-
Journal of Clinical Medicine Apr 2023Root resorption is one of the complications of orthodontic treatment, and has a varied and unclear aetiology. (Review)
Review
The Assessment of the Rank of Torque Control during Incisor Retraction and Its Impact on the Resorption of Maxillary Central Incisor Roots According to Incisive Canal Anatomy-Systematic Review.
BACKGROUND
Root resorption is one of the complications of orthodontic treatment, and has a varied and unclear aetiology.
OBJECTIVE
To evaluate the relationship between upper incisor resorption and contact with the incisive canal and the risk of resorption during orthodontic treatment associated with upper incisor retraction and torque control.
SEARCH METHODS
According to PRISMA guidelines, the main research question was defined in PICO. Scientific databases MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials were searched for linking keywords: Resorption of roots incisive canal, Resorption of roots nasopalatine canal, Incisive canal retraction and Nasopalatine canal retraction.
SELECTION CRITERIA
No time filters were applied due to the significantly limited number of studies. Publications in the English language were selected. Based on the information provided in the abstracts, articles were selected according to the following criteria: controlled clinical prospective trials and case reports. No randomised clinical trials (RCTs) or controlled clinical prospective trials (CCTs) were found. Articles unrelated to the topic of the planned study were excluded. The literature was reviewed, and the following journals were searched: American Journal of Orthodontics and Dentofacial Orthopedics, International Orthodontics, Journal of Clinical Orthodontics, Angle Orthodontist, Progress in Orthodontics, Orthodontics and Craniofacial Research, Journal of Orofacial Orthopedics, European Journal of Orthodontics and Korean Journal of Orthodontics.
DATA COLLECTION AND ANALYSIS
The articles were subjected to risk of bias and quality assessment using the ROBINS-I tool.
RESULTS
Four articles with a total of 164 participants were selected. In all studies, differences in root length were observed after contact with the incisive canal, which was statistically significant.
CONCLUSIONS AND IMPLICATIONS
The contact of incisor roots with the incisive canal increases the risk of resorption of these roots. IC anatomy should be considered in orthodontic diagnosis using 3D imaging. The risk of resorption complications can be reduced by appropriate planning of the movement and extent of the incisor roots (torque control) and the possible use of incisor brackets with built-in greater angulation. Registration CRD42022354125.
PubMed: 37109117
DOI: 10.3390/jcm12082774 -
Materials (Basel, Switzerland) Mar 2023Head and neck cancers are a significant global health burden, with radiation therapy being a frequently utilized treatment. The aim of this systematic review was to... (Review)
Review
Head and neck cancers are a significant global health burden, with radiation therapy being a frequently utilized treatment. The aim of this systematic review was to provide a critical appraisal of laboratory studies that assessed the effect of irradiation on the adhesive performance of resin-based biomaterials. The analysis included 23 laboratory studies obtained from five databases, with most studies using human enamel, dentin, or both, and bonding procedures involving the fabrication of direct restorations, standardized specimens, bonding of orthodontic brackets, and luting of endodontic fiber posts. The protocols used for irradiation varied, with most studies exposing specimens made from extracted teeth to irradiation using cabinet irradiators to simulate treatment of head and neck cancer. The findings indicate that irradiation reduces the bond strength of dental adhesives and resin-based composites on flat, ground enamel and dentin specimens, with different adhesives and timing of irradiation having a significant impact on adhesive performance. Irradiation also increased microleakage in most studies. The effect of irradiation on marginal adaptation of direct resin-based composite restorations was inconclusive. This systematic review indicates that irradiation has detrimental effects on the adhesive performance of resin-based biomaterials and highlights the need for further clinical and laboratory studies evaluating the performance of adhesive materials and approaches to improve it.
PubMed: 37048873
DOI: 10.3390/ma16072580 -
Cureus Dec 2022This review aimed to evaluate the effectiveness of using one or more acceleration methods with self-ligating brackets to accelerate orthodontic tooth movement in adults... (Review)
Review
This review aimed to evaluate the effectiveness of using one or more acceleration methods with self-ligating brackets to accelerate orthodontic tooth movement in adults and the associated effects of these interventions. An electronic search of the following databases (PubMed, Scopus, Google Scholar, EMBASE) was performed (From January 1990 to November 2021). ClinicalTrials.gov and the International Clinical Trials Registry Platform were also electronically searched to find any unpublished studies and ongoing trials. The selected randomized controlled trials (RCTs) involved adult patients treated using self-ligating brackets combined with one or more acceleration methods compared with self-ligating brackets or conditional brackets alone. The risk of bias was assessed using Cochrane's risk of bias tool. A total of seven RCTs and one controlled clinical trial (CCT) were included in this review. Combining self-ligating brackets with flapless corticotomy, low-level laser therapy (LLLT), and infrared light accelerated orthodontic movement by 43% and 50% for surgical methods, 20-50% for LLLT, and 22% for infrared light. Regarding side effects on periodontal tissues, neither flapless corticotomy nor low-frequency vibrational forces caused any damage. Combining self-ligating brackets and flapless corticotomy, low-level laser, or infrared light effectively accelerated orthodontic movement by 20% to 50 %. In contrast, the combination of self-ligating brackets with vibrational forces did not affect speeding tooth movement. The acceleration methods did not have any side effects on the periodontal tissues, but the available evidence was insufficient. There is a need for further primary research regarding the effectiveness of combining self-ligating brackets with acceleration methods and the possible untoward side effects.
