Scientific Reports Dec 2023Endoscopy training models (ETM) using artificial organs are practical, hygienic and comfortable for trainees. However, few models exist for training endoscopic...
Endoscopy training models (ETM) using artificial organs are practical, hygienic and comfortable for trainees. However, few models exist for training endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy. This training is necessary as the number of bariatric surgeries performed worldwide increases. ETM with human-like anatomy were developed to represent the postoperative anatomy after Billroth II (BII) reconstruction for a standard duodenoscope and the situs of a long-limbed Roux-en-Y (RY) for device-assisted enteroscopy (DAE). In three independent workshops, the models were evaluated by international ERCP experts. In RY model, a simulation for small bowel behavior in endoscopy was created. Thirty-three experts rated the ETM in ERCP expert courses. The BII model was evaluated as suitable for training (school grades 1.36), with a haptic and visual impression rating of 1.73. The RY model was rated 1.50 for training suitability and 2.06 for overall impression. Animal tissue-free ETMs for ERCP in surgically altered anatomy were successfully created. Evaluation by experienced endoscopists indicated that the models are suitable for hands-on ERCP training, including device-assisted endoscopy. It is expected that patient care will improve with appropriate training in advanced procedures.
Topics: Humans; Cholangiopancreatography, Endoscopic Retrograde; Intestine, Small; Endoscopy, Gastrointestinal; Anastomosis, Roux-en-Y; Artificial Organs; Retrospective Studies
PubMed: 38129520
DOI: 10.1038/s41598-023-49888-3 -
Infection Control and Hospital... Mar 2024
Topics: Humans; Duodenoscopes; Sterilization; Drug Resistance, Multiple, Bacterial; Cholangiopancreatography, Endoscopic Retrograde
PubMed: 37946384
DOI: 10.1017/ice.2023.246 -
Endoscopy International Open Sep 2023The costs of reusable endoscope reprocessing have been evaluated, yet external validity of the findings remains challenging. The aim of this study was to assess the...
The costs of reusable endoscope reprocessing have been evaluated, yet external validity of the findings remains challenging. The aim of this study was to assess the costs of purchase, maintenance, microbiological control, and reprocessing of a reusable duodenoscope per endoscopic retrograde cholangiopancreatography (ERCP) in France. Study findings exclude the costs of infection, downtime due to breakdown, reprocessing single-use material disposal, and device disposal, all of which should also be considered. The study encompassed both observational and theoretical approaches. Observational data were collected in four hospitals, from December 2019 to December 2020, with an ad hoc survey, based on 2016 and 2018 national guidelines for duodenoscope reprocessing. Costs were modeled, using the same guidelines, assuming a mean workload of 223 ERCP/duodenoscope/year. The mean observed cost of purchase, maintenance, microbiological control, reprocessing (human resources and consumables), and overhead (additional 35%) with a reusable duodenoscope was €80.23 (standard deviation €3.77) per ERCP. The corresponding mean theoretical cost was €182.71 for manual reprocessing without endoscope drying cabinet (EDC), €191.36 for manual reprocessing with EDC, €235.25 for automated endoscope reprocessing (AER) without EDC, and €253.62 for AER with EDC. Because procedures, equipment, volume activity, number of duodenoscopes, human resources, and internal work organizations are hospital-dependent, observed costs varied between hospitals. Theoretical costs were higher than observed costs, showing that the theoretical approach is not sufficient. Hypotheses to explain the difference between the two approaches include failing to measure some costs in the survey and challenges in guideline implementation.
PubMed: 37942444
DOI: 10.1055/a-2153-7016 -
The Korean Journal of Gastroenterology... Oct 2023Endoscopic retrograde cholangiopancreatography in a patient with achalasia and sigmoid esophagus poses a unique technical challenge, as one must safely guide the side...
Endoscopic retrograde cholangiopancreatography in a patient with achalasia and sigmoid esophagus poses a unique technical challenge, as one must safely guide the side viewing duodenoscope across a severely distorted distal esophagus and non-relaxing lower esophageal sphincter. In such patients, the use of an overtube is a simple solution that allows the safe passage of a duodenoscope and the removal of common bile duct stones.
