-
Sensors (Basel, Switzerland) Jun 2024Traditional motion analysis systems are impractical for widespread screening of non-contact anterior cruciate ligament (ACL) injury risk. The Kinect V2 has been... (Comparative Study)
Comparative Study
Traditional motion analysis systems are impractical for widespread screening of non-contact anterior cruciate ligament (ACL) injury risk. The Kinect V2 has been identified as a portable and reliable alternative but was replaced by the Azure Kinect. We hypothesize that the Azure Kinect will assess drop vertical jump (DVJ) parameters associated with ACL injury risk with similar accuracy to its predecessor, the Kinect V2. Sixty-nine participants performed DVJs while being recorded by both the Azure Kinect and the Kinect V2 simultaneously. Our software analyzed the data to identify initial coronal, peak coronal, and peak sagittal knee angles. Agreement between the two systems was evaluated using the intraclass correlation coefficient (ICC). There was poor agreement between the Azure Kinect and the Kinect V2 for initial and peak coronal angles (ICC values ranging from 0.135 to 0.446), and moderate agreement for peak sagittal angles (ICC = 0.608, 0.655 for left and right knees, respectively). At this point in time, the Azure Kinect system is not a reliable successor to the Kinect V2 system for assessment of initial coronal, peak coronal, and peak sagittal angles during a DVJ, despite demonstrating superior tracking of continuous knee angles. Alternative motion analysis systems should be explored.
Topics: Humans; Male; Female; Adult; Anterior Cruciate Ligament Injuries; Biomechanical Phenomena; Young Adult; Movement; Knee Joint; Range of Motion, Articular; Software
PubMed: 38931598
DOI: 10.3390/s24123814 -
International Journal of Molecular... Jun 2024Angiogenesis and vascular endothelial growth factor (VEGF) are involved in osteoarthritis (OA). We previously reported the inhibitory effect of bevacizumab in a rabbit...
Angiogenesis and vascular endothelial growth factor (VEGF) are involved in osteoarthritis (OA). We previously reported the inhibitory effect of bevacizumab in a rabbit model of OA. In the current study, we investigated the effects of lenvatinib, an angiogenesis inhibitor targeting the VEGF and fibroblast growth factor receptors, on synovitis, osteophyte formation, and cartilage degeneration in a rabbit OA model. Posttraumatic OA was induced by anterior cruciate ligament transection (ACLT) on one knee of each rabbit. Rabbits were placed into four groups according to the following lenvatinib doses: untreated control ( = 12), L0.3: 0.3 mg/kg/day ( = 15), L1.0: 1.0 mg/kg/day ( = 14), and L3.0: 3.0 mg/kg/day ( = 13) groups. We evaluated limb pain using the weight distribution ratio measured with an incapacitance tester, macroscopic osteophyte formation, and femoral condyle synovium and cartilage histology. For cartilage evaluation, the following distal sites of the femur were evaluated separately: femoral-tibial (FT), femoral-patellar (FP), and femoral corner (between FP and FT). The weight distribution ratio at 12 weeks after surgery was higher in the L0.3 and L1.0 groups than in the control group. Osteophyte formation and synovitis scores were significantly lower in the L0.3, L1.0, and L3.0 groups than in the control group. The Osteoarthritis Research Society International scores of the FT, corner, and FP sites in the L0.3 group were lower than in the control group. The cartilage thickness ratio at the FT and corner sites was significantly lower in the L0.3 group than in the control group. Krenn's grading system of cartilage synovitis showed that all lenvatinib-administered groups had significantly lower scores than the control group. MMP3 expression level in cartilage tissue was significantly lower in the L3.0 group compared with the other three groups. ADAMTS5 expression was lower in the L3.0 group compared with the control and L0.3 groups. Oral administration of lenvatinib inhibited synovitis, osteophyte formation, and cartilage degeneration and reduced pain in a rabbit ACLT model. Lenvatinib is an oral VEGF inhibitor that is easier to administer than other VEGF inhibitors and may have potential as a treatment of posttraumatic OA.
Topics: Animals; Rabbits; Quinolines; Phenylurea Compounds; Osteoarthritis, Knee; Protein Kinase Inhibitors; Disease Models, Animal; Male; Synovitis; Cartilage, Articular; Osteophyte; Tyrosine Kinase Inhibitors
PubMed: 38928219
DOI: 10.3390/ijms25126514 -
The Iowa Orthopaedic Journal 2024Posterior cruciate ligament (PCL) tears in young children are rare and optimal treatment is poorly described. Diagnosis may prove challenging as young children may not... (Review)
Review
BACKGROUND
Posterior cruciate ligament (PCL) tears in young children are rare and optimal treatment is poorly described. Diagnosis may prove challenging as young children may not be able to verbalize a complete history of injury, may be difficult to examine, and plane film radiographs often appear within normal limits. Surgical treatment carries a risk of physeal arrest, but non-operative treatment may lead to recurrent instability and pain.