PubMed: 36578856
DOI: 10.7759/cureus.32879 -
European Journal of Orthodontics Mar 2023Bracket failure increases the treatment time of orthodontic therapy and burdens patients with unnecessary costs, increased chair time, and possible new appointments. (Meta-Analysis)
Meta-Analysis
BACKGROUND
Bracket failure increases the treatment time of orthodontic therapy and burdens patients with unnecessary costs, increased chair time, and possible new appointments.
OBJECTIVE
To compare the bond failures of different orthodontic materials based on the results of available clinical studies.
SEARCH METHODS
A systematic search of clinical trials was performed in the Cochrane, Embase, and Pubmed databases with no limitations. The list of investigated techniques contained conventional acid-etch primer (CM-AEP), self-etch primer (SEP), self-cure resin (SCR), and simple or resin-modified glass ionomer (RM-GIC) materials and procedures.
SELECTION CRITERIA
Clinical studies reporting the failure rate of bonded brackets after using direct adhesive techniques on buccal sites of healthy teeth were included.
DATA COLLECTION AND ANALYSIS
Bracket failure rates from eligible studies were extracted by two authors independently. Risk ratios (RRs) were pooled using the random-effects model with DerSimonian-Laird estimation.
RESULTS
Thirty-four publications, involving 1221 patients, were included. Our meta-analysis revealed no significant difference in the risk of bracket failures between SEP and CM-AEP. After 6, 12, and 18 months of bonding, the values of RR were 1.04 [95% confidence interval (CI), 0.67-1.61], 1.37 (95% CI, 0.98-1.92), and 0.93 (95% CI, 0.72-1.20), respectively. At 18 months, bracket failure was 4.9 and 5.2% for SEP and CM-AEP, respectively. Heterogeneity was good or moderate (I2 < 42.2%). The results of RM-GIC at 12 months indicated a 57% lower risk of bracket failure using SCR as compared with RM-GIC (RR: 0.38; 95% CI, 0.24-0.61). At 18 months, bracket failures for SCR and RM-GIC were 15.8 and 36.6%, respectively (RR: 0.44; 95% CI, 0.37-0.52, I2 = 78.9%), demonstrating three to six times higher failure rate than in the case of etching primer applications.
LIMITATIONS
A major limitation of the present work is that the included clinical trials, with no exceptions, showed variable levels of risk of bias. Another possible problem affecting the outcome is the difference between the clustering effects of the split mouth and the parallel group bracket allocation methods.
CONCLUSIONS AND IMPLICATIONS
The results revealed no significant difference between SEP and CM-AEP up to 18 months after application. RM-GIC had much worse failure rates than acid-etching methods; additionally, the superiority of SCR over RM-GIC was evident, indicating strong clinical relevance.
REGISTRATION
Prospero with CRD42020163362.
Topics: Humans; Time Factors; Dental Bonding; Orthodontic Brackets; Resin Cements
PubMed: 36222731
DOI: 10.1093/ejo/cjac050 -
Dental and Medical Problems 2022External apical root resorption (EARR) is a serious complication that should be avoided during orthodontic treatment; this pathology depends on multiple factors. Data... (Meta-Analysis)
Meta-Analysis Review
External apical root resorption (EARR) is a serious complication that should be avoided during orthodontic treatment; this pathology depends on multiple factors. Data from clinical studies should be assessed to determine the influence these factors have on the development of EARR. This systematic review aims to compare EARR produced by different factors (orthodontic systems, dental trauma, and dental vitality). The protocol was registered on the PROSPERO database. The search was performed on 5 databases. Accepted study designs included randomized controlled trials, nonrandomized clinical trials, and observational studies. Full-text articles from clinical studies of EARR associated with orthodontic treatment in English, Spanish, or Portuguese with no publication date restrictions were selected. Data from the studies, such as age, population, study groups, and outcome measures, were recorded. Multiple meta-analyses were performed with data from the included studies. Evidence suggests that EARR induced by orthodontic treatment is similar, regardless of the technique used. Evidence of the effect of previous dental trauma on EARR during orthodontic treatment is limited. There is less EARR associated with orthodontic treatment in endodontically treated teeth than in vital teeth. These conclusions should be considered with caution due to the low certainty of the evidence.
