-
Policy Insights From the Behavioral and... Mar 2024Sensory systems continuously recalibrate their responses according to the current stimulus environment. As a result, perception is strongly affected by the current and...
Sensory systems continuously recalibrate their responses according to the current stimulus environment. As a result, perception is strongly affected by the current and recent context. These adaptative changes affect both sensitivity (e.g., habituating to noise, seeing better in the dark) and appearance (e.g. how things look, what catches attention) and adjust to many perceptual properties (e.g. from light level to the characteristics of someone's face). They therefore have a profound effect on most perceptual experiences, and on how and how well the senses work in different settings. Characterizing the properties of adaptation, how it manifests, and when it influences perception in modern environments can provide . Adaptation could also be (e.g. in visual inspection tasks like radiology) and to (e.g. exposure to potentially unhealthy stimulus environments).
PubMed: 38933347
DOI: 10.1177/23727322231220494 -
Sensors (Basel, Switzerland) Jun 2024Color reintegration is a restoration treatment that involves applying paint or colored plaster to an object of cultural heritage to facilitate its perception and...
Color reintegration is a restoration treatment that involves applying paint or colored plaster to an object of cultural heritage to facilitate its perception and understanding. This study examines the impact of lighting on the visual appearance of one such restored piece: a tiled skirting panel from the Nasrid period (1238-1492), permanently on display at the Museum of the Alhambra (Spain). Spectral images in the range of 380-1080 nm were obtained using a hyperspectral image scanner. CIELAB and CIEDE2000 color coordinates at each pixel were computed assuming the CIE 1931 standard colorimetric observer and considering ten relevant illuminants proposed by the International Commission on Illumination (CIE): D65 plus nine white LEDs. Four main hues (blue, green, yellow, and black) can be distinguished in the original and reintegrated areas. For each hue, mean color difference from the mean (MCDM), CIEDE2000 average distances, volumes, and overlapping volumes were computed in the CIELAB space by comparing the original and the reintegrated zones. The study reveals noticeable average color differences between the original and reintegrated areas within tiles: 6.0 and 4.7 CIEDE2000 units for the yellow and blue tiles (with MCDM values of 3.7 and 4.5 and 5.8 and 7.2, respectively), and 16.6 and 17.8 CIEDE2000 units for the black and green tiles (with MCDM values of 13.2 and 12.2 and 10.9 and 11.3, respectively). The overlapping volume of CIELAB clouds of points corresponding to the original and reintegrated areas ranges from 35% to 50%, indicating that these areas would be perceived as different by observers with normal color vision for all four tiles. However, average color differences between the original and reintegrated areas changed with the tested illuminants by less than 2.6 CIEDE2000 units. Our current methodology provides useful quantitative results for evaluation of the color appearance of a reintegrated area under different light sources, helping curators and museum professionals to choose optimal lighting.
PubMed: 38931656
DOI: 10.3390/s24123872 -
Journal of Clinical Medicine Jun 2024Hydrotherapy, including the use of therapeutic showers and bathtubs, has been studied for its potential benefits in labor pain management. Previous research has...
Hydrotherapy, including the use of therapeutic showers and bathtubs, has been studied for its potential benefits in labor pain management. Previous research has indicated that hydrotherapy can alleviate pain, but comparative studies between therapeutic showers and bathtubs are scarce. : This study aims to compare the effects of therapeutic showers and bathtubs on pain perception, labor duration, use of epidural analgesia, and maternal and neonatal outcomes during labor. : A total of 124 pregnant women were included in this study. Participants were divided into two groups: those who used a therapeutic shower and those who used a bathtub during labor. Pain levels were measured using a visual analog scale (VAS). Labor duration, use of epidural analgesia, types of delivery, maternal outcomes (postpartum hemorrhage, perineal status, maternal hypotension, fever, and breastfeeding), and neonatal outcomes (APGAR scores, fetal heart rate, complications, and neonatal unit admissions) were recorded and analyzed. : Both the therapeutic shower and the bathtub effectively reduced pain perception, with the bathtub showing a greater reduction in VAS scores. The therapeutic shower group experienced a significantly shorter labor duration compared to the bathtub group. The majority of participants in both groups did not require epidural analgesia, with no significant differences between the groups. There were no significant differences in the types of delivery. Maternal outcomes indicated a lower incidence of perineal tears and episiotomies in the therapeutic shower group. Neonatal outcomes, including APGAR scores and fetal heart rate, were similar between the groups, with no significant differences in complications or neonatal unit admissions. : Both therapeutic showers and bathtubs are effective for pain relief during labor, with the bathtub showing a higher reduction in pain intensity. The therapeutic shower is associated with a shorter labor duration and a lower incidence of perineal tears and episiotomies. Both methods are safe for neonatal well-being, making hydrotherapy a viable non-pharmacological option for pain management in labor. However, the therapeutic shower may offer additional benefits in terms of labor duration and maternal outcomes.
