The Journal of Innovations in Cardiac... Jun 2024Atrial fibrillation (AF) is a prevalent cardiac arrhythmia marked by irregular and frequent tachycardic rhythms in the atria, affecting 1%-2% of the general population.... (Review)
Review
Comparative Profiles of the WATCHMAN™ and Amplatzer™ Cardiac Plug/Amplatzer™ Amulet™ Devices for Left Atrial Appendage Closure in Non-valvular Atrial Fibrillation: A Comprehensive Systematic Review and Meta-analysis.
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia marked by irregular and frequent tachycardic rhythms in the atria, affecting 1%-2% of the general population. The WATCHMAN™ device from Boston Scientific (Marlborough, MA, USA) and the Amplatzer™ Amulet™ device from Abbott (Chicago, IL, USA) are two devices used globally for left atrial appendage closure (LAAC) in non-valvular AF. A systematic search was conducted in PubMed, the Cochrane Library, and Elsevier's ScienceDirect literature databases to identify studies comparing the WATCHMAN™ procedure with Amulet™ device implantation for LAAC in patients with AF. The analyses were conducted using the random-effects model. A total of 20 studies were identified, with 18 falling into the category of observational studies and 2 being randomized controlled trials. A total of 6310 participants were included in this meta-analysis, with 3198 individuals (50.68%) assigned to the WATCHMAN™ procedure group and 3112 individuals (49.32%) allocated to the Amplatzer™ Cardiac Plug (ACP) group. The analysis revealed a higher risk of stroke associated with the WATCHMAN™ technique (relative risk [RR], 1.14), albeit without statistical significance. Conversely, the WATCHMAN™ approach led to a significantly lower risk of cardiac death (RR, 0.44; = .04). Notably, the risks of all-cause mortality (RR, 0.89; 95% confidence interval [CI], 0.73-1.08; = 0%; = .25) and major bleeding (RR, 0.93; 95% CI, 0.65-1.33; = 31%; = .70) were clinically reduced with the WATCHMAN™ procedure, although statistical significance was not achieved. Compared to Amulet™ device implantation, WATCHMAN™ device implantation decreased the risk of cardiac mortality, while the risks of stroke, systemic embolism, all-cause mortality, and major bleeding were not statistically significant.
PubMed: 38948665
DOI: 10.19102/icrm.2024.15061 -
World Neurosurgery Jun 2024When it comes to intracranial aneurysms, the quest for more effective treatments is ongoing. Flow diversion represents a growing advancement in this field. This review... (Review)
Review
BACKGROUND
When it comes to intracranial aneurysms, the quest for more effective treatments is ongoing. Flow diversion represents a growing advancement in this field. This review seeks to compare two variants of the endovascular flow diversion method: the Flow Re-Direction Endoluminal Device (FRED) and the Pipeline Embolization Device (PED).
METHODS
A systematic review was conducted according to the PRISMA guideline using PubMed, Scopus, Web of Science, and Embase, using appropriate terms to compare PED and FRED in double-arm studies from conception until October 8, 2023.
RESULTS
The meta-analysis encompassed 1,769 patients, with a predominance of females (75.5%), among whom 973 patients underwent FRED procedures, while 651 received PED interventions. At six months, complete occlusion rates were 0.62 for FRED and 0.68 for PED (P = 0.68). At one year and the last follow-up, no significant differences were observed between FRED and PED, respectively. Adequate occlusion rates were similar between FRED and PED (0.82 vs 0.79, P = 0.68). FRED showed a statistically significant higher rate of good mRS scores at follow-up (1.00 vs. 0.97, P = 0.03). Hemorrhage and re-treatment rates were higher in PED (P < 0.01) without considering the rupture status of the aneurysms due to the lack of data.
CONCLUSION
This meta-analysis suggests comparable efficacy but different safety profiles between FRED and PED in treating intracranial aneurysms. FRED demonstrated a higher rate of good mRS scores, while PED showed increased hemorrhage and re-treatment rates. Understanding these differences is crucial for informed decision-making in clinical practice.
