. We aimed to evaluate the clinical outcomes of pediatric CRPs and the clinical significance of anatomical classification in relation to the diaphragm sellae.
METHODS
A retrospective review was conducted on patients under 18 years of age who underwent surgery for CRPs from July 1998 to August 2022. The patients were divided into transcranial approach (TCA), and transsphenoidal approach (TSA) groups, which included microscopic TSA and endoscopic endonasal approach (EEA) groups. EEA has been adopted at our institute since 2011. CRPs were classified by their origin and relationship with the diaphragm sellae.
RESULTS
A total of 132 pediatric CRP patients were included in this study, 117 of whom underwent surgery for primary CRP and 15 for recurrent CRP. Among them, 89 (67.4%) underwent TCA, 9 (6.8%) had microscopic TSA, and 34 (25.8%) had EEA. In subdiaphragmatic CRPs with competent diaphragm sellae, TSA tended to yield better outcomes than did TCA in terms of stalk preservation and ophthalmological outcomes. After the introduction of EEA, the proportion of supradiaphragmatic CRPs treated via the TSA increased from 0% to 50% (p < 0.001). Gross total resection (HR=0.194; 95% CI=0.102-0.367, p < 0.001) and adjuvant therapy (HR=0.208; 95% CI=0.048-0.897, p = 0.035) were found to be positive prognostic factors for long-term tumor control.
CONCLUSIONS
Over time, with the adoption of EEA at our institute, the impact of anatomical classification on the surgical apprpoach has decreased. Nevertheless, an individualized surgical approach should be employed to improve long-term outcomes and minimize complications for pediatric CRPs.
PubMed: 38914136
DOI: 10.1016/j.wneu.2024.06.106 -
PloS One 2024A diaphragm pump is a type of volumetric pump that has excellent sealing performance. An electromagnetic diaphragm pump is a kind of widely adopted diaphragm pump that...
A diaphragm pump is a type of volumetric pump that has excellent sealing performance. An electromagnetic diaphragm pump is a kind of widely adopted diaphragm pump that has a simple structure, low power loss, and high cost performance. However, the calculation method of deformation for the electromagnetic diaphragm pump rubber diaphragm is presently lacking. Herein, a calculating method of deformation for the electromagnetic diaphragm pump rubber diaphragm is proposed. By establishing and analyzing a deformation model of the electromagnetic diaphragm pump rubber diaphragm, a theoretical relationship between the deformation of the electromagnetic diaphragm pump rubber diaphragm, the size of the electromagnetic diaphragm pump rubber diaphragm and the pressure of fluid is determined. The experimental results indicate that the biggest difference between the tested axial deformation and the calculated axial deformation of the electromagnetic diaphragm pump rubber diaphragm is 0.04 mm and the calculation results show agreement with the experimental results.
Topics: Rubber; Electromagnetic Phenomena; Equipment Design; Models, Theoretical
PubMed: 38913628
DOI: 10.1371/journal.pone.0304052 -
Journal of Critical Care Jun 2024Diaphragm dysfunction is associated with weaning outcomes in mechanical ventilation patients, in the case of diaphragm dysfunction, the accessory respiratory muscles...
BACKGROUND
Diaphragm dysfunction is associated with weaning outcomes in mechanical ventilation patients, in the case of diaphragm dysfunction, the accessory respiratory muscles would be recruited. The main purpose of this study is to explore the performance of parasternal intercostal muscle thickening fraction in relation to diaphragmatic thickening fraction ratio (TFic/TFdi) for predicting weaning outcomes, and compare its accuracy with D-RSBI in predicting weaning failure.
MATERIALS AND METHODS
We prospectively enrolled consecutive patients from 7/2022-5/2023. We measured TFic, TFdi, and diaphragmatic excursion (DE) by ultrasound and calculated the TFic/TFdi ratio and diaphragmatic rapid shallow breathing index (D-RSBI). Receiver-operator characteristic (ROC) curves evaluated the accuracy of the TFic/TFdi ratio and D-RSBI in predicting weaning failure.
RESULTS
161 were included in the final analysis, 114 patients (70.8%) were successfully weaned from mechanical ventilation. The TFic/TFdi ratio (AUROC = 0.887 (95% CI: 0.821-0.953)) was superior to the D-RSBI (AUROC = 0.875 (95% CI: 0.807-0.944)) for predicting weaning failure.
CONCLUSIONS
The TFic/TFdi ratio predicted weaning failure with high accuracy and outperformed the D-RSBI.
PubMed: 38909540
DOI: 10.1016/j.jcrc.2024.154847