BMC Oral Health Jul 2023Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better... (Meta-Analysis)
Meta-Analysis
BACKGROUND AND OBJECTIVES
Polyvinyl ether siloxane (PVES) possesses ideal characteristics for making precise and accurate dental impressions. PVES dimensional stability owes to its better polymeric properties derived from its parent materials poly ethers and polyvinyl siloxanes. As recommended use of chemical disinfecting agents is getting more popular, there is a growing concern associated with the effect of disinfectants on PVES dimensional stability. This study was aimed to understand the PVES behavior when subjected to chemical disinfectants.
MATERIALS AND METHODOLOGY
The data was collected from research studies retrieved from Google Scholar, Scopus, and PubMed using MeSH terms of keywords "vinyl polyether siloxane AND Disinfection" or (Vinyl polyether siloxane OR polyvinyl siloxane ether OR PVES) AND (disinfectant OR disinfection)" without any restriction to publication date. The PRISMA (Preferred Reporting Items for Systemic Review and Meta-Analysis) directions were observed during the data collection, screening of studies, and meta-analysis. The primary data were retrieved, and batch exported from databases using Harzing's Publish or Perish software; primary analysis was performed in Microsoft Excel, while statistical analysis for effect size, two-tailed p-values, and heterogeneity among studies was performed using Meta Essentials. The effect size was calculated using Hedge's g values at the 95% confidence level using the random-effects model. Heterogeneity among studies was measured using the Cochrane Q and I.
RESULTS AND CONCLUSION
Dental impressions made from the PVES elastomeric impression materials showed no significant changes in dimensional stability. Immersion in the chemical disinfectant for 10 min was associated with clinically irrelevant changes in the dimensions of the PVES impressions. Disinfection with sodium hypochlorite was associated with clinically significant changes in dimensions, with a two-tailed p-value of 0.049. Disinfection with 2-2.5% glutaraldehyde solution was not associated with any significant dimensional variability.
Topics: Humans; Disinfectants; Disinfection; Ether; Ethers; Ethyl Ethers; Polyvinyls; Siloxanes
PubMed: 37430254
DOI: 10.1186/s12903-023-03168-8 -
PeerJ 2023To systematically evaluate the disinfection efficacy of the two most frequently used disinfectants, sodium hypochlorite and glutaraldehyde, and their effects on the...
Disinfection efficacy of sodium hypochlorite and glutaraldehyde and their effects on the dimensional stability and surface properties of dental impressions: a systematic review.
OBJECTIVE
To systematically evaluate the disinfection efficacy of the two most frequently used disinfectants, sodium hypochlorite and glutaraldehyde, and their effects on the surface properties of four different dental impression materials.
METHODS
A systematic literature search was performed in four databases until May 1st, 2022 to select the studies which evaluated disinfection efficacy of disinfectants or surface properties of dental impressions after chemical disinfection.
MAIN RESULTS
A total of 50 studies were included through electronic database searches. Of these studies, 13 studies evaluated disinfection efficacy of two disinfectants, and 39 studies evaluated their effects on the surface properties of dental impressions. A 10-minute disinfection with 0.5-1% sodium hypochlorite or 2% glutaraldehyde was effective to inactivate oral flora and common oral pathogenic bacteria. With regard to surface properties, chemical disinfection within 30 min could not alter the dimensional stability, detail reproduction and wettability of alginate and polyether impressions. However, the wettability of addition silicone impressions and the dimensional stability of condensation silicone impressions were adversely affected after chemical disinfection, while other surface properties of these two dental impressions were out of significant influence.
CONCLUSIONS
Alginate impressions are strongly recommended to be disinfected with 0.5% sodium hypochlorite using spray disinfection method for 10 min. Meanwhile, elastomeric impressions are strongly recommended to be disinfected with 0.5% sodium hypochlorite or 2% glutaraldehyde using immersion disinfection method for 10 min, however, polyether impression should be disinfected with 2% glutaraldehyde.
