Scientific Reports Mar 2024How the human eye focuses for near; i.e. accommodates, is still being evaluated after more than 165 years. The mechanism of accommodation is essential for understanding...
How the human eye focuses for near; i.e. accommodates, is still being evaluated after more than 165 years. The mechanism of accommodation is essential for understanding the etiology and potential treatments for myopia, glaucoma and presbyopia. Presbyopia affects 100% of the population in the fifth decade of life. The lens is encased in a semi-elastic capsule with attached ligaments called zonules that mediate ciliary muscle forces to alter lens shape. The zonules are attached at the lens capsule equator. The fundamental issue is whether during accommodation all the zonules relax causing the central and peripheral lens surfaces to steepen, or the equatorial zonules are under increased tension while the anterior and posterior zonules relax causing the lens surface to peripherally flatten and centrally steepen while maintaining lens stability. Here we show with a balloon capsule zonular force model that increased equatorial zonular tension with relaxation of the anterior and posterior zonules replicates the topographical changes observed during in vivo rhesus and human accommodation of the lens capsule without lens stroma. The zonular forces required to simulate lens capsule configuration during in vivo accommodation are inconsistent with the general belief that all the zonules relax during accommodation.
Topics: Animals; Humans; Presbyopia; Lens Capsule, Crystalline; Accommodation, Ocular; Lens, Crystalline; Macaca mulatta
PubMed: 38467700
DOI: 10.1038/s41598-024-56563-8 -
Current Opinion in Ophthalmology Jan 2024This review aims to clarify the advantages and disadvantages of immediately sequential bilateral cataract surgery (ISBCS) based on recent studies, illustrate the safety... (Review)
Review
PURPOSE OF REVIEW
This review aims to clarify the advantages and disadvantages of immediately sequential bilateral cataract surgery (ISBCS) based on recent studies, illustrate the safety of this approach, the cost-effectiveness, and present the importance of inclusion protocols for the best results.
RECENT FINDINGS
In recent studies, the authors found no evidence of an increased risk of bilateral devastating complications such as endophthalmitis with ISBCS based on descriptive evidence compared to delayed sequential bilateral cataract surgery (DSBCS). Furthermore, recent studies on cost analyses showed that ISBCS resulted in fewer costs and significant cost savings to third-party payers, patients, and society compared to DSBCS.
SUMMARY
The ISBCS surgical approach decreases hospital visits, reduces costs, and provides rapid visual rehabilitation and neuro adaptation. The risk of bilateral simultaneous complications is now recognized to be very rare with intracameral antibiotics and compliance with correct protocols. With new generations of optical biometry and lens calculation formulas, refractive surprises are occasional for normal eyes. However, refractive surprise is controversial, especially in the implantation of presbyopia correction intra-ocular lenses, which must be evaluated carefully in the ISBCS approach.
Topics: Humans; Phacoemulsification; Lens Implantation, Intraocular; Cataract Extraction; Visual Acuity; Cataract
PubMed: 38390776
DOI: 10.1097/ICU.0000000000001003 -
Cureus Jan 2024Background Presbyopia is a physiological condition arising due to the loss of accommodation within the crystalline lens. One of the most widely accepted theories of the...
