BioImpacts : BI 2024A new analytical method based on the coupling of microextraction and microfluidics was developed and investigated for the pre-concentration, separation, and...
INTRODUCTION
A new analytical method based on the coupling of microextraction and microfluidics was developed and investigated for the pre-concentration, separation, and electrochemical detection of fenitrothion (FT) and parathion (PA) at the sub-ppm concentrations.
METHODS
In the first step, the microchip capillary electrophoresis technique was used to serve as a separation and detection system. Analytes were injected in the 40 mm long microchannel with 10 mm sidearms. Then, they were separated by applying a direct electrical field (+1800 V) between the buffer and detection reservoirs. 2-(n-morpholino)ethanesulfonic acid (MES) buffer (20 mM, pH 5) was used as a running buffer. The electrochemical detection was performed using three Pt microelectrodes with the width of working, counter, and reference electrodes (50, 250, and 250 µm, respectively) in the out-channel approach.
RESULTS
The system was devised to have the optimum detection potential equal to -1.2 V vs. pseudo-reference electrode. The dimensions of the SU-8 channel have 20 µm depth and 50 µm width. In the second step, an air-assisted liquid-liquid microextraction technique was used to extract and preconcentration of analytes from human blood plasma. Then, 1, 2 di-bromoethan was used as extractant solvent, the analytes were preconcentrated, and the sedimented solvent (50 µL) was evaporated in a 60 ˚C water bath followed by substitution of running buffer containing 10% ethanol. The optimal extraction cycles were found to be 8 with adding 1% NaCl to the aqueous phase. Analyzing time of the mentioned analytes was less than 100s, the precision range was 3.3 - 8.2 with a linear range of 0.8-100 ppm and 1.2-100 ppm for FT and PA, respectively. The extraction recoveries were about 91% and 87% for FT and PA, respectively. The detection limits for FT and PA were 240 and 360 ppb, respectively. Finally, the reliability of the method was investigated by GC-FID.
CONCLUSION
The proposed method and device were validated and can be used as in situ and portable detection systems for detecting fenitrothion and parathion insecticides.
PubMed: 38938753
DOI: 10.34172/bi.2023.25288 -
Stereotactic and Functional Neurosurgery Jun 2024We present our surgical complications resulting in neurological deficit or additional surgery during 25 years of DBS of the subthalamic nucleus (STN) for Parkinson's...
INTRODUCTION
We present our surgical complications resulting in neurological deficit or additional surgery during 25 years of DBS of the subthalamic nucleus (STN) for Parkinson's disease (PD).
METHODS
We conducted a retrospective chart review of all PD patients that received STN DBS in our DBS center between 1998 and 2023. Outcomes were complications resulting in neurological deficit or additional surgery. Potential risk factors (number of microelectrode recording tracks, age, anesthesia method, hypertension, and sex) for symptomatic intracerebral hemorrhage (ICH) were analyzed. Furthermore, lead fixation techniques were compared.
RESULTS
Eight hundred PD patients (507 men, 293 women) received unilateral (n = 11) or bilateral (n = 789) implantation of STN electrodes. Neurological deficit due to ICH, edema, delirium, or infarction was seen in 8.4% of the patients (7.4% transient, 1.0% permanent). Twenty-two patients (2.8%) had a symptomatic ICH following STN DBS, for which we did not find any risk factors, and five had permanent sequelae due to ICH (0.6%). Of all patients, 18.4% required additional surgery; the proportion was reduced from 27% in the first 300 cases to 13% in the last 500 cases (p < 0.001). The infection rate was 3.5%, which decreased from 5.3% in the first 300 cases to 2.2% in the last 500 cases. The use of a lead anchoring device led to significantly less lead migrations than miniplate fixation.
CONCLUSION
STN DBS leads to permanent neurological deficit in a small number of patients (1.0%), but a substantial proportion needs some additional surgical procedure after the first DBS system implantation. The risk of revision surgery was reduced over time but remained significant. These findings need to be discussed with the patient in the preoperative informed consent process in addition to the expected health benefit.
PubMed: 38934196
DOI: 10.1159/000539483 -
Stereotactic and Functional Neurosurgery Jun 2024The aim of this study was to present a novel technique for subthalamic nucleus (STN) deep brain stimulation (DBS) implantation under general anesthesia by using...
Mapping of Capsular Side Effects by using Intraoperative Motor-Evoked Potentials during Asleep Deep Brain Stimulation Surgery of the Subthalamic Nucleus for Parkinson's Disease.
