Heliyon Mar 2023There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and...
There is no consensus in the literature about the best non-cytotoxic antibacterial surface treatment for dental implants. Critically evaluate the existing literature and answer the question: "which surface treatment for dental implants made of titanium and its alloys has the greatest non-cytotoxic antibacterial activity for osteoblastic cells?" This systematic review was registered in the Open Science Framework (osf.io/8fq6p) and followed the Preferred Reporting Items for Systematic Review and Meta-analysis Protocols. The search strategy was applied to four databases. Articles were selected that evaluated in both studies the properties of 1) antibacterial activity and 2) cytotoxicity on osteoblastic cells of titanium and their alloy dental implants when treated superficially. Systematic reviews, book chapters, observational studies, case reports, articles that studied non-dental implants, and articles that evaluated only the development of surface treatment were excluded. The Joanna Briggs Institute, a quasi-experimental study assessment tool, was adapted to assess the risk of bias. The search strategy found 1178 articles in the databases after removing duplicates in EndNote Web, resulting in 1011 articles to be evaluated by title and abstract, of which 21 were selected for full reading, of which 12 were included by eligibility criteria, and nine were excluded. Quantitative synthesis could not be performed due to the heterogeneity of the data (surface treatment, antibacterial assay, bacteria strain, cell viability assay, and cell type). Risk of bias assessment showed that ten studies were classified as low risk and two studies as moderate risk. The evaluated literature allowed us to conclude that: 1) The literature surveyed did not allow answering the question due to the heterogeneity of the studies; 2) Ten of the 12 studies evaluated presented surface treatments with non-cytotoxic antibacterial activity; 3) Adding nanomaterials, QPEI, BG, and CS, reduce the chances of bacterial resistance by controlling their adhesion by electrical forces.
PubMed: 36895374
DOI: 10.1016/j.heliyon.2023.e13693 -
The Journal of Prosthetic Dentistry Mar 2023Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM)... (Review)
Review
STATEMENT OF PROBLEM
Providing a removable partial denture (RPD) can be a complex, time-consuming, and error-prone procedure. Computer-aided design and computer-aided manufacturing (CAD-CAM) techniques have shown promising clinical outcomes; however, the influence of manufacturing techniques on the properties of RPD components is unclear.
PURPOSE
The purpose of this systematic review was to determine the accuracy and mechanical properties of RPD components fabricated with conventional and digital methods.
MATERIAL AND METHODS
This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) and was registered on the international prospective register of systematic reviews (PROSPERO) database (CRD42022353993). An electronic search was conducted on PubMed/MEDLINE, Scopus, Web of Science, and the Cochrane Library in August 2022. Only in vitro studies comparing the digital with the lost-wax casting technique were included. The quality of the studies was assessed by using the methodological index for nonrandomized studies (MINORS) scale.
RESULTS
Of the 17 selected studies, 5 evaluated the accuracy of RPD components as well as the mechanical properties, 5 studies evaluated only the component accuracy, and another 7 evaluated only the mechanical properties. The accuracy was similar regardless of the technique, with discrepancies within clinically acceptable values (50 to 426.3 μm). The surface roughness was higher for 3D-printed clasps and lower for milled clasps (P<.05). The metal alloy significantly influenced the porosity, with the highest number of pores obtained by casting for Ti clasps and by rapid prototyping for Co-Cr clasps.
CONCLUSIONS
In vitro studies showed that the digital technique provided similar accuracy to that of the conventional technique within a clinically acceptable range. The manufacturing technique influenced the mechanical properties of RPD components.
PubMed: 36870892
DOI: 10.1016/j.prosdent.2023.01.032 -
Expert Review of Medical Devices Mar 2023While 3D printing of bone models for preoperative planning or customized surgical templating has been successfully implemented, the use of patient-specific additively...
INTRODUCTION
While 3D printing of bone models for preoperative planning or customized surgical templating has been successfully implemented, the use of patient-specific additively manufactured (AM) implants is a newer application not yet well established. To fully evaluate the advantages and shortcomings of such implants, their follow-up results need to be evaluated.
AREA COVERED
This systematic review provides a survey of the reported follow-ups on AM implants used for oncologic reconstruction, total hip arthroplasty both primary and revision, acetabular fracture, and sacrum defects.