Background Presbyopia is a physiological condition arising due to the loss of accommodation within the crystalline lens. One of the most widely accepted theories of the mechanism of accommodation was that in response to ciliary muscle contraction, the crystalline lens thickness increases, the lens diameter decreases, and both the anterior and posterior curvature of the lens increase, resulting in an increase in lenticular power therefore, accommodation. A contrasting theory suggests that ciliary muscle contraction leads to a selective increase in equatorial zonular tension, with the lens equator moving toward the sclera and the equatorial diameter of the lens increasing. This results in a change of lens optical power. Until now, clinical approaches to correct presbyopia have included monovision, multifocality, and extended depth of focus, all three of which can be achieved surgically on the cornea or by lens surgery. Methods This was a cross-sectional study adopted among patients who had Presbyond surgery in Taif City, Saudi Arabia, and were aged 40 years and older. The data was collected by conducting phone interviews to increase the response rate with a prepared questionnaire that was studied to achieve equality between participants to determine whether they were satisfied or not about the results after this surgery. The contact information was retrieved based on hospital records about patients who underwent Presbyond surgery. Data was analyzed using IBM SPSS Statistics for Windows, Version 22 (Released 2013; IBM Corp., Armonk, New York, United States). The data was collected for the period beginning on the first of January 2019 until the first of February 2023. Results From the study findings, a significant number of participants (28.1%, n=25) reported experiencing complete improvement and returning to normal life within 1-30 days after surgery. A slightly larger percentage (39.2%, n=35) experienced this within 1-3 months. Most of the participants (80.9%, n=72) reported an overall improvement in their quality of life after the surgery. This included activities such as reading and using a mobile phone. This indicates that the surgery had a positive impact on their daily lives and activities. In terms of recommendations, a total of 49 (55.1%, n=49) participants stated that they were very likely to recommend refractive surgery to a family member or friend experiencing vision problems. The study found that the mean patients' satisfaction score after one month of surgery is 2.494 units higher than the mean satisfaction score before surgery. This difference was statistically significant (p < .001). Conclusion The majority of participants did not experience any problems during the surgery, and most were able to resume their normal activities within a relatively brief period of time. The surgery achieved its goals for the majority of participants, resulting in an improvement in their quality of life. However, some short-term discomfort or adjustment period was reported. Overall, the participants were satisfied with the surgery, with the majority being very likely to recommend it to others. There is room for improvement in addressing concerns such as blurred vision, the need for glasses, and dry eyes. The study also found that patient satisfaction increased significantly after one month of surgery, and the timing of complete improvement and perception of achieving surgical goals were strongly associated with perceived outcomes.
PubMed: 38389611
DOI: 10.7759/cureus.52776 -
Optometry and Vision Science : Official... Jan 2024A variety of subjective and objective procedures are available to measure the amplitude of accommodation. However, it is unclear whether the standard criterion of...
SIGNIFICANCE
A variety of subjective and objective procedures are available to measure the amplitude of accommodation. However, it is unclear whether the standard criterion of Hofstetter's minimum minus 2 D can be used to diagnose accommodative insufficiency with each of these techniques.
PURPOSE
The use of objective dynamic retinoscopy and three subjective techniques to diagnosis accommodative insufficiency was examined.
METHODS
A total of 632 subjects between 8 and 19 years of age were enrolled. Accommodative lag, monocular accommodative facility, and subjective (push-up, modified push-down, and minus lens) and objective (dynamic retinoscopy) amplitude of accommodation were quantified. Accommodative insufficiency was diagnosed based on Hofstetter's minimum minus 2 D for each subjective method, as well as adding an additional subjective criterion (either accommodative lag exceeding 0.75 D or monocular accommodative facility falling below the age-expected norms).
RESULTS
The prevalence of accommodative insufficiency was lowest and highest with the push-up (7.9 and 1%) and dynamic retinoscopy (94 and 12%) procedures when measured without and with the additional subjective criteria, respectively. Comparing the validity of dynamic retinoscopy against the traditional criterion, moderate to low sensitivity and high specificity were found. However, adding the additional subjective criteria improved the findings with moderate to high sensitivity and high specificity. Using a cutoff for dynamic retinoscopy of 7.50 D showed moderate diagnostic accuracy based on likelihood ratios.
CONCLUSIONS
It is clear that a revised definition of accommodative insufficiency is required, which must include the method of assessing accommodation. The various objective and subjective methods for quantifying the amplitude of accommodation are not interchangeable, and subjective assessment does not provide a valid measure of the accommodative response.
Topics: Humans; Refraction, Ocular; Visual Acuity; Accommodation, Ocular; Retinoscopy; Lens, Crystalline; Presbyopia
PubMed: 38350057
DOI: 10.1097/OPX.0000000000002097 -
Optometry and Vision Science : Official... Jan 2024Detailed clinical assessment is critical to allow sensitive evaluation of the eye and its management. As technology advances, these assessment techniques can be adapted...
Detailed clinical assessment is critical to allow sensitive evaluation of the eye and its management. As technology advances, these assessment techniques can be adapted and refined to improve the detection of pathological changes of ocular tissue and their impact on visual function. Enhancements in optical medical devices including spectacle, contact, and intraocular lenses have allowed for a better understanding of the mechanism and amelioration of presbyopia and myopia control. Advancements in imaging technology have enabled improved quantification of the tear film and ocular surface, informing diagnosis and treatment strategies. Miniaturized electronics, large processing power, and in-built sensors in smartphones and tablets capacitate more portable assessment tools for clinicians, facilitate self-monitoring and treatment compliance, and aid communication with patients. This article gives an overview of how technology has been used in many areas of eye care to improve assessments and treatment and provides a snapshot of some of my studies validating and using technology to inform better evidence-based patient management.
