-
Acta Veterinaria Scandinavica Mar 2024Piglets are born with limited stores of iron, and with an increasing number of live-born piglets, there may be a risk that the sows cannot provide enough iron to their...
BACKGROUND
Piglets are born with limited stores of iron, and with an increasing number of live-born piglets, there may be a risk that the sows cannot provide enough iron to their offspring. The iron content in soil may not meet the demands of today's piglet, born and reared in an outdoor setting. The study aimed to describe the blood haemoglobin (Hb) levels in pigs reared outdoors and to determine whether piglets have higher Hb levels at weaning when an iron supplement is administered intramuscularly at three days of age, as compared to pigs not given an iron supplement. The seasonal variation in Hb-levels was also to be investigated. The Hb concentration was analysed with a HemoCue 201 + Hb photometer.
RESULTS
In total 56 litters (399 piglets) were included in the study and sampled at three days of age, while 378 piglets were sampled at weaning. The mean Hb level at three days of age was 91 g/L (48-154 g/L). In total 47% of the piglets had Hb levels < 90 g/L at three days of age. The mean Hb level at weaning was 127 g/L (76-176 g/L), with a lower level (122 g/L) in the group given the iron supplement than in the group not given an iron supplement (132 g/L). Only 1% of the piglets had Hb levels lower than 90 g/L at weaning. Results indicative of a seasonal effect on Hb levels at three days of age was demonstrated. Piglets born in spring had significantly lower Hb levels, and piglets born in autumn had significantly higher Hb levels. No seasonal effect could be demonstrated for Hb levels at day 33.
CONCLUSIONS
The results indicate that the natural uptake from the environment was sufficient, but that there was a seasonal effect on the Hb levels at three days of age. This indicates that there might be a need for different routines regarding iron supplementation in outdoor reared piglets depending on the climate and season.
Topics: Animals; Swine; Female; Iron; Weaning; Seasons; Farms; Sweden; Hemoglobins; Lactation
PubMed: 38504355
DOI: 10.1186/s13028-024-00735-z -
Environment International Mar 2024A reliable determination of equivalent black carbon (eBC) mass concentrations derived from filter absorption photometers (FAPs) measurements depends on the appropriate...
A reliable determination of equivalent black carbon (eBC) mass concentrations derived from filter absorption photometers (FAPs) measurements depends on the appropriate quantification of the mass absorption cross-section (MAC) for converting the absorption coefficient (b) to eBC. This study investigates the spatial-temporal variability of the MAC obtained from simultaneous elemental carbon (EC) and b measurements performed at 22 sites. We compared different methodologies for retrieving eBC integrating different options for calculating MAC including: locally derived, median value calculated from 22 sites, and site-specific rolling MAC. The eBC concentrations that underwent correction using these methods were identified as LeBC (local MAC), MeBC (median MAC), and ReBC (Rolling MAC) respectively. Pronounced differences (up to more than 50 %) were observed between eBC as directly provided by FAPs (NeBC; Nominal instrumental MAC) and ReBC due to the differences observed between the experimental and nominal MAC values. The median MAC was 7.8 ± 3.4 m g from 12 aethalometers at 880 nm, and 10.6 ± 4.7 m g from 10 MAAPs at 637 nm. The experimental MAC showed significant site and seasonal dependencies, with heterogeneous patterns between summer and winter in different regions. In addition, long-term trend analysis revealed statistically significant (s.s.) decreasing trends in EC. Interestingly, we showed that the corresponding corrected eBC trends are not independent of the way eBC is calculated due to the variability of MAC. NeBC and EC decreasing trends were consistent at sites with no significant trend in experimental MAC. Conversely, where MAC showed s.s. trend, the NeBC and EC trends were not consistent while ReBC concentration followed the same pattern as EC. These results underscore the importance of accounting for MAC variations when deriving eBC measurements from FAPs and emphasize the necessity of incorporating EC observations to constrain the uncertainty associated with eBC.
Topics: Air Pollutants; Environmental Monitoring; Aerosols; Seasons; Soot; Carbon; Particulate Matter
PubMed: 38460240
DOI: 10.1016/j.envint.2024.108553 -
Frontiers in Physiology 2024Exposure of experimental rodents to controlled cycles of light, food, and temperature is important when investigating alterations in circadian cycles that profoundly...