METHODS
We present a case report of a fouryear- old child with a PCL avulsion off the femoral insertion who received an open reduction and internal fixation (ORIF) with combined arthroscopic synovial debridement. We performed a literature review which compared the mechanism, location, concomitant injuries, work up and management of PCL injuries in children under the age of ten compared to adolescents and adults.
RESULTS
Nineteen months following surgery, physical examination revealed full knee range of motion and return to baseline function. Imaging studies confirmed there was no evidence of physeal arrest.
CONCLUSION
ORIF with arthroscopy can be an effective method to treat PCL avulsions in children under the age of 10 years. This is similar to other case reports which reported positive outcomes with ORIF in this population. Large studies are needed to best understand optimal treatment modalities for PCL injuries in very young children. .
Topics: Humans; Posterior Cruciate Ligament; Arthroscopy; Child, Preschool; Male; Debridement; Knee Injuries; Range of Motion, Articular; Treatment Outcome; Fracture Fixation, Internal; Female
PubMed: 38919372
DOI: No ID Found -
The Iowa Orthopaedic Journal 2024The aim of this case report is to present a case of chronic cervical ligament tear and instability, which occurred by an unusual work injury with an...
BACKGROUND
The aim of this case report is to present a case of chronic cervical ligament tear and instability, which occurred by an unusual work injury with an eversion/hyper-pronation mechanism in contrast to the usual mechanism of inversion. The ligament was reconstructed using an allograft with satisfactory results up to 30 months after surgery. A new magnetic resonance imaging protocol (MRI) was developed to better evaluate the cervical ligament/graft.
CONCLUSION
In diagnosis of foot sprains, a specific ligament injury should always be sought. In this case, physical examination producing tenderness at the location of the cervical ligament and correlating this with an oblique intercolumn stress test that reproduced pain with apprehension and gross instability supported the diagnosis. Retrospectively applying anatomic knowledge to the earlier MRI findings of bone marrow edema at the insertion points of the cervical ligament on the talus and calcaneus was important in confirming the diagnosis. To better evaluate the cervical ligament allograft tendon reconstruction, a novel volumetric MRI sequence was developed which may prove helpful to also diagnose cervical ligament injuries in future cases. Anatomic reconstruction of the cervical ligament provided satisfactory clinical and radiographic results at 30-month follow-up. V.
Topics: Humans; Magnetic Resonance Imaging; Ligaments, Articular; Rupture; Plastic Surgery Procedures; Male; Adult; Female; Treatment Outcome; Joint Instability; Cervical Vertebrae
PubMed: 38919347
DOI: No ID Found -
PloS One 2024This observational study aimed to evaluate the intra- and inter-operator reliability of a digital palpation device in measuring compressive stiffness of the patellar... (Observational Study)
Observational Study
This observational study aimed to evaluate the intra- and inter-operator reliability of a digital palpation device in measuring compressive stiffness of the patellar tendon at different knee angles in talent and elite volleyball players. Second aim was to examine differences in reliability when measuring at different knee angles, between dominant and non-dominant knees, between sexes, and with age. Two operators measured stiffness at the midpoint of the patellar tendon in 45 Dutch volleyball players at 0°, 45° and 90° knee flexion, on both the dominant and non-dominant side. We found excellent intra-operator reliability (ICC>0.979). For inter-operator reliability, significant differences were found in stiffness measured between operators (p<0.007). The coefficient of variance significantly decreased with increasing knee flexion (2.27% at 0°, 1.65% at 45° and 1.20% at 90°, p<0.001). In conclusion, the device appeared to be reliable when measuring compressive stiffness of the patellar tendon in elite volleyball players, especially at 90° knee flexion. Inter-operator reliability appeared to be questionable. More standardized positioning and measurement protocols seem necessary.
Topics: Humans; Volleyball; Male; Female; Patellar Ligament; Palpation; Reproducibility of Results; Young Adult; Adult; Range of Motion, Articular; Knee Joint; Adolescent; Biomechanical Phenomena; Observer Variation
PubMed: 38917106
DOI: 10.1371/journal.pone.0304743 -
Revista Brasileira de Ortopedia Jun 2024To evaluate if there is a significant difference in the outcomes of isolated anterior cruciate ligament (ACL) reconstruction in patients with or without associated...