Topics: Sodium Hypochlorite; Glutaral; Disinfection; Time Factors; Disinfectants; Surface Properties; Silicones; Alginates; Bacteria
PubMed: 36846444
DOI: 10.7717/peerj.14868 -
Bioengineering (Basel, Switzerland) Mar 2022Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants... (Review)
Review
Dental impressions are contaminated with potentially pathogenic microorganisms when they come into contact with patient blood, saliva, and plaque. Numerous disinfectants are used; however, no sole disinfectant can be designated as universal for all the impression materials. Thus, the aim of this study is to systemically review the literature to evaluate the effect of the existing disinfection procedures on the bacterial colonization of dental impression materials. This systematic review and meta-analysis was conducted according to the PRISMA statement. PubMed (MEDLINE), Web of Science, Scopus, EMBASE, and SciELO databases were screened up to April 2021. Eligibility criteria included in vitro studies reporting the antibacterial activity of disinfectant solutions in dental impression materials. The meta-analysis was performed using Review Manager (version 5.3.5). A global comparison was performed with the standardized mean difference based on random-effect models at a significance level of α = 0.05. A total of seven studies were included in the meta-analysis. The included studies described the effect of disinfection processes with chlorhexidine gluconate, alcohol, sodium hypochlorite, glutaraldehyde, and hydrogen peroxide in alginate, polyvinyl siloxane, and polyether impression materials. The meta-analyses showed that the use of chlorhexidine, alcohol, glutaraldehyde, and sodium hypochlorite reduced the colony-forming units by a milliliter (CFU/mL) in alginate (p < 0.001). On the other hand, glutaraldehyde, sodium hypochlorite, and alcohol reduced the CFU/mL in polyvinyl siloxane (p < 0.001). Finally, alcohol and glutaraldehyde reduced the CFU/mL in polyether material (p < 0.001). High heterogenicity was observed for the alginate and polyvinyl siloxane materials (I2 = 74%; I2 = 90%). Based on these in vitro studies, the disinfection of impression materials with several disinfection agents reduces the CFU/mL count.
PubMed: 35324812
DOI: 10.3390/bioengineering9030123 -
Gels (Basel, Switzerland) Mar 2022Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to... (Review)
Review
Immediate dentin sealing (IDS) involves applying an adhesive system to dentin directly after tooth preparation, before impression. This was considered an alternate to delayed dentin sealing (DDS), a technique in which hybridization is performed following the provisional phase and just before the indirect restoration luting procedure. This study aimed to compare the bond strength of restorations to dentin of the IDS and the DDS techniques throughout a systematic review and meta-analysis. The following PICOS framework was used: population, indirect restorations; intervention, IDS; control, DDS; outcomes, bond strength; and study design, in vitro studies. PubMed (MedLine), The Cochrane Library, ISI Web of Science, Scielo, Scopus, and Embase were screened up to January 2022 by two reviewers (L.H. and R.B.). In vitro papers studying the bond strength to human dentin of the IDS technique compared to the DDS technique were considered. Meta-analyses were carried out by using a software program (Review Manager v5.4.1; The Cochrane Collaboration). Comparisons were made by considering the adhesive used for bonding (two-step etch-and-rinse, three step etch-and-rinse, one-step self-etch, two-step self-etch, and universal adhesives). A total of 3717 papers were retrieved in all databases. After full-text assessment, 22 potentially eligible studies were examined for qualitative analysis, leaving a total of 21 articles for the meta-analysis. For the immediate bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p < 0.001). Taking into account the subgroup analysis, it seems that the use of the IDS technique with a two-step etch-and-rinse or a one-step self-etch adhesive system does not represent any advantage over the DDS technique (p = 0.07, p = 0.15). On the other hand, for the aged bond strength, regardless of the adhesive strategy used, the IDS technique improved the bond strength of restorations to the dentin (p = 0.001). The subgroups analysis shows that this improvement is observed only when a three-step etch-and-rinse adhesive system (p < 0.001) or when a combination of an adhesive system plus a layer of flowable resin (p = 0.01) is used. The in vitro evidence suggests that the use of the IDS technique improves the bond strength of dentin to resin-based restorations regardless of the adhesive strategy used. The use of a three-step etch-and-rinse adhesive system or the combination of an adhesive system plus a layer of flowable resin seems to considerably enhance the bond strength in the long term.
PubMed: 35323288
DOI: 10.3390/gels8030175 -
Clinical Oral Investigations Dec 2021The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures... (Review)
Review
OBJECTIVES
The primary aim of this systematic review was to evaluate whether intraoral scanning (IOS) is able to reduce working time and improve patient-reported outcome measures (PROMs) compared to conventional impression (CI) techniques, taking into account the size of the scanned area. The secondary aim was to verify the effectiveness of IOS procedures based on available prosthodontic outcomes.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the outcomes of IOS and CI performed during the treatment of partially and complete edentulous patients for tooth- or implant-supported restorations. Qualitative analysis was conducted to evaluate the time efficiency and PROMs produced by the two different techniques. Clinical prosthodontic outcomes were analyzed among the included studies when available.
