-
European Journal of Orthodontics Nov 2023To systematically assess the scientific literature for the prevalence of failure rate of fixed orthodontic bonded retainer (FOBR). (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To systematically assess the scientific literature for the prevalence of failure rate of fixed orthodontic bonded retainer (FOBR).
METHOD
Randomized clinical trials (RCTs) and prospective non-RCTs involving participants who had FOBR fitted were included. The Cochrane Central Register of Controlled Trials, Web of science, MEDLINE, and EMBASE via OVID were searched from inception to January 2023. Risk of bias was assessed using the Cochrane RoB 2 and Newcastle-Ottawa tools. The main outcome was the failure rate of FOBRs. The secondary outcome was to identify factors that can influence the failure of FOBR. Meta-analyses and sensitivity analyses were undertaken using Revman, version5.4. A random-effects model was used. Quality assessment using Grading of Recommendations Assessment, Development, and Evaluation.
RESULTS
Thirty-four studies (25 RCTs and 9 prospective clinical studies) (3484 participants) were included in this review. The overall failure rate of bonded retainers, after excluding high-risk studies, was 35.22% (95% confidence interval [CI] 27.46-42.98). The failure rate is increased with the duration of follow up; with short-term follow-up rate 24.18% (95% CI 20.16-28.21), medium-term follow up 40.09% (95% CI 30.92-49.26), and long-term follow up 53.85% (95% CI 40.31-67.39). There is a low level of evidence to suggest there is no statistically significant difference in the failure rate of fixed retainers using direct versus indirect bonding methods, using liquid resin versus without liquid resin, and fibre-reinforced composite retainers compared to multi-stranded stainless steel retainers.
DISCUSSION
There is low-quality evidence to suggest that the failure rate of FOBR is relatively high. There is a need for high-quality, well-reported clinical studies to assess factors that can influence the failure rate of FOBR.
REGISTRATION
CRD42021190910.
Topics: Humans; Prevalence; Orthodontic Appliances, Fixed; Prospective Studies; Orthodontic Retainers; Stainless Steel
PubMed: 37824794
DOI: 10.1093/ejo/cjad047 -
Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159 -
Clinical Oral Implants Research Sep 2023For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years.
MATERIALS AND METHODS
An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD.
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients).
CONCLUSIONS
After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Topics: Humans; Dental Implants; Prospective Studies; Retrospective Studies; Titanium; Bone Diseases, Metabolic
PubMed: 37750521
DOI: 10.1111/clr.14133 -
International Journal of Implant... Jul 2023The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated.
METHODS
Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures.
RESULTS
Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36-141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients' reported increased satisfaction with ZIs.
CONCLUSIONS
ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.
Topics: Humans; Dental Implantation, Endosseous; Dental Implants; Prosthesis Failure; Titanium; Treatment Outcome; Alloys
PubMed: 37405545
DOI: 10.1186/s40729-023-00479-x -
Neurospine Jun 2023Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2...
Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2 most commonly employed cage materials are titanium (Ti) alloy and polyetheretherketone (PEEK). While Ti alloy implants have superior osteoinductive properties they more poorly match the biomechanical properties of cancellous bones. Newly developed 3-dimensional (3D)-printed porous titanium (3D-pTi) address this disadvantage and are proposed as a new standard for lumbar interbody fusion (LIF) devices. In the present study, the literature directly comparing 3D-pTi and PEEK interbody devices is systematically reviewed with a focus on fusion outcomes and subsidence rates reported in the in vitro, animal, and human literature. A systematic review directly comparing outcomes of PEEK and 3D-pTi interbody spinal cages was performed. PubMed, Embase, and Cochrane Library databases were searched according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. Mean Newcastle-Ottawa Scale score for cohort studies was 6.4. A total of 7 eligible studies were included, comprising a combination of clinical series, ovine animal data, and in vitro biomechanical studies. There was a total population of 299 human and 59 ovine subjects, with 134 human (44.8%) and 38 (64.4%) ovine models implanted with 3D-pTi cages. Of the 7 studies, 6 reported overall outcomes in favor of 3D-pTi compared to PEEK, including subsidence and osseointegration, while 1 study reported neutral outcomes for device related revision and reoperation rate. Though limited data are available, the current literature supports 3D-pTi interbodies as offering superior fusion outcomes relative to PEEK interbodies for LIF without increasing subsidence or reoperation risk. Histologic evidence suggests 3D-Ti to have superior osteoinductive properties that may underlie these superior outcomes, but additional clinical investigation is merited.
PubMed: 37401063
DOI: 10.14245/ns.2346244.122 -
Antibiotics (Basel, Switzerland) Jun 2023Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level.... (Review)
Review
Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.