To evaluate if there is a significant difference in the outcomes of isolated anterior cruciate ligament (ACL) reconstruction in patients with or without associated anterolateral ligament (ALL) injury. We conducted a retrospective cross-sectional study through the analysis of medical records and the application of the questionnaires of the Lysholm Knee Scoring Scale and the International Knee Documentation Committee (IKDC) Subjective Knee Form to patients undergoing isolated ACL reconstruction. The 52 participants included were divided into two groups: 19 with associated ALL injury and 33 with no associated ALL injury. None of the patients with associated ALL injury suffered an ACL rerupture, and 21.1% presented injuries to other knee structures after surgery. Among the patients with no associated injury, 6.1% suffered ACL rerupture, and 18.2% presented injuries to other structures after surgery ( = 0.544). Return to activities at the same level as that of the preoperative period occurred in 60% of the patients with associated ALL injury and in 72% of those with no associated injury ( = 0.309). The mean score on the Lysholm Knee Scoring Scale was of 81.6 points in patients with associated ALL injury, and of 90.1 in those with no associated injury ( = 0.032). The mean score on the IKDC Subjective Knee Form was of 70.3 points in patients with associated ALL injury and of 76.7 in those with no associated injury ( = 0.112). There was no statistically significant difference regarding graft injuries or new injuries to other structures, satisfaction with the operated knee, or the score on the IKDC Subjective Knee Form. Return to activity was similar in the groups with and without associated ALL injuries. The scores on the Lysholm Knee Scoring Scale were better, with a statistically significant difference in the group with no associated ALL injuries.
PubMed: 38911889
DOI: 10.1055/s-0044-1785516 -
PloS One 2024Anterior cruciate ligament (ACL) tear is common in military setting; such an injury increase institutional costs and workforce strain, however, few studies have...
BACKGROUND
Anterior cruciate ligament (ACL) tear is common in military setting; such an injury increase institutional costs and workforce strain, however, few studies have investigated the mechanism and associated factors of ACL tear specifically in a military setting. The aim of this study was to investigate the prevalence and mechanisms of ACL tears in military personnel at a military referral hospital in Iran.
MATERIAL AND METHODS
This cross-sectional study examined 402 military personnel who presented with knee complaints at a single referral Iranian military hospital. The ACL injury prevalence and mechanisms were assessed by physical examination, medical records, and magnetic resonance imaging (MRI) of the knee. Data were collected by an orthopedic resident.
RESULTS
Of the total 402 patients, 285 were diagnosed with ACL tears; the prevalence was 70.9%. The most common mechanism leading to ACL tear was noncontact events. The knee changing direction-knee pivoting (54%) was the most frequent lower limb status, followed by a fall with the knee in valgus position (20.7%). The most commonly associated activity was military training (63.9%) and sports activities (32.6%). The incidence of ACL injuries was higher in soldiers compared with officers during military training, but higher in officers during sports exercises (P = 0.002). Common associated injuries involved the knee meniscus and cartilage.
CONCLUSION
The findings support those of previous studies, that in military personnel, the most common knee injury is damage to the ACL, most frequently through noncontact events, specifically knee pivoting, during military activities rather than sports and among soldiers. These findings help develop ACL injury prevention programs.
Topics: Humans; Military Personnel; Iran; Cross-Sectional Studies; Male; Anterior Cruciate Ligament Injuries; Adult; Prevalence; Female; Young Adult; Magnetic Resonance Imaging; Anterior Cruciate Ligament
PubMed: 38905203
DOI: 10.1371/journal.pone.0303326 -
JBJS Essential Surgical Techniques 2024A number of techniques have been described to enter the capsule and gain access to the hip joint during hip arthroscopy. Among these, the interportal and T-capsulotomies...
BACKGROUND
A number of techniques have been described to enter the capsule and gain access to the hip joint during hip arthroscopy. Among these, the interportal and T-capsulotomies are the most commonly utilized; however, these approaches transect the iliofemoral ligament, which normally resists anterior subluxation and stabilizes extension. Thus, these approaches may introduce capsuloligamentous instability and have been associated with complications such as dislocation, postoperative pain, microinstability, seroma, and heterotopic ossification. Although prior literature has demonstrated durable mid-term results for patients undergoing capsulotomies with capsular closure, avoidance of iatrogenic injury to the hip capsule altogether is preferable. Thus, the puncture capsulotomy technique we present is minimally invasive, preserves the biomechanics of the hip joint and capsule without disrupting the iliofemoral ligament, and allows for appropriate visualization of the joint through placement of multiple small portals.
