ACS Sensors Dec 2021A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from...
A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs.
Topics: COVID-19; Enzyme-Linked Immunosorbent Assay; Humans; Immunoassay; Microfluidics; SARS-CoV-2
PubMed: 34854666
DOI: 10.1021/acssensors.1c01524 -
BMJ Open Nov 2021Uncomplicated lower urinary tract infections (uLUTI) are a common problem in primary care. Current local guidelines recommend the use of a single 3 g dose of...
Clinical effectiveness and bacteriological eradication of three different Short-COurse antibiotic regimens and single-dose fosfomycin for uncomplicated lower Urinary Tract infections in adult women (SCOUT study): study protocol for a randomised clinical trial.
INTRODUCTION
Uncomplicated lower urinary tract infections (uLUTI) are a common problem in primary care. Current local guidelines recommend the use of a single 3 g dose of fosfomycin. However, most general practitioners (GP) prefer short-course therapies to single-dose therapy. No study has compared head-to-head short-course antimicrobial agents for uLUTIs. Therefore, the aim of this randomised clinical trial is to compare three different short-course antibiotic therapies with a single-dose of fosfomycin for these infections.
METHODS AND ANALYSIS
This will be a pragmatic, multicentre, parallel group, open trial. Women aged 18 or older and with symptoms of uLUTI and a positive urine dipstick analysis will be randomised to one of the following four groups: a single dose of 3 g of fosfomycin, 2 days of 3 g of fosfomycin o.d., 3 days of pivmecillinam 400 mg three times per day (t.i.d) or 5 days of nitrofurantoin 100 mg t.i.d. A total sample of 1120 patients was calculated. The primary endpoint is clinical effectiveness at day 7, defined as cure of symptoms reported by the patients in a diary including four symptoms: dysuria, urgency, frequency and suprapubic pain, which will be scored on a 4-point severity scale (not present/mild/moderate/severe). Follow-up visits are scheduled at days 7 (phone call), 14 and 28 for assessing evolution. Urine samples will be collected in the three on-site visits and urine cultures performed. If positive, antibiograms for the three antibiotics studied will be performed. Bacterial eradication will be measured at days 14 and 28.
ETHICS AND DISSEMINATION
The study was approved by the Ethical Board of IDIAP Jordi Gol (reference number: 21/173-AC) and Spanish Agency of Medicines and Medical Devices. The findings of this trial will be disseminated through research conferences and peer-review journals.
TRIAL REGISTRATION NUMBER
NCT04959331; EudraCT Number: 2021-001332-26.
TIME SCHEDULE
January 2022 to April 2023.
Topics: Adult; Anti-Bacterial Agents; Clinical Trials as Topic; Female; Fosfomycin; Humans; Nitrofurantoin; Random Allocation; Treatment Outcome; Urinary Tract Infections
PubMed: 34824124
DOI: 10.1136/bmjopen-2021-055898 -
BMC Cardiovascular Disorders Nov 2021Atherosclerosis is a vital cause of cardiovascular diseases. The correlation between proteinuria and atherosclerosis, however, has not been confirmed. This study aimed... (Observational Study)
Observational Study
BACKGROUND AND AIMS
Atherosclerosis is a vital cause of cardiovascular diseases. The correlation between proteinuria and atherosclerosis, however, has not been confirmed. This study aimed to assess whether there is a relationship between proteinuria and atherosclerosis.
METHODS
From January 2016 to September 2020, 13,545 asymptomatic subjects from four centres in southern China underwent dipstick proteinuria testing and carotid atherosclerosis examination. Data on demography and past medical history were collected, and laboratory examinations were performed. The samples consisted of 7405 subjects (4875 males and 2530 females), excluding subjects failing to reach predefined standards and containing enough information. A multivariate logistic regression model was used to adjust the influence of traditional risk factors for atherosclerosis on the results.
RESULTS
Compared with proteinuria-negative subjects, proteinuria-positive subjects had a higher prevalence rate of carotid atherosclerosis. The differences were statistically significant (22.6% vs. 26.7%, χ = 10.03, p = 0.002). After adjusting for common risk factors for atherosclerosis, age, sex, BMI, blood lipids, blood pressure, renal function, hypertensive disease, diabetes mellitus and hyperlipidaemia, proteinuria was an independent risk factor for atherosclerosis (OR = 1.191, 95% CI 1.015-1.398, p = 0.033). The Hosmer-Lemeshow test was used to test the risk prediction model of atherosclerosis, and the results showed that the model has high goodness of fit and strong independent variable prediction ability.