Topics: Humans; Orthodontic Appliances, Fixed; Root Resorption; Tooth, Nonvital; Clinical Trials as Topic
PubMed: 36206494
DOI: 10.17219/dmp/145369 -
Orthodontic bracket bonding techniques and adhesion failures: A systematic review and meta-analysis.Journal of Clinical and Experimental... Sep 2022This systematic review compared the bonding failures of orthodontic brackets bonded by indirect or direct techniques. Data sources: The searched databases were Cochrane... (Review)
Review
BACKGROUND
This systematic review compared the bonding failures of orthodontic brackets bonded by indirect or direct techniques. Data sources: The searched databases were Cochrane Library, LILACS, BBO, PubMed, Scopus, Web of Science.
MATERIAL AND METHODS
A search for randomized clinical trials comparing the two techniques was carried out to answer the research question: When considering orthodontic bracket bonding on permanent teeth, does the indirect technique reduce the number of bonding failures compared to the direct one over time? The quality of the included papers was assessed with Cochrane risk of bias tool and the quality of evidence with GRADE.
RESULTS
From 3096 articles identified, seven were included in the systematic review (five at unclear; two at low risk of bias). Meta-analysis was carried out according to the follow-up periods (0-6 months and 12-15 months).
RESULTS
In the first period, bonding techniques were similar with regard to adhesion failures (RR = 0.59; 95% CI 0.10-3.62; = 0.00001; I2 = 92%); in the 12-to-15-month period, the direct bonding technique proved to be superior (RR = 1.44; 95% CI 1.05 - 1.99; = 0.41; I2 = 0%). The quality of evidence was classified as low for the 0-6 months follow-up and high for the 12 months.
CONCLUSIONS
Based on the absence of heterogeneity and the high quality of evidence, it is concluded that the direct bracket bonding technique has a lower failure rate than the indirect technique in the long term (12-15 months). Orthodontic brackets, fixed orthodontics, systematic review.
PubMed: 36158772
DOI: 10.4317/jced.59768 -
BDJ Open Sep 2022The COVID-19 pandemic has caused major disruptions in dental care globally, in part due to the potential for contaminated aerosol to be generated by dental activities....
INTRODUCTION
The COVID-19 pandemic has caused major disruptions in dental care globally, in part due to the potential for contaminated aerosol to be generated by dental activities. This systematic review assesses the literature for changes in aerosol-contamination levels when rotary instruments are used, (1) as distance increases from patient's mouth; (2) as time passes after the procedure; and (3) when using different types of handpieces.
METHODS
The review methods and reporting are in line with PRISMA statements. A structured search was conducted over five platforms (September 2021). Studies were assessed independently by two reviewers. To be eligible studies had to assess changes in levels of aerosol contamination over different distances, and time points, with rotary hand instruments. Studies' methodologies and the sensitivity of the contamination-measurement approaches were evaluated. Results are presented descriptively.
RESULTS
From 422 papers identified, 23 studies were eligible. All investigated restorative procedures using rotary instruments and one study additionally looked at orthodontic bracket adhesive material removal. The results suggest contamination is significantly reduced over time and distance. However, for almost all studies that investigated these two factors, the sizes of the contaminated particles were not considered, and there were inconclusive findings regarding whether electric-driven handpieces generate lower levels of contaminated particles.
CONCLUSION
Aerosol contamination levels reduce as distances, and post-procedure times increase. However, there was sparce and inconsistent evidence on the clearing time and no conclusions could be drawn. High-speed handpieces produce significantly higher levels of contamination than slow-speed ones, and to a lesser extent, micro-motor handpieces. However, when micro-motor handpieces were used with water, the contamination levels rose and were similar to high-speed handpiece contamination levels.
PubMed: 36068221
DOI: 10.1038/s41405-022-00118-4 -
International Journal of Environmental... Jul 2022One of the risks that we find after orthodontic treatment is the secondary appearance of white spot lesions (WLS) after the removal of fixed multi-bracket appliances.... (Meta-Analysis)
Meta-Analysis Review
Changes in the Color and Brightness of White Spots Associated with Orthodontic Treatment 6 Months after the Application of Infiltrative Resins: Systematic Review and Meta-Analysis.
