Journal of Plastic, Reconstructive &... Jun 2024Assessment of breast volume is essential in preoperative planning of immediate breast reconstruction (IBR) surgery to achieve satisfactory cosmetic outcome. This study...
BACKGROUND
Assessment of breast volume is essential in preoperative planning of immediate breast reconstruction (IBR) surgery to achieve satisfactory cosmetic outcome. This study introduced a breast volume measurement tool that can be used to perform automatic segmentation of magnetic resonance images (MRI) and calculation of breast volume. We compared the accuracy and reliability of this measurement method with four other conventional modalities.
METHODS
Patients who were scheduled to undergo mastectomy with IBR between 2016 and 2021 were enrolled in the study. Five different breast volume assessments, including automatic segmentation of MRI, manual segmentation of MRI, 3D surface imaging, mammography, and the BREAST-V formula, were used to evaluate different breast volumes. The results were validated using water displacement volumes of the mastectomy specimens.
RESULTS
In this pilot study, a total of 50 female patients met the inclusion criteria and contributed 54 breast specimens to the volumetric analysis. There was a strong linear association between the MRI and water displacement methods (automatic segmentation: r = 0.911, p < 0.001; manual segmentation: r = 0.924, p < 0.001), followed by 3D surface imaging (r = 0.858, p < 0.001), mammography (r = 0.841, p < 0.001), and Breast-V formula (r = 0.838, p < 0.001). Breast volumes measured using automatic and manual segmentation of MRI had lower mean relative errors (30.3% ± 22.0% and 28.9% ± 19.8, respectively) than 3D surface imaging (38.9% ± 31.2), Breast-V formula (44.8% ± 25.8), and mammography (60.3% ± 37.6).
CONCLUSION
Breast volume assessment using the MRI methods had better accuracy and reliability than the other methods used in our study. Breast volume measurement using automatic segmentation of MRI could be more efficient compared to the conventional methods.
PubMed: 38943699
DOI: 10.1016/j.bjps.2024.05.029 -
Journal of Breast Imaging Jun 2024To evaluate the effects of the Enhancing Quality Using the Inspection Program (EQUIP) on quality control (QC) and quality assurance (QA) at an academic medical center.
OBJECTIVES
To evaluate the effects of the Enhancing Quality Using the Inspection Program (EQUIP) on quality control (QC) and quality assurance (QA) at an academic medical center.
METHODS
EQUIP audit logs for technologist image quality review as well as mammography unit QA and QC formed the basis for study data. One randomly selected screening mammogram was evaluated by the lead interpreting physician (LIP) using EQUIP criteria for each technologist for each imaging site worked, initially semiannually and then monthly. One randomly selected screening mammogram interpreted by each interpreting physician (IP) for each imaging site was evaluated on a semiannual basis. Quarterly, the LIP reviewed QA and QC logs for each mammography unit with deficiencies further investigated.
RESULTS
Of 214 965 eligible screening mammograms performed, 5955 (2.8%) underwent EQUIP image quality review. Five were found to be technically inadequate (0.08%, 5955/214 965). The LIP identified 20 significant interpretive differences compared with the clinical interpretation resulting in 10 biopsies and 7 previously undetected malignancies, with supplemental cancer detection rate of 1.2/1000 cases reviewed. Two hundred ninety mammography unit QA/QC reviews identified 31 potential deficiencies, 29 of which were due to human documentation error (93.4%).
CONCLUSION
EQUIP review of both IP and technologists' quality and mammography unit QA/QC logs as performed identified few deficiencies. EQUIP policies should be evaluated at each institution and modified to best utilize resources and provide opportunities for meaningful quality improvement. Although not an EQUIP focus, supplemental cancer detection was observed as might be expected with double reading.