PubMed: 38930046
DOI: 10.3390/jcm13123517 -
Journal of Personalized Medicine May 2024Transcranial direct current stimulation (tDCS) is emerging as a promising non-invasive intervention for tinnitus by aiming to modulate abnormal brain activity. This...
Transcranial direct current stimulation (tDCS) is emerging as a promising non-invasive intervention for tinnitus by aiming to modulate abnormal brain activity. This study investigated the efficacy of dual-session tDCS for the relief of perception, distress, and loudness in patients with severe chronic subjective tinnitus and assessed the duration of tinnitus suppression effects compared to single-session and control groups over a 2-month follow-up. In a prospective, randomized, single-blind, placebo-controlled trial, 30 participants with severe chronic subjective tinnitus underwent bifrontal tDCS. The control group (n = 9), single-session group (n = 10), and dual-session group (n = 11) received 2 mA stimulation for 20 min per session, twice a week for one month. The treatment response was monitored weekly using the Visual Analogue Scale (VAS), with additional assessments using the Tinnitus Handicap Inventory (THI) and Beck Depression Inventory (BDI) at the fourth and eighth weeks. The single- and dual-session groups showed statistically significant improvements in VAS, THI, and BDI scores compared to the control group. THI and BDI scores showed a significant difference between the single- and dual-session groups. The dual-session group demonstrated a more sustained tinnitus suppression effect than the single-session group. tDCS has been validated as an effective intervention for the suppression of tinnitus, with the dual-session protocol showing longer-term benefits. These findings support the potential of tDCS as a treatment for tinnitus, particularly in dual-session applications.
PubMed: 38929798
DOI: 10.3390/jpm14060577 -
Medicina (Kaunas, Lithuania) Jun 2024Platinum-based combination chemotherapy, including cisplatin and carboplatin, are important cytotoxic anti-cancer agents that are widely used to treat various solid...
Platinum-based combination chemotherapy, including cisplatin and carboplatin, are important cytotoxic anti-cancer agents that are widely used to treat various solid tumors. Carboplatin has a similar effect on survival in small cell lung cancer, but generally has a milder toxicity profile when compared with cisplatin. Both may cause moderate or severe neurotoxicity, but ocular neurotoxicity from carboplatin is rarely reported. A 79-year-old man underwent intravenous polychemotherapy (atezolizumab, etoposide, and carboplatin) for small cell lung cancer. One week after the second cycle of chemotherapy, he reported bilateral visual loss as hand motion in both eyes. Dilated fundus examination showed retinal arterial narrowing without hemorrhage, and diffuse choroidal and retinal thinning was observed in an optical coherence tomography scan. Fluorescein angiography revealed significantly delayed circulation without evidence of obstructive lesions. 30-Flicker electroretinogram testing showed a complete absence of cone response in both eyes. The patient's visual acuity aggravated to no light perception in both eyes, even after the cessation of chemotherapy. Carboplatin combination chemotherapy administered at therapeutic doses can result in irreversible visual loss, a side effect that is not widely acknowledged. When using carboplatin, physicians should be aware of its potential ocular toxicity.