Topics: Humans; Cholangiopancreatography, Endoscopic Retrograde; Esophageal Sphincter, Lower; Esophageal Achalasia; Duodenoscopes; Colon, Sigmoid
PubMed: 37876258
DOI: 10.4166/kjg.2023.078 -
Journal of Gastroenterology and... Jan 2024Gastrointestinal (GI) endoscopy is among the highest waste generator in healthcare facilities. The major reasons include production of large-volume non-renewable waste,... (Review)
Review
Gastrointestinal (GI) endoscopy is among the highest waste generator in healthcare facilities. The major reasons include production of large-volume non-renewable waste, use of single-use devices, and reprocessing or decontamination processes. Single-use endoscopic accessories have gradually replaced reusable devices over last two decades contributing to the rising impact of GI endoscopy on ecosystem. Several reports of infection outbreaks with reusable duodenoscopes raised concerns regarding the efficacy and adherence to standard disinfection protocols. Even the enhanced reprocessing techniques like double high-level disinfection have not been found to be the perfect ways for decontamination of duodenoscopes and therefore, paved the way for the development of single-use duodenoscopes. However, the use of single-use endoscopes is likely to amplify the net waste generated and carbon footprint of any endoscopy unit. Moreover, single-use devices challenge one of the major pillars of sustainability, that is, "reuse." In the era of climate change, a balanced approach is required taking into consideration patient safety as well as financial and environmental implications. The possible solutions to provide optimum care while addressing the impact on climate include selective use of disposable duodenoscopes and careful selection of accessories during a case. Other options include use of disposable endcaps and development of effective high-level disinfection techniques. The collaboration between the healthcare professionals and the manufacturers is paramount for the development of environmental friendly devices with low carbon footprint.
Topics: Humans; Climate Change; Ecosystem; Equipment Contamination; Endoscopes; Duodenoscopes; Disinfection; Endoscopy, Gastrointestinal
PubMed: 37859502
DOI: 10.1111/jgh.16380 -
Endoscopy Dec 2023
Topics: Humans; Duodenoscopes; Infection Control; Sterilization; Equipment Contamination; Disinfection; Cholangiopancreatography, Endoscopic Retrograde; Cross Infection
PubMed: 37852265
DOI: 10.1055/a-2175-3762 -
Endoscopy Mar 2024Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This...
BACKGROUND
Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes.
METHODS
This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention.
RESULTS
Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; =0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.
Topics: Humans; Duodenoscopes; Magnesium Oxide; Retrospective Studies; Disinfection; Equipment Contamination; Endoscopy, Gastrointestinal
PubMed: 37848074
DOI: 10.1055/a-2193-4481 -
American Journal of Infection Control Apr 2024Over the past decade, infections linked to duodenoscopes have become a significant concern, primarily due to the intricate design of the elevator mechanism. Currently,...
Over the past decade, infections linked to duodenoscopes have become a significant concern, primarily due to the intricate design of the elevator mechanism. Currently, there is limited evidence regarding the bacterial contamination level of the elevator mechanism after clinical use and throughout its various reprocessing stages. This study utilized the swab culture technique to examine the bacterial contamination on the duodenoscope elevator mechanism after clinical use and after 3 reprocessing stages at a Center of tertiary hospital. Our findings revealed severe bacterial contamination after clinical usage, emphasizing that the effectiveness of manual cleaning greatly influences the subsequent high-level disinfection quality.
Topics: Humans; Duodenoscopes; Equipment Contamination; Bacteria; Disinfection
PubMed: 37838249
DOI: 10.1016/j.ajic.2023.10.003 -
Journal of Hepato-biliary-pancreatic... Dec 2023Kawakami and colleagues report a case of duodenoscope insertion difficulty through the pyloric ring due to perigastric adhesions which was successfully overcome using an...
Kawakami and colleagues report a case of duodenoscope insertion difficulty through the pyloric ring due to perigastric adhesions which was successfully overcome using an overtube. The overtube can be attached to both standard and therapeutic duodenoscopes, allowing successful biliary or pancreatic intervention in patients in whom duodenoscopic insertion is challenging.
Topics: Humans; Cholangiopancreatography, Endoscopic Retrograde; Duodenoscopes; Pancreas
PubMed: 37792664
DOI: 10.1002/jhbp.1362 -
Ibrain 2023This study aimed to determine the values of the half-effective dose (ED) and 95% effective dose (ED) of remimazolam besylate used in the procedural sedation of...
This study aimed to determine the values of the half-effective dose (ED) and 95% effective dose (ED) of remimazolam besylate used in the procedural sedation of endoscopic retrograde cholangiopancreatography (ERCP). Sixty patients who fulfilled the inclusion and exclusion criteria of this study were selected. Sufentanil was administered intravenously and remimazolam besylate was administered 2 min later. ERCP treatment was feasible when the modified alertness/sedation (MOAA/S) score was ≤2. If choking or movement occurred during duodenoscope placement, it was considered as a positive reaction. The dose was increased in the next patient; otherwise, it was considered as a negative reaction, and the dose was reduced in the next patient. The ED and ED values and 95% confidence interval (CI) of remimazolam besylate were calculated by Probit regression analysis. All 60 patients completed the trial. The ED and ED values of remimazolam besylate were 0.196 and 0.239 mg/kg, respectively, for the procedural sedation of ERCP. The time of MOAA/S score ≤ 2 was (82.58 ± 21.70) s, and the mean time of awakening was (9.03 ± 5.64) min. Transient hypotension was observed in two patients without medical intervention. The ED and ED values of remimazolam besylate used in the procedural sedation of ERCP were 0.196 and 0.239 mg/kg, and the dose of the medications has definite efficacy and good safety.
PubMed: 37786755
DOI: 10.1002/ibra.12072