-
Journal of Applied Biomaterials &... 2024Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs)... (Review)
Review
Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.
Topics: Humans; Ceramics; Resin Cements; Dental Porcelain; Dental Prosthesis, Implant-Supported; Denture, Partial, Fixed, Resin-Bonded; Zirconium
PubMed: 38706266
DOI: 10.1177/22808000241250118 -
Journal of Clinical and Experimental... Mar 2024The aim of this systematic review is to determine the effectiveness of self-etching primers in comparison to the conventional protocol with hydrofluoric acid and silane... (Review)
Review
BACKGROUND
The aim of this systematic review is to determine the effectiveness of self-etching primers in comparison to the conventional protocol with hydrofluoric acid and silane treatment for bonding lithium disilicate ceramics.
MATERIAL AND METHODS
The formulated PICO question for this research was: "Does self-etching silane primer surface treatment in lithium disilicate ceramics present a similar bond strength value compared to conventional hydrofluoric acid and silane treatment?". Combinations of words and appropriate truncations were adapted for each database. For the selection, duplicate articles were systematically eliminated using Mendeley software. The Cohen's Kappa statistic was then computed, RoBDEMAT questions were addressed, and the meta-analyses were conducted using RevMan 5.4, at a significance level of 5%.
RESULTS
Two independent reviewers conducted a blind and independent analysis of 190219 articles from PubMed, Scopus, Web of Science, and OpenGrey. Subsequently, they extracted data from 21 studies for the systematic review and in 16 the meta-analysis. In all in vitro studies, the most frequently cited concentration of hydrofluoric acid was 5%. In the meta-analysis, no statistical differences were observed between the two treatments concerning bond strength.
CONCLUSIONS
Self-etching silane primers demonstrate promising results in lithium disilicate bonding, suggesting their potential as an alternative surface treatment to hydrofluoric acids + silane. Lithium disilicate, Hydrofluoric acid, Dental Porcelain, Ceramics, Silanes.
PubMed: 38600931
DOI: 10.4317/jced.61369 -
Journal of Personalized Medicine Feb 2024No systematic review or meta-analysis has been identified that provides a clinician's perspective on the shade selection process for ceramic restorations. The aim of the... (Review)
Review
BACKGROUND
No systematic review or meta-analysis has been identified that provides a clinician's perspective on the shade selection process for ceramic restorations. The aim of the present systematic review is to find and systematize the available knowledge by referring to the methods to assess the color of dental ceramics.
METHODS
The final search was performed on 10 December 2023 in six search engines. The keywords used in the search strategy were as follows: ("color matching" OR "shade matching" OR "color measurement" AND "porcelain" OR "dental ceramics") AND "dentistry" AND "accuracy".
RESULTS
The search strategy identified 139 potential articles. After the screening process, sixteen articles were included in the review.
CONCLUSIONS
In conclusion, the most common method, the visual method, has lower accuracy and repeatability. Devices like spectrophotometers and colorimeters provide precise, repeatable, and objective measurements, but fail to be widely applied in everyday clinical practice. Clinicians should not rely solely on their senses for shade determination, but should turn to quantitative methods. Colorimetric devices connected to mobile applications are an interesting and useful tool. Software and apps based on artificial intelligence are emerging as promising tools, but they require further research.
PubMed: 38540994
DOI: 10.3390/jpm14030252 -
Dental Materials : Official Publication... Mar 2024Nonthermal atmospheric or low-pressure plasma (NTP) can improve the surface characteristics of dental materials without affecting their bulk properties. This study aimed... (Review)
Review
OBJECTIVES
Nonthermal atmospheric or low-pressure plasma (NTP) can improve the surface characteristics of dental materials without affecting their bulk properties. This study aimed to systematically review the available scientific evidence on the effectiveness of using NTP for the surface treatment of etchable, silica-based dental ceramics before cementation, and elucidate its potential to replace the hazardous and technically demanding protocol of hydrofluoric acid (HF) etching.
METHODS
A valid search query was developed with the help of PubMed's Medical Subject Headings (MeSH) vocabulary thesaurus and translated to three electronic databases: PubMed, Web of Science, and Scopus. The methodological quality of the studies was assessed according to an adapted version of the Methodological Index for Non-Randomized Studies (MINORS).