EXPERT OPINION
The review shows that Titanium alloy (Ti4AL6V) is the most common type of material system used due to its excellent biomechanical properties. Electron beam melting (EBM) is the predominant AM process for manufacturing implants. In almost all cases, porosity at the contact surface is implemented through the design of lattice or porous structures to enhance osseointegration. The follow-up evaluations show promising results, with only a small number of patients suffering from aseptic loosening, wear, or malalignment. The longest reported follow-up length was 120 months for acetabular cages and 96 months for acetabular cups. The AM implants have proven to serve as an excellent option to restore premorbid skeletal anatomy of the pelvis.
Topics: Humans; Acetabulum; Follow-Up Studies; Osseointegration; Porosity; Prosthesis Design; Pelvic Bones; Patient-Specific Modeling; Sacrum; Biomechanical Phenomena; Prostheses and Implants
PubMed: 36860182
DOI: 10.1080/17434440.2023.2183839 -
American Journal of Infection Control Sep 2023Hospital-acquired infections (HAIs) are a significant clinical and economic burden on health systems worldwide. Copper alloys have been certified by the US EPA as solid... (Review)
Review
INTRODUCTION
Hospital-acquired infections (HAIs) are a significant clinical and economic burden on health systems worldwide. Copper alloys have been certified by the US EPA as solid antimicrobial materials, but their effectiveness in reducing HAIs is not well established OBJECTIVES: This systematic review aimed to assess copper surfaces in situ efficacy in reducing health care's microbial burden compared to control surfaces.
MATERIALS AND METHODS
A literature search was conducted using three electronic databases: Web of Science, PubMed, and Scopus, with the keywords "copper" and "surfaces" and "antimicrobial" and "antibacterial" and "infections." Studies from 2010 to 2022 were included. The quality of the studies was independently screened and assessed using the Newcastle Ottawa Scale.
RESULTS
A total of 56 articles were screened, with 8 included in the review and 7, added from references. Two third of the studies report a significant reduction in the microbial burden on copper objects compared to control objects. The 2 studies with the highest scores on NOS evaluation indicated that using copper or copper alloys in healthcare settings can effectively decrease the number of bacterial contaminations on touch surfaces.
CONCLUSIONS
The results suggest the potential effectiveness of copper as a preventive tool in healthcare facilities, but further studies and longer trials are needed to establish a relationship between copper and reduced nosocomial infections.
Topics: Humans; Copper; Anti-Infective Agents; Health Facilities; Cross Infection; Alloys; Delivery of Health Care
PubMed: 36842712
DOI: 10.1016/j.ajic.2023.02.010 -
Heliyon Dec 2022Critically analyzed the existing literature to answer the question "What is the influence of roughness of surfaces for dental implants obtained by additive manufacturing...
OBJECTIVE
Critically analyzed the existing literature to answer the question "What is the influence of roughness of surfaces for dental implants obtained by additive manufacturing compared to machined on osteoblastic cell adhesion and proliferation?"
DESIGN
This systematic review followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and was registered in the Open Science Framework. The personalized search strategy was applied to Embase, Pub Med, Scopus, and Science Direct databases and Google Scholar and ProQuest grey literature. The selection process was carried out in two stages independently by two reviewers according to the eligibility criteria. The risk of bias was analyzed using a checklist of important parameters to be considered.
RESULTS
When applying the search strategy on databases 223 articles were found, after removing the duplicates, 171 were analyzed by title and abstract of which 25 were selected for full reading, of these, 6 met the eligibility criteria. 2 studies were included from the reference list totaling 8 articles included in this systematic review and none were included from the Grey Literature. 7 had a low risk of bias and 1 moderate.
CONCLUSIONS
1) Roughness is a property that must be analyzed and correlated with the chemical composition, intrinsic to the alloy and resulting from the surface treatment; morphology of topographic peaks and valleys; printing technique and its parameters; 2) Need for more studies on the biomolecular level to elucidate the mechanism by which the roughness and the morphology of topographical peaks and valleys descriptive of roughness influence osteoblastic adhesion and proliferation.
