-
Biomedicines May 2024Fixed appliance (FA) therapy predisposes patients to white spot lesions (WSLs). The F-ACP complex (amorphous calcium phosphate nanoparticles enriched with carbonate and...
Fixed appliance (FA) therapy predisposes patients to white spot lesions (WSLs). The F-ACP complex (amorphous calcium phosphate nanoparticles enriched with carbonate and fluorine and coated with citrate) has been effective for in vitro enamel remineralization. The aim of this study was to evaluate the efficacy of the F-ACP complex in remineralizing WSLs after FA therapy. One hundred and six adolescents (aged 12-20 years) were randomized into study and control groups after FA therapy. Patients in the study group were advised to use dental mousse containing F-ACP applied within Essix retainers for six months. The presence of WSLs was recorded at baseline (T0), 3 months (T1), and 6 months (T2) according to the International Caries Detection and Assessment System (ICDAS). Visual Plaque Index (VPI) and Gingival Bleeding Index (GBI) were recorded. Among 106 study participants, 91 (52 and 39 in study and control groups, respectively) completed the study. The results showed that the ICDAS score was significantly lower ( < 0.001) in the study group than in the control group between T0 and T2. The application of mousse containing the F-ACP complex inside Essix retainers for six months is effective in remineralizing white spot lesions in patients after FA therapy without side effects.
PubMed: 38927409
DOI: 10.3390/biomedicines12061202 -
Journal of Pharmacy & Bioallied Sciences Apr 2024The current study was conducted with the aim of evaluating the retention protocol followed by orthodontists in India.
AIM
The current study was conducted with the aim of evaluating the retention protocol followed by orthodontists in India.
MATERIAL AND METHODS
A cross-sectional web-based questionnaire survey was carried out to evaluate the retention protocol. To determine the sample size, a pilot study was carried out, and the final sample arrived was 250 subjects. The current study's inclusion criteria took into account those who had finished their BDS&MDS (Orthodontist).
RESULTS
The data were statistically examined when the surveys were received and completed. The choice for fixed retainers was 67.4%. Retainer wear time preferences ranged widely, with 60% preferring 12-18 hours. The initial post-retention check appointment was planned by the majority of orthodontists (47.6%) within the next three months. Recall appointments for retention checks were only planned by the majority of orthodontists (56.3%) once every three months. Regular involvement by patients at their retention check appointments was (38%).
CONCLUSION
The most commonly used and preferred type of retainer is fixed retainer, and dentist preferences range around 12-18 hours of wear time. Furthermore, the duration of the retainer wear preferred by most orthodontists/dentists is 10 months to 2 years.
PubMed: 38882740
DOI: 10.4103/jpbs.jpbs_1099_23 -
BMC Oral Health Jun 2024Clinicians often utilize both flowable and packable composites concurrently in bonding fixed retainers. Thus, this study aimed to assess the synergistic effect of these...
BACKGROUND
Clinicians often utilize both flowable and packable composites concurrently in bonding fixed retainers. Thus, this study aimed to assess the synergistic effect of these composites in the bonding process.
METHODS
This in vitro study divided specimens into three groups: flowable composite (nano-hybrid, Tetric N-Flow, Ivoclar Vivadent), packable composite (nano-hybrid, Tetric N-ceram, Ivoclar Vivadent), and combined use of flowable and packable composite. Shear bond strength (SBS), adhesive remnant index (ARI), and wire pull-out resistance were compared among the groups. Statistical analyses were conducted using ANOVA and Tukey tests to compare study groups. Additionally, Chi-square and Kruskal-Wallis tests were employed to analyze the ARI index among the groups.
RESULTS
ANOVA results indicated no statistically significant differences among test groups (P = 0.129) regarding SBS. However, a significant difference existed between flowable and packable composite groups (P = 0.01) regarding ARI scores. Among the study groups, flowable composite exhibited the highest frequencies of ARI scores of 1 and 2, whereas packable composite showed the highest frequency of ARI scores of 0. The combined group had higher frequencies of ARI scores of 0 and 1 compared to the flowable composite. The wire pull-out test revealed that the combined application of flowable and packable composite resulted in significantly lower detachments compared to the packable composite alone (P = 0.008). However, no significant differences were observed in the comparisons between the flowable-packable (P = 0.522) and combined-flowable (P = 0.128) groups.
CONCLUSION
The combined use of flowable and packable composites for fixed retainers demonstrated adequate shear bond strength and ideal ARI scores, suggesting it as a suitable adhesive system for bonding orthodontic fixed retainers.
Topics: Composite Resins; Orthodontic Retainers; In Vitro Techniques; Shear Strength; Materials Testing; Dental Bonding; Dental Stress Analysis; Humans
PubMed: 38858745
DOI: 10.1186/s12903-024-04437-w -
Journal of Functional Biomaterials May 2024The objective of this study was to explore the effects of fixed orthodontic appliances on enamel structure by assessing microfractures, surface roughness, and... (Review)
Review
AIM
The objective of this study was to explore the effects of fixed orthodontic appliances on enamel structure by assessing microfractures, surface roughness, and alterations in color.
METHODS
This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic search of online databases was conducted using the keywords 'enamel' AND 'orthodontic debonding'. Eligibility criteria included both in vivo and ex vivo clinical trials conducted on human teeth.
RESULTS AND DISCUSSION
A total of 14 relevant papers were analyzed. Various instruments and techniques were utilized across different studies to assess surface roughness, color change, and surface fractures.
CONCLUSIONS
The findings of this study suggest that ceramic brackets may lead to an increase in enamel fractures, particularly during bracket removal. The surface roughness of enamel exhibits variability depending on the adhesive substance and polishing methods used post-removal. Fixed orthodontic appliances could induce changes in enamel color, which may be alleviated by the use of nano-hydroxyapatite or specific polishing techniques. Further research is necessary to identify effective strategies for managing these color changes and improving the overall outcomes of fixed orthodontic treatment.
PubMed: 38786634
DOI: 10.3390/jfb15050123 -
Journal of Orthodontic Science 2024In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid... (Review)
Review
In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The present review has gone some way towards enhancing our understanding of the bonded fixed retainer, types, material, bonding methods, and how to improve its the success rate, besides the importance of new technology in fixed orthodontic retention.
PubMed: 38784083
DOI: 10.4103/jos.jos_159_23 -
Polymers May 2024Polyetheretherketone (PEEK), an organic thermoplastic polymer, has gained interest in dentistry due to its excellent mechanical strength, flexibility, and... (Review)
Review
Polyetheretherketone (PEEK), an organic thermoplastic polymer, has gained interest in dentistry due to its excellent mechanical strength, flexibility, and biocompatibility. Furthermore, the ability to utilize CAD/CAM in the fabrication of PEEK enhances accuracy, reliability, and efficiency while also saving time. Hence, several orthodontic studies have explored the utilization of PEEK in various applications, such as archwires, brackets, fixed lingual retainers, palatal expansion devices, transpalatal arches, Tübingen palatal plates, different types of space maintainers, mini-implant insertion guides, and more. However, a complete systematic review of the available data comparing the performance of PEEK with traditional orthodontic materials has not yet been conducted. Therefore, this systematic review seeks to assess if PEEK material meets the required mechanical criteria to serve as an alternative to conventional orthodontic appliances. To ensure clarity and precision, this review will specifically concentrate on fixed appliances. This systemic review followed the PRISMA guidelines and utilized databases including PubMed/MEDLINE, Embase, Springer, Web of Science, and Wiley. Searches were restricted to English language articles from January 2013 to February 2024. Keywords such as "Polyetheretherketone" or "PEEK" and "Orthodontic" or "Orthodontic device" or "Orthodontic materials" were employed across all databases. Nine studies were incorporated, covering orthodontic archwires, brackets, and fixed lingual retainers. Based on the reviewed literature, PEEK demonstrates promising potential in orthodontic fixed appliances, offering advantages in force delivery, friction reduction, and aesthetic appeal. Further research is needed to fully explore its capabilities and optimize its application in clinical practice.
PubMed: 38732740
DOI: 10.3390/polym16091271 -
Bioengineering (Basel, Switzerland) Apr 2024The efficacy of retainers is a pivotal concern in orthodontic care. This study examined the biomechanical behaviour of retainers, particularly the influence of retainer...
The efficacy of retainers is a pivotal concern in orthodontic care. This study examined the biomechanical behaviour of retainers, particularly the influence of retainer stiffness and tooth resilience on force transmission and stress distribution. To do this, a finite element model was created of the lower jaw from the left to the right canine with a retainer attached on the oral side. Three levels of tooth resilience and variable retainer bending stiffness (influenced by retainer type, retainer diameter, and retainer material) were simulated. Applying axial or oblique (45° tilt) loads on a central incisor, the force transmission increased from 2% to 65% with increasing tooth resilience and retainer stiffness. Additionally, a smaller retainer diameter reduced the uniformity of the stress distribution in the bonding interfaces, causing concentrated stress peaks within a small field of the bonding area. An increase in retainer stiffness and in tooth resilience as well as a more oblique load direction all lead to higher overall stress in the adhesive bonding area associated with a higher risk of retainer bonding failure. Therefore, it might be recommended to avoid the use of retainers that are excessively stiff, especially in cases with high tooth resilience.
PubMed: 38671815
DOI: 10.3390/bioengineering11040394 -
Medicine Apr 2024This paper demonstrates a digital manufacturing technique of a removable orthodontic appliance from an intraoral scan. An intraoral scan was made for the maxillary and...
This paper demonstrates a digital manufacturing technique of a removable orthodontic appliance from an intraoral scan. An intraoral scan was made for the maxillary and mandibular arches. 3Shape Orthodontics Appliance Designer produced the virtual Hawley retainer, consisting of alloy components (Adam Clasps and Fitted Labial bow) and a base plate. The base plate design was modified to adapt to inserting the alloy components, which were combined using cold-cured acrylic. The finished Hawley retainer was assessed intraorally. The described technique emphasizes the design specifications of digitally designed and manufactured removable orthodontic appliances. A combination of additive and subtractive techniques was successfully employed to manufacture the alloy components and base plate. This novel method provides an alternative approach to manufacturing removable appliances with computer-aided design (CAD)/computer-aided manufacturing (CAM) technologies. The described process offers a precursor to digital manufacturing of other developed designs of dental appliances.
Topics: Humans; Printing, Three-Dimensional; Computer-Aided Design; Orthodontic Appliance Design; Polymers; Benzophenones; Polyethylene Terephthalates; Ketones; Alloys; Orthodontic Appliances, Removable
PubMed: 38669369
DOI: 10.1097/MD.0000000000038004 -
Cureus Apr 2024Orthodontists have a variety of options available for retainers. Research in Orthodontics focuses on assessing outcomes important to clinicians; however, there is... (Review)
Review
Orthodontists have a variety of options available for retainers. Research in Orthodontics focuses on assessing outcomes important to clinicians; however, there is inconsistency in how these outcomes are selected and evaluated. This review sought to assess the effects of different orthodontic retainers on patients' quality of life (QoL). Various approaches were employed in this systematic review, and a thorough search was conducted across six databases. The review involved a comprehensive evaluation of six included studies, highlighting changes in dental structure post-treatment, emphasizing the role of extraction procedures and the quality of debonding in improving retention. The study identified key outcomes for orthodontic clinical trials, highlighting orthodontists' preferences for specific retainer types. Moreover, it discussed the impact of sociocultural influences on retention care. Involving patients actively in discussions about whether to end or extend the retention phase was deemed essential. Noteworthy improvements in occlusal outcomes were linked to extraction treatments. Gender and malocclusion severity influenced QoL before and after orthodontic treatment. The degree of improvement observed in the Class III malocclusion group was comparatively lower than that in the Class I and Class II groups. Orthodontic treatment was found to yield favorable psychological outcomes, as evidenced by notable enhancements in self-esteem and social engagement among individuals. Fixed appliances were shown to negatively affect oral health-related quality of life (OHRQoL), particularly for those with aesthetic and functional concerns. A consensus has been reached on the essential themes and outcomes that should be incorporated in clinical trials related to orthodontic retention for non-cleft and non-surgical cases.
PubMed: 38659711
DOI: 10.7759/cureus.58843 -
The Angle Orthodontist May 2024To investigate the dimensional stability of various 3D-printed models derived from resin and plant-based, biodegradable plastics (PLA) under specific storage conditions...
OBJECTIVES
To investigate the dimensional stability of various 3D-printed models derived from resin and plant-based, biodegradable plastics (PLA) under specific storage conditions for a period of up to 21 weeks.
MATERIALS AND METHODS
Four different printing materials, including Draft V2, study model 2, and Ortho model OD01 resins as well as PLA mineral, were evaluated over a 21-week period. Eighty 3D-printed models were divided equally into two groups, with one group stored in darkness and the other exposed to daylight. All models were stored at a constant room temperature (20°C). Measurements were taken at 7-week intervals using the Inspect 3D module in OnyxCeph software (Image Instruments GmbH, Chemnitz, Germany).
RESULTS
Dimensional change was noted for all of the models with shrinkage of up to 0.26 mm over the study period. Most contraction occured from baseline to T1, although significant further contraction also arose from T1 to T2 (P < .001) and T1 to T3 (P < .001). More shrinkage was observed when exposed to daylight overall and for each resin type (P < .01). The least shrinkage was noted with Ortho model OD01 resin (0.16 mm, SD = 0.06), and the highest level of shrinkage was observed for Draft V2 resin (0.23 mm, SD = 0.06; P < .001).
CONCLUSIONS
Shrinkage of 3D-printed models is pervasive, arising regardless of the material used (PLA or resin) and being independent of the brand or storage conditions. Consequently, immediate utilization of 3D printing for orthodontic appliance purposes may be preferable, with prolonged storage risking the manufacture of inaccurate orthodontic retainers and appliances.
Topics: Printing, Three-Dimensional; Orthodontic Retainers; Software; Polyesters; Materials Testing
PubMed: 38639456
DOI: 10.2319/081223-557.1