Clinical Oral Implants Research Sep 2023In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year?
MATERIALS AND METHODS
This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487).
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material.
CONCLUSIONS
Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Topics: Humans; Titanium; Dental Implants; Alloys; Aluminum Oxide
PubMed: 37750527
DOI: 10.1111/clr.14159 -
Clinical Oral Implants Research Sep 2023For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other... (Meta-Analysis)
Meta-Analysis Review
OBJECTIVES
For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years.
MATERIALS AND METHODS
An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD.
RESULTS
From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients).
CONCLUSIONS
After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.
Topics: Humans; Dental Implants; Prospective Studies; Retrospective Studies; Titanium; Bone Diseases, Metabolic
PubMed: 37750521
DOI: 10.1111/clr.14133 -
Acta Biomaterialia Oct 2023Titanium (Ti) and Ti alloys are commonly used in dental implants, which have good biocompatibility, mechanical strength, processability, and corrosion resistance.... (Review)
Review
Titanium (Ti) and Ti alloys are commonly used in dental implants, which have good biocompatibility, mechanical strength, processability, and corrosion resistance. However, the surface inertia of Ti implants leads to delayed integration of Ti and new bone, as well as problems such as aseptic loosening and inadequate osseointegration. Magnesium (Mg) ions can promote bone regeneration, and many studies have used Mg-containing materials to modify the Ti implant surface. This systematic review summarizes the methods, effects, and clinical applications of surface modification of Ti implants with Mg-containing coatings. Database collection was completed on Janury 1, 2023, and a total of 29 relevant studies were ultimately included. Mg can be compounded with different materials and coated to the surface of Ti implants using different methods. In vitro and in vivo experiments have shown that Mg-containing coatings promote cell adhesion and osteogenic differentiation. On the one hand, the surface roughness of implants increases with the addition of Mg-containing coatings, which is thought to have an impact on the osseointegration of the implant. On the other hand, Mg ions promote cell attachment through binding interactions between the integrin family and FAK-related signaling pathways. And Mg ions could induce osseointegration by activating PI3K, Notch, ERK/c-Fos, BMP-4-related signaling pathways and TRPM7 protein channels. Overall, Mg-based coatings show great potential for the surface modification of Ti implants to promote osseointegration. STATEMENT OF SIGNIFICANCE: The inertia surface of titanium (Ti) implants leads to delayed osseointegration. Magnesium (Mg) ions, known for promoting bone regeneration, have been extensively studied to modify the surface of Ti implants. However, no consensus has been reached on the appropriate processing methods, surface roughness and effective concentration of Mg-containing coatings for osseointegration. This systematic review focus on the surface modification of Ti implants with Mg-containing compounds, highlighting the effects of Mg-containing coatings on the surface properties of Ti implants and its associated mechanisms. Besides, we also provide an outlook on future directions to promote the clinical application of Mg-modified implants.
Topics: Coated Materials, Biocompatible; Ions; Magnesium; Osseointegration; Osteogenesis; Surface Properties; Titanium
PubMed: 37517617
DOI: 10.1016/j.actbio.2023.07.048 -
European Journal of Orthodontics Sep 2023Comparing computer-aided design and computer-aided manufacturing (CAD/CAM) fixed retainers and conventional fixed retainers for their effectiveness in orthodontic... (Meta-Analysis)
Meta-Analysis
OBJECTIVE
Comparing computer-aided design and computer-aided manufacturing (CAD/CAM) fixed retainers and conventional fixed retainers for their effectiveness in orthodontic patients using systematic review and meta-analysis of literature.
SEARCH METHODS
A comprehensive search was conducted in MEDLINE, Web of Science, EMBASE, Scopus, Cochrane's CENTRAL, Google Scholar, Ovid, and LILACS up to May 2023, with no language or date restrictions.
SELECTION CRITERIA
Only randomized clinical trials (RCTs) that complied with PICO questions were included, and the Cochrane Risk of Bias 2.0 (RoB 2) tool was used to assess the risk of bias in the included studies.