PubMed: 38943287
DOI: 10.1093/jbi/wbae034 -
Clinical Proteomics Jun 2024The development of breast cancer has been mainly reported in women who have reached the post-menopausal stage; therefore, it is the primary factor responsible for death... (Review)
Review
The development of breast cancer has been mainly reported in women who have reached the post-menopausal stage; therefore, it is the primary factor responsible for death amongst postmenopausal women. However, if treated on time it has shown a survival rate of 20 years in about two-thirds of women. Cases of breast cancer have also been reported in younger women and the leading cause in them is their lifestyle pattern or they may be carriers of high penetrance mutated genes. Premenopausal women who have breast cancer have been diagnosed with aggressive build-up of tumors and are therefore at more risk of loss of life. Mammography is an effective way to test for breast cancer in women after menopause but is not so effective for premenopausal women or younger females. Imaging techniques like contrast-enhanced MRI can up to some extent indicate the presence of a tumor but it cannot adequately differentiate between benign and malignant tumors. Although the 'omics' strategies continuing for the last 20 years have been helpful at the molecular level in enabling the characteristics and proper understanding of such tumors over long-term longitudinal monitoring. Classification, diagnosis, and prediction of the outcomes have been made through tissue and serum biomarkers but these also fail to diagnose the disease at an early stage. Considerably there is no adequate detection technique present globally that can help early detection and provide adequate specificity, safety, sensitivity, and convenience for the younger and premenopausal women, thereby it becomes necessary to take early measures and build efficient tools and techniques for the same. Through biopsies of nipple aspirate fluid (NAF) biomarker profiling can be performed. It is a naturally secreted fluid from the cells of epithelium found in the breast. Nowadays, home-based liquid biopsy collection kits are also available through which a routine check on breast health can be performed with the help of NAF. Herein, we will review the biomarker screening liquid biopsy, and the new emerging technologies for the examination of cancer at an early stage, especially in premenopausal women.
PubMed: 38943056
DOI: 10.1186/s12014-024-09495-4 -
Korean Journal of Radiology Jul 2024Evaluating the performance of a binary diagnostic test, including artificial intelligence classification algorithms, involves measuring sensitivity, specificity,... (Review)
Review
Evaluating the performance of a binary diagnostic test, including artificial intelligence classification algorithms, involves measuring sensitivity, specificity, positive predictive value, and negative predictive value. Particularly when comparing the performance of two diagnostic tests applied on the same set of patients, these metrics are crucial for identifying the more accurate test. However, comparing predictive values presents statistical challenges because their denominators depend on the test outcomes, unlike the comparison of sensitivities and specificities. This paper reviews existing methods for comparing predictive values and proposes using the permutation test. The permutation test is an intuitive, non-parametric method suitable for datasets with small sample sizes. We demonstrate each method using a dataset from MRI and combined modality of mammography and ultrasound in diagnosing breast cancer.
Topics: Humans; Breast Neoplasms; Female; Predictive Value of Tests; Magnetic Resonance Imaging; Mammography; Sensitivity and Specificity; Algorithms; Ultrasonography, Mammary
PubMed: 38942459
DOI: 10.3348/kjr.2024.0049 -
Korean Journal of Radiology Jul 2024In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known...
OBJECTIVE
In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR).
MATERIALS AND METHODS
An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs.
RESULTS
Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs.
CONCLUSION
The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.
Topics: Humans; Republic of Korea; Artificial Intelligence; Surveys and Questionnaires; Societies, Medical; Radiology; Software
PubMed: 38942455
DOI: 10.3348/kjr.2023.1246 -
British Journal of Hospital Medicine... Jun 2024Breast leukaemia (BL) is a rare breast malignancy that is treated differently from other malignant conditions. However, it is easily confused with other conditions;...
Breast leukaemia (BL) is a rare breast malignancy that is treated differently from other malignant conditions. However, it is easily confused with other conditions; therefore, how to accurately diagnose is crucial. We retrospectively analysed the imaging findings of 13 patients to provide a diagnostic reference. From January 2015 to April 2023, 13 patients with BL confirmed by biopsy who underwent imaging in Peking University People's hospital were retrospectively analysed. The imaging findings obtained via ultrasound (US), mammography (MMG), magnetic resonance imaging (MRI), and positron emission tomography/computed tomography (PET/CT) were analysed, and the detection rates of these methods for diagnosing BL were compared. Twenty-nine lesions were detected in the 13 patients. These patients presented with palpable masses or breast swelling several months after treatment for leukaemia, mainly involving the bilateral breasts. Ultrasonography was performed for 13 patients, and all lesions were detected. Most of the identified masses were hypoechoic and had indistinct boundaries, irregular shapes, no enhancement of the posterior echo, and no abundant blood flow. MMG was performed for five patients, revealing breast masses, architectural distortion, and no abnormalities. MRI was performed for four patients, and all lesions were detected; most of the lesions were hypointense on T1-weighted imaging and hyperintense on T2-weighted imaging and diffusion-weighted imaging, with a decreased apparent diffusion coefficient and inhomogeneous enhancement. The enhancement curves were mostly inflow patterns. PET/CT was performed for four patients; two patients had hypermetabolism, and the other two had no obvious radioactive uptake. Compared to MMG and PET/CT, US and MRI have higher detection rates. Furthermore, compared to MRI, US is inexpensive, convenient and efficient; therefore, it should be the first choice for diagnosing BL.