Exposure of experimental rodents to controlled cycles of light, food, and temperature is important when investigating alterations in circadian cycles that profoundly influence health and disease. However, applying such stimuli simultaneously is difficult in practice. We aimed to design, build, test, and open-source describe a simple device that subjects a conventional mouse cage to independent cycles of physiologically relevant environmental variables. The device is based on a box enclosing the rodent cage to modify the light, feeding, and temperature environments. The device provides temperature-controlled air conditioning (heating or cooling) by a Peltier module and includes programmable feeding and illumination. All functions are set by a user-friendly front panel for independent cycle programming. Bench testing with a model simulating the CO production of mice in the cage showed: a) suitable air renewal (by measuring actual ambient CO), b) controlled realistic illumination at the mouse enclosure (measured by a photometer), c) stable temperature control, and d) correct cycling of light, feeding, and temperature. The cost of all the supplies (retail purchased by e-commerce) was <300 US$. Detailed technical information is open-source provided, allowing for any user to reliably reproduce or modify the device. This approach can considerably facilitate circadian research since using one of the described low-cost devices for any mouse group with a given light-food-temperature paradigm allows for all the experiments to be performed simultaneously, thereby requiring no changes in the light/temperature of a general-use laboratory.
PubMed: 38434139
DOI: 10.3389/fphys.2024.1356787 -
Khirurgiia 2024To justify the optimal method for determining indocyanine green plasma disappearance rate (PDR).
OBJECTIVE
To justify the optimal method for determining indocyanine green plasma disappearance rate (PDR).
MATERIAL AND METHODS
We analyzed PDR in intensive care units. Indocyanine green was administered intravenously at a dose of 0.25 mg/kg. PDR was analyzed simultaneously by using of three methods: 1) PDD (PiCCO2 LiMON device), 2) SBS with analysis of plasma samples on precise spectrophotometer, 3) SBS with analysis of plasma samples on simple experimental photometer.
RESULTS
PDD method was used for 346 PDR tests in 256 patients. Of these, 14.3% of measurements were erroneous. Paired tests using PDD and SBS methods were performed in 299 cases. SBS method resulted erroneous data in 0.6% of cases. Certain correlation (=0.79, <0.001) was found between the reference method (SBS with spectrophotometry) and the PDD method. Bland-Altman plot for these two methods showed that proportional bias of mean difference was caused by extremely high PDR of the PDD method (for example, more than 30%/min). Comparison of two SBS variants (spectrophotometer and experimental photometer) revealed good correlation (=0.91, <0.001).
CONCLUSION
SBS method for measuring PDR ensures accurate results under mechanical interferences in patients with impaired capillary blood flow. This eliminates the need for redo measurement. Duplication of the PDD and SBS methods is recommended when repeating the test is not possible (organ donors).
Topics: Humans; Indocyanine Green; Coloring Agents; Densitometry; Hemodynamics; Intensive Care Units
PubMed: 38380459
DOI: 10.17116/hirurgia20240225 -
Environmental Science & Technology Mar 2024Nitrous acid (HONO) is an important source of hydroxyl radicals (OH) in the atmosphere. Precise determination of the absolute ultraviolet (UV) absorption cross section...
Nitrous acid (HONO) is an important source of hydroxyl radicals (OH) in the atmosphere. Precise determination of the absolute ultraviolet (UV) absorption cross section of gaseous HONO lays the basis for the accurate measurement of its concentration by optical methods and the estimation of HONO loss rate through photolysis. In this study, we performed a series of laboratory and field intercomparison experiments for HONO measurement between striping coil-liquid waveguide capillary cell (SC-LWCC) photometry and incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS). Specified HONO concentrations prepared by an ultrapure standard HONO source were utilized for laboratory intercomparisons. Results show a consistent ∼22% negative bias in measurements of the IBBCEAS compared with a SC-LWCC photometer. It is confirmed that the discrepancies occurring between these techniques are associated with the overestimation of the absolute UV absorption cross sections through careful analysis of possible uncertainties. We quantified the absorption cross section of gaseous HONO (360-390 nm) utilizing a custom-built IBBCEAS instrument, and the results were found to be 22-34% lower than the previously published absorption cross sections widely used in HONO concentration retrieval and atmospheric chemical transport models (CTMs). This suggests that the HONO concentrations retrieved by optical methods based on absolute absorption cross sections may have been underestimated by over 20%. Plus, the daytime loss rate and unidentified sources of HONO may also have evidently been overestimated in pre-existing studies. In summary, our findings underscore the significance of revisiting the absolute absorption cross section of HONO and the re-evaluation of the previously reported HONO budgets.
Topics: Nitrous Acid; Gases; Air Pollutants; Spectrum Analysis; Photolysis
PubMed: 38373403
DOI: 10.1021/acs.est.3c08339 -
Heliyon Feb 2024The Upper Awash sub-basin characterized by urban, industrial, agricultural and population growth, has impacted the quality of its water sources. This study focuses on...
