-
Heliyon May 2024The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive... (Review)
Review
The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.
PubMed: 38774089
DOI: 10.1016/j.heliyon.2024.e30108 -
International Journal of Implant... May 2024The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific... (Review)
Review
PURPOSE
The purpose of this systematic review was to explore and identify the factors that influence the accuracy of intraoral scanning in implant dentistry, with a specific focus on scan bodies (ISBs).
METHODS
Following the PRISMA 2020 guidelines, this study conducted a thorough electronic search across MedLine, PubMed, and Scopus to identify relevant studies. Articles were screened based on titles, abstracts, and full texts for relevance. The Robins I tool assessed the risk of bias in various study types. Data extraction occurred based on predetermined parameters for studying specimens and assessing outcomes.
RESULTS
16 studies met the specified criteria and were consequently included in the systematic review. Due to variations in variables and methods across the selected studies, statistical comparison of results was not feasible. Therefore, a descriptive review approach was chosen, acknowledging the substantial heterogeneity in the reviewed literature.
CONCLUSIONS
The precision of virtual scan results is contingent upon diverse characteristics of ISBs and implants. These factors encompass their placement within the dental arch, structural design, shape, material composition, color, and the manufacturing system, all of which contribute to scan accuracy. Additionally, considerations such as the intraoral scanner (IOS) type, scanning technique, use of scan aids, inter-implant distance, scan span, and the number of implants warrant evaluation. In the context of capturing implant positions, intraoral scanning with ISBs demonstrates comparable accuracy to traditional impression methods, particularly in single and short-span scenarios. However, the existing data lacks sufficient information on in vivo applications to formulate clinical recommendations.
Topics: Humans; Dental Implants; Imaging, Three-Dimensional; Computer-Aided Design; Dental Implantation, Endosseous; Dental Prosthesis Design
PubMed: 38691258
DOI: 10.1186/s40729-024-00543-0 -
Biomimetics (Basel, Switzerland) Mar 2024The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength... (Review)
Review
The popular immediate dentin sealing (IDS) technique is used to improve the bond strength of indirect restorations. This systematic review assessed whether bond strength is affected by the type of aging conditions, bonding agents, flowable resin composites, impression materials, temporary materials, and/or resin cement used within the IDS procedure. A comprehensive database search of PubMed, Embase, Scopus, Ovid Medline, Web of Sciences, Cochrane Library, Dentistry & Oral Sciences Source, and ProQuest was carried out up to 30 January 2024 without publication year or language limitations. Only in vitro full-texts regarding the effect of IDS on bond strength were included, and the quality of their methods was assessed via a Risk of Bias (RoB) test. In total, 1023 pertinent studies were initially found, and 60 articles were selected for review after screening for the title, abstract, and full texts. IDS application improves the bond strength of indirect restorations to dentin and reduces the negative effects of temporary materials on the bond durability of final indirect restorations. Filled dentin bonding agents or combinations with flowable resin composite are preferred to protect the IDS layer from conditioning procedures.
PubMed: 38534867
DOI: 10.3390/biomimetics9030182 -
Clinical Implant Dentistry and Related... Mar 2024The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely... (Review)
Review
OBJECTIVES
The present study aimed to systematically review the studies comparing the accuracy of intraoral scan (IOS) and conventional implant impressions (CI) in completely edentulous patients.
MATERIALS AND METHODS
Electronic searches were performed in PubMed, Embase and Cochrane CENTRAL up to December 1, 2023. Clinical studies and in vitro studies reporting the accuracy of digital full arch impressions were included. The primary outcome is the 3-dimensional deviations between the study reference models. A risk of bias assessment was performed for clinical studies. A stratified meta-analysis and a single-armed meta-analysis were conducted.
RESULTS
A total of 49 studies were included, with 8 clinical studies and 41 in vitro studies. For comparison between IOS and conventional impressions, studies were categorized into two groups based on the different measurement methods employed: RMS and CMM. In studies using RMS, the result favored the IOS in the unparalleled situation with the mean difference of -99.29 μm (95% CI: [-141.38, -57.19], I = 81%), while the result was opposite with the mean difference of 13.62 μm (95% CI: [10.97, 16.28], I = 26%) when implants were paralleled. For different brands of IOS, the accuracy ranged from 76.11 μm (95% CI: [42.36, 109.86]) to 158.63 μm (95% CI: [-14.68, 331.93]).