CONCLUSIONS
Proteinuria is independently related to carotid atherosclerosis. With the increase in proteinuria level, the risk of carotid atherosclerotic plaque increases. For patients with positive proteinuria, further examination of atherosclerosis should not be ignored.
Topics: Adolescent; Adult; Aged; Aged, 80 and over; Carotid Artery Diseases; China; Cross-Sectional Studies; Female; Humans; Male; Middle Aged; Predictive Value of Tests; Prognosis; Proteinuria; Reagent Strips; Risk Assessment; Risk Factors; Ultrasonography, Doppler, Color; Urinalysis; Young Adult
PubMed: 34798829
DOI: 10.1186/s12872-021-02367-x -
Journal of Pharmaceutical and... Jan 2022Artesunate-mefloquine is one of the commonly-used artemisinin-based combination therapies (ACTs). Given the significance of drug quality in the management of malaria...
Artesunate-mefloquine is one of the commonly-used artemisinin-based combination therapies (ACTs). Given the significance of drug quality in the management of malaria cases, the objective of this study was to develop antibody-based assays as the point-of-care (POC) tests for monitoring the quality of this ACT. Using mefloquine conjugated to a carrier protein as the immunogen, we selected a specific monoclonal antibody (mAb) against mefloquine with no cross-reactivity to other antimalarial drugs. Using this mAb, we developed a direct competitive enzyme-linked immunosorbent assay (dcELISA) and a lateral flow immunoassay (LFIA) to measure the mefloquine contents. The dcELISA for mefloquine showed a 50% inhibitory concentration (IC) and a working range of 2.79 ng/mL and 0.58-16.37 ng/mL, respectively. With the aid of a portable optical scanner, the LFIA had a working range of 0.15-2.67 µg/mL for mefloquine. When used to measure mefloquine contents in commercial drugs, the dcELISA and LFIA results were compatible with those determined using high-performance liquid chromatography. Using the same LFIA format, we developed a combination LFIA, which correctly estimated the artesunate and mefloquine contents in commercial ACTs. Therefore, both LFIAs could be used as POC devices for rapid quality control of artesunate and mefloquine in ACTs.
Topics: Antimalarials; Artesunate; Drug Therapy, Combination; Immunoassay; Mefloquine; Quality Control
PubMed: 34634530
DOI: 10.1016/j.jpba.2021.114342 -
Biosensors Sep 2021The fast detection of trace amounts of hazardous contaminations can prevent serious damage to the environment. Paper-based sensors offer a new perspective on the world... (Review)
Review
The fast detection of trace amounts of hazardous contaminations can prevent serious damage to the environment. Paper-based sensors offer a new perspective on the world of analytical methods, overcoming previous limitations by fabricating a simple device with valuable benefits such as flexibility, biocompatibility, disposability, biodegradability, easy operation, large surface-to-volume ratio, and cost-effectiveness. Depending on the performance type, the device can be used to analyze the analyte in the liquid or vapor phase. For liquid samples, various structures (including a dipstick, as well as microfluidic and lateral flow) have been constructed. Paper-based 3D sensors are prepared by gluing and folding different layers of a piece of paper, being more user-friendly, due to the combination of several preparation methods, the integration of different sensor elements, and the connection between two methods of detection in a small set. Paper sensors can be used in chromatographic, electrochemical, and colorimetric processes, depending on the type of transducer. Additionally, in recent years, the applicability of these sensors has been investigated in various applications, such as food and water quality, environmental monitoring, disease diagnosis, and medical sciences. Here, we review the development (from 2010 to 2021) of paper methods in the field of the detection and determination of toxic substances.
Topics: Biosensing Techniques; Colorimetry; Environmental Monitoring; Hazardous Substances; Microfluidics; Paper; Point-of-Care Systems
PubMed: 34562906
DOI: 10.3390/bios11090316 -
Clinical Microbiology and Infection :... Feb 2022Cholera is an acute diarrheal disease caused by Vibrio cholerae O1 or O139. Cholera rapid diagnostic tests (RDTs) are widely used to screen for cholera cases. However,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Cholera is an acute diarrheal disease caused by Vibrio cholerae O1 or O139. Cholera rapid diagnostic tests (RDTs) are widely used to screen for cholera cases. However, their accuracy has not been systematically reviewed.
OBJECTIVES
To evaluate the diagnostic accuracy of cholera RDTs.
METHODS
Systematic review and meta-analysis.
DATA SOURCES
Medline, EMBASE and Web of science through to November 2020; references of included studies and a technical guidance on cholera RDTs. This review is registered with PROSPERO (CRD42021233124).
