-
Polymers Jun 2024This study aimed to evaluate the flexural strength (FS), surface wear, and optical properties of 3D-printed dental resins subjected to different post-printing...
This study aimed to evaluate the flexural strength (FS), surface wear, and optical properties of 3D-printed dental resins subjected to different post-printing conditions. A total of 240 specimens (2 × 2 × 25 mm³) were 3D-printed using resin materials for permanent (VaresoSmile Crown Plus) VSC and temporary (VaresoSmile Temp) VST restorations. Specimens underwent five post-printing conditions: no post-printing cure; post-cured in a Form Cure curing unit; Visio Beta Vacuum; Ivoclar Targis; or heat-cured (150 °C) for 30 min. Each group of specimens ( = 24) was tested either directly after post-curing, after 24 h of dry storage, or following hydrothermal accelerated aging in boiling water for 16 h. The three-point bending test was used to evaluate the FS. The two-body wear test was performed on 50 disc-shaped specimens ( = 5/group). Surface gloss and translucency were measured for permanent VSC specimens ( = 5/group). SEM/EDS and statistical analyses were performed. The Form Cure device yielded the highest FS and lowest wear depth ( < 0.05). Hydrothermal aging significantly reduced FS. There were no statistical differences in FS and wear values between materials subjected to same post-printing conditions. VSC groups exhibited similar optical properties across different post-printing treatments. Post-printing treatment conditions had a significant impact on the FS and wear of the 3D-printed resin, while optical properties remained unaffected.
PubMed: 38932063
DOI: 10.3390/polym16121713 -
Polymers Jun 2024Bovine serum albumin (BSA) hydrogels are non-immunogenic, low-cost, biocompatible, and biodegradable. In order to avoid toxic cross-linking agents, gellan was oxidized...
Bovine serum albumin (BSA) hydrogels are non-immunogenic, low-cost, biocompatible, and biodegradable. In order to avoid toxic cross-linking agents, gellan was oxidized with NaIO to obtain new functional groups like dialdehydes for protein-based hydrogel cross-linking. The formed dialdehyde groups were highlighted with FT-IR and NMR spectroscopy. This paper aims to investigate hydrogel films for biomedical applications obtained by cross-linking BSA with oxidized gellan (OxG) containing immobilized β-cyclodextrin-curcumin inclusion complex (β-CD-Curc) The β-CD-Curc improved the bioavailability and solubility of Curc and was prepared at a molar ratio of 2:1. The film's structure and morphology were evaluated using FT-IR spectroscopy and SEM. The swelling degree (Q%) values of hydrogel films depend on hydrophilicity and pH, with higher values at pH = 7.4. Additionally, the conversion index of -NH groups into Schiff bases increases with an increase in OxG amount. The polymeric matrix provides protection for Curc, is non-cytotoxic, and enhances antioxidant activity. At pH = 5.5, the skin permeability and release efficiency of encapsulated curcumin were higher than at pH = 7.4 because of the interaction of free aldehyde and carboxylic groups from hydrogels with amine groups from proteins present in the skin membrane, resulting in a better film adhesion and more efficient curcumin release.
PubMed: 38931981
DOI: 10.3390/polym16121631 -
Pharmaceutics Jun 2024Despite the high success rates of dental implants, peri-implantitis is currently the most common complication in dental implantology. Peri-implantitis has an... (Review)
Review
Despite the high success rates of dental implants, peri-implantitis is currently the most common complication in dental implantology. Peri-implantitis has an inflammatory nature, it is associated with the accumulation of plaque in the peri-implant tissues, and its evolution can be progressive depending on various factors, comorbidities, and poor oral health. Prophylaxis and different treatment methods have been widely discussed in recent decades, and surgical and non-surgical techniques present both advantages and disadvantages. In this work, a literature review of different studies on the application of adjuvant treatments, such as local and systemic antibiotics and antiseptic treatments, was conducted. Positive outcomes have been found in the short (up to one year after treatment) and long term (up to ten years after treatment) with combined therapies. However, there is still a need to explore new therapies based on the use of advanced drug delivery systems for the effective treatment of peri-implantitis in the long term and without relapses. Hence, micro- and nanoparticles, implants, and injectable hydrogels, among others, should be considered in future peri-implantitis treatment with the aim of enhancing overall therapy outcomes.
PubMed: 38931890
DOI: 10.3390/pharmaceutics16060769 -
Pharmaceuticals (Basel, Switzerland) Jun 2024Periodontitis preceded by gingivitis is the most common form of periodontal disease and occurs due to the interaction of microorganisms present in the complex bacterial...
BACKGROUND
Periodontitis preceded by gingivitis is the most common form of periodontal disease and occurs due to the interaction of microorganisms present in the complex bacterial aggregates of dental plaque biofilm and their metabolism products with periodontal tissues. Histamine is a heterocyclic biogenic amine acting via four types of receptors. Histamine H receptors act as presynaptic auto/heteroreceptors to regulate the release of histamine and other neurotransmitters.