RESULTS
Seventeen studies (9 randomized controlled trials and 8 prospective clinical studies) were selected for qualitative synthesis. The 17 included studies provided data from 430 IOS and 370 CI performed in 437 patients. A total of 7 different IOS systems and their various updated versions were used for digital impressions. The results demonstrated that IOS was overall faster than CI independent of whether quadrant or complete-arch scanning was utilized, regardless of the nature of the restoration (tooth or implant supported). IOS was generally preferred over CI regardless of the size of the scanned area and nature of the restoration (tooth- or implant-supported). Similar prosthodontic outcomes were reported for workflows implementing CI and IOS.
CONCLUSIONS
Within the limitations of this systematic review, IOS is faster than CI, independent of whether a quadrant or complete arch scan is conducted. IOS can improve the patient experience measured by overall preference and comfort and is able to provide reliable prosthodontic outcomes.
CLINICAL RELEVANCE
Reduced procedure working time associated with the use of IOS can improve clinical efficiency and the patient experience during impression procedures. Patient-reported outcome measures (PROMs) are an essential component of evidence-based dental practice as they allow the evaluation of therapeutic modalities from the perspective of the patient. IOS is generally preferred by patients over conventional impressions.
Topics: Computer-Aided Design; Dental Implants; Dental Impression Technique; Humans; Patient Comfort; Prospective Studies; Prosthodontics
PubMed: 34568955
DOI: 10.1007/s00784-021-04157-3 -
Journal of Prosthodontic Research Jan 2022This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case...
PURPOSE
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
STUDY SELECTION
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
RESULTS
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
CONCLUSIONS
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
Topics: Computer-Aided Design; Denture, Partial, Removable; Humans; Mouth, Edentulous; Randomized Controlled Trials as Topic
PubMed: 33504721
DOI: 10.2186/jpr.JPR_D_20_00116 -
Journal of Healthcare Engineering 2020The purpose of this systematic review was to compare the accuracy of the three-dimensional images among different scanners, scanning techniques, and substrates. .... (Review)
Review
INTRODUCTION
The purpose of this systematic review was to compare the accuracy of the three-dimensional images among different scanners, scanning techniques, and substrates. . Electronic databases (PubMed and Elsevier) were searched until March 2020. The systematic search was performed to identify the most precise method of obtaining a 3D image of the dentition.
RESULTS
Thirteen articles out of 221, considering the accuracy of 3D images, were selected. The main factors that are considered to have an influence on the precision are substrate type in the oral cavity, experience of the scanner's operator, direct vs. indirect scanning, and the reproducibility of the procedure.
CONCLUSION
Substrate type does have an impact on the overall accuracy of intraoral scans where dentin has the most and enamel the least accurately recorded dental structure. Experience of the operator has an influence on the accuracy, where more experienced operators and smaller scan sizes are made for more accurate scans. A conventional impression technique in a full-arch image provided the lowest deviation. The reproducibility of direct scanning was comparable to indirect scanning although a slight difference was noticeable (0.02 mm).
Topics: Computer-Aided Design; Dental Impression Technique; Humans; Imaging, Three-Dimensional; Models, Dental; Mouth; Reproducibility of Results; Research Design
PubMed: 33414902
DOI: 10.1155/2020/8854204 -
Journal of Prosthodontic Research Oct 2021Purpose To clarify the rate of posterior residual ridge resorption (PRRR) in different denture treatments and the factors that can affect PRRR.Study selection A...
Purpose To clarify the rate of posterior residual ridge resorption (PRRR) in different denture treatments and the factors that can affect PRRR.Study selection A bibliographical electronic search was conducted on MeSH, Web of Science, and Ovid databases. Hand searching was also conducted. Longitudinal studies recording the average rate of PRRR in the mandible were included. The effect size was calculated based on the mean rate of PRRR with standard deviation and group size. The random-effects analysis was used to perform meta-analyses across qualified studies.Results A total of 2245 eligible studies were collected from the MeSH, Web of Science, and Ovid databases and hand searching. In the end, 19 studies met the inclusion criteria and were extracted. The average rate of PRRR in different mandibular denture treatments was assessed in this systematic review. The mean combined effect size was -1.05 ± 0.5 (95% confidence interval [CI]: -3.18-1.08) between four-implant overdentures and two-implant overdentures. The combined effect size was -0.01 ± 0.22 (95% CI: -0.93-0.82) between complete dentures and two-implant overdentures. Body mass index, number of dentures used, denture wearing habit, impression technique, artificial tooth material, and peri-implant bone resorption showed no significant effect on the rate of PRRR. Gender, denture material, and relining frequency showed a significant effect on the rate of PRRR.Conclusions This review summarized different average rates of PRRR in mandibular denture treatments. Meta-analyses have reported that four-implant overdenture treatments can lower the rate of PRRR compared to two-implant overdenture treatments. However, there was no significant difference in the treatment effect between the complete denture and two-implant overdenture treatments.