INTRODUCTION
The aim of this study was to present a novel technique for subthalamic nucleus (STN) deep brain stimulation (DBS) implantation under general anesthesia by using intraoperative motor-evoked potentials (MEPs) through direct lead stimulation and determining their correlation to the thresholds of postoperative stimulation-induced side effects.
METHODS
This study included 22 consecutive patients with advanced Parkinson's disease who underwent surgery in our institution between January 2021 and September 2023. All patients underwent bilateral implantation in the STN (44 leads) under general anesthesia without microelectrode recordings (MERs) by using MEPs with electrostimulation directly through the DBS lead. No cortical stimulation was performed during this process. Intraoperative fluoroscopic guidance and immediate postoperative computed tomography were used to verify the electrode's position. The lowest MEP thresholds were recorded and were correlated to the postoperative stimulation-induced side-effect threshold. The predictive values of the MEPs were analyzed. Five DBS leads were repositioned intraoperatively due to the MEP results.
RESULTS
A moderately strong positive correlation was found between the MEP threshold and the capsular side-effect threshold (RS = 0.425, 95% CI, 0.17-0.67, p = 0.004). The highest sensitivity and specificity for predicting a side-effect threshold of 5 mA were found to be at 2.4 mA MEP threshold (sensitivity 97%, specificity 87.5%, positive predictive value 97%, and negative predictive value 87.5%). We also found high sensitivity and specificity (100%) at 1.15 mA MEP threshold and 3 mA side-effect threshold. Out of the total 44 leads, 5 (11.3%) leads were repositioned intraoperatively due to MEP thresholds lower than 1 mA (4 leads) or higher than 5 mA (1 lead). The mean accuracy on postoperative CT was 1.05 mm, and there were no postoperative side-effects under 2.8 mA.
CONCLUSION
Intraoperative MEPs with electrostimulation directly through the contacts of the DBS lead correlate with the stimulation-induced capsular side effects. The lead reposition based on intraoperative MEP may enlarge the therapeutic window of DBS stimulation.
PubMed: 38934180
DOI: 10.1159/000539433 -
Micromachines Jun 2024This paper demonstrates the potential of anisotropic 3D printing for alignable carbon nanomaterials. The ferrite-decorated nanocarbon material was synthesized via a...
This paper demonstrates the potential of anisotropic 3D printing for alignable carbon nanomaterials. The ferrite-decorated nanocarbon material was synthesized via a sodium solvation process using epichlorohydrin as the coupling agent. Employing a one-pot synthesis approach, the novel material was incorporated into a 3D photopolymer, manipulated, and printed using a low-cost microscale 3D printer, equipped with digital micromirror lithography, monitoring optics, and magnetic actuators. This technique highlights the ability to control the microstructure of 3D-printed objects with sub-micron precision for applications such as microelectrode sensors and microrobot fabrication.
PubMed: 38930733
DOI: 10.3390/mi15060763 -
Micromachines May 2024Arsenic contamination poses a significant public health risk worldwide, with chronic exposure leading to various health issues. Detecting and monitoring arsenic exposure...
Arsenic contamination poses a significant public health risk worldwide, with chronic exposure leading to various health issues. Detecting and monitoring arsenic exposure accurately remains challenging, necessitating the development of sensitive detection methods. In this study, we introduce a novel approach using fast-scan cyclic voltammetry (FSCV) coupled with carbon-fiber microelectrodes (CFMs) for the electrochemical detection of As. Through an in-depth pH study using tris buffer, we optimized the electrochemical parameters for both acidic and basic media. Our sensor demonstrated high selectivity, distinguishing the As signal from those of As and other potential interferents under ambient conditions. We achieved a limit of detection (LOD) of 0.5 μM (37.46 ppb) and a sensitivity of 2.292 nA/μM for bare CFMs. Microscopic data confirmed the sensor's stability at lower, physiologically relevant concentrations. Additionally, using our previously reported double-bore CFMs, we simultaneously detected As-Cu and As-Cd in tris buffer, enhancing the LOD of As to 0.2 μM (14.98 ppb). To our knowledge, this is the first study to use CFMs for the rapid and selective detection of As via FSCV. Our sensor's ability to distinguish As from As in a physiologically relevant pH environment showcases its potential for future in vivo studies.
PubMed: 38930703
DOI: 10.3390/mi15060733 -
Micromachines May 2024Modern microtechnology methods are widely used to create neural networks on a chip with a connection architecture demonstrating properties of modularity and hierarchy...