AIM
Since the nervous system is able to regulate the progression of the inflammatory process and bone metabolism, the aim of this study was to investigate the effects of DL76, which acts as an antagonist/inverse agonist of H receptors, on the course of experimental periodontitis.
MATERIALS AND METHODS
This study was conducted in 24 mature male Wistar rats weighing 245-360 g, aged 6-8 weeks. A silk ligature was placed on the second maxillary molar of the right maxilla under general anesthesia. From the day of ligating, DL76 and 0.9% NaCl solutions were administered subcutaneously for 28 days in the experimental and control groups, respectively. After the experiment, histopathological, immunohistochemical and radiological examinations were performed.
RESULTS
Ligation led to the development of the inflammatory process with lymphocytic infiltration, increased epithelial RANKL and OPG expression as well as bone resorption. DL76 evoked a reduction in (1) lymphocytic infiltration, (2) RANKL and OPG expression as well as (3) bone resorption since the medians of the mesial and distal interdental spaces in the molars with induced periodontitis were 3.56-fold and 10-fold lower compared to the corresponding values in saline-treated animals with periodontitis.
CONCLUSION
DL76 is able to inhibit the progression of experimental periodontitis in rats, as demonstrated by a reduction in the inflammatory cell infiltration, a decrease in the RANKL/RANK OPG pathway expression and a reduction in the alveolar bone resorption.
PubMed: 38931459
DOI: 10.3390/ph17060792 -
Pharmaceuticals (Basel, Switzerland) Jun 2024The treatment adherence of narcotics-addicted individuals with reduced incidences of relapse can be enhanced by a sustained drug release formulation of antinarcotics. So...
The treatment adherence of narcotics-addicted individuals with reduced incidences of relapse can be enhanced by a sustained drug release formulation of antinarcotics. So far, different drug formulations have been reported with sustained drug release periods of 28 and 35 days. To further enhance this duration, different formulations of injectable hydrogels (IHs) have been developed by combining low molecular weight (LMW) and high molecular weight (HMW) chitosan (CS) with guar gum (GG) and crosslinking them by sodium bi phosphate dibasic. The structural, morphological, and physicochemical properties of LMW-CS IH, and HMW-CS IH were evaluated using Fourier transform infrared spectroscopy (FT-IR), thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), and rheological, swelling, and biodegradation analysis. The HMW-CS IH showed high crosslinking, increased thermal stability, high mechanical strength, elevated swelling, and low biodegradation. The antinarcotic drugs naltrexone (NTX) and disulfiram (DSF) were loaded separately into the HMW-CS IH and LMW-CS IH. The release of NTX and DSF was investigated in phosphate buffer saline (PBS) and ethanol (0.3%, 0.4%, and 0.5%) over a 56-day period using an UV spectrophotometer. The drug release data were tested in zero-order, first-order, and Korsemeyer-Peppas mathematical models. In PBS, all prepared formulations followed non-Fickian drug release, while in ethanol, only NTX HMW-CS IH followed non-Fickian release in all three different concentrations of ethanol.
PubMed: 38931416
DOI: 10.3390/ph17060749 -
Nutrients Jun 2024The use of natural products as alternatives to traditional pharmacological treatments in orthodontics is gaining interest due to their anti-inflammatory, antibacterial,... (Review)
Review
The use of natural products as alternatives to traditional pharmacological treatments in orthodontics is gaining interest due to their anti-inflammatory, antibacterial, and antioxidant properties. This systematic review synthesizes evidence from clinical trials to evaluate the efficacy of natural products in reducing inflammation and bacterial presence in orthodontic and orthognathic treatment settings. The database search was conducted across PubMed, Scopus, and Embase up to January 2024. The review focused on randomized controlled trials only. The selected studies centered on the anti-inflammatory, antibacterial, and antioxidant effects of natural products, adhering to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines for data extraction. Nine studies, totaling 358 participants, were included. Significant findings demonstrated a reduction in gingival inflammation by over 40% with the use of Aloe vera compared to chlorhexidine. Another study noted a decrease in bleeding on probing by 13.6 points in the treatment group over placebo. Additionally, honey showed a rapid modulation of plaque pH and significantly reduced bacterial counts of . Furthermore, the use of resveratrol emulgel was linked to substantial improvements in gingival health, with a reduction in the gingival index and probing pocket depth. The results indicate that natural products can significantly enhance orthodontic treatment outcomes by reducing inflammation and bacterial levels. These products offer effective alternatives to traditional treatments and show potential for integration into routine orthodontic care protocols. Further research is encouraged to standardize application methods and dosages to maximize clinical benefits and patient satisfaction.