PubMed: 38925243
DOI: 10.1016/j.wneu.2024.06.100 -
Stroke (Hoboken, N.J.) Mar 2024Currently, endovascular treatment of intracranial aneurysms (ICAs) is limited by low complete occlusion rates. The advent of novel endovascular technology has expanded...
BACKGROUND
Currently, endovascular treatment of intracranial aneurysms (ICAs) is limited by low complete occlusion rates. The advent of novel endovascular technology has expanded the applicability of endovascular therapy; however, the superiority of novel embolic devices over the traditional Guglielmi detachable coils (GDCs) is still debated. We performed a systematic review of literature that reported Raymond-Roy occlusion classification (RROC) rates of modern endovascular devices to determine their immediate and follow-up occlusion effectiveness for the treatment of unruptured saccular ICAs.
METHODS
A search was conducted using electronic databases (PUBMED, Cochrane, ClinicalTrials.gov, Web of Science). We retrieved studies published between 2000-2022 reporting immediate and follow-up RROC rates of subjects treated with different endovascular ICA therapies. We extracted demographic information of the treated patients and their reported angiographic RROC rates.
RESULTS
A total of 80 studies from 15 countries were included for data extraction. RROC rates determined from angiogram were obtained for 21,331 patients (72.5% females, pooled mean age: 58.2 (95% CI: 56.8-59.6), harboring 22,791 aneurysms. The most frequent aneurysm locations were the internal carotid artery (46.4%, 95% CI: 41.9%-50.9%), the anterior communicating artery (26.4%, 95% CI: 22.5%-30.8%), the middle cerebral artery (24.5%, 95% CI:19.2%-30.8%) and the basilar tip (14.4%, 95% CI:11.3%-18.3%). The complete occlusion probability (RROC-I) was analyzed for GDCs, the Woven EndoBridge (WEB), and flow diverters. The RROC-I rate was the highest in balloon-assisted coiling (73.9%, 95% CI: 65.0%-81.2%) and the lowest in the WEB (27.8%, 95% CI:13.2%-49.2%). The follow-up RROC-I probability was homogenous in all analyzed devices.
CONCLUSIONS
We observed that the coil-based endovascular therapy provides acceptable rates of complete occlusion, and these rates are improved in balloon-assisted coils. Out of the analyzed devices, the WEB exhibited the shortest time to achieve >90% probability of follow-up complete occlusion (~18 months). Overall, the GDCs remain the for endovascular treatment of unruptured saccular aneurysms.
PubMed: 38846323
DOI: 10.1161/SVIN.123.001118 -
Annals of Vascular Surgery May 2024Recent randomized controlled trials (RCTs) have demonstrated similar outcomes in terms of ischemic stroke incidence after carotid endarterectomy (CEA) or carotid artery...
New Ischemic Cerebral Lesions in Postprocedural Magnetic Resonance Imaging in Carotid Artery Stenting Versus Carotid Endarterectomy: A Systematic Review and Meta-Analysis.
BACKGROUND
Recent randomized controlled trials (RCTs) have demonstrated similar outcomes in terms of ischemic stroke incidence after carotid endarterectomy (CEA) or carotid artery stenting (CAS) in asymptomatic carotid disease, while CEA seems to be the first option for symptomatic carotid disease. The aim of this meta-analysis is to assess the incidence of silent cerebral microembolization detected by magnetic resonance imaging (MRI) following these procedures.
METHODS
A systematic search was conducted using PubMed, Scopus, and Cochrane databases, including comparative studies involving symptomatic or asymptomatic patients undergoing either CEA or CAS and reporting on new cerebral ischemic lesions in postoperative MRI. The primary outcome was the newly detected cerebral ischemic lesions. Pooled effect estimates for all outcomes were calculated using the random-effects model. Prespecified random effects metaregression and subgroup analysis were conducted to examine the impact of moderator variables on the presence of new cerebral ischemic lesions.