CONCLUSIONS
Accuracy of intraoral scan is clinically acceptable in edentulous arches, especially for unparalleled implants. More clinical studies are needed to verify the present finding.
PubMed: 38517307
DOI: 10.1111/cid.13321 -
Cureus Jan 2024The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional... (Review)
Review
The accuracy of definitive impressions has a significant impact on the quality of the final prosthesis. Elastic impression materials are commonly used in the traditional approach to replicate anatomical structures while indirectly fabricating prostheses. Digital impression has gained increasing popularity due to its various advantages, including three-dimensional previsualization, cost-effectiveness, and reduced time consumption. The objective of this study is to evaluate existing studies to provide an overview of the comparative advantages of digital impression techniques over conventional techniques. The review will focus on evaluating the accuracy, patient acceptability, operator preference, and time effectiveness of digital impression techniques in comparison to conventional techniques. The Population, Intervention, Comparison, and Outcome framework served as the basis for this study's search strategy. We conducted a comprehensive literature review by electronically searching articles published between 2000 and 2023 in PubMed, Medline, Cochrane, and the Web of Science. Furthermore, additional manual searches were conducted. The study examined the differences between optical impressions and traditional impressions in terms of accuracy, patient outcomes, and operator outcomes. It included both clinical and preclinical studies as well as randomized controlled trials. In conclusion, this review provides a short summary indicating that digital impressions exhibit comparable accuracy to conventional impressions without any statistically significant difference. This conclusion is based on an evaluation of accuracy, patient preference, and operator preference.
PubMed: 38304652
DOI: 10.7759/cureus.51537 -
The Journal of Prosthetic Dentistry Jan 2024Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is... (Review)
Review
STATEMENT OF PROBLEM
Time and cost are factors that influence a patient's decision on dental prosthetic treatment. Evidence is needed to demonstrate that restoration using digital systems is more rapid and less costly than the conventional process.
PURPOSE
The purpose of this systematic review was to analyze and compare the duration and cost of fixed dental prostheses fabricated using digital and conventional methods from scanning or impression making to delivery of the prosthesis.
MATERIAL AND METHODS
A systematic review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol (PRISMA-P 2015) guidelines. The analysis methods and inclusion criteria were documented in a protocol registered in the Prospective International Register of Systematic Reviews (PROSPERO) (CRD42023458734). The bibliographic search was carried out using PubMed, Cochrane, and PROSPERO databases. The main keywords used were (Prosthodontic OR restorative dentistry OR denture) AND (CAD CAM OR Digital workflow OR Computer Dentistry OR Digital Design) AND (Economic OR cost OR Financial OR time efficiency). Two investigators undertook the different steps of article selection.
RESULTS
A total of 8 articles published between 2010 and 2023 were found for the qualitative synthesis by using the search criteria. Two studies showed that conventional impressions took more time than digital scans for the fabrication of a single crown, and 1 study showed the opposite. One study found that a digital scan was faster than conventional impression making for the fabrication of a 3-unit fixed partial denture, and another study showed the opposite. The dental laboratory technician spent more time on the conventional workflow than the digital workflow for the 3-unit framework and veneering process. No difference was found between conventional and digital workflows for clinical evaluation and chairside adjustment for the fabrication of a single crown. No articles have compared the cost of fixed prostheses.
CONCLUSIONS
The digital pathway can shorten the laboratory process. However, the duration of the impression or scan may vary depending on the technique used. Studies are needed to analyze the cost-effectiveness of the fabrication of tooth-supported restorations.
PubMed: 38302291
DOI: 10.1016/j.prosdent.2024.01.003 -
BMC Oral Health Jan 2024The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS)... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The effectiveness of newly developed elastomeric polymer hybrid siloxane (PVES), which combines the properties of polyethylene (PE) and polyvinyl siloxane (PVS) elastomers, has been a subject of interest in recent studies. This study aimed to assess the physical properties of hybrid PVES materials by analyzing existing data from recent studies on this topic.