Topics: Humans; Vision, Ocular; Lenses, Intraocular; Presbyopia; Refractive Surgical Procedures; Awards and Prizes
PubMed: 38350054
DOI: 10.1097/OPX.0000000000002102 -
International Ophthalmology Feb 2024To compare the visual performance of two presbyopia-correcting intraocular lenses (IOLs) that combine both bifocal and extended depth-of-focus profiles, Artis®...
OBJECTIVE
To compare the visual performance of two presbyopia-correcting intraocular lenses (IOLs) that combine both bifocal and extended depth-of-focus profiles, Artis® Symbiose® Plus (Symbiose Plus; Cristalens Industrie, Lannion, France) and Tecnis® Synergy® (Synergy; Johnson & Johnson Vision, Santa Ana, CA, USA).
METHODS
The medical records of patients with cataract bilaterally implanted with either Symbiose Plus or Synergy between January 2022 and January 2023 were assessed. The principal measures of postoperative findings included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near (40 and 33 cm) visual acuity (UNVA), objective optical quality (OOQ) parameters, distance-corrected defocus curve analysis, and surveys of subjective satisfaction.
RESULTS
Total of 96 eyes from 48 patients were enrolled. Each group was equally composed of 24 patients, 48 eyes. There were no significant differences between the two groups on baseline characteristics. Both IOLs displayed excellent binocular UDVA, CDVA, and UNVA (40 and 33 cm) with no statistical difference (p = 0.467(UDVA), p = 0.584(CDVA), p = 0.096(40-cm UNVA), and p = 0.621(33-cm UNVA)). However, with regard to UIVA, the Synergy group showed significantly superior results (p < 0.001). In contrast, the Symbiose Plus group showed significantly better results on OOQ parameters and patient-reported quality of vision survey outcomes (both p < 0.001).
CONCLUSIONS
Both IOLs provided a decent continuous range of vision from near to far distance.
Topics: Humans; Refraction, Ocular; Lens Implantation, Intraocular; Presbyopia; Patient Satisfaction; Lenses, Intraocular; Prosthesis Design; Phacoemulsification; Vision, Binocular
PubMed: 38341384
DOI: 10.1007/s10792-024-02979-0 -
Journal of Patient-reported Outcomes Feb 2024Presbyopia is an age-related condition that causes a decreased ability to focus on nearby objects. Multifocal contact lenses are commonly used to address this issue....
BACKGROUND
Presbyopia is an age-related condition that causes a decreased ability to focus on nearby objects. Multifocal contact lenses are commonly used to address this issue. However, there seems to be a notable dissatisfaction among multifocal contact lens wearers. The absence of a reliable instrument to measure the patient's perspective, despite the widespread use of this method, highlights the need for further research in this area.
OBJECTIVE
The objective of this study is to develop an item-bank integrating all domains necessary to assess the patient's perspective on multifocal contact lens performance, offering a comprehensive measure. The item-bank will ensure a high level of content validity, be self-administered, and will initially be available in Spanish. The aim of this tool is to serve as a valuable resource for research and optometric clinics, facilitating the follow-up of patients with presbyopia who wear multifocal contact lenses or those who are newly starting to use them.
METHODOLOGY
The MCL-PRO item bank, followed a systematic and step-wise inductive approach to gather information, following the recommendations outlined in the COSMIN guidelines and similar studies. The process involved the following steps: (1) Literature review and relevant existing items identification (2) Social media review, (3) Semi-structured focus groups, (4) performing qualitative analysis, (5) refining and revising the items, and (6) generating the content of the item bank.
RESULTS
A total of 575 items were included in the item-bank hosted under 8 different domains that were found to be important for presbyopic population: visual symptoms (213), activity limitation (111), ocular symptoms (135), convenience (36), emotional well-being (33), general symptoms (16), cognitive issues (21) and economic issues (10).
CONCLUSION
The item-bank created has followed standardised methodology for its development and encloses all the aspects for MCL performance evaluation from patients perspective.
Topics: Humans; Presbyopia; Contact Lenses; Vision, Ocular; Focus Groups; Eye
PubMed: 38329635
DOI: 10.1186/s41687-024-00689-w -
Journal of Cataract and Refractive... Jun 2024To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology...
PURPOSE
To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL).
SETTING
2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States.
DESIGN
Prospective, unmasked, multicenter, nonrandomized bilateral eye study.