PubMed: 37370313
DOI: 10.3390/antibiotics12060994 -
The British Journal of Oral &... Jul 2023Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The... (Meta-Analysis)
Meta-Analysis Review
Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The purpose of this systematic review and meta-analysis was to evaluate clinical evidence, including survival rates, success rates, and marginal bone loss (MBL) on Ti-Zr NDIs that support single crowns. An extensive search was performed in the databases of PubMed/MEDLINE, Scopus, Embase, and the Cochrane Library for studies published in English up to April 2022. Only peer-reviewed clinical studies with at least 10 patients and a follow-up time of at least 12 months were included. Risk of bias in each study was assessed and data extraction was carried out independently by two reviewers. The outcome variables were survival rates, success rates, and MBL. The search returned 779 results. Eight studies were identified for qualitative analysis and seven for quantitative synthesis. Overall, a total of 256 Ti-Zr NDIs were included. Cumulative implant survival rates and success rates were 97.5% (95% confidence interval (CI): 94.5% to 98.9%) and 97.2% (95% CI: 94.2% to 98.7%), respectively, over a maximum follow-up period of 36 months, with no difference between Ti-Zr NDIs and commercial pure titanium (cpTi) implants. Cumulative mean (SD) MBL was 0.44 (0.04) mm (95% CI: 0.36 to 0.52) after one year. Meta-analysis of MBL indicated a mean difference of 0.02 mm (95% CI: -0.23 to 0.10), with no differences between Ti-Zr NDIs and cpTi implants. Short-term results of Ti-Zr NDIs for single-crown restorations are quite promising, although the number of published studies and follow-up periods are insufficient to determine the real benefit for single crowns. Long-term, follow-up clinical studies are needed to verify the excellent clinical performance of Ti-Zr NDIs.
Topics: Humans; Titanium; Zirconium; Dental Prosthesis Design; Alloys; Crowns; Dental Implants; Dental Restoration Failure
PubMed: 37331853
DOI: 10.1016/j.bjoms.2023.05.005 -
Journal of Functional Biomaterials Apr 2023Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This... (Review)
Review
Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This work aims to investigate whether Zn and its alloys possess cytotoxic effects and the corresponding influence factors. According to the guidelines of the PRISMA statement, an electronic combined hand search was conducted to retrieve articles published in PubMed, Web of Science, and Scopus (2013.1-2023.2) following the PICOS strategy. Eighty-six eligible articles were included. The quality of the included toxicity studies was assessed utilizing the ToxRTool. Among the included articles, extract tests were performed in 83 studies, and direct contact tests were conducted in 18 studies. According to the results of this review, the cytotoxicity of Zn-based BMs is mainly determined by three factors, namely, Zn-based materials, tested cells, and test system. Notably, Zn and its alloys did not exhibit cytotoxic effects under certain test conditions, but significant heterogeneity existed in the implementation of the cytotoxicity evaluation. Furthermore, there is currently a relatively lower quality of current cytotoxicity evaluation in Zn-based BMs owing to the adoption of nonuniform standards. Establishing a standardized in vitro toxicity assessment system for Zn-based BMs is required for future investigations.
PubMed: 37103296
DOI: 10.3390/jfb14040206 -
EFORT Open Reviews Apr 2023The biomechanical characteristics of different techniques to perform the modified Lapidus procedure are controversial, discussing the issue of stability, rigidity, and... (Review)
Review
PURPOSE
The biomechanical characteristics of different techniques to perform the modified Lapidus procedure are controversial, discussing the issue of stability, rigidity, and compression forces from a biomechanical point of view. The aim of this systematic review was to investigate the available options to identify whether there is a procedure providing superior biomechanical results.
METHODS
A comprehensive literature search was performed by screening PubMed, Embase, and Cochrane databases until September 2021. There was a wide heterogeneity of the available data in the different studies. Load to failure, stiffness, and compression forces were summarized and evaluated.
RESULTS
Seventeen biomechanical studies were retrieved - ten cadaveric and seven polyurethane foam (artificial bone) studies. Fixation methods ranged from the classic crossed screw approach (n = 5) to plates (dorsomedial and plantar) with or without compression screws (n = 11). Newer implants such as intramedullary stabilization screws (n = 1) and memory alloy staples (n = 2) were investigated.
CONCLUSION
The two crossed screws construct is still a biomechanical option; however, according to this systematic review, there is strong evidence that a plate-screw construct provides superior stability especially in combination with a compression screw. There is also evidence about plate position and low evidence about compression screw position. Plantar plates seem to be advantageous from a biomechanical point of view, whereas compression screws could be better when positioned outside the plate. Overall, this review suggests the biomechanical advantages of using a combination of locking plates with a compression screw.
PubMed: 37097047
DOI: 10.1530/EOR-22-0069 -
Neuroscience and Biobehavioral Reviews Jul 2023Elevated inflammation is a risk factor for many psychiatric (e.g., depression) and somatic conditions (e.g., rheumatoid arthritis). Inflammation is influenced by... (Review)
Review
Elevated inflammation is a risk factor for many psychiatric (e.g., depression) and somatic conditions (e.g., rheumatoid arthritis). Inflammation is influenced by psychosocial processes such as emotion regulation. Characterization of which emotion regulation characteristics impact inflammation could help refine psychosocial interventions aimed at normalizing health-harming inflammatory activity for individuals with psychiatric and somatic illnesses. To investigate this issue, we systematically reviewed the literature on associations between a variety of emotion regulation traits and inflammation. Out of 2816 articles identified, 38 were included in the final review. 28 (74%) found that (a) poor emotion regulation is associated with higher inflammation and/or (b) strong emotion regulation skills are associated with lower inflammation. Consistency of results differed as a function of the emotion regulation construct investigated and methodological characteristics. Results were most consistent for studies testing positive coping/social support seeking or broadly defined emotion regulation/dysregulation. Methodologically, studies testing reactivity to a stressor, adopting a vulnerability-stress framework, or using longitudinal data were most consistent. Implications for integrated, transdiagnostic psychoimmunological theories are discussed, as well as recommendations for clinical research.
Topics: Humans; Emotions; Emotional Regulation; Inflammation; Risk Factors; Phenotype
PubMed: 37028579
DOI: 10.1016/j.neubiorev.2023.105162