DESCRIPTION
Following induction of anesthesia and with the patient supine on a hip traction table, the nonoperative leg is positioned at 45° abduction with support of a well-padded perineal post, and the operative hip is placed into valgus against the post. Intra-articular fluid distention with normal saline solution is utilized to achieve approximately 9 mm of inferior migration of the femoral head and decrease risk of iatrogenic nerve injury. Then, under fluoroscopic guidance, an anterolateral portal is created 1 cm anterior and 1 cm superior to the greater trochanter at an approximately 15° to 20° angle. Second, via arthroscopic visualization, the anterior portal is created 1 cm distal and 1 cm lateral to the intersection of a vertical line drawn at the anterior superior iliac spine and a horizontal line at the level of the anterolateral portal. Third, equidistant between the anterior and anterolateral portals, the mid-anterior portal is created distally. Finally, at one-third of the distance between the anterior superior iliac spine and the anterolateral portal, the Dienst portal is created. Thus, these 4 portals form a quadrilateral arrangement through which puncture capsulotomy can be performed.
ALTERNATIVES
Alternative approaches to the hip capsule include interportal and T-capsulotomies, with or without capsular closure. Although the most frequently utilized, these approaches transect the iliofemoral ligament and thus may introduce capsuloligamentous instability.
RATIONALE
The puncture capsulotomy technique has the advantage of maintaining the integrity of the capsule through the placement of 4 small portals. The technique does not transect the iliofemoral ligament and thus does not introduce capsuloligamentous instability. Furthermore, although good mid-term outcomes have been reported with capsular closure, the present technique avoids creating unnecessary injury to the capsule and complications of an unrepaired capsule or, conversely, of plication.
EXPECTED OUTCOMES
Patients who underwent the puncture capsulotomy technique showed significant improvements in multiple functional outcome scores at a mean follow-up of 30.4 months, including the International Hip Outcome Tool (iHOT-33) (39.6 preoperatively to 76.1 postoperatively), Hip Outcome Score-Activities of Daily Living subscale (HOS-ADL) (70.0 to 89.3), HOS Sport-Specific Subscale (HOS-SSS) (41.8 to 75.7), and modified Harris hip score (mHHS) (60.1 to 84.9). At 2 years postoperatively with respect to iHOT-33, 81.0% of patients achieved the minimal clinically important difference, 62.0% achieved the patient acceptable symptom state, and 58.9% achieved substantial clinical benefit. In addition, mean visual analog scale pain scores improved significantly over the follow-up period (6.3 to 2.2; p < 0.001). Finally, there were zero occurrences of infection, osteonecrosis of the femoral head, dislocation or instability, or femoral neck fracture in patients treated with puncture capsulotomy.
IMPORTANT TIPS
Anterolateral portal placement should be performed using the intra-articular fluid distention technique with fluoroscopy to avoid risk of iatrogenic labral damage and distraction-induced neurapraxia. Subsequent portals must then be placed under direct arthroscopic visualization.On establishment of the anterolateral portal, the scope should be switched to the anterior portal to ensure that the anterolateral portal has not been placed through the labrum and to adjust its placement to better access pathology. This portal, as well as all others, may be subsequently modified by adjusting the angle of the cannula, without making a new skin incision.If a cam lesion is located more anteromedially or posterolaterally, an additional accessory portal may be made distal or proximal to the anterolateral portal, respectively, in order to enhance visualization.Intermittent traction is utilized throughout the surgery. No traction is utilized during preparing and draping, suture tensioning and tie-down, and femoroplasty, with minimal traction during acetabuloplasty; these precautions serve to prevent iatrogenic superficial peroneal nerve injury.There can be a steep learning curve for this technique. In particular, greater surgical experience is required to perform adequate femoral osteoplasty for large cam lesions with this approach.Instrument maneuverability and visualization can be somewhat constrained with this approach.It is more difficult to perform certain procedures with this technique, including segmental and circumferential labral reconstructions, particularly with remote grafts.
ACRONYMS AND ABBREVIATIONS
iHOT-33 = International Hip Outcome Tool-33HOS-ADL = Hip Outcome Score-Activities of Daily Living subscaleHOS-SSS = Hip Outcome Score-Sport-Specific SubscaleAP = anteroposteriorMRA = magnetic resonance arthrogramMRI = magnetic resonance imagingCT = computed tomographyASIS = anterior superior iliac spinemHHS = modified Harris hip score.
PubMed: 38903605
DOI: 10.2106/JBJS.ST.23.00061 -
Danish Medical Journal Jun 2024In orthopaedics, anterior cruciate ligament (ACL) reconstructions are among the most common surgical interventions. Two methods are preferably used: autografts from the... (Meta-Analysis)
Meta-Analysis
INTRODUCTION
In orthopaedics, anterior cruciate ligament (ACL) reconstructions are among the most common surgical interventions. Two methods are preferably used: autografts from the hamstring tendon (HT) or patella tendon (PT). The purpose of this meta-analysis was to compare these two methods when returning to sports.
METHODS
Eleven studies were included based on a literature search conducted in PubMed. The primary outcome was return to preinjury sport level in athletes. Post-operative results such as the Lysholm score, the International Knee Documentation Committee (IKDC) subjective score, the Tegner Activity Score and KT-1000 arthrometry and autograft re-rupture rates were analysed as secondary outcomes.
RESULTS
The analysis showed no significant difference in return to preinjury sports level at a two-year follow-up between patients operated with hamstring or patella autograft. Considering the secondary outcomes, no significant differences were recorded in Lysholm score, IKDC score or re-rupture rate. The Tegner Activity Scale demonstrated a significantly higher activity level in the PT group than in the HT group (OR 0.79, p = 0.003). At the two-year follow-up, the KT-1000 arthrometer analysis also showed a significant difference in laxity, which was higher for the HT autografts (OR -0.31, p = 0.02).
CONCLUSION
This study showed no significant differences between hamstring and patella autografts. Even so, the choice of method when operated for ACL rupture remains crucial for the individual and should be a weighted decision made jointly by the patient and the physician.
Topics: Humans; Return to Sport; Anterior Cruciate Ligament Reconstruction; Hamstring Tendons; Patellar Ligament; Anterior Cruciate Ligament Injuries; Autografts; Transplantation, Autologous; Treatment Outcome
PubMed: 38903025
DOI: 10.61409/A09230599 -
BMC Musculoskeletal Disorders Jun 2024This study aimed to investigate the feasibility and precision of using a 3D-printed template for femoral tunnel placement in guiding the optimal positioning of the... (Comparative Study)
Comparative Study
A comparative study on 3D printing-assisted arthroscopic IDEAL point femoral tunnel positioning for anterior cruciate ligament reconstruction versus conventional arthroscopic positioning.
BACKGROUND
This study aimed to investigate the feasibility and precision of using a 3D-printed template for femoral tunnel placement in guiding the optimal positioning of the Internal anatomical stop and Low tension maintenance (IDEAL) bone tunnel during single-bundle anterior cruciate ligament (ACL) reconstruction.
METHODS
A retrospective analysis was conducted on 40 patients who underwent arthroscopic single-bundle ACL reconstruction at our hospital between April 2021 and November 2021. In the direct vision group, the IDEAL bone tunnel was positioned using radiofrequency localization directly visualized at the stump. In the 3D-printed positioning group, preoperative CT scans and Digital Imaging and Communications in Medicine (DICOM) data were employed. Following the Quadrant method by Bernard, the femoral tunnel's depth was set at 25% and its height at 29%. Postoperative plain CT scans enabled the reconstruction of 3D models for both groups. The accuracy of femoral tunnel placement was then compared.
RESULTS
The central locations of the bone tunnels in the direct vision group were at a mean depth of 25.74 ± 1.84% and a height of 29.22 ± 2.97%. In the 3D printing localization group, these values were 25.39 ± 2.98% for depth and 28.89 ± 2.50% for height, respectively. No significant differences were found in tunnel positioning between the groups. Both groups demonstrated statistically significant improvements in International Knee Documentation Committee Subjective Knee Form (IKDC) and Lysholm scores postoperatively, with no significant differences observed 12 months post-surgery.
CONCLUSION
The findings of this study suggest that 3D printing-assisted arthroscopic IDEAL point femoral tunnel positioning and conventional arthroscopic positioning are feasible and effective for ACL reconstruction. Using 3D printing technology to design femoral anchor points in ACL reconstruction allows for the customization of anterior fork reconstruction and precise bone tunnel positioning, supporting the goal of individualized and accurate reconstruction.
Topics: Humans; Anterior Cruciate Ligament Reconstruction; Printing, Three-Dimensional; Retrospective Studies; Femur; Arthroscopy; Male; Female; Adult; Young Adult; Anterior Cruciate Ligament Injuries; Tomography, X-Ray Computed; Anterior Cruciate Ligament; Feasibility Studies; Adolescent; Surgery, Computer-Assisted; Middle Aged; Treatment Outcome
PubMed: 38898426
DOI: 10.1186/s12891-024-07591-y