METHODS
A systematic literature search was conducted to retrieve peer-reviewed articles published up to February 5, 2023. The population, intervention, comparison, and pertinent outcomes were specified under the PICO framework. The primary data analysis was performed in Microsoft Excel, while statistical analysis used Meta-Essentials.
RESULTS
Of the 1152 articles assessed, 14 met the inclusion criteria. The meta-analysis of the selected studies indicated that polyether (PE) and polyvinyl siloxane (PVS) were highly correlated (two-tailed p-values of 0.000 and 0.001, respectively) with the improved tensile strength of vinyl polyether siloxane (PVES) with a significantly positive effect size. Similarly, the hydrophilic characteristics of PVES were significantly improved compared to those of PE and PVS. PE was a significant contributor to the hydrophilic characteristics of PVES, with a two-tailed p-value of 0.000. The effect size was highly positive for hydrophilicity but showed high heterogeneity. It was also observed that the dimensional accuracy of PVES was comparable to those of PE and PVS, with no statistically significant differences among the three materials.
CONCLUSIONS
PVES showed promising features, with improved tensile strength and hydrophilic characteristics compared to those of PE and PVS.
Topics: Humans; Siloxanes; Polyethylene; Elastomers; Parents
PubMed: 38195442
DOI: 10.1186/s12903-023-03830-1 -
BMC Oral Health Dec 2023The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications... (Meta-Analysis)
Meta-Analysis
PURPOSE OF THE STUDY
The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications using conventional impression methods improve the marginal and internal fit?
BACKGROUND
The incorporation of digital technology in the fabrication of fixed partial dentures (FPDs) has accelerated over the past decade. This study is directed at evaluating the marginal and internal fit of FPDs manufactured using digital approaches compared to conventional techniques. The need for updated data has encouraged this review.
MATERIALS AND METHODS
An electronic search was conducted in PubMed, Scopus, Web of Science, and the Grey Database to identify relevant studies. The Modified Methodological Index for Non-Randomized Studies (MINORS) was used to assess the risk of bias in in vitro experiments. The key results of this meta-analysis were the standard mean differences (SMDs) and 95% confidence intervals (CI) of each main variance, marginal fit, and internal fit between the digital and conventional techniques. Additional analyses were performed to assess the significance of three subgroup parameters: method of digitalization, cement spacer thickness, and span length, and their influence on the fit of the FPDs.
RESULTS
Based on predefined criteria, of the seven articles included in this systematic review, only five were selected for the quantitative data analysis. The marginal fit results were (P = 0.06; SMD: -1.88; 95% CI: - 3.88, 0.11) (P > 0.05) and the internal fit results were (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.10) (P < 0.05). Regarding the subgroup analyses, the method of digitalization subgroup results were (P = 0.35; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.80; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively. The span length results were (P = 0.10; SMD: -1.89; 95% CI: - 3.89, 0.11) for marginal fit and (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.11) for internal fit. The cement spacer thickness (P = 0.01; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.04; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively.
CONCLUSION
Tooth-retained fixed partial dentures FPDs produced by digital scanning and computer-aided design/computer-aided manufacturing (CAD/CAM) systems can significantly enhance the internal fit compared with those manufactured by traditional methods. Intraoral scanners can replace conventional impressions for the fabrication of FPDs because they minimize the operating time and reduce patient pain. Further clinical studies are required to obtain more conclusive results.
SYSTEMATIC REVIEW REGISTRATION
This systematic review and meta-analysis was registered in the International Prospective Register of Systematic Reviews (PROSPERO), registration number CRD42021261397.
Topics: Humans; Dental Marginal Adaptation; Denture, Partial, Fixed; Computer-Aided Design; Research Design; Dental Prosthesis Design
PubMed: 38049754
DOI: 10.1186/s12903-023-03628-1 -
The Journal of Evidence-based Dental... Dec 2023The present study aimed to systematically review the current randomized clinical trials (RCTs) with respect to computer-aided design/computer-aided manufactured... (Meta-Analysis)
Meta-Analysis
COMPARISONS BETWEEN DIGITAL-GUIDED AND NONDIGITAL PROTOCOL IN IMPLANT PLANNING, PLACEMENT, AND RESTORATIONS: A SYSTEMATIC REVIEW AND META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS.
