Asian Journal of Surgery Jun 2024
PubMed: 38876885
DOI: 10.1016/j.asjsur.2024.05.304 -
Current Treatment Options in... Dec 2023Sudden cardiac arrest is associated with high morbidity and mortality. Despite having a disproportionate burden of sudden cardiac death (SCD), rates of primary and...
PURPOSE OF REVIEW
Sudden cardiac arrest is associated with high morbidity and mortality. Despite having a disproportionate burden of sudden cardiac death (SCD), rates of primary and secondary prevention of SCD with implantable cardioverter-defibrillator (ICD) therapy are lower among eligible racially minoritized patients. This review highlights the racial and ethnic disparities in ICD utilization, associated barriers to ICD care, and proposed interventions to improve equitable ICD uptake.
RECENT FINDINGS
Racially minoritized populations are disproportionately eligible for ICD therapy but are less likely to see cardiac specialists, be counseled on ICD therapy, and ultimately undergo ICD implantation, fueling disparate outcomes. Racial disparities in ICD utilization are multifactorial, with contributions at the patient, provider, health system, and structural/societal level.
SUMMARY
Racial and ethnic disparities have been demonstrated in preventing SCD with ICD use. Proposed strategies to mitigate these disparities must prioritize care delivery and access to care for racially minoritized patients, increase the diversification of clinical and implementation trial participants and the healthcare workforce, and center reparative justice frameworks to rectify a long history of racial injustice.
PubMed: 38873495
DOI: 10.1007/s11936-023-01025-z -
Resuscitation Plus Sep 2024The aim of this study was to analyze the feasibility of a new resuscitation strategy in which breaths are provided during automated external defibrillator (AED) rhythm...
OBJECTIVE
The aim of this study was to analyze the feasibility of a new resuscitation strategy in which breaths are provided during automated external defibrillator (AED) rhythm analysis, and to evaluate its impact on chest compressions (CC) quality and the -analysis time.
METHOD
A randomized simulation study, comparing two cardiopulmonary resuscitations strategies, has been conducted: the standard strategy (S1) with strategy involving ventilation during AED analysis (S2). Thirty lifeguards have performed both strategies in a cross-over study design during 10 min of CPR.
RESULTS
The number of ventilations per 10 min increases from 47 (S1) to 72 (S2) ( < 0.001). This results in the delivery of an additional 17.1 L of insufflated air in S2 compared to S1 ( < 0.001). There have been no significant changes in frequency and total number of CC. These findings correspond to a reduction of the non-ventilation period from 176 s (S1) to 48 s (S2).
CONCLUSIONS
This simulation study suggests that it is feasible to increase the number of ventilations during resuscitation following drowning, without affecting the quantity and quality of chest compressions. The results of this study may serve as a foundation for further investigation into optimal ventilation strategies in this context.
PubMed: 38873276
DOI: 10.1016/j.resplu.2024.100674 -
Frontiers in Genetics 2024Long QT syndrome (LQTS) is an inherited malignant arrhythmia syndrome that poses a risk of sudden death. Variants in the Potassium Voltage-Gated Channel Subfamily H...
BACKGROUND
Long QT syndrome (LQTS) is an inherited malignant arrhythmia syndrome that poses a risk of sudden death. Variants in the Potassium Voltage-Gated Channel Subfamily H Member 2 () gene are known to cause Long QT syndrome through an autosomal dominant inheritance pattern. However, as of now, there have been no reports of any variant leading to Long QT syndrome exhibiting incomplete penetrance that is influenced by gender.
METHODS
Whole-exome sequencing (WES) was conducted on the proband to identify pathogenic variants. Subsequently, Sanger sequencing was employed to validate the identified likely pathogenic variants in all family members.