STUDY ELIGIBILITY CRITERIA
Cross-sectional studies comparing the performance of cholera RDTs either to stool culture or PCR.
PARTICIPANTS
Individuals with clinically suspected cholera.
DATA EXTRACTION
Two authors independently extracted data and assessed the quality using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria.
RESULTS
Eighteen studies were included in the systematic review of which 17 were used for meta-analysis. Crystal VC was the most frequently used RDT (13 studies), followed by Cholkit and Institut Pasteur cholera dipstick (three studies each), SD Bioline (two studies), Artron (one study) and Smart (one study). Using direct testing (n = 12 627 specimens), the bivariate random-effects model yielded a pooled sensitivity and specificity of 91% (95% CI 87%-94%) and 80% (95% CI 74%-84%), respectively. However, through alkaline peptone water (APW) enrichment (n = 3403 specimens), the pooled sensitivity and specificity were 89% (95% CI 79%-95%) and 98% (95% CI 95%-99%), respectively.
CONCLUSION
Cholera RDTs, especially when enriched with APW, have moderate sensitivity and specificity. Although less useful for clinical management, the current generation of RDTs have clear utility for surveillance efforts if used in a principled manner. Enrichment of stool specimens in APW before using cholera RDTs reduces the possibility of obtaining false-positive results, despite the few cholera cases that go undetected. It is noteworthy that APW-enriched cholera RDTs are not necessarily rapid tests, and are not listed in the Global Task Force on Cholera Control/WHO target product profile.
Topics: Cholera; Cross-Sectional Studies; Humans; Reagent Kits, Diagnostic; Sensitivity and Specificity; Vibrio cholerae O1
PubMed: 34506946
DOI: 10.1016/j.cmi.2021.08.027 -
BMC Nephrology Jun 2021Most studies of chronic kidney disease (CKD) in Sub-Saharan Africa (SSA) have been conducted in urban settings. They relied on GFR estimated from serum creatinine alone...
BACKGROUND
Most studies of chronic kidney disease (CKD) in Sub-Saharan Africa (SSA) have been conducted in urban settings. They relied on GFR estimated from serum creatinine alone and on the inexpensive, convenient urinary dipstick to assess proteinuria. The dipstick for proteinuria has not been directly compared with the gold standard albumin-to-creatinine ratio (ACR) in a large-sized study in SSA. We hereby assessed the influence of rural versus urban location on the level, interpretation, and diagnostic performance of proteinuria dipstick versus ACR.
METHODS
In a cross-sectional population-based study of CKD in both urban (n = 587) and rural (n = 730) settings in South-Kivu, Democratic Republic of Congo (DRC), we assessed the prevalence, performance (sensitivity, specificity, positive predictive value and negative predictive value) and determinants of a positive dipstick proteinuria as compared with albuminuria (ACR). Albuminuria was subdivided into: A1 (< 30 mg/g creatinine), A2 (30 to 299 mg/g creatinine) and A3 (≥ 300 mg/g creatinine).
RESULTS
The overall prevalence of positive dipstick proteinuria (≥ 1+) was 9.6 % (95 % CI, 7.9-11.3) and was higher in rural than in urban residents (13.1 % vs. 4.8 %, p < 0.001), whereas the prevalence of albuminuria (A2 or A3) was similar in both sites (6 % rural vs. 7.6 % urban, p = 0.31). In both sites, dipstick proteinuria ≥ 1 + had a poor sensitivity (< 50 %) and positive predictive value (< 11 %) for the detection of A2 or A3. The negative predictive value was 95 %. Diabetes [aOR 6.12 (1.52-24.53)] was a significant predictor of A3 whereas alkaline [aOR 7.45 (3.28-16.93)] and diluted urine [aOR 2.19 (1.35-3.57)] were the main predictors of positive dipstick proteinuria.
CONCLUSIONS
ACR and dipstick proteinuria have similar positivity rates in the urban site whereas, in the rural site, dipstick was 2-fold more often positive than ACR. The poor sensitivity and positive predictive value of the dipstick as compared with ACR makes it unattractive as a screening tool in community studies of CKD in SSA.
Topics: Adult; Creatinine; Cross-Sectional Studies; Democratic Republic of the Congo; Female; Glomerular Filtration Rate; Humans; Hydrogen-Ion Concentration; Male; Predictive Value of Tests; Proteinuria; Reagent Strips; Renal Insufficiency, Chronic; Rural Health; Urban Health; Urine
PubMed: 34172013
DOI: 10.1186/s12882-021-02431-w -
MSphere May 2021Isothermal nucleic acid amplification tests (iNATs), such as loop-mediated isothermal amplification (LAMP), are good alternatives to PCR-based amplification assays,...