DATA COLLECTION AND ANALYSIS
Using custom-piloted forms, relevant data were retrieved from the included studies. Then a random-effects inverse variance meta-analysis was used to pool the results. Primary outcomes were stability of treatment results measured through dental cast measurements and periodontal status, while secondary outcomes were failure rates and patient-reported outcomes.
RESULTS
Seven RCTs with 601 participants were included in the review. In the short term (≤6 months), the meta-analysis showed no significant differences in inter-canine distance or arch length between CAD/CAM and conventional fixed retainers in mandibular retainers. However, for Little's irregularity index, single-stranded stainless-steel retainers were notably worse than Ni-Ti CAD/CAM retainers at 3 and 6 months, while multi-stranded stainless-steel retainers only diverged from CAD/CAM at the 6-month milestone, despite the overall clinical inconsequence of these changes. CAD/CAM retainers were associated with a lower plaque index than traditional retainers but no significant difference in gingival index. Failure rates did not differ significantly between CAD/CAM and other types of retainers in mandibular retainers. Nonetheless, one study had a high amount of CAD/CAM retainer failures leading to the study being stopped.
CONCLUSIONS
In the short term, CAD/CAM fixed retainers show promise as an alternative to traditional retainers. They may enhance periodontal health, as indicated by lower plaque index scores than conventional retainers. However, extensive research is needed to determine the long-term durability and effectiveness of CAD/CAM retainers in orthodontic treatment, particularly regarding their failure rate. Until comprehensive evidence is available, the use of CAD/CAM retainers should be tailored for each case.
REGISTRATION
The protocol for this systematic review was registered at PROSPERO with the ID CRD42023412741.
Topics: Humans; Network Meta-Analysis; Orthodontic Retainers; Orthodontic Appliances, Fixed; Computer-Aided Design; Stainless Steel
PubMed: 37471113
DOI: 10.1093/ejo/cjad033 -
Journal of the Mechanical Behavior of... Sep 2023The purpose of this systematic review and meta-analysis was to compare the results of tribocorrosion in titanium alloys of dental implants submitted to surface treatment... (Meta-Analysis)
Meta-Analysis Review
The purpose of this systematic review and meta-analysis was to compare the results of tribocorrosion in titanium alloys of dental implants submitted to surface treatment with those whose treatment was not performed. An electronic search was carried out on the MEDLINE (PubMed), Web of Science, Virtual Health Library and Scopus databases. The search strategy used was PECO: Participants (P): titanium alloys; Exposure (E): surface treatment; Comparison (C): absence of surface treatment; and Result/Outcome (O): tribocorrosion. The search found a total of 336 articles, where 27 was selected by title or abstract, resulted to 10 after reading in full. The treatments that formed the rutile layer had better tribological results and therefore better protected the material from mechanical and chemical degradation, contrary to the technique with the addition of nanotubes. It was concluded that the surface treatment proves to be efficient to protect metals from mechanical and chemical wear.
Topics: Humans; Alloys; Titanium; Corrosion; Dental Implants; Surface Properties
PubMed: 37423010
DOI: 10.1016/j.jmbbm.2023.106008 -
International Journal of Implant... Jul 2023The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated.
METHODS
Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures.
RESULTS
Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36-141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients' reported increased satisfaction with ZIs.
CONCLUSIONS
ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.
Topics: Humans; Dental Implantation, Endosseous; Dental Implants; Prosthesis Failure; Titanium; Treatment Outcome; Alloys
PubMed: 37405545
DOI: 10.1186/s40729-023-00479-x -
Neurospine Jun 2023Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2...