METHODS
Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function.
RESULTS
Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to -2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were "completely" or "mostly" satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as "excellent" or "good" by 92% (34/37) of participants.
CONCLUSIONS
This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.
Topics: Humans; Prospective Studies; Visual Acuity; Lens Implantation, Intraocular; Presbyopia; Vision, Binocular; Male; Female; Middle Aged; Aged; Refraction, Ocular; Phacoemulsification; Pseudophakia; Patient Satisfaction; Lenses, Intraocular; Surveys and Questionnaires; Multifocal Intraocular Lenses; Dominance, Ocular; Depth Perception; Prosthesis Design
PubMed: 38305420
DOI: 10.1097/j.jcrs.0000000000001412 -
Indian Journal of Ophthalmology Feb 2024To assess the photic phenomena (PP) and positive dysphotopsia in candidates for presbyopia or cataract surgery and to evaluate their relationship with cataract grading...
PURPOSE
To assess the photic phenomena (PP) and positive dysphotopsia in candidates for presbyopia or cataract surgery and to evaluate their relationship with cataract grading systems.
DESIGN
Retrospective observational.
METHODS
Monocular data for 82 subjects measured during the preoperative screening were retrospectively retrieved from our database. The evaluated variables consisted of two methods for PP measurement: light distortion index (LDI) and parameters obtained from a simulator, both of which were combined with subjective bother related to PP. The cutoff for LDI that better predicted patients passing from slightly to moderately bothersome was estimated. The relationships between LDI and the following objective cataract grading methods were also assessed: objective scatter index (OSI), dysfunctional lens index (DLI), and Pentacam Nucleus Staging (PNS).
RESULTS
LDI was the best method for measuring PP, which showed a significant correlation with the bothersome question (rho = 0.34, P = 0.002) and also with OSI (rho = 0.67, P < 0.0005), DLI (rho = -0.29, P = 0.007), and PNS (rho = 0.48, P < 0.0005). The number/percentage of patients who found it bothersome was as follows: "Not at all" (18/22%), "Slightly" (41/50%), "Moderately" (15/18.3%), and "Very" (8/9.7%). The cutoff value that predicted the transition from slightly to moderately bothersome was ≥15.20% according to LDI, which could be estimated with the following values for grading: ≥2.8 for OSI, ≤7.6 for DLI, and ≥2 for PNS.
CONCLUSIONS
Patients reporting moderately or higher bothersome levels in the preoperative period and with LDI <15.20%, <2.8 for OSI, >7.6 for DLI, and <2 for PNS might deserve special attention in the multifocal intraocular lens selection.
Topics: Humans; Multifocal Intraocular Lenses; Visual Acuity; Retrospective Studies; Lens Implantation, Intraocular; Prospective Studies; Cataract; Vision Disorders; Lenses, Intraocular; Phacoemulsification
PubMed: 38271416
DOI: 10.4103/IJO.IJO_1038_23 -
Eye (London, England) Jan 2024Recent estimates of global prevalence of uncorrected presbyopia range from 510 to 826 million. There is a shortage of primary data regarding Near Visual Impairment (NVI)...
BACKGROUND
Recent estimates of global prevalence of uncorrected presbyopia range from 510 to 826 million. There is a shortage of primary data regarding Near Visual Impairment (NVI) magnitude.
METHODS
Near visual acuity (NVA) and NVI data was collected from over 388,000 people aged 35 or over across 9 countries, within Community Eye Health programmes between January 2022 and June 2023. In Kenya (n = 34,328), dioptric power of required near correction was also recorded, and any association with age, gender or level of NVA was assessed via linear regression model.
RESULTS
146,801 of 388,939 people failed initial near vision screening (37.74%, 95% CI 37.59-37.89%), with significantly higher prevalence of NVI in Sub-Saharan Africa than South Asia. Of those with distance acuity 6/12 or better, 27.97% failed (95% CI 27.81-28.13%) with evidence of difference between genders (p < 0.001): 30.77% of women vs. 24.47% of men. The most commonly required dioptric powers of correction were +2.00D, +2.50D and +3.00D, and required power correlated with age and NVA.
CONCLUSIONS
NVI remains common among Community Eye Health programme participants aged 35 and over. Data from large scale programmes such as these provide an opportunity to contribute to more accurate epidemiological estimates, and to guide future research, resource planning and intervention, ideally with improved standardisation of testing in the future.
PubMed: 38253866
DOI: 10.1038/s41433-023-02910-4