RESULTS
25 studies reporting on a total of 1827 CEA and 1500 CAS interventions fulfilled the eligibility criteria. The incidence of new cerebral ischemic lesions was significantly lower after CEA compared to CAS, regardless of the time of MRI assessment (first 24 hours; OR: 0.33, 95% CI: 0.17-0.64, P < 0.001), (the first 72 hours, OR: 0.25, 95% CI 0.18-0.36, P < 0.001), (generally within a week after the operation; OR: 0.24, 95% CI: 0.17-0.34, P < 0.001). Also, the rate of stroke (OR: 0.38, 95% CI: 0.23-0.63, P < 0.001) and the presence of contralateral new cerebral ischemic lesions (OR: 0.16, 95% CI 0.08-0.32, P < 0.001) were less frequent after CEA. Subgroup analysis based on the study design and the use of embolic protection device during CAS showed consistently lower rates of new lesions after CEA.
CONCLUSIONS
CEA demonstrates significant lower rates of new silent cerebral microembolization, as detected by MRI in postoperative period compared with CAS.
PubMed: 38825067
DOI: 10.1016/j.avsg.2024.05.003 -
Turkish Neurosurgery 2024To compare endovascular coiling and surgical clipping for the evaluation of clinical outcomes in patients with unruptured intracranial aneurysms. (Meta-Analysis)
Meta-Analysis
AIM
To compare endovascular coiling and surgical clipping for the evaluation of clinical outcomes in patients with unruptured intracranial aneurysms.
MATERIAL AND METHODS
We searched MEDLINE, EMBASE, the Cochrane Library and three Chinese domestic electronic databases, namely, Wanfang, CNKI and VIP for studies published between January 1990 and January 2018. We included controlled clinical studies comparing clinical outcomes between surgical clipping and endovascular coiling treatments. Two researchers extracted the data and assessed the quality of the studies, and a meta-analysis was performed using RevMan 5 software.
RESULTS
We analysed a total of 23 controlled clinical studies including 117,796 cases. Meta-analysis demonstrated similar ischaemia rates between clipping and coiling with an odds ratio [OR] of 1.36 (95% CI: 0.77?2.40). The occlusion rate and bleeding risk were higher with clipping than coiling; the pooled ORs were 5.31 (95% CI: 3.07?9.19) and 2.39 (95% CI: 1.82?3.13), respectively. In addition, clipping resulted in a longer hospital stay (OR = 2.90, 95% CI: 2.14?3.65) than coiling did. Patients who underwent clipping had a higher short-term mortality (OR = 1.99, 95% CI: 1.70?2.33) and neurological deficit rate (OR = 2.05, 95% CI: 1.73? 2.44) compared with those who underwent coiling. However, 1 year mortality and deficit rate were similar for both clipping and coiling, with pooled ORs of 0.75 (95% CI: 0.41?1.38) and 0.94 (95% CI: 0.53?1.67), respectively. Funnel plots did not demonstrate a publication bias, with the exception of ischaemic outcome, and sensitivity analysis showed consistent results.
CONCLUSION
Our study demonstrates that coiling is associated with a lower rate of occlusion, shorter hospital stay, lower bleeding risk and lower short-term mortality and morbidity compared with clipping. In terms of ischaemic risk, 1 year mortality and morbidity, coiling and clipping bear a similar risk. In addition, we speculate that surgical clipping may have a better outcome than endovascular coiling in the long term especially in young patients. Further research is needed to confirm our conclusion.
Topics: Humans; Intracranial Aneurysm; Endovascular Procedures; Treatment Outcome; Surgical Instruments; Neurosurgical Procedures; Embolization, Therapeutic
PubMed: 38650551
DOI: 10.5137/1019-5149.JTN.23729-18.1 -
International Angiology : a Journal of... Apr 2024Inferior vena cava (IVC) filters act in preventing pulmonary embolisms (PE). Various complications have been reported with their use. However, a credible urological...
INTRODUCTION
Inferior vena cava (IVC) filters act in preventing pulmonary embolisms (PE). Various complications have been reported with their use. However, a credible urological complication rate, filter characteristics, and clinical presentation has yet to be summarized. Thus, we reported these complications in the form of a systematic review.