RESULTS
We analyzed a pedigree spanning three-generations afflicted by Long QT syndrome. WES revealed a novel missense variant (p.Val630Gly, c.1889 T>G) as the causative factor for the family's phenotype. Within this family, all three male carriers of the variant carriers exhibited the Long QT syndrome phenotype: one experienced sudden death during sleep, another received an implantable cardioverter defibrillator (ICD), and a younger man displayed a prolonged QTc interval without any instances of syncope or malignant arrhythmia to date. Interestingly, the middle-aged female carrier showed no Long QT Syndrome phenotype. However, her offspring, diagnosed with Turner syndrome (45, X) and also a carrier of this variant, experienced frequent syncope starting at 12 years old and was diagnosed with Long QT syndrome, leading to an ICD implantation when she was 15 years old. These observations suggest that the manifestation of Long QT syndrome associated with this KCNH2 variant exhibits incomplete penetrance influenced by gender within this family, indicating potential protective mechanisms against the syndrome in females affected by this variant.
CONCLUSION
Our investigation has led to the identification of a novel pathogenic variant responsible for Long QT syndrome within a familial context characterized by gender-selective, incomplete penetrance. This discovery highlights a unique pathogenic inheritance pattern for the gene associated with Long QT syndrome, and could potentially shed light on the distinct penetrance behaviors and patterns of the gene. This discovery broadens our exploration of the KCNH2 gene in cardiac arrhythmias, highlighting the intricate genetic dynamics behind Long QT syndrome.
PubMed: 38873110
DOI: 10.3389/fgene.2024.1409459 -
Indian Pacing and Electrophysiology... Jun 2024The risk of complications associated with transvenous ICDs make the subcutaneous implantable cardiac defibrillator (S-ICD) a valuable alternative in patients with adult...
INTRODUCTION
The risk of complications associated with transvenous ICDs make the subcutaneous implantable cardiac defibrillator (S-ICD) a valuable alternative in patients with adult congenital heart disease (ACHD). However, higher S-ICD ineligibility and higher inappropriate shock rates-mostly caused by T wave oversensing (TWO)- are observed in this population. We report a novel application of deep learning methods to screen patients for S-ICD eligibility over a longer period than conventional screening.
METHODS
Adult patients with ACHD and a control group of normal subjects were fitted with a 24-h Holters to record their S-ICD vectors. Their T:R ratio was analysed utilising phase space reconstruction matrices and a deep learning-based model to provide an in-depth description of the T: R variation plot for each vector. T: R variation was compared statistically using t-test.
RESULTS
13 patients (age 37.4 ± 7.89 years, 61.5 % male, 6 ACHD and 7 control subjects) were enrolled. A significant difference was observed in the mean and median T: R values between the two groups (p < 0.001). There was also a significant difference in the standard deviation of T: R between both groups (p = 0.04).
CONCLUSIONS
T:R ratio, a main determinant for S-ICD eligibility, is significantly higher with more tendency to fluctuate in ACHD patients when compared to a population with normal hearts. We hypothesise that our novel model could be used to select S-ICD eligible patients by better characterisation of T:R ratio, reducing the risk of TWO and inappropriate shocks in the ACHD patient cohort.
PubMed: 38871179
DOI: 10.1016/j.ipej.2024.06.003 -
Resuscitation Jun 2024Non-shockable initial rhythm is a known risk factor for high mortality at cardiac arrest (CA). However, knowledge on its association with self-reported health in CA...
BACKGROUND
Non-shockable initial rhythm is a known risk factor for high mortality at cardiac arrest (CA). However, knowledge on its association with self-reported health in CA survivors is still incomplete.
AIM
To examine the associations between initial rhythm and self-reported health in CA survivors.
METHODS
This nationwide study used data from the Swedish Register for Cardiopulmonary Resuscitation 3-6 months post CA. Health status was measured using EQ-5D-5L and psychological distress by the Hospital Anxiety and Depression Scale (HADS). Kruskal-Wallis test was used to examine differences in self-reported health between groups of different initial rhythms. To control for potential confounders, age, sex, place of CA, aetiology, witnessed status, time to CPR, time to defibrillation, and neurological function were included as covariates in multiple regression analyses for continuous and categorical outcomes.
RESULTS
The study included 1783 adult CA survivors. Overall, the CA survivors reported good health status and symptoms of anxiety or depression were uncommon (13.7% and 13.9% respectively). Survivors with PEA and asystole reported significantly more problems in all dimensions of health status (p = 0.037 to p < 0.001), anxiety (p = 0.034), and depression (p = 0.017) compared to VT/VF. Overall, these differences did not remain in the adjusted regression analyses.
CONCLUSIONS
Initial rhythm is not associated with self-reported health when potential confounders are controlled. Initial rhythm seems to be an indicator of unfavourable factors causing the arrest, or factors related to characteristics and treatment. Therefore, initial rhythm may be used as a proxy for identifying patients at risk for poor outcomes such as worse health status and psychological distress.
PubMed: 38871072
DOI: 10.1016/j.resuscitation.2024.110268 -
MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads.Radiology. Cardiothoracic Imaging Jun 2024Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or...
Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device © RSNA, 2024.
Topics: Humans; Male; Female; Aged; Defibrillators, Implantable; Retrospective Studies; Pacemaker, Artificial; Magnetic Resonance Imaging; Middle Aged; Equipment Failure
PubMed: 38869431
DOI: 10.1148/ryct.230303 -
Clinical Practice and Cases in... May 2024Spontaneous splenic rupture is an extremely rare complication of infective endocarditis.
INTRODUCTION
Spontaneous splenic rupture is an extremely rare complication of infective endocarditis.
CASE REPORT
We present a case of a 56-year-old immunocompetent female with porcine bioprosthetic mitral valve replacement, automated implanted cardioverter-defibrillator, and atrial fibrillation on apixaban who was found to have in-hospital atraumatic splenic rupture complicating infective endocarditis with The rupture was treated successfully by endovascular embolization. Usual treatment with six weeks of antibiotics provided durable cure without further complication, and no surgical intervention was needed for either the valve or spleen.
CONCLUSION
Transcatheter arterial embolization should be considered early in atraumatic splenic rupture. Relevant abdominal and cerebral imaging should be considered in all cases of suspected or confirmed infective endocarditis where unexplained symptoms are present.
PubMed: 38869341
DOI: 10.5811/cpcem.1399 -
Clinical Practice and Cases in... May 2024Implantable cardioverter-defibrillator (ICD) lead perforation through the myocardium may result in chest pain and electrocardiogram (ECG) changes concerning for...
INTRODUCTION
Implantable cardioverter-defibrillator (ICD) lead perforation through the myocardium may result in chest pain and electrocardiogram (ECG) changes concerning for ST-segment elevation myocardial infarction. The clinical context of the ECG aids in appropriate management.
CASE REPORT
We report the case of a 71-year-old woman experiencing chest pain after an ICD placement two weeks earlier. On presentation, she exhibited ST-segment elevation on her ECG. Computed tomography confirmed ICD lead migration. The patient's hemodynamics were normal, and she was discharged home after a five-day hospital stay following a lead revision.
CONCLUSION
Although rare, ICD lead perforation is a potential cause of chest pain and ischemic ECG changes. Emergency physicians should consider lead perforation as a potential differential diagnosis when evaluating chest pain in patients with ICDs, taking into account the potential complications of coronary angiography.
PubMed: 38869330
DOI: 10.5811/cpcem.1466 -
European Heart Journal Supplements :... Apr 2024Arrhythmic storm is a clinical emergency associated with high mortality, which requires multi-disciplinary management. Reprogramming of the implantable cardiac...
Arrhythmic storm is a clinical emergency associated with high mortality, which requires multi-disciplinary management. Reprogramming of the implantable cardiac defibrillator (ICD) aimed at reducing shocks, adrenergic blockade using beta-blockers, sedation/anxiolysis, and blockade of the stellate ganglion represent the first simple and effective manoeuvres, but further suppression of arrhythmias with antiarrhythmics is often required. A low-risk patient (e.g. monomorphic ventricular tachycardia, functioning ICD, and haemodynamically stable) should be managed with a beta-blocker (possibly non-selective) plus amiodarone, in addition to sedation with a benzodiazepine or dexmedetomidine; in patients at greater risk (high burden and haemodynamic instability), autonomic modulation with blockade of the stellate ganglion and the addition of a second antiarrhythmic (lidocaine) should be considered. In patients refractory to these measures, with advanced heart failure, general anaesthesia with intubation and the establishment of a haemodynamic circulatory support should be considered. Ablation, performed early, appears to be superior in terms of mortality and reduction of future shocks compared with titration of antiarrhythmics.
PubMed: 38867867
DOI: 10.1093/eurheartjsupp/suae016