Topics: Humans; Carboplatin; Male; Aged; Lung Neoplasms; Small Cell Lung Carcinoma; Antineoplastic Combined Chemotherapy Protocols; Vision Disorders; Antineoplastic Agents
PubMed: 38929609
DOI: 10.3390/medicina60060992 -
Medicina (Kaunas, Lithuania) May 2024Different techniques for artificial iris implantation with or without an intraocular lens, depending on lens status, are described in the literature. We describe a...
Different techniques for artificial iris implantation with or without an intraocular lens, depending on lens status, are described in the literature. We describe a surgical technique for a custom-made artificial iris and toric-intraocular lens intrascleral flange fixation. We modified the "Backpack" artificial iris implantation surgical technique to facilitate an accurate alignment of the toric-intraocular lens in a patient with aphakia, aniridia, and high asymmetric astigmatism secondary to blunt trauma. Two months after the surgery, uncorrected visual acuity was 20/30, corrected to 20/25 with a refraction of -2.00 in the diopter sphere with no residual astigmatism. The artificial iris implant and toric-intraocular lens were well-centered. The patient was satisfied with the visual and cosmetic outcomes. This procedure, however, is not complication-free as our patient developed uveitis and increased intraocular pressure during the postoperative period, which was treated successfully.
Topics: Humans; Iris; Lenses, Intraocular; Sclera; Lens Implantation, Intraocular; Visual Acuity; Astigmatism; Male; Aniridia; Female
PubMed: 38929482
DOI: 10.3390/medicina60060865 -
Medicina (Kaunas, Lithuania) May 2024: The role of surgical extraction of the third molar in patients' sleep quality remains unclear, although it is one of the most common oral surgical procedures. The aim... (Observational Study)
Observational Study
: The role of surgical extraction of the third molar in patients' sleep quality remains unclear, although it is one of the most common oral surgical procedures. The aim of this study is to assess the changes in patient-reported sleep health outcomes after third molar surgery and to investigate any associations between sleep parameters and post-extraction pain. : Young adults without known comorbidities who were in need of mandibular third molar surgical extraction were included. All participants completed a sleep diary, the Epworth Sleepiness Scale (ESS), Pittsburgh Sleep Quality Index (PSQI) and Athens Insomnia Scale (AIS) questionnaires, which were used to assess sleep habits, daytime sleepiness, sleep quality and insomnia severity one week before and after extraction. In addition, a visual analog scale was completed postoperatively to assess the perception of pain. : Out of 75 patients who completed the study protocol, 32 (42.7%) were males and 43 (57.3%) were females, with a mean age of 24.01 (±3.43) years. Postoperatively, statistically significant higher scores were observed for PSQI [4.85 (±2.32) before vs. 5.39 (±2.75) after, = 0.041], AIS [5.56 (±3.23) before vs. 6.91 (±4.06) after, < 0.001] and average weekly number of nocturnal awakenings [2.01 (±3.72) before vs. 4.19 (±5.20) after, < 0.001] but not for ESS, average weekly sleep duration and average weekly sleep onset latency. Pain perception was increased in patients who slept worse on almost all seven postoperative days, although this did not reach statistical significance. : Third molar surgery impacts sleep quality and insomnia severity in the first week after extraction, while there is no effect on daytime sleepiness. The worsening of subjective sleep symptoms after extraction may be associated with an increased perception of pain.
Topics: Humans; Female; Male; Molar, Third; Adult; Tooth Extraction; Young Adult; Surveys and Questionnaires; Sleep Quality; Pain, Postoperative; Sleep Initiation and Maintenance Disorders
PubMed: 38929475
DOI: 10.3390/medicina60060858 -
Foods (Basel, Switzerland) Jun 2024Packaging design is pivotal in motivating consumer decisions, as a key communication tool from creation to purchase. Currently, the interpretation and evaluation of...