RESULTS
Thirteen in vitro study reports published between 2008 and 2023 were selected for the qualitative and quantitative data synthesis. The implemented methodologies were diverse, comprising 19 different plasma treatment protocols with various device settings. Argon, helium, oxygen, or atmospheric air plasma may significantly increase the wettability and roughness of silicate ceramics by plasma cleaning, etching, and activation, but the treatment generally results in inferior bond strength values after cementation compared to those achieved with HF etching. The technically demanding protocol of plasma-enhanced chemical vapor deposition was employed more commonly, in which the surface deposition of hexamethyl disiloxane with subsequent oxygen plasma activation proved the most promising, yielding bond strengths comparable to those of the positive control. Lack of power analysis, missing adequate control, absence of examiner blinding, and non-performance of specimen aging were common methodological frailties that contributed most to the increase in bias risk (mean MINORS score 15.3 ± 1.1).
SIGNIFICANCE
NTP can potentially improve the adhesive surface characteristics of dental silicate ceramics in laboratory conditions, but the conventional protocol of HF etching still performs better in terms of the resin-ceramic bond strength and longevity. More preclinical research is needed to determine the optimal NTP treatment settings and assess the aging of plasma-treated ceramic surfaces in atmospheric conditions.
Topics: Dental Porcelain; Dental Bonding; Surface Properties; Resin Cements; Ceramics; Silicates; Oxygen; Materials Testing; Hydrofluoric Acid; Silanes
PubMed: 38281846
DOI: 10.1016/j.dental.2024.01.001 -
Medical Science Monitor : International... Dec 2023This systematic review aimed to identify and analyze in vitro studies on the marginal adaptation values of computer-aided-design/computer-aided-manufacturing (CAD/CAM)...
A Comparative Analysis of Marginal Adaptation Values between Lithium Disilicate Glass Ceramics and Zirconia-Reinforced Lithium Silicate Endocrowns: A Systematic Review of In Vitro Studies.
This systematic review aimed to identify and analyze in vitro studies on the marginal adaptation values of computer-aided-design/computer-aided-manufacturing (CAD/CAM) and heat-pressed lithium disilicate glass ceramics and zirconia-reinforced lithium silicates and endocrown restorations. A full literature search was conducted in Web of Science, PubMed/Medline, EMBASE, Scopus, Cochrane Library, Google Scholar, and ProQuest electronic databases. The following keywords: endocrown [(marginal adaption) or (marginal fit) or internal fitting)], endocrown [(molar(s)) or (premolar(s) or (posterior teeth) or (maxillary arch) or (mandibular arch)] and ceramic materials as [(lithium disilicate glass ceramic CAD/CAM) or (zirconia) or (heat-press)] were used. Articles were manually searched utilizing their reference lists. Study selection was restricted or limited to the time of publication but not to the type of tested teeth or ceramic material, endocrown design, system of endocrown construction, abutment scanning, and system of the marginal adaption measurement. A total of 17 in vitro studies published between 2016 and 2023 were included in this systemic review. Less than half of the studies were published during 2023. Most studies used lithium disilicate glass ceramic and zirconia-reinforced lithium silicate all-ceramic materials by CAD/CAM or heat-press systems. Marginal adaptation, or marginal gap, was almost equal in the 2 materials, while it was slightly or marginally higher in the heat-press than in the CAD/CAM system. All-ceramic lithium disilicate glass ceramic and/or zirconia endocrowns fabricated for posterior teeth in both arches using CAD/CAM or heat-press had recorded marginal adaptation values within an acceptable range.
Topics: Lithium; Materials Testing; Ceramics; Dental Porcelain; Silicates; Dental Prosthesis Design
PubMed: 38148601
DOI: 10.12659/MSM.942649 -
The Journal of Prosthetic Dentistry Aug 2023Because the use of zirconia in dentistry is relatively new, the number of published studies on the subject is scarce, even though material selection is an important... (Review)
Review
Evaluating the clinical behavior of veneered zirconia in comparison with monolithic zirconia complete arch implant-supported prostheses: A systematic review and meta-analysis.
STATEMENT OF PROBLEM
Because the use of zirconia in dentistry is relatively new, the number of published studies on the subject is scarce, even though material selection is an important factor in clinical performance. Therefore, a systematic assessment of the impact of the prosthetic material, framework design, veneering material, and manufacturing process is required.
PURPOSE
The purpose of this systematic review and meta-analysis was to investigate the survival and success rates of feldspathic porcelain veneered zirconia (VZir) in comparison with monolithic zirconia (MZir) complete arch implant-supported prostheses (CAISPs). A secondary objective was to assess the influence of the type of loading, the presence or absence of a cantilever, the type of zirconia used, the location, and the opposing arch on complications rates and patient satisfaction.
MATERIAL AND METHODS
An electronic search of the MEDLINE database (via PubMed), Scopus, Science Direct, Cochrane Library, and OpenGrey was carried out. The criteria described in the preferred reporting items for systematic reviews and meta-analyses statement were used. The search was restricted from January 2000 to January 2022.