Topics: Bone Resorption; Dental Prosthesis, Implant-Supported; Denture, Complete; Denture, Overlay; Humans; Mandible
PubMed: 33281173
DOI: 10.2186/jpr.JPR_D_20_00075 -
Clinical Implant Dentistry and Related... Dec 2020Accurate implant placement is essential in reducing post-treatment complications and in ensuring a successful treatment outcome. (Meta-Analysis)
Meta-Analysis
BACKGROUND
Accurate implant placement is essential in reducing post-treatment complications and in ensuring a successful treatment outcome.
PURPOSE
To compare the accuracy of fully-guided static computer-assisted implant surgery (s-CAIS) using partially- and fully-digital workflows.
MATERIALS AND METHODS
Electronic and manual literature searches were performed to collect evidence concerning the accuracy of fully-guided s-CAIS procedures utilizing tooth-supported guides. Quantitative analysis was conducted to evaluate the accuracy of partially- and fully-digital workflows, and survival rates and complications were qualitatively analyzed.
RESULTS
Thirteen studies, including 6 randomized controlled trials and 7 prospective clinical studies, were selected for quantitative and qualitative synthesis. A total of 669 implants in 325 patients using s-CAIS were available for review. Meta-analysis of the accuracy revealed a total mean angular deviation of 2.68° (95% CI: 2.32°-3.03°); mean global coronal deviation of 1.03 mm (95% CI: 0.88-1.18 mm); mean global apical deviation of 1.33 mm (95% CI: 1.17-1.50 mm); and mean depth deviation of 0.59 mm (95% CI: 0.46-0.70 mm). Minimal differences were found between the two different workflows. Few complications were reported, and survival rates were between 97.8% to 100% (range of follow-up: 12 to 24 months) in the available studies.
CONCLUSION
Similar accuracy is obtained when implants are placed in partially edentulous patients using fully-guided s-CAIS, independently of the workflow utilized.
Topics: Computer-Aided Design; Computers; Dental Implantation, Endosseous; Dental Implants; Humans; Prospective Studies; Surgery, Computer-Assisted; Workflow
PubMed: 32964614
DOI: 10.1111/cid.12937 -
Journal of Clinical and Experimental... Aug 2020This systematic review aimed to evaluate the efficiency and accuracy of digital impression techniques for implant-supported restorations, and to assess their economic... (Review)
Review
BACKGROUND
This systematic review aimed to evaluate the efficiency and accuracy of digital impression techniques for implant-supported restorations, and to assess their economic feasibility.
MATERIAL AND METHODS
Two independent electronic database searches were conducted in the Pubmed/MedLine, Cochrane Library, and Lilacs databases complimented by a manual search, selecting relevant clinical and studies published between 1st January 2009 and 28st February 2019. All type of studies ( and ) were included in this systematic review.
RESULTS
Twenty-seven studies (8 and 19 studies) fulfilled the inclusion criteria. No meta-analysis was performed due to a large heterogeneity of the study protocols. The passive fit of superstructures on dental implants presented similar results between digital and conventional impression techniques. The studies considered that several factors influence the accuracy of implant impression taking: distance and angulation between implants, depth of placement, type of scanner, scanning strategy, characteristics of scanbody, and operator experience. Regarding the economic viability of intraoral scanning systems, only one study reported any benefit in comparison with conventional techniques.
CONCLUSIONS
Digital impressions of dental implants can be considered a viable alternative in cases of one or two contiguous dental implants. However, more studies are needed to evaluate the accuracy of digital techniques in full-arch implant-supported restorations. Intraoral scanner, dental implant, prosthesis, misfit, systematic review.
PubMed: 32913577
DOI: 10.4317/jced.57025