Modern microtechnology methods are widely used to create neural networks on a chip with a connection architecture demonstrating properties of modularity and hierarchy similar to brain networks. Such in vitro networks serve as a valuable model for studying the interplay of functional architecture within modules, their activity, and the effectiveness of inter-module interaction. In this study, we use a two-chamber microfluidic platform to investigate functional connectivity and global activity in hierarchically connected modular neural networks. We found that the strength of functional connections within the module and the profile of network spontaneous activity determine the effectiveness of inter-modular interaction and integration activity in the network. The direction of intermodular activity propagation configures the different densities of inhibitory synapses in the network. The developed microfluidic platform holds the potential to explore function-structure relationships and efficient information processing in two- or multilayer neural networks, in both healthy and pathological states.
PubMed: 38930702
DOI: 10.3390/mi15060732 -
Brain Sciences Jun 2024Cerebral intraparenchymal hemorrhage due to electrode implantation (CIPHEI) is a rare but serious complication of deep brain stimulation (DBS) surgery. This study...
Cerebral Intraparenchymal Hemorrhage due to Implantation of Electrodes for Deep Brain Stimulation: Insights from a Large Single-Center Retrospective Cross-Sectional Analysis.
Cerebral intraparenchymal hemorrhage due to electrode implantation (CIPHEI) is a rare but serious complication of deep brain stimulation (DBS) surgery. This study retrospectively investigated a large single-center cohort of DBS implantations to calculate the frequency of CIPHEI and identify patient- and procedure-related risk factors for CIPHEI and their potential interactions. We analyzed all DBS implantations between January 2013 and December 2021 in a generalized linear model for binomial responses using bias reduction to account for sparse sampling of CIPHEIs. As potential risk factors, we considered age, gender, history of arterial hypertension, level of invasivity, types of micro/macroelectrodes, and implanted DBS electrodes. If available, postoperative coagulation and platelet function were exploratorily assessed in CIPHEI patients. We identified 17 CIPHEI cases across 839 electrode implantations in 435 included procedures in 418 patients (3.9%). Exploration and cross-validation analyses revealed that the three-way interaction of older age (above 60 years), high invasivity (i.e., use of combined micro/macroelectrodes), and implantation of directional DBS electrodes accounted for 82.4% of the CIPHEI cases. Acquired platelet dysfunction was present only in one CIPHEI case. The findings at our center suggested implantation of directional DBS electrodes as a new potential risk factor, while known risks of older age and high invasivity were confirmed. However, CIPHEI risk is not driven by the three factors alone but by their combined presence. The contributions of the three factors to CIPHEI are hence not independent, suggesting that potentially modifiable procedural risks should be carefully evaluated when planning DBS surgery in patients at risk.
PubMed: 38928612
DOI: 10.3390/brainsci14060612 -
BMC Neuroscience Jun 2024Astrocytes are the most abundant cell type of the central nervous system and are fundamentally involved in homeostasis, neuroprotection, and synaptic plasticity. This...
BACKGROUND
Astrocytes are the most abundant cell type of the central nervous system and are fundamentally involved in homeostasis, neuroprotection, and synaptic plasticity. This regulatory function of astrocytes on their neighboring cells in the healthy brain is subject of current research. In the ischemic brain we assume disease specific differences in astrocytic acting. The renin-angiotensin-aldosterone system regulates arterial blood pressure through endothelial cells and perivascular musculature. Moreover, astrocytes express angiotensin II type 1 and 2 receptors. However, their role in astrocytic function has not yet been fully elucidated. We hypothesized that the angiotensin II receptors impact astrocyte function as revealed in an in vitro system mimicking cerebral ischemia. Astrocytes derived from neonatal wistar rats were exposed to telmisartan (angiotensin II type 1 receptor-blocker) or PD123319 (angiotensin II type 2 receptor-blocker) under normal conditions (control) or deprivation from oxygen and glucose. Conditioned medium (CM) of astrocytes was harvested to elucidate astrocyte-mediated indirect effects on microglia and cortical neurons.
RESULT
The blockade of angiotensin II type 1 receptor by telmisartan increased the survival of astrocytes during ischemic conditions in vitro without affecting their proliferation rate or disturbing their expression of S100A10, a marker of activation. The inhibition of the angiotensin II type 2 receptor pathway by PD123319 resulted in both increased expression of S100A10 and proliferation rate. The CM of telmisartan-treated astrocytes reduced the expression of pro-inflammatory mediators with simultaneous increase of anti-inflammatory markers in microglia. Increased neuronal activity was observed after treatment of neurons with CM of telmisartan- as well as PD123319-stimulated astrocytes.