OBJECTIVES
The present study aimed to systematically review the current randomized clinical trials (RCTs) with respect to computer-aided design/computer-aided manufactured (CAD/CAM) techniques in the process of implant planning, placement, and rehabilitation.
MATERIALS AND METHODS
Four independent reviewers conducted an electronic and manual literature search using several databases, including the National Library of Medicine (MEDLINE-PubMed), Cochrane Central Register of Controlled Trials (CENTRAL), and EMBASE. Articles were included if they were RCTs involving the interventions regarding the computer-guided impression, placement, and manufacturing process. The outcomes of interest include clinical and patient-reported outcomes and time efficiency. A meta-analysis was conducted to evaluate the time efficiency, pain severity, accuracy of implant placement, and postsurgery marginal bone level.
RESULTS
A total of 39 and 25 articles were included in the qualitative and quantitative analysis, respectively. The results of the meta-analysis showed that significantly less time was spent performing the digital impression procedure than the conventional impression (P = .002). In addition, the average adjustment time of the final prosthesis was significantly less than the nondigital fabricated prosthesis (P = .0005). Computer-guided groups reported significantly lower painkiller consumption compared to control groups (P = .03).
CONCLUSIONS
Digital impressions and CAD/CAM procedures are time-saving and provide stable and predictable outcomes. Moreover, computer-guided surgery can effectuate an accurate implant placement and less postsurgery discomfort.
Topics: Humans; Dental Implants; Randomized Controlled Trials as Topic; United States
PubMed: 38035896
DOI: 10.1016/j.jebdp.2023.101919 -
Journal of Dentistry Nov 2023To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs).
OBJECTIVE
To review the factors that influence the accuracy of the maxillomandibular relationship at maximum intercuspation (MIP) acquired by using intraoral scanners (IOSs).
MATERIAL AND METHODS
A systematic search was performed using five databases: MEDLINE/PubMed, Cochrane, Embase, World of Science, and Scopus. A manual search was also completed. Studies assessing the factors that influence the MIP acquired by using IOSs were included and organized based on the analyzed factor. Studies were evaluated by applying the Joanna Briggs Institute Critical Appraisal Checklist.
RESULTS
Twenty-nine articles were included. Seven factors have been identified: IOS system, scan extension, edentulous areas, number, location, and extension of occlusal records, occlusal force, tooth mobility, and alignment methods. Nine studies evaluated the influence of IOS system. Four studies assessed the influence of the extension of the arch scan. Three studies evaluated the effect of edentulous spaces. Four studies agreed on the impact of the number, location, and extension of the occlusal records on the MIP accuracy. One study assessed the influence of the occlusal force, showing a smaller average interocclusal space with increased occlusal force. One study evaluated the influence of tooth mobility. Seven studies analyzed the influence of the alignment method on the MIP accuracy.
CONCLUSIONS
Most of the studies reported no difference on the MIP accuracy between half- and complete-arch scans. Areas with 2 or more missing teeth reduce the MIP accuracy. A bilateral and frontal record including 2 teeth or a bilateral posterior occlusal including at least 4-teeth is indicated for maximizing the MIP accuracy.
CLINICAL IMPLICATIONS
When a complete-arch intraoral scans is obtained, a bilateral and frontal record including 2 teeth or a bilateral posterior occlusal record including at least 4-teeth is recommended for maximizing the accuracy of the MIP. When a half-arch intraoral scan is acquired, a posterior occlusal record including at least 4-teeth is indicated for optimizing the accuracy of the MIP.
Topics: Humans; Imaging, Three-Dimensional; Tooth Mobility; Dental Impression Technique; Models, Dental; Dental Arch; Mouth, Edentulous; Computer-Aided Design
PubMed: 37775027
DOI: 10.1016/j.jdent.2023.104718