-
Annals of Vascular Diseases Jun 2024Surgical reconstruction is one of the standard treatments for renal artery aneurysm. However, its intraoperative evaluation is sometimes difficult depending on the...
Surgical reconstruction is one of the standard treatments for renal artery aneurysm. However, its intraoperative evaluation is sometimes difficult depending on the operative field, aneurysm morphology, and peripheral blood vessel distribution. This case demonstrated that after renal artery reconstruction, indocyanine green fluorescence angiography is used to evaluate the results of repairing. This method is useful in visceral aneurysm evaluation not only for assessing reconstructed blood flow but also for confirming tissue perfusion of the renal parenchyma.
PubMed: 38919322
DOI: 10.3400/avd.cr.23-00085 -
Indian Journal of Thoracic and... Jul 2024[This corrects the article DOI: 10.1007/s12055-024-01734-5.].
[This corrects the article DOI: 10.1007/s12055-024-01734-5.].
PubMed: 38919187
DOI: 10.1007/s12055-024-01745-2 -
Scientific Reports Jun 2024Cerebrovascular resistance (CVR) regulates blood flow in the brain, but little is known about the vascular resistances of the individual cerebral territories. We present...
Cerebrovascular resistance (CVR) regulates blood flow in the brain, but little is known about the vascular resistances of the individual cerebral territories. We present a method to calculate these resistances and investigate how CVR varies in the hemodynamically disturbed brain. We included 48 patients with stroke/TIA (29 with symptomatic carotid stenosis). By combining flow rate (4D flow MRI) and structural computed tomography angiography (CTA) data with computational fluid dynamics (CFD) we computed the perfusion pressures out from the circle of Willis, with which CVR of the MCA, ACA, and PCA territories was estimated. 56 controls were included for comparison of total CVR (tCVR). CVR were 33.8 ± 10.5, 59.0 ± 30.6, and 77.8 ± 21.3 mmHg s/ml for the MCA, ACA, and PCA territories. We found no differences in tCVR between patients, 9.3 ± 1.9 mmHg s/ml, and controls, 9.3 ± 2.0 mmHg s/ml (p = 0.88), nor in territorial CVR in the carotid stenosis patients between ipsilateral and contralateral hemispheres. Territorial resistance associated inversely to territorial brain volume (p < 0.001). These resistances may work as reference values when modelling blood flow in the circle of Willis, and the method can be used when there is need for subject-specific analysis.
Topics: Humans; Male; Female; Cerebrovascular Circulation; Hydrodynamics; Vascular Resistance; Middle Aged; Aged; Magnetic Resonance Imaging; Stroke; Carotid Stenosis; Hemodynamics; Computed Tomography Angiography; Circle of Willis; Blood Flow Velocity; Brain
PubMed: 38918589
DOI: 10.1038/s41598-024-65431-4 -
Cureus May 2024Peripheral artery disease (PAD) is the buildup of calcium and fatty deposits in the arterial walls (atherosclerosis). This is an important clinical issue, specifically...
Peripheral artery disease (PAD) is the buildup of calcium and fatty deposits in the arterial walls (atherosclerosis). This is an important clinical issue, specifically in cases with multilevel lesions. A patient underwent sequential angioplasty treatment for major PAD, which was characterized by multilevel lesions affecting both the infrapopliteal arteries. The proximal vessels and infrapopliteal vessels are mostly observed to be affected by PAD, thus the patient likely has PAD localized to the lower leg. In the femoropopliteal segment, lower extremity artery or aortic atherosclerotic occlusive disease can lead to significant outcomes. Severe claudication and pain during rest in both legs were observed in a patient with a history of hypertension and diabetes mellitus. With an angiography, the superficial femoral, popliteal, and tibial arteries have been shown to have major stenoses and occlusions. A progressive treatment was used because of the complexity of the lesions initiating with endovascular revascularization of the superficial femoral artery. The popliteal and tibial arteries were then repaired with angioplasty and stent placement. After the treatment, the patient's symptoms significantly improved, including elimination of their rest discomfort and claudication. Measurements of the ankle-brachial index (ABI) indicated that the affected limbs' perfusion was refined. Six months later, a follow-up angiography revealed intact vessels with no restenosis. This case report shows the successful outcome of recurrent angioplasty in curing complicated multilevel PAD, giving symptomatic relief and maintaining limb perfusion. This research is required to assess the long-term outcomes and longevity of this kind of treatment in patient populations that are comparable to others.
PubMed: 38915963
DOI: 10.7759/cureus.60982 -
Clinical Kidney Journal Jun 2024The aim of this work was to create and evaluate a preoperative non-contrast-enhanced (CE) magnetic resonance imaging (MRI)/angiography (MRA) protocol to assess renal...
BACKGROUND
The aim of this work was to create and evaluate a preoperative non-contrast-enhanced (CE) magnetic resonance imaging (MRI)/angiography (MRA) protocol to assess renal function and visualize renal arteries and any abnormalities in potential living kidney donors.
METHODS
In total, 28 subjects were examined using scintigraphy to determine renal function. In addition, 3D-pseudocontinuous arterial spin labeling (pCASL), a 2D-non-CE electrocardiogram-triggered radial quiescent interval slice-selective (QISS-MRA), and 4D-CE time-resolved angiography with interleaved stochastic trajectories (CE-MRA) were performed to assess renal perfusion, visualize renal arteries and detect any abnormalities. Two glomerular filtration rates [described by Gates (GFR) and according to the Chronic Kidney Disease Epidemiology Collaboration formula (GFR)]. The renal volumes were determined using both MRA techniques.
RESULTS
The mean value of regional renal blood flow (rRBF) on the right side was significantly higher than that on the left. The agreements between QISS-MRA and CE-MRA concerning the assessment of absence or presence of an aberrant artery and renal arterial stenosis were perfect. The mean renal volumes measured in the right kidney with QISS-MRA were lower than the corresponding values of CE-MRA. In contrast, the mean renal volumes measured in the left kidney with both MRA techniques were similar. The correlation between the GFR and rRBF was compared in the same manner as that between GFR and rRBF.
CONCLUSION
The combination of pCASL and QISS-MRA constitute a reliable preoperative protocol with a total measurement time of <10 min without the potential side effects of gadolinium-based contrast agents or radiation exposure.
PubMed: 38915436
DOI: 10.1093/ckj/sfae101 -
Vascular Specialist International Jun 2024Paradoxical embolism through the foramen ovale is a rare and devastating event requiring urgent treatment. Herein, we present the case of a 23-year-old male who...
Paradoxical embolism through the foramen ovale is a rare and devastating event requiring urgent treatment. Herein, we present the case of a 23-year-old male who presented with a pulmonary embolism complicated by a left renal artery paradoxical embolism. Urgent vacuum-assisted thrombo-aspiration restored normal perfusion of the left kidney within 5 hours. The patient had a patent foramen ovale and heterozygous thrombophilia. However, a radioisotopic scan performed 2 years later revealed an unexpected decrease in left renal perfusion. Therefore, despite the angiographic success, functional evaluation using a renal scan should be performed to assess renal function.
PubMed: 38915224
DOI: 10.5758/vsi.240022 -
Journal of Korean Neurosurgical Society Jun 2024Hemifacial spasm (HFS) is treated by a surgical procedure called microvascular decompression (MVD). However, HFS re-appearing phenomenon after surgery, presenting as...
Prediction of hemifacial spasm re-appearing phenomenon after microvascular decompression surgery in patients with hemifacial spasm using dynamic susceptibility contrast perfusion MRI.
OBJECTIVE
Hemifacial spasm (HFS) is treated by a surgical procedure called microvascular decompression (MVD). However, HFS re-appearing phenomenon after surgery, presenting as early recurrence, is experienced by some patients after MVD. Dynamic susceptibility contrast (DSC) perfusion MRI and two analytical methods: receiver operating characteristic (ROC) curve and machine learning, were used to predict early recurrence in this study.
METHODS
This study enrolled sixty patients who underwent MVD for HFS. They were divided into two groups: Group A consisted of 32 patients who had early recurrence, and Group B consisted of 28 patients who had no early recurrence of HFS. DSC perfusion MRI was undergone by all patients before the surgery to obtain the several parameters. ROC curve and machine learning methods were used to predict early recurrence using these parameters.
RESULTS
Group A had significantly lower relative cerebral blood flow (rCBF) than Group B in most of the selected brain regions, as shown by the region-of-interest (ROI)-based analysis. By combining three extraction fraction (EF) values at middle temporal gyrus, posterior cingulate, and brainstem, with age, using naive Bayes machine learning method, the best prediction model for early recurrence was obtained. This model had an area under the curve (AUC) value of 0.845.
CONCLUSION
By combining EF values with age or sex using machine learning methods, DSC perfusion MRI can be used to predict early recurrence before MVD surgery. This may help neurosurgeons to identify patients who are at risk of HFS recurrence and provide appropriate postoperative care.
PubMed: 38915211
DOI: 10.3340/jkns.2024.0055 -
Scientific Reports Jun 2024The rapid perfusion of cerebral arteries leads to a significant increase in intracranial blood volume, exposing patients with traumatic brain injury to the risk of...
Assessment of cerebrovascular alterations induced by inflammatory response and oxidative-nitrative stress after traumatic intracranial hypertension and a potential mitigation strategy.
The rapid perfusion of cerebral arteries leads to a significant increase in intracranial blood volume, exposing patients with traumatic brain injury to the risk of diffuse brain swelling or malignant brain herniation during decompressive craniectomy. The microcirculation and venous system are also involved in this process, but the precise mechanisms remain unclear. A physiological model of extremely high intracranial pressure was created in rats. This development triggered the TNF-α/NF-κB/iNOS axis in microglia, and released many inflammatory factors and reactive oxygen species/reactive nitrogen species, generating an excessive amount of peroxynitrite. Subsequently, the capillary wall cells especially pericytes exhibited severe degeneration and injury, the blood-brain barrier was disrupted, and a large number of blood cells were deposited within the microcirculation, resulting in a significant delay in the recovery of the microcirculation and venous blood flow compared to arterial flow, and this still persisted after decompressive craniectomy. Infliximab is a monoclonal antibody bound to TNF-α that effectively reduces the activity of TNF-α/NF-κB/iNOS axis. Treatment with Infliximab resulted in downregulation of inflammatory and oxidative-nitrative stress related factors, attenuation of capillary wall cells injury, and relative reduction of capillary hemostasis. These improved the delay in recovery of microcirculation and venous blood flow.
Topics: Animals; Oxidative Stress; Rats; Intracranial Hypertension; Male; Tumor Necrosis Factor-alpha; Inflammation; Microcirculation; Cerebrovascular Circulation; Rats, Sprague-Dawley; Brain Injuries, Traumatic; Infliximab; Disease Models, Animal; Blood-Brain Barrier; Reactive Oxygen Species; Reactive Nitrogen Species; Microglia
PubMed: 38914585
DOI: 10.1038/s41598-024-64940-6 -
Resuscitation Plus Sep 2024Minimizing cardiac arrest times is critical in extracorporeal cardiopulmonary resuscitation (ECPR). Pre-primed extra corporeal membrane oxygenator (ECMO) is used for...
AIM
Minimizing cardiac arrest times is critical in extracorporeal cardiopulmonary resuscitation (ECPR). Pre-primed extra corporeal membrane oxygenator (ECMO) is used for this, but knowledge is limited to experimental studies. We prospectively investigated oxygenator function and sterility in dry plus wet pre-priming in a clinical setting.
METHODS
This prospective clinical study included 107 ECMO circuits used at Sahlgrenska University Hospital between October 2019 and December 2021. Circuits underwent dry set-up, followed by wet priming when the previous wet-primed circuit was used. Sterility was assessed by culturing the priming solution. Oxygenator function parameters, including sweep gas flow, fraction of oxygen (FiO), and oxygenator resistance, were analyzed at ECMO initiation and during treatment using linear mixed models.
RESULTS
Median total set-up time was 14 days (range 0-97), with a median wet prime time of 6 days (range 0-57). 103 of 105 circuits with culture results were negative, two showed bacterial growth (coagulase-negative staphylococci and ). Wet prime time did not significantly affect initial oxygenator function. Oxygenator resistance and FiO increased during ECMO treatment (0.035 mmHg/L min (95 % confidence interval (CI) 0.015-0.055) < 0.001, and 2.19 % (0.92-3.46) = 0.009), but these changes were unrelated to wet prime time.
CONCLUSION
Wet pre-priming of ECMO circuits for up to 57 days did not affect oxygenator function. The low incidence of bacterial growth (1.9 %) suggests that pre-primed ECMO generally maintain sterility and can facilitate rapid ECPR initiation. However, bacterial growth highlights the need for caution in non-urgent cases. Culturing the circuit at initiation can mitigate this risk.
PubMed: 38912528
DOI: 10.1016/j.resplu.2024.100680 -
Proceedings of SPIE--the International... Feb 2024Arterial spin labeling (ASL) perfusion MRI is the only non-invasive imaging technique for quantifying regional cerebral blood flow (CBF), which is a fundamental...
Arterial spin labeling (ASL) perfusion MRI is the only non-invasive imaging technique for quantifying regional cerebral blood flow (CBF), which is a fundamental physiological variable. ASL MRI has a relatively low signal-to-noise-ratio (SNR). In this study, we proposed a novel ASL denoising method by simultaneously exploiting the inter- and intra-receive channel data correlations. MRI including ASL MRI data have been routinely acquired with multi-channel coils but current denoising methods are designed for denoising the coil-combined data. Indeed, the concurrently acquired multi-channel images differ only by coil sensitivity weighting and random noise, resulting in a strong low-rank structure of the stacked multi-channel data matrix. In our method, this matrix was formed by stacking the vectorized slices from different channels. Matrix rank was then approximately measured through the logarithm-determinant of the covariance matrix. Notably, our filtering technique is applied directly to complex data, avoiding the need to separate magnitude and phase or divide real and imaginary data, thereby ensuring minimal information loss. The degree of low-rank regularization is controlled based on the estimated noise level, striking a balance between noise removal and texture preservation. A noteworthy advantage of our framework is its freedom from parameter tuning, distinguishing it from most existing methods. Experimental results on real-world imaging data demonstrate the effectiveness of our proposed approach in significantly improving ASL perfusion quality. By effectively mitigating noise while preserving important textural information, our method showcases its potential for enhancing the utility and accuracy of ASL perfusion MRI, paving the way for improved neuroimaging studies and clinical diagnoses.
PubMed: 38912380
DOI: 10.1117/12.3005223