RESULTS
The systematic search resulted in 20 articles that met the established criteria. In total, 751 patients (VZir=302; MZir=449) with 3038 CAISPs (VZir=368; MZir=2670) were analyzed. Higher prosthetic survival and success rates were found in MZir compared with VZir CAISPs (100% and 95.45%, respectively). The meta-analysis found significantly fewer complications related to MZir (9.4% [4.8%-14.1%]) compared with VZir (33.7% [17.5%-49.9%]).
CONCLUSIONS
Based on the findings of this systematic review, MZir CAISPs had higher survival and success rates than VZir CAISPs, with significantly fewer prosthetic complications. The influence of factors such as the type of functional loading, the presence of a cantilever, the material used in the prosthodontic workflow, the location of the CAISP, and the type of antagonist arch on the performance of Zir CAISPs remains unclear.
PubMed: 37696747
DOI: 10.1016/j.prosdent.2023.07.021 -
Clinical Oral Investigations Oct 2023To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia... (Review)
Review
Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis.
PURPOSE
To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia (PVZ) fixed dental prosthesis, based on a systematic literature review.
METHODS
An electronic search was performed in three databases, supplemented by hand searching. Several statistical methods were used.
RESULTS
Seventy-four publications reported 6370 restorations (4264 PVZ; 2106 MZ; 8200 abutment teeth; 3549 patients), followed up until 152 months. A total of 216 prostheses failed, and survival was statistically significant different between groups. PVZ had higher occurrence of complications than MZ; the difference was especially greater for either minor or major chipping. The difference in prevalence of either minor or major chipping was statistically significant for PVZ prostheses between cementation with glass ionomer and adhesive resin cement (higher), adhesive resin and resin-modified glass ionomer cement (RMGIC, higher), and between RMGIC (higher) and glass ionomer cement. For MZ the difference was significant only for minor chipping between RMGIC (higher) and adhesive resin cement. Abutment teeth to PVZ prostheses more often lost vitality. Decementation was not observed with RMGIC. Air abrasion did not seem to clinically decrease the decementation risk. The 5-year difference in the occurrence of minor or major chipping between MZ and PVZ prostheses was statistically significant, but nor for catastrophic fracture.
CONCLUSION
Tooth-supported PVZ prostheses present higher failure and complication rates than MZ prosthesis. The difference in complications is striking when it comes to chipping.
CLINICAL RELEVANCE
Awareness of the outcome differences between different types of zirconia prostheses is important for clinical practice.
PubMed: 37626273
DOI: 10.1007/s00784-023-05219-4 -
Clinical Oral Investigations Sep 2023The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
The aim of this systematic review and meta-analysis is to assess the comparative clinical success and survival of intracoronal indirect restorations using gold, lithium disilicate, leucite, and indirect composite materials.
MATERIAL AND METHODS
This systematic review and meta-analysis were conducted following the Cochrane Handbook for Systematic Reviews of Interventions and PRISMA guidelines. The protocol for this study was registered in PROSPERO (registration number: CRD42021233185). A comprehensive literature search was conducted across various databases and sources, including PubMed/Medline, Embase, Cochrane Library, Web of Science, ClinicalTrials.gov, and gray literature. A total of 7826 articles were screened on title and abstract. Articles were not excluded based on the vitality of teeth, the language of the study, or the observation period. The risk difference was utilized for the analyses, and a random-effects model was applied. All analyses were conducted with a 95% confidence interval (95% CI). The calculated risk differences were derived from the combined data on restoration survival and failures obtained from each individual article. The presence of heterogeneity was assessed using the I statistic, and if present, the heterogeneity of the data in the articles was evaluated using the non-parametric chi-squared statistic (p < 0.05).
RESULTS
A total of 12 eligible studies were selected, which included 946 restorations evaluated over a minimum observation period of 1 year and a maximum observation period of 7 years. Results of the meta-analysis indicated that intracoronal indirect resin composite restorations have an 18% higher rate of failure when compared to intracoronal gold restorations over 5-7 years of clinical service (risk difference = - 0.18 [95% CI: - 0.27, - 0.09]; p = .0002; I = 0%). The meta-analysis examining the disparity in survival rates between intracoronal gold and leucite restorations could not be carried out due to methodological differences in the studies.
CONCLUSIONS
According to the currently available evidence, medium-quality data indicates that lithium disilicate and indirect composite materials demonstrate comparable survival rates in short-term follow-up. Furthermore, intracoronal gold restorations showed significantly higher survival rates, making them a preferred option over intracoronal indirect resin-composite restorations. Besides that, the analysis revealed no statistically significant difference in survival rates between leucite and indirect composite restorations. The short observation period, limited number of eligible articles, and low sample size of the included studies were significant limitations.