One of the risks that we find after orthodontic treatment is the secondary appearance of white spot lesions (WLS) after the removal of fixed multi-bracket appliances. Today, there are several treatment methods, resin infiltration being the most used in the most serious cases. The objective of this study is to carry out a systematic review and meta-analysis to determine the efficacy and stability in the variables of color and gloss, six months after resin infiltration. A comprehensive search was performed in the following databases: PubMed, Embase, Google Scholar, Scopus, Medline, and Web of Science. Articles published in the last 10 years were selected, including in vivo studies with a six-month follow-up. PRISMA guidelines were followed to carry out this systematic review. All studies where the application of resin was performed on carious lesions were discarded. Once the inclusion and exclusion criteria were applied, a final sample of four articles was obtained, on which the review and meta-analysis were carried out. Once examined, all authors considered that there was an immediate improvement in both variables. However, statistically significant differences were obtained in the color change outcome, but not in the brightness outcome in the subgroup analysis after six months of icon resin infiltration.
Topics: Color; Dental Caries; Diagnosis, Oral; Humans; MEDLINE; Orthodontic Appliances, Fixed; PubMed
PubMed: 35954634
DOI: 10.3390/ijerph19159277 -
BMC Oral Health Jul 2022Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also...
BACKGROUND
Before the magnetic resonance imaging (MRI) examination fixed orthodontic devices, such as brackets and wires, cause challenges not only for the orthodontist but also for the radiologist. Essentially, the MRI-safe scan of the fixed orthodontic tools requires a proper guideline in clinical practice. Therefore, this systematic review aimed to examine all aspects of MRI-safe scan, including artifact, thermal, and debonding effects, to identify any existing gaps in knowledge in this regard and develop an evidence-based protocol.
METHODS
The Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement was used in this study. The clinical question in "PIO" format was: "Does MRI examination influence the temperature of the orthodontic devices, the size of artifacts, and the debonding force in patients who have fixed orthodontic bracket and/or wire?" The search process was carried out in PubMed, PubMed Central, Scopus, and Google Scholar databases. The search resulted in 1310 articles. After selection according to the eligibility criteria, 18 studies were analyzed by two reviewers. The risk of bias was determined using the Quality In Prognosis Studies tool.
RESULTS
Out of the eligible 18 studies, 10 articles examined the heating effect, 6 were about the debonding effect, and 11 measured the size of artifact regarding brackets and wires. Considering the quality assessment, the overall levels of evidence were high and medium. The published studies showed that heating and debonding effects during MRI exposure were not hazardous for patients. As some wires revealed higher temperature changes, it is suggested to remove the wire or insert a spacer between the appliances and the oral mucosa. Based on the material, ceramic and plastic brackets caused no relevant artifact and were MRI-safe. Stainless steel brackets and wires resulted in susceptibility artifacts in the orofacial region and could cause distortion in the frontal lobe, orbits, and pituitary gland. The retainer wires showed no relevant artifact.
CONCLUSIONS
In conclusion, the thermal and debonding effects of the fixed orthodontic brackets and wires were irrelevant or resoluble; however, the size of the artifacts was clinically relevant and determined most significantly the feasibility of fixed brackets and wires in MRI examination.
Topics: Artifacts; Humans; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires; Stainless Steel
PubMed: 35854295
DOI: 10.1186/s12903-022-02317-9 -
Journal of Orthodontic Science 2022This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at... (Review)
Review
This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at bracket--wire interface. Electronic database searches were performed up to September 2020. studies were considered for reviewing process. Study selection, data extraction, risk of bias assessment was performed during reviewing process. Only qualitative analyses of included literature were done due to the presence of heterogeneity among the studies. Out of 1,068 retrieved records, nine studies satisfied the inclusion criteria and included in this review. Studies were assessed at low risk to high risk of bias according to certain parameters. Wide variety of nanoparticles were used for surface coating of orthodontic wires of variable sizes, shapes, and materials like stainless steel, NiTi, and TMA and placed into the slots of different types of orthodontic brackets to evaluate the alteration in frictional and other mechanical properties. Most of the studies clearly indicate that coating with nanoparticles decreases the friction between wire and bracket interface under specified conditions. Furthermore, among the nine included studies, only two considered evaluation of effect of coated brackets on frictional and other mechanical properties and results were heterogeneous. The null hypothesis is rejected and it is concluded that the wires coated with nanoparticles might offer a novel opportunity to substantially reduce frictional resistance at bracket--wire interface during tooth movement. Further studies are necessary to strengthen the evidence regarding effect of coated brackets on frictional properties.
PubMed: 35754415
DOI: 10.4103/jos.jos_152_21