Interbody fusion is a workhorse technique in lumbar spine surgery that facilities indirect decompression, sagittal plane realignment, and successful bony fusion. The 2 most commonly employed cage materials are titanium (Ti) alloy and polyetheretherketone (PEEK). While Ti alloy implants have superior osteoinductive properties they more poorly match the biomechanical properties of cancellous bones. Newly developed 3-dimensional (3D)-printed porous titanium (3D-pTi) address this disadvantage and are proposed as a new standard for lumbar interbody fusion (LIF) devices. In the present study, the literature directly comparing 3D-pTi and PEEK interbody devices is systematically reviewed with a focus on fusion outcomes and subsidence rates reported in the in vitro, animal, and human literature. A systematic review directly comparing outcomes of PEEK and 3D-pTi interbody spinal cages was performed. PubMed, Embase, and Cochrane Library databases were searched according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. Mean Newcastle-Ottawa Scale score for cohort studies was 6.4. A total of 7 eligible studies were included, comprising a combination of clinical series, ovine animal data, and in vitro biomechanical studies. There was a total population of 299 human and 59 ovine subjects, with 134 human (44.8%) and 38 (64.4%) ovine models implanted with 3D-pTi cages. Of the 7 studies, 6 reported overall outcomes in favor of 3D-pTi compared to PEEK, including subsidence and osseointegration, while 1 study reported neutral outcomes for device related revision and reoperation rate. Though limited data are available, the current literature supports 3D-pTi interbodies as offering superior fusion outcomes relative to PEEK interbodies for LIF without increasing subsidence or reoperation risk. Histologic evidence suggests 3D-Ti to have superior osteoinductive properties that may underlie these superior outcomes, but additional clinical investigation is merited.
PubMed: 37401063
DOI: 10.14245/ns.2346244.122 -
Journal of Esthetic and Restorative... Dec 2023The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. (Review)
Review
OBJECTIVE
The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning.
MATERIALS AND METHODS
An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded.
RESULTS
A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications.
CONCLUSIONS
The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions.
CLINICAL SIGNIFICANCE
ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Topics: Dental Implants; Dental Impression Technique; Computer-Aided Design; Research Design; Imaging, Three-Dimensional
PubMed: 37381677
DOI: 10.1111/jerd.13074 -
Antibiotics (Basel, Switzerland) Jun 2023Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level.... (Review)
Review
Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.
PubMed: 37370313
DOI: 10.3390/antibiotics12060994 -
The British Journal of Oral &... Jul 2023Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The... (Meta-Analysis)
Meta-Analysis Review
Evidence is limited on whether titanium-zirconium alloy, narrow-diameter implants (Ti-Zr NDIs) have promising clinical outcomes when used to support single crowns. The purpose of this systematic review and meta-analysis was to evaluate clinical evidence, including survival rates, success rates, and marginal bone loss (MBL) on Ti-Zr NDIs that support single crowns. An extensive search was performed in the databases of PubMed/MEDLINE, Scopus, Embase, and the Cochrane Library for studies published in English up to April 2022. Only peer-reviewed clinical studies with at least 10 patients and a follow-up time of at least 12 months were included. Risk of bias in each study was assessed and data extraction was carried out independently by two reviewers. The outcome variables were survival rates, success rates, and MBL. The search returned 779 results. Eight studies were identified for qualitative analysis and seven for quantitative synthesis. Overall, a total of 256 Ti-Zr NDIs were included. Cumulative implant survival rates and success rates were 97.5% (95% confidence interval (CI): 94.5% to 98.9%) and 97.2% (95% CI: 94.2% to 98.7%), respectively, over a maximum follow-up period of 36 months, with no difference between Ti-Zr NDIs and commercial pure titanium (cpTi) implants. Cumulative mean (SD) MBL was 0.44 (0.04) mm (95% CI: 0.36 to 0.52) after one year. Meta-analysis of MBL indicated a mean difference of 0.02 mm (95% CI: -0.23 to 0.10), with no differences between Ti-Zr NDIs and cpTi implants. Short-term results of Ti-Zr NDIs for single-crown restorations are quite promising, although the number of published studies and follow-up periods are insufficient to determine the real benefit for single crowns. Long-term, follow-up clinical studies are needed to verify the excellent clinical performance of Ti-Zr NDIs.
Topics: Humans; Titanium; Zirconium; Dental Prosthesis Design; Alloys; Crowns; Dental Implants; Dental Restoration Failure
PubMed: 37331853
DOI: 10.1016/j.bjoms.2023.05.005