CLINICAL SIGNIFICANCE
Bearing in mind the limitations of the reviewed literature, this systematic review and meta-analysis help clinicians make evidence-based decisions on how to restore biomechanically compromised posterior teeth.
Topics: Dental Porcelain; Aluminum Silicates; Composite Resins; Gold
PubMed: 37597003
DOI: 10.1007/s00784-023-05050-x -
Journal of Prosthodontic Research Jan 2024This study performed a systematic review to assess the biomechanical behavior of all-ceramic endowcrowns fabricated using computer-aided design and computer-aided...
PURPOSE
This study performed a systematic review to assess the biomechanical behavior of all-ceramic endowcrowns fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM) for the restoration of endodontically treated teeth.
STUDY SELECTION
Three electronic databases (PubMed, Web of Science, and Scopus) were searched by operators specializing in health sciences databases searches to answer the following focused question based on the Population, Intervention, Comparison, Outcome (PICO) format: "Whether all-ceramic CAD/CAM endocrowns (Intervention) used to restore human endodontically treated teeth (Population) exhibit superior fracture resistance (Outcome) compared to non-CAD/CAM all-ceramic or non-ceramic endocrowns (Comparison)." The methodological quality assessment was performed using previously conducted systematic reviews of in vitro studies. The outcomes were expressed as the mean ± the standard deviation (SD).
RESULTS
Seventeen in vitro studies were included. The materials used in these studies were lithium disilicate glass-ceramic, polymer-infiltrated ceramic, zirconia-reinforced lithium silicate glass-ceramic, resin/hybrid nanoceramics, zirconia-reinforced lithium silicate ceramics, and feldspathic ceramic. The fracture resistance of endocrowns using different ceramics varied as follows: (i) IPS e.max CAD (2863.62 ± 51.47 N), (ii) Vita Enamic (1952 ± 378 N), (iii) Vita Suprinity (1859 ± 588 N), (iv) Cerasmart (1981 ± 169.5 N), (v) LAVA Ultimate (2484 ± 464 N), (vi) Celtra Duo (1618.30 ± 585.00 N), and (vii) Cerec Blocs (236.29 ± 32.12 N).
CONCLUSIONS
CAD/CAM all-ceramic endocrowns can withstand occlusal forces in the posterior region. All-ceramic endocrowns improve the fracture strength of endodontically treated teeth. Lithium disilicate crowns were commonly and successfully used in the included studies. More in vitro investigations that implement uniformity in material and measurement approaches are required to strengthen the evidence currently available in the literature regarding the durability of all-ceramic endocrowns.
Topics: Humans; Ceramics; Computer-Aided Design; Crowns; Dental Porcelain; Lithium; Materials Testing; Silicates; Tooth, Nonvital; Zirconium
PubMed: 37286503
DOI: 10.2186/jpr.JPR_D_22_00296 -
Journal of Indian Prosthodontic Society 2023In the present era when interest in digital dentistry is increasing, the published literature is still confusing about whether digital impression provides similar... (Meta-Analysis)
Meta-Analysis
In the present era when interest in digital dentistry is increasing, the published literature is still confusing about whether digital impression provides similar accuracy as provided by a conventional impression for the fabrication of a single-unit ceramic crown. The aim of the study was to systematically review the in vivo studies comparing marginal, axial, and occlusal fit of single-unit ceramic crowns fabricated after digital impressions with the ones fabricated after conventional impressions. The PubMed, Scopus, and Cochrane online databases were searched for studies comparing the digital impression technique with the conventional technique for single-unit ceramic crowns. Data extraction was done for the year of publication, type of study, country, number of patients, impression system (intraoral scanner [IOS] or conventional impression), marginal fit, axial fit, and occlusal fit. Ten studies were included for meta-analysis regarding the discrepancy in marginal fit, axial fit, and occlusal fit. The digital impression proved to be better than the conventional impression. The mean difference for marginal fit was 6.54 μm (heterogeneity P < 0.00001, I = 93%), for axial fit 24.69 μm (heterogeneity P = 0.34, I = 11%), and for occlusal fit 6.99 μm (heterogeneity P = 0.03, I = 59%). The results of meta-analyses suggest that there is no significant difference between the impression systems (marginally favoring digital impression). The digital impression technique provided better marginal and internal fit of single-unit ceramic crowns than the conventional impression technique. The digital workflow using IOS provided a clinically acceptable marginal fit for single-unit crowns.
Topics: Humans; Computer-Aided Design; Crowns; Dental Impression Technique; Dental Marginal Adaptation; Dental Porcelain; Dental Prosthesis Design
PubMed: 37102534
DOI: 10.4103/jips.jips_534_22