Isothermal nucleic acid amplification tests (iNATs), such as loop-mediated isothermal amplification (LAMP), are good alternatives to PCR-based amplification assays, especially for point-of-care and low-resource use, in part because they can be carried out with relatively simple instrumentation. However, iNATs can often generate spurious amplicons, especially in the absence of target sequences, resulting in false-positive results. This is especially true if signals are based on non-sequence-specific probes, such as intercalating dyes or pH changes. In addition, pathogens often prove to be moving, evolving targets and can accumulate mutations that will lead to inefficient primer binding and thus false-negative results. Multiplex assays targeting different regions of the analyte and logical signal readout using sequence-specific probes can help to reduce both false negatives and false positives. Here, we describe rapid conversion of three previously described SARS-CoV-2 LAMP assays that relied on a non-sequence-specific readout into individual and multiplex one-pot assays that can be visually read using sequence-specific oligonucleotide strand exchange (OSD) probes. We describe both fluorescence-based and Boolean logic-gated colorimetric lateral flow readout methods and demonstrate detection of SARS-CoV-2 virions in crude human saliva. One of the key approaches to treatment and control of infectious diseases, such as COVID-19, is accurate and rapid diagnostics that is widely deployable in a timely and scalable manner. To achieve this, it is essential to go beyond the traditional gold standard of quantitative PCR (qPCR) that is often faced with difficulties in scaling due to the complexity of infrastructure and human resource requirements. Isothermal nucleic acid amplification methods, such as loop-mediated isothermal amplification (LAMP), have been long pursued as ideal, low-tech alternatives for rapid, portable testing. However, isothermal approaches often suffer from false signals due to employment of nonspecific readout methods. We describe general principles for rapidly converting nonspecifically read LAMP assays into assays that are read in a sequence-specific manner by using oligonucleotide strand displacement (OSD) probes. We also demonstrate that inclusion of OSD probes in LAMP assays maintains the simplicity of one-pot assays and a visual yes/no readout by using fluorescence or colorimetric lateral-flow dipsticks while providing accurate sequence-specific readout and the ability to logically query multiplex amplicons for redundancy or copresence. These principles not only yielded high-surety isothermal assays for SARS-CoV-2 but might also aid in the design of more sophisticated molecular assays for other analytes.
Topics: COVID-19; COVID-19 Testing; Humans; Molecular Diagnostic Techniques; Nucleic Acid Amplification Techniques; Point-of-Care Testing; RNA, Viral; SARS-CoV-2; Saliva
PubMed: 34011690
DOI: 10.1128/mSphere.00911-20 -
Parasite (Paris, France) 2021Toxoplasma gondii is an obligate intracellular protozoan parasite that causes toxoplasmosis and threatens warm-blooded animal and human health worldwide. Simple and...
Toxoplasma gondii is an obligate intracellular protozoan parasite that causes toxoplasmosis and threatens warm-blooded animal and human health worldwide. Simple and applicable diagnostic methods are urgently needed to guide development of effective approaches for prevention of toxoplasmosis. Most molecular diagnostic tools for T. gondii infection require high technical skills, sophisticated equipment, and a controlled lab environment. In this study, we developed a loop-mediated isothermal amplification-lateral-flow-dipstick (LAMP-LFD) assay that specifically targets the 529 bp for detecting T. gondii infection. This novel portable device is universal, fast, user-friendly, and guarantees experimental sensitivity as well as low risk of aerosol contamination. Our LAMP-LFD assay has a detection limit of 1 fg of T. gondii DNA, and shows no cross-reaction with other parasitic pathogens, including Cryptosporidium parvum, Leishmania donovani, and Plasmodium vivax. We validated the developed assay by detecting T. gondii in DNA extracted from blood samples collected from 318 stray cats and dogs sampled from Deqing, Wenzhou, Yiwu, Lishui and Zhoushan cities across Zhejiang province, Eastern China. The LAMP-LFD device detected T. gondii DNA in 4.76 and 4.69% of stray cats and dogs, respectively. In conclusion, the developed LAMP-LFD assay is efficient, minimizes aerosol contamination, and is therefore suitable for detecting T. gondii across basic medical institutions and field settings.
Topics: Animals; Cats; China; Cryptosporidiosis; Cryptosporidium; Dogs; Molecular Diagnostic Techniques; Nucleic Acid Amplification Techniques; Sensitivity and Specificity; Toxoplasma
PubMed: 33944774
DOI: 10.1051/parasite/2021039