PubMed: 36643331
DOI: 10.1016/j.heliyon.2022.e12505 -
Journal of Clinical Neuroscience :... Jan 2023Surgical approaches in adult spinal deformity are associated with high rates of adverse events including hardware failure and rod fracture. Recently, some reports have... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Surgical approaches in adult spinal deformity are associated with high rates of adverse events including hardware failure and rod fracture. Recently, some reports have emerged comparing multiple-rod constructs with 2-rod constructs suggesting potential benefits with the former. However, these have been limited by variability in observed outcomes, which have limited the change of paradigm in adult spinal deformity surgery.
OBJECTIVE
To compare the rate of rod fracture, pseudoarthrosis, proximal junctional kyphosis and re-operation between 2-RC and M-RC.
METHODS
MEDLINE/Pubmed, Web of Science and Embase were searched without language restrictions for relevant articles from inception until October 2021. All observational cohort studies assessing patients with ADS undergoing 3-column osteotomy and comparing 2-RC with M-RC procedures on pseudarthrosis, rod fracture, kyphosis or reoperation were included. Data were independently extracted by 2 authors. Random-effects and Bayesian meta-analysis were used.
RESULTS
Six primary studies met inclusion criteria, yielding a total of 448 participants, with 223 receiving 2-RC and 225 M-RC. The random-effects meta-analysis pointed to a significantly lower risk of rod fracture associated with M-RC (RR = 0.43, 95 %CI = 0.28-0.66), with moderate heterogeneity being observed (I = 20 %, p = 0.28). The random-effects meta-analysis pointed to a lower risk of pseudoarthrosis with M-RC than with 2-RC (RR = 0.49, CI = 0.28-0.84, to a lower rate of re-operation with M-RC than with 2-RC (RR = 0.52, CI = 0.28-0.97) and to a similar rate of proximal junctional kyphosis between 2-RC and M-RC patients (RR = 0.91, CI = 0.60-1.39). Low heterogeneity was observed for studies comparing pseudoarthrosis (I = 9 %, p = 0.35), re-operation (I = 0 %, p = 0.41) and proximal junctional kyphosis (I = 0 %, p = 0.85).
DISCUSSION
These findings suggest that multiple rod-fracture constructs are associated with lower rates of rod fracture, re-operation rates, pseudoarthrosis but not proximal junctional kyphosis. Future studies should address the impact of other modulators of heterogeneity such as body mass index, metal alloys and length of the constructs.
Topics: Humans; Adult; Postoperative Complications; Pseudarthrosis; Bayes Theorem; Kyphosis; Cohort Studies; Fractures, Bone; Spinal Fusion; Retrospective Studies
PubMed: 36459919
DOI: 10.1016/j.jocn.2022.11.011 -
Revista Da Associacao Medica Brasileira... 2022
Topics: Humans; Alloys; Stents
PubMed: 36449763
DOI: 10.1590/1806-9282.222D6811 -
The Journal of Prosthetic Dentistry Nov 2022Given the wide use of cobalt-chromium (Co-Cr) alloys, especially for removable partial dentures, and the importance of chemical solutions to complement the cleaning of... (Review)
Review
STATEMENT OF PROBLEM
Given the wide use of cobalt-chromium (Co-Cr) alloys, especially for removable partial dentures, and the importance of chemical solutions to complement the cleaning of dental prostheses, safe disinfection products should be identified for the regular decontamination of Co-Cr dental prostheses.
PURPOSE
The purpose of this systematic review of in vitro studies was to determine the effects on the properties of Co-Cr dental alloys of the various chemical agents used to clean dental prostheses.
MATERIAL AND METHODS
In vitro studies were included based on a literature search conducted in March 2022 in the Medline/PubMed, SCOPUS, Web of Science, Virtual Health Library, and Embase databases. Independent reviewers performed the search, selection, extraction, and analysis of the data. The review was performed based on the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. The quality of the included articles was evaluated by using parameters adapted from the Consolidated Standards of Reporting Trials (CONSORT) guidelines, and the risk of bias analysis was performed based on previous studies.
RESULTS
Among the 15 included studies, the chemical agents evaluated were alkaline peroxides and hypochlorites, mouthwashes containing cetylpyridinium chloride and chlorhexidine, diluted acids, and enzymes. Some peroxides produced increased ion release, surface roughness, and mass loss of the alloys. The hypochlorites were responsible for the greatest surface corrosion, yielding dark stains, rough regions, and depressions. Acetic and peracetic acids and mouthwashes containing chlorhexidine and cetylpyridinium did not produce significant changes in Co-Cr alloys. Most studies presented moderate risk of bias.
CONCLUSIONS
According to the included studies, mouth rinses containing cetylpyridinium chloride or chlorhexidine and solutions with acetic and peracetic acid could be safely used to chemically sanitize Co-Cr prostheses. Alkaline peroxides should be used with caution, and alkaline hypochlorite solutions should be avoided.
PubMed: 36357193
DOI: 10.1016/j.prosdent.2022.09.013 -
Medicina (Kaunas, Lithuania) Sep 2022The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported... (Review)
Review
The aim of the study was to systematically review the overall outcomes of studies comparing the misfit of yttria-stabilized zirconia (Y-TZP) CAD-CAM implant-supported frameworks with frameworks fabricated with other materials and techniques. An electronic literature search of English literature was performed using Google Scholar, Scopus, Web of Science, MEDLINE (OVID), EMBASE, and PubMed, using predetermined inclusion criteria. Specific terms were utilized in conducting a search from the inception of the respective database up to May 2022. After the search strategy was applied, the data were extracted and the results were analyzed. The focused question was: Is the misfit of the implant-supported zirconia CAD-CAM framework lower than that of non-Y-TZP implant-supported fixed restorations? Eleven articles were included for qualitative assessment and critical appraisal in this review. In the included studies, Y-TZP CAD-CAM implant-supported frameworks were compared to Titanium (Ti), Ni-Cr, Co-Cr, PEEK and high-density polymer, and cast and CAD-CAM frameworks. The studies used scanning electron microscopy, one-screw tests, digital or optical microscopy, 3D virtual assessment, and replica techniques for analyzing the misfit of frameworks. Six studies showed comparable misfits among the Y-TZP CAD-CAM frameworks and the controls. Three studies showed higher misfits for the Y-TZP CAD-CAM frameworks, whereas two studies reported lower misfits for Y-TZP CAD-CAM implant frameworks compared to controls. Y-TZP CAD-CAM implant-supported frameworks have comparable misfits to other implant-supported frameworks. However, due to heterogeneity in the methodologies of the included studies, the overall numerical misfit of the frameworks assessed in the reviewed studies is debatable.
Topics: Humans; Titanium; Zirconium; Computer-Aided Design; Polymers
PubMed: 36295507
DOI: 10.3390/medicina58101347 -
Materials (Basel, Switzerland) Oct 2022Immunomodulatory biomaterials have the potential to stimulate an immune response able to promote constructive and functional tissue remodeling responses as opposed to... (Review)
Review
UNLABELLED
Immunomodulatory biomaterials have the potential to stimulate an immune response able to promote constructive and functional tissue remodeling responses as opposed to persistent inflammation and scar tissue formation. As such, the controlled activation of macrophages and modulation of their phenotype through implant surface modification has emerged as a key therapeutic strategy.
METHODS
Online databases were searched for in vitro studies between January 1991 and June 2020 which examined the effect of titanium implant surface topography on the adherent macrophage phenotype at either the gene or protein level.
RESULTS
Thirty-nine studies were subsequently included for review. Although there was significant heterogeneity between studies, treatment of titanium surfaces increased the surface roughness or hydrophilicity, and hence increased macrophage attachment but decreased cell spreading. Physical coating of the titanium surface also tended to promote the formation of cell clusters. Titanium and titanium-zirconium alloy with a micro- or nano-scale rough topography combined with a hydrophilic surface chemistry were the most effective surfaces for inducing an anti-inflammatory phenotype in adherent macrophages, as indicated by significant changes in cytokine gene expression and or cytokine secretion profiles.
CONCLUSIONS
The published data support the hypothesis that incorporation of specific topographical and physiochemical surface modifications to titanium can modulate the phenotypic response of adherent macrophages.
PubMed: 36295379
DOI: 10.3390/ma15207314