Topics: Humans; Female; Breast Neoplasms; Middle Aged; Adult; Retrospective Studies; Positron Emission Tomography Computed Tomography; Magnetic Resonance Imaging; Mammography; Ultrasonography, Mammary; Leukemia; Aged
PubMed: 38941971
DOI: 10.12968/hmed.2024.0101 -
European Radiology Jul 2024
Topics: Humans; Breast Neoplasms; Female; Early Detection of Cancer; Diffusion Magnetic Resonance Imaging; Breast Density; Contrast Media; Mammography; Ultrasonography, Mammary; Precision Medicine; Breast
PubMed: 38940855
DOI: 10.1007/s00330-023-10323-w -
Radiology. Imaging Cancer Jul 2024
Topics: Humans; Mammography; Female; Breast Neoplasms; Radiographic Image Enhancement; Early Detection of Cancer
PubMed: 38940690
DOI: 10.1148/rycan.249014 -
Polish Journal of Radiology 2024Breast lesions that remain elusive in traditional imaging techniques such as ultrasound and mammography pose a diagnostic challenge. In such cases, magnetic resonance...
PURPOSE
Breast lesions that remain elusive in traditional imaging techniques such as ultrasound and mammography pose a diagnostic challenge. In such cases, magnetic resonance (MR)-guided breast biopsy emerges as a crucial tool for accurate histopathological verification. This article presents a comparative study conducted at 2 centres, exploring the results of MR-guided breast biopsies performed by experienced radiologists, based on inside and external referrals.
MATERIAL AND METHODS
The study involved 228 patients, 120 of whom underwent biopsies at Centre 1, where the same radiologist performed both the qualification and biopsy. The remaining 108 patients were biopsied at Centre 2, based on referrals from different institutions. Uniform examination protocols were adopted at both centres, and all biopsies underwent histopathological verification.
RESULTS
The distribution of lesion types was found to be independent of the apparatus used for biopsies ( = 0.759). Interestingly, Centre 1 exhibited a higher prevalence of infiltrating carcinomas compared to Centre 2 ( = 0.12). Furthermore, the analysis demonstrated a significant variance in the nature of the lesions in relation to breast structure and biopsy centre ( < 0.001).
CONCLUSIONS
MR-guided breast biopsy serves as a remarkable tool for verifying lesions that evade detection through conventional imaging methods and physical examinations. The study findings underscore the crucial role of radiologist experience in determining the efficacy of MR-guided breast biopsies.
PubMed: 38938661
DOI: 10.5114/pjr/186862 -
Polish Journal of Radiology 2024To assess the effectiveness of contrast-enhanced mammography (CEM) recombinant images in detecting malignant lesions in patients with extremely dense breasts compared to...
Comparison of the effectiveness of contrast-enhanced mammography in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.
PURPOSE
To assess the effectiveness of contrast-enhanced mammography (CEM) recombinant images in detecting malignant lesions in patients with extremely dense breasts compared to the all-densities population.
MATERIAL AND METHODS
792 patients with 808 breast lesions, in whom the final decision on core-needle biopsy was made based on CEM, and who received the result of histopathological examination, were qualified for a single-centre, retrospective study. Patient electronic records and imaging examinations were reviewed to establish demographics, clinical and imaging findings, and histopathology results. The CEM images were reassessed and assigned to the appropriate American College of Radiology (ACR) density categories.
RESULTS
Extremely dense breasts were present in 86 (10.9%) patients. Histopathological examination confirmed the presence of malignant lesions in 52.6% of cases in the entire group of patients and 43% in the group of extremely dense breasts. CEM incorrectly classified the lesion as false negative in 16/425 (3.8%) cases for the whole group, and in 1/37 (2.7%) cases for extremely dense breasts. The sensitivity of CEM for the group of all patients was 96.2%, specificity - 60%, positive predictive values (PPV) - 72.8%, and negative predictive values (NPV) - 93.5%. In the group of patients with extremely dense breasts, the sensitivity of the method was 97.3%, specificity - 59.2%, PPV - 64.3%, and NPV - 96.7%.
CONCLUSIONS
CEM is characterised by high sensitivity and NPV in detecting malignant lesions regardless of the type of breast density. In patients with extremely dense breasts, CEM could serve as a complementary or additional examination in the absence or low availability of MRI.
PubMed: 38938658
DOI: 10.5114/pjr/186180