The Upper Awash sub-basin characterized by urban, industrial, agricultural and population growth, has impacted the quality of its water sources. This study focuses on the assessment of public health risks associated with drinking water sources in the sub-basin. In accordance with WHO guidelines, 120 water samples were collected from 60 water supply schemes in dry and wet seasons located in areas with low and high water pollution risk (WPR). Multi-meter, Photometer, Digital Arsenator, and Microbiological test kit measured the concentration of parameters. The assessment uses methods of hazard identification, exposure and dose-response analysis, and risk characterization, including Hazard Quotient (HQ), Cancer Risk (CR), Hazard Index (HI), and probability of infection. Monte Carlo simulation analyzes non-cancer risks from Nitrite, Nitrate, Chromium, Iron, Fluoride, and Arsenic, and CRs from Chromium and Arsenic, and infection risks from (). As a result, the Hazard Quotient (HQ) of Nitrate was beyond unity (HQ > 1) in the dry season for all groups. HQ of Chromium was HQ > 1 for Women (1.1E+00) and Children (1.4E+00) in the wet season in the high WPR area. Chromium HQ > 1 for children (1.4E+00) in the wet season and Fluoride (HQ > 1) for Children (3.2E+00) in the dry season in the low WPR area. Arsenic CR was above 1 in 10,000 persons for children in the dry season, for all groups, and for women and children in the wet season in the high WPR areas. The CR of chromium ranged from 1 in 1000 persons, which is beyond the limit. Moreover, the Hazard Index (HI) was higher than the unity (HI > 1) for most cases. All infection risks daily and annually exceeded the acceptable risks. Therefore, Public health concerns in the Sub-basin were quantified, and evidences were generated for risk management to undertake source protection through integrated watershed management and appropriate water treatment technologies.
PubMed: 38314286
DOI: 10.1016/j.heliyon.2024.e24790 -
Pediatric Rheumatology Online Journal Jan 2024Juvenile Idiopathic Arthritis (JIA) Associated Uveitis (JIA-U) remains one of the most serious complications of JIA in children. Historically, pediatric JIA is diagnosed... (Observational Study)
Observational Study
BACKGROUND
Juvenile Idiopathic Arthritis (JIA) Associated Uveitis (JIA-U) remains one of the most serious complications of JIA in children. Historically, pediatric JIA is diagnosed by an Optometrist or Ophthalmologist; however, barriers to scheduling increase wait times that may delay diagnosis and treatment. The purpose of this study was to evaluate laser flare photometry (LFP) use to diagnose JIA-U in the Pediatric Rheumatology clinic for patients with JIA.
METHODS
This prospective, observational study assessed pediatric patients diagnosed with JIA without a previous history of uveitis between January 2020 and September 2022. All patients underwent at least one evaluation of both eyes using a Kowa FM-600 laser flare photometer during a routine Rheumatology appointment, as well as a standard slit lamp examination (SLE) by optometry or ophthalmology during routine clinical care. Data collected at patient visits included demographics, JIA characteristics, treatment, LFP readings, and anterior chamber (AC) cell grade score utilizing the SUN grading system. Data were summarized using descriptive analyses and the uveitis false positive rate was calculated.
RESULTS
The study cohort included 58 pediatric patients diagnosed with JIA. The mean age was 8.4 years (1.2-16.3 years) at diagnosis and 11.9 (4.8-16.5 years) at enrollment. The mean duration of disease at time of enrollment was 42 months (range; 0-157 months). Participants were predominantly female (n = 43, 74.1%) and white/Caucasian race (n = 37, 63.8%). The most common JIA subtypes included persistent oligoarticular JIA (n = 19, 32.8%), and RF negative polyarticular JIA (n = 12, 20.7%). There were 12 ANA positive patients (20.7%). At enrollment, 16 patients (27.6%) were not on medications, with 20 (34.5%) on methotrexate, 20 (34.5%) on adalimumab, 6 (10.3%) on tocilizumab, and 5 (8.6%) on etanercept. During the study period, no eye exams detected active uveitis based on SLE with a SUN grade over 0. However, of the 135 LFP readings, 131 (97.0%) were normal, yielding a false positive rate of 3% (95% CI: 0.8%, 7.4%).
CONCLUSIONS
LFP is a non-invasive tool that can be utilized in the pediatric rheumatology clinic to evaluate for JIA-U. There is a low false positive rate of LFP when compared with standard slit lamp exam.
Topics: Humans; Child; Female; Male; Arthritis, Juvenile; Prospective Studies; Rheumatology; Uveitis; Photometry; Lasers
PubMed: 38279120
DOI: 10.1186/s12969-024-00961-9 -
Sensors (Basel, Switzerland) Jan 2024Aerosols play a crucial role in the surface radiative budget by absorbing and scattering both shortwave and longwave radiation. While most aerosol types exhibit a...