Topics: Humans; Aloe; Anti-Bacterial Agents; Anti-Inflammatory Agents; Antioxidants; Biological Products; Chlorhexidine; Dentofacial Deformities; Gingivitis; Honey; Orthodontics; Plant Preparations; Randomized Controlled Trials as Topic; Resveratrol; Streptococcus mutans; Treatment Outcome
PubMed: 38931295
DOI: 10.3390/nu16121941 -
Materials (Basel, Switzerland) Jun 2024This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness....
This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (µ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement.
PubMed: 38930391
DOI: 10.3390/ma17123019 -
Materials (Basel, Switzerland) Jun 2024Barium zirconate (BaZrO, BZO), which exhibits superior mechanical, thermal, and chemical stability, has been widely used in many applications. In dentistry, BZO is used...
Barium zirconate (BaZrO, BZO), which exhibits superior mechanical, thermal, and chemical stability, has been widely used in many applications. In dentistry, BZO is used as a radiopacifier in mineral trioxide aggregates (MTAs) for endodontic filling applications. In the present study, BZO was prepared using the sol-gel process, followed by calcination at 700-1000 °C. The calcined BZO powders were investigated using X-ray diffraction and scanning electron microscopy. Thereafter, MTA-like cements with the addition of calcined BZO powder were evaluated to determine the optimal composition based on radiopacity, diametral tensile strength (DTS), and setting times. The experimental results showed that calcined BZO exhibited a majority BZO phase with minor zirconia crystals. The crystallinity, the percentage, and the average crystalline size of BZO increased with the increasing calcination temperature. The optimal MTA-like cement was obtained by adding 20% of the 700 °C-calcined BZO powder. The initial and final setting times were 25 and 32 min, respectively. They were significantly shorter than those (70 and 56 min, respectively) prepared with commercial BZO powder. It exhibited a radiopacity of 3.60 ± 0.22 mmAl and a DTS of 3.02 ± 0.18 MPa. After 28 days of simulated oral environment storage, the radiopacity and DTS decreased to 3.36 ± 0.53 mmAl and 2.84 ± 0.27 MPa, respectively. This suggests that 700 °C-calcined BZO powder has potential as a novel radiopacifier for MTAs.
PubMed: 38930384
DOI: 10.3390/ma17123015 -
Materials (Basel, Switzerland) Jun 2024Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the...
Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the restoration surface conditions and their mechanical behavior. The objective of this study was to evaluate the effect of different CAD/CAM milling protocols on the topography and fracture behavior of zirconia monolithic crowns (3Y-PSZ) subjected to a chewing simulation. Monolithic 3Y-PSZ premolar crowns were milled using three protocols ( = 13) (slow (S), normal (N), and fast (F)). Crowns were cemented on a dentin analog abutment and subjected to mechanical aging (200 N, 2 Hz, 1,500,000 cycles, 37 °C water). Surviving crowns were subjected to compressive load test and analyzed using fractography. Fracture load data were analyzed with two-parameter Weibull analysis. The surface topography of the crowns was examined with a stereomicroscope and a 3D non-contact profiler. All crowns survived the chewing simulation. Crowns milled using the F protocol had the greatest characteristic fracture load, while crowns produced with the S protocol showed high Weibull modulus. Groups N and S had a more uniform surface and detailed occlusal anatomy than group F. The CAD/CAM milling protocol affected the topography and mechanical behavior of 3Y-PSZ monolithic crowns.
PubMed: 38930350
DOI: 10.3390/ma17122981 -
Materials (Basel, Switzerland) Jun 2024Fluorescence-aided identification technique (FIT) studies for orthodontic resins are relatively new, using an arbitrary selection of resins, lights, and work parameters....
BACKGROUND
Fluorescence-aided identification technique (FIT) studies for orthodontic resins are relatively new, using an arbitrary selection of resins, lights, and work parameters. In order to provide FIT guidelines for optimal visualization, the objectives of this study were to describe the electromagnetic characteristics of fluorescent orthodontic resins, determine appropriate light specification, and describe light and work parameter effects on resin fluorescence.
METHODS
This in vitro study assessed five fluorescent orthodontic resins and a non-fluorescent control resin using spectrophotometry, a scaled image analysis of 25 μm thick resins to compare intensities, and a visual assessment. Light sources varied by flashlight lens (narrow [N], average [X], and magnified [Z]) and UV intensity (X and X High). Work parameters included distance (20-300 mm) and angulation (15-70°). Visual scores were assigned to determine discernibility.
RESULTS
The average excitation maxima was 384 nm. Fluorescence increased with more direct UV light exposure. The highest intensity was recorded with Light X High at 50 mm and 70°. Visual assessment followed image analysis trends, and fluorescence was clinically discernable for all 25 μm thick samples.
CONCLUSIONS
Excitation wavelength range of 395-405 nm is appropriate for FIT illumination. All resins were anisotropic and showed greater fluorescence with greater angle, higher UV intensity, and closer proximity.
PubMed: 38930329
DOI: 10.3390/ma17122961