EVIDENCE ACQUISITION
A search strategy was designed using PubMed, MEDLINE, and EMBASE on February 10, 2022. The design of this search strategy did not include any language restrictions. The key words (and wildcard terms) used in the search strategy were urolog*, ureter*, bladder, kidney coupled with filter, inferior vena cava, and cava*. Inclusion criteria were: patients older than 18, with previous IVC filter placement, and urologic complication reported. Exclusion criteria were: patients younger than 18, no IVC filter placement, and no urologic complication reported. Other case series and reviews were excluded to avoid patient duplication.
EVIDENCE SYNTHESIS
Thirty-five articles were selected for full-text screening. Thirty-seven patient cases were reviewed, and the median age was 53 (range: 21-92 years old). Abdominal and or flank pain was reported in 16 (43%) patients, hematuria was seen in eight (22%) and two (5%) patients died due to acute renal failure resulting from the urologic complications of the IVC filter. Indications for IVC filter placement were recurrent pulmonary embolism (PE), contraindication to or noncompliance with anticoagulant therapy. The IVC filters were infrarenal in 29 (78.4%) patients, suprarenal in five (13.5%) patients, not reported in two patients, and misplaced into the right ovarian vein in one patient. Three or more imaging modalities were obtained in 19 patients (51%) for planning. IVC filter removal was not performed in 17 (45.9%) patients, endovascular retrieval occurred in nine (24.3%) patients, and open removal was performed in seven (18.9%) patients, and tissue interposition was performed in two (5.4%) patients. One patient did not have the management reported.
CONCLUSIONS
Urological complications caused by IVC filters although rare, are likely underreported, require extensive workup, and pose surgical challenges. Due to their complex management, filter retrieval should be planned for as soon as feasible, and plans should be made as early as during the IVC filter implant. For those that do develop complications, clinical judgement must be exercised in management, and open surgical, endovascular or even conservative management strategies can be viable options and should be discussed in a multidisciplinary setting.
Topics: Vena Cava Filters; Humans; Aged; Female; Pulmonary Embolism; Middle Aged; Adult; Aged, 80 and over; Male; Hematuria; Young Adult; Device Removal; Risk Factors; Vena Cava, Inferior; Urologic Diseases
PubMed: 38619204
DOI: 10.23736/S0392-9590.24.05041-7 -
BJU International Apr 2024To assess the re-intervention rates of new surgical benign prostatic hyperplasia (BPH) interventions, as the clinical durability of new surgical interventions for BPH is... (Review)
Review
OBJECTIVE
To assess the re-intervention rates of new surgical benign prostatic hyperplasia (BPH) interventions, as the clinical durability of new surgical interventions for BPH is not widely known.
METHODS
A critical review of new surgical BPH therapies namely 'UroLift®', 'Aquablation', 'Rezum', 'prostatic artery embolisation (PAE)' and 'temporary implantable nitinol device (iTIND)' was performed on PubMed, the Cochrane Library, and Embase databases between May 2010 and December 2022 according to the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) statement. All relevant articles were reviewed, and the risk of bias was evaluated using the Cochrane risk assessment tool and Newcastle-Ottawa Scale.
RESULTS
Of the 32 studies included, there were 10 randomised controlled trials and 22 prospective observational cohorts. A total of 2400 participants were studied with a median patient age of 66 years, a median prostate volume of 51.9 mL, and a median International Prostate Symptom Score of 22. The lowest re-intervention rate at 12 months was for Aquablation at 0.01%, followed by Rezum at 0.02%, iTIND at 0.03%, and PAE at 0.05%. Network meta-analysis (NMA) showed that the best-ranked treatment at 12 months was transurethral resection of the prostate (TURP), followed by Aquablation, iTIND, Rezum, and UroLift. Re-intervention rates with these new BPH interventions are comparable, although some interventions reported better outcomes than TURP in the shorter term.
CONCLUSIONS
While this systematic review and NMA showed that the re-intervention rate with these new surgical BPH interventions appears to be comparable to TURP in the short term, further studies are required to directly compare these various BPH procedures.
PubMed: 38600763
DOI: 10.1111/bju.16304 -
Neