Journal of Indian Prosthodontic Society 2020Intraoral scanner (IOS) is a medical device used for capturing direct optical impressions and composed of a handheld camera (hardware), a computer and software. Digital... (Review)
Review
BACKGROUND
Intraoral scanner (IOS) is a medical device used for capturing direct optical impressions and composed of a handheld camera (hardware), a computer and software. Digital impressions by intraoral scanning have become an increasingly popular alternative to conventional impressions. The aim of this systematic review is to assess the studies regarding the various available technologies for IOS and evaluate the most accurate IOS system for cases with multiple implants and identify the factors that can influence its accuracy.
MATERIALS AND METHODS
A comprehensive electronic search was done in online databases, 'Pubmed', 'Google Scholar' and 'Cochrane' based on pre-determined eligibility criteria. In-vitro studies, In-vivo studies and Randomized controlled trials assessing the accuracy of intra-oral scanner technology were selected after thorough screening. The search strategy covered all studies published until February 2019 and yielded a total of 11 articles out of which 8 studies were determined to fulfil the inclusion criteria and were selected for this review. Data extraction from the included studies was conducted by the primary author and reviewed by the second author.
RESULTS
The information collected included sample size and population, study design, intervention, scanning methods, comparisons and outcome measures. 5 out of 8 included studies compared the distance deviation of the acquired scans from the true values while the remaining 3 studies gave trueness and precision values as the outcome variables. A forest plot on scanner precision displayed slightly higher precision levels in the TRIOS scanner compared to the other intraoral scanners.
CONCLUSION
Despite the limitations this study, it can be concluded that active wavefront sampling is more accurate than the other intraoral scanning technology employed by commercial scanners.
PubMed: 32655218
DOI: 10.4103/jips.jips_379_19 -
The Saudi Dental Journal May 2020The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their... (Review)
Review
Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.
OBJECTIVES
The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their effect on properties of the different impression materials.
MATERIAL AND METHODS
An electronic search of MEDLINE (PubMed), Science Direct, and Google Scholar databases was performed to retrieve related English-language articles published between January 2000 and July 2019. Available studies with search terms such as: Impression disinfection, disinfection method, impression dimensional stability and impression wettability were used. The selected articles were reviewed by screening their titles and abstracts and full text. Finally, a total of 70 articles were considered relevant and were included in this study.
RESULTS
Extensive studies were conducted to determine the effect of the different disinfection methods and materials on the properties of the different impression materials such as dimensional stability, wettability and surface roughness. While some studies reported significant changes in the properties of the impression materials, others reported either no changes or minor insignificant effects.
CONCLUSIONS
Some studies reported significant changes in the properties of the impression materials as a result of using different disinfection methods, whereas others reported either minor insignificant or no changes. Although the findings of the studies were controversial, care should be taken to avoid distortion of impressions and loss of their surface details that can adversely affect the fitting accuracy of the restorations. Therefore, better designed and standardized studies are needed to evaluate the effect of different commonly used disinfectants on properties of impression materials. Moreover, manufacturers should be encouraged to recommend specific disinfection methods and materials for disinfecting the impression materials to ensure their optimal accuracy.
PubMed: 32405219
DOI: 10.1016/j.sdentj.2019.12.003 -
Materials (Basel, Switzerland) Apr 2020The advent of new technologies in the field of medicine and dentistry is giving improvements that lead the clinicians to have materials and procedures able to improve... (Review)
Review
The advent of new technologies in the field of medicine and dentistry is giving improvements that lead the clinicians to have materials and procedures able to improve patients' quality of life. In dentistry, the last digital techniques offer a fully digital computerized workflow that does not include the standard multiple traditional phases. The purpose of this study is to evaluate all clinical trials and clinical randomized trials related to the digital or dental impression technique in prosthetic dentistry trying to give the readers global information about advantages and disadvantages of each procedure. Data collection was conducted in the main scientific search engines, including articles from the last 10 years, in order to obtain results that do not concern obsolete impression techniques. Elsevier, Pubmed and Embase have been screened as sources for performing the research. The results data demonstrated how the working time appears to be improved with digital workflow, but without a significant result (P = 0.72596). The papers have been selected following the Population Intervention Comparison Outcome (PICO) question, which is related to the progress on dental impression materials and technique. The comparison between dentists or practitioners with respect to classic impression procedures, and students open to new device and digital techniques seem to be the key factor on the final impression technique choice. Surely, digital techniques will end up supplanting the analogical ones altogether, improving the quality of oral rehabilitations, the economics of dental practice and also the perception by our patients.
PubMed: 32340384
DOI: 10.3390/ma13081982 -
Biomaterial Investigations in Dentistry 2020To compare the fit and assess the accuracy of tooth-supported single and multi-unit FDPs in cobalt chromium fabricated using different manufacturing techniques. A... (Review)
Review
To compare the fit and assess the accuracy of tooth-supported single and multi-unit FDPs in cobalt chromium fabricated using different manufacturing techniques. A systematic search was performed in three databases; PubMed, Scopus, and Web of Science, using clearly specified search terms and inclusion criteria. The search yielded 1071 articles and included 18 articles in the analysis. Data regarding the fit analyses and the methods of manufacturing were extracted and the accuracy was defined as the fit result minus the pre-set cement spacer. Internal gap (IntG) was the mean of all the internal measuring points and total gap (TotG) was the mean of all measuring points (marginal, cervical, chamfer, axial, occlusal). The total gap results for fit and accuracy irrespective of manufacturing technique were 96 μm and 54 μm for single crowns, 107 μm and 54 μm for multi-unit FDPs, and 98 μm and 54 μm for both single crowns and multi-unit FDPs combined. For total gap of single crowns soft milling had the highest accuracy, for multi-unit FDPs additive manufactured restorations had the highest accuracy. With the results grouped by impression technique, the accuracy for total gap was highest for digital impressions and lower for conventional impressions. Due to the inherent limitations of this systematic review, it still remains unclear what effect the manufacturing technique has on the fit of FDPs. However, the descriptive results suggest that the marginal fit of cobalt chromium FDPs is not negatively affected by the manufacturing technique.
PubMed: 32083253