Aerosols play a crucial role in the surface radiative budget by absorbing and scattering both shortwave and longwave radiation. While most aerosol types exhibit a relatively minor longwave radiative forcing when compared to their shortwave counterparts, dust aerosols stand out for their substantial longwave radiative forcing. In this study, radiometers, a sun photometer, a microwave radiometer and the parameterization scheme for clear-sky radiation estimation were integrated to investigate the radiative properties of aerosols. During an event in Xianghe, North China Plain, from 25 April to 27 April 2018, both the composition (anthropogenic aerosol and dust) and the aerosol optical depth (AOD, ranging from 0.3 to 1.5) changed considerably. A notable shortwave aerosol radiative effect (SARE) was revealed by the integrated system (reaching its peak at -131.27 W·m on 26 April 2018), which was primarily attributed to a reduction in direct irradiance caused by anthropogenic aerosols. The SARE became relatively consistent over the three days as the AODs approached similar levels. Conversely, the longwave aerosol radiative effect (LARE) on the dust days ranged from 8.94 to 32.93 W·m, significantly surpassing the values measured during the days of anthropogenic aerosol pollution, which ranged from 0.35 to 28.67 W·m, despite lower AOD values. The LARE increased with a higher AOD and a lower Ångström exponent (AE), with a lower AE having a more pronounced impact on the LARE than a higher AOD. It was estimated that, on a daily basis, the LARE will offset approximately 25% of the SARE during dust events and during periods of heavy anthropogenic pollution.
PubMed: 38257489
DOI: 10.3390/s24020397 -
International Journal of Molecular... Jan 2024Mass photometry (MP) is a fast and simple analysis method for the determination of the proportions of subpopulations in an AAV sample. It is label-free and requires...
Mass photometry (MP) is a fast and simple analysis method for the determination of the proportions of subpopulations in an AAV sample. It is label-free and requires minimal sample volumes between 5-10 µL, which makes it a promising candidate over orthogonal techniques such as analytical ultracentrifugation (AUC), cryo-transmission electron microscopy (Cryo-TEM) or charge-detection mass spectrometry (CDMS). However, these methods are limited in their application to purified samples only. Here we developed a purification step based on single-domain monospecific antibody fragments immobilised on either a poly(styrene-divinylbenzene) resin or on magnetic beads prior to MP analysis that allows the quantification of empty, partially filled, full and overfull AAV vectors in crude cell extracts. This is aimed at identifying potentially promising harvest conditions that yield large numbers of filled AAV vectors during the early stages of the viral vector development platform, e.g., the type of transfection reagent used. Furthermore, we provide a direct comparison of the automated and manual handling of the mass photometer with respect to the quantities of AAV subspecies, molar mass of the capsid and payload, and highlight the differences between the "buffer-free" sample measurement and the "buffer-dilution" mode. In addition, we provide information on which candidates to use for calibration and demonstrate the limitations of the mass photometer with respect to the estimation of the capsid titer.
Topics: Cell Extracts; Dependovirus; Biotechnology; Calibration; Capsid Proteins; Photometry; Single-Domain Antibodies
PubMed: 38255912
DOI: 10.3390/ijms25020838 -
Animals : An Open Access Journal From... Dec 2023The objective of the present study was to determine the effects that the reproductive season has on the motility, kinematics, morphology, and sperm morphometry of...
The objective of the present study was to determine the effects that the reproductive season has on the motility, kinematics, morphology, and sperm morphometry of Brahman bulls evaluated with a commercial CASA system. The experiment was carried out at the Costa Rica Institute of Technology from March to August 2021. A total of eight Brahman bulls were used. A total of 28 ejaculates were collected in the pre-mating period (PMP), during it (DMP), and after it (AMP) using an electroejaculator. The sperm concentration was measured with the Accuread photometer. The motility was measured using a Spermtrack counting chamber. The analyses were performed with the CASA-Mot ISASv1 system. The morphology was analyzed using a microscope with a negative phase contrast objective. Morphometry was evaluated with the CASA-Morph. The sperm concentration did not present differences between the PMP and AMP; however, it was significantly higher than DMP ( > 0.05). Regarding the progressiveness variables, linearity on forward progression (LIN), straightness (STR), and wobble (WOB) were higher ( < 0.05) DMP. A kinematic principal component analysis grouped all the variables into three factors and an effect on the reproductive period was found ( < 0.05) in the parameters of the head and middle part of the sperm, such as width and perimeter, which were greater in the PMP. The length of the sperm head in the PMP and DMP did not show differences; however, both were larger ( < 0.05) than AMP. The insertion distance of the middle piece of the sperm was significantly greater than DMP. Finally, the PMP contained cells with a larger insertion angle ( < 0.05) than AMP. These findings are important to understand the implications of reproductive status on sperm quality and to consider them in andrological evaluations.
PubMed: 38200863
DOI: 10.3390/ani14010132