Packaging design is pivotal in motivating consumer decisions, as a key communication tool from creation to purchase. Currently, the interpretation and evaluation of packaging's impact are shifting toward non-traditional methods. This pilot study evaluated the packaging perception of York Ham and Turkey Breast products. The event-related potential (ERP) technique, the methodology priming words (positive and negative), and target images (original and modified packaging) were applied. A total of 23 participants were sampled using a 32-channels scalp elastic electrode cap and viewed 200 trials of word-image matching. Participants responded whether the images and adjectives matched or not, using the two groups of images. The results demonstrate an N400 effect in the parietal area. This region was observed to show evidence of cognitive processing related to congruency or incongruency, by contrasting the priming and target of this study. The evaluation positioned the York Ham packaging as the best rated. The findings show a relevant contribution to ERPs and research related to the food packaging perception.
PubMed: 38928817
DOI: 10.3390/foods13121876 -
Bioengineering (Basel, Switzerland) May 2024Automatically segmenting polyps from colonoscopy videos is crucial for developing computer-assisted diagnostic systems for colorectal cancer. Existing automatic polyp...
Automatically segmenting polyps from colonoscopy videos is crucial for developing computer-assisted diagnostic systems for colorectal cancer. Existing automatic polyp segmentation methods often struggle to fulfill the real-time demands of clinical applications due to their substantial parameter count and computational load, especially those based on Transformer architectures. To tackle these challenges, a novel lightweight long-range context fusion network, named LightCF-Net, is proposed in this paper. This network attempts to model long-range spatial dependencies while maintaining real-time performance, to better distinguish polyps from background noise and thus improve segmentation accuracy. A novel Fusion Attention Encoder (FAEncoder) is designed in the proposed network, which integrates Large Kernel Attention (LKA) and channel attention mechanisms to extract deep representational features of polyps and unearth long-range dependencies. Furthermore, a newly designed Visual Attention Mamba module (VAM) is added to the skip connections, modeling long-range context dependencies in the encoder-extracted features and reducing background noise interference through the attention mechanism. Finally, a Pyramid Split Attention module (PSA) is used in the bottleneck layer to extract richer multi-scale contextual features. The proposed method was thoroughly evaluated on four renowned polyp segmentation datasets: Kvasir-SEG, CVC-ClinicDB, BKAI-IGH, and ETIS. Experimental findings demonstrate that the proposed method delivers higher segmentation accuracy in less time, consistently outperforming the most advanced lightweight polyp segmentation networks.
PubMed: 38927781
DOI: 10.3390/bioengineering11060545 -
Genes Jun 2024The retinal features of Bardet-Biedl syndrome (BBS) are insufficiently characterized in Arab populations. This retrospective study investigated the retinal features and...
The retinal features of Bardet-Biedl syndrome (BBS) are insufficiently characterized in Arab populations. This retrospective study investigated the retinal features and genotypes of BBS in Saudi patients managed at a single tertiary eye care center. Data analysis of the identified 46 individuals from 31 families included visual acuity (VA), systemic manifestations, multimodal retinal imaging, electroretinography (ERG), family pedigrees, and genotypes. Patients were classified to have cone-rod, rod-cone, or generalized photoreceptor dystrophy based on the pattern of macular involvement on the retinal imaging. Results showed that nyctalopia and subnormal VA were the most common symptoms with 76% having VA ≤ 20/200 at the last visit (age: 5-35). Systemic features included obesity 91%, polydactyly 56.5%, and severe cognitive impairment 33%. The predominant retinal phenotype was cone-rod dystrophy 75%, 10% had rod-cone dystrophy and 15% had generalized photoreceptor dystrophy. ERGs were undetectable in 95% of patients. Among the 31 probands, 61% had biallelic variants in BBSome complex genes, 32% in chaperonin complex genes, and 6% had biallelic variants in ; including six previously unreported variants. Interfamilial and intrafamilial variabilities were noted, without a clear genotype-phenotype correlation. Most BBS patients had advanced retinopathy and were legally blind by early adulthood, indicating a narrow therapeutic window for rescue strategies.
Topics: Humans; Bardet-Biedl Syndrome; Male; Saudi Arabia; Female; Child; Adolescent; Adult; Child, Preschool; Mutation; Young Adult; Pedigree; Retrospective Studies; Electroretinography; Phenotype; Visual Acuity; Retina; ADP-Ribosylation Factors
PubMed: 38927698
DOI: 10.3390/genes15060762