CONCLUSION
Data show that angiotensin II receptors have functional relevance for astrocytes that differs in healthy and ischemic conditions and effects surrounding microglia and neuronal activity via secretory signals. Above that, this work emphasizes the strong interference of the different cells in the CNS and that targeting astrocytes might serve as a therapeutic strategy to influence the acting of glia-neuronal network in de- and regenerative context.
Topics: Animals; Astrocytes; Rats, Wistar; Microglia; Receptor, Angiotensin, Type 2; Telmisartan; Angiotensin II Type 1 Receptor Blockers; Neurons; Receptor, Angiotensin, Type 1; Ischemic Stroke; Angiotensin II Type 2 Receptor Blockers; Rats; Cells, Cultured; Pyridines; Imidazoles; Animals, Newborn; Benzimidazoles; Cell Communication
PubMed: 38926677
DOI: 10.1186/s12868-024-00876-x -
Angewandte Chemie (International Ed. in... Jun 2024For the anodic H2O2 generation, it has been shown that the electrolyte composition can steer the reaction pathway toward increased H2O2 generation. Previous efforts made...
For the anodic H2O2 generation, it has been shown that the electrolyte composition can steer the reaction pathway toward increased H2O2 generation. Previous efforts made on composition optimization found that the impact of the molar fraction of carbonate species varies for different anodes, and therefore, controversies remain concerning the reaction pathways as well as the species involved in H2O2 formation. Considering that water oxidation results in the liberation of protons within the anode microenvironment, the corresponding acidification would cause an equilibrium shift between carbonate species, which in turn may modulate the reaction pathway. We determined the changes in the fraction of carbonate species in the vicinity of an anode by performing local pH measurements using a Au nanoelectrode positioned in close proximity to an operating anode by shear-force scanning electrochemical microscopy (SECM). It could be confirmed that the main anionic species at the interface is HCO3-, at potentials where H2O2 is preferentially formed, regardless of the pH value in the bulk. The simultaneous use of a Au-Pt double barrel microelectrode in generator-collector SECM measurements demon-strates that the local HCO3- concentration is collectively determined by the oxidation current, buffer capacity, and bulk pH of the electrolyte.
PubMed: 38923335
DOI: 10.1002/anie.202406543 -
Biosensors Jun 2024Development and optimisation of bioelectronic monitoring techniques like microelectrode array-based field potential measurement and impedance spectroscopy for the...
Development and optimisation of bioelectronic monitoring techniques like microelectrode array-based field potential measurement and impedance spectroscopy for the functional, label-free and non-invasive monitoring of in vitro neuronal networks is widely investigated in the field of biosensors. Thus, these techniques were individually used to demonstrate the capabilities of, e.g., detecting compound-induced toxicity in neuronal culture models. In contrast, extended application for investigating the effects of central nervous system infecting viruses are rarely described. In this context, we wanted to analyse the effect of herpesviruses on functional neuronal networks. Therefore, we developed a unique hybrid bioelectronic monitoring platform that allows for performing field potential monitoring and impedance spectroscopy on the same microelectrode. In the first step, a neuronal culture model based on primary hippocampal cells from neonatal rats was established with reproducible and stable synchronised electrophysiological network activity after 21 days of cultivation on microelectrode arrays. For a proof of concept, the pseudorabies model virus PrV Kaplan-ΔgG-GFP was applied and the effect on the neuronal networks was monitored by impedance spectroscopy and field potential measurement for 72 h in a multiparametric mode. Analysis of several bioelectronic parameters revealed a virus concentration-dependent degeneration of the neuronal network within 24-48 h, with a significant early change in electrophysiological activity, subsequently leading to a loss of activity and network synchronicity. In conclusion, we successfully developed a microelectrode array-based hybrid bioelectronic measurement platform for quantitative monitoring of pathologic effects of a herpesvirus on electrophysiological active neuronal networks.
Topics: Animals; Rats; Biosensing Techniques; Neurons; Dielectric Spectroscopy; Nerve Net; Microelectrodes; Hippocampus; Herpesvirus 1, Suid; Cells, Cultured; Pseudorabies
PubMed: 38920600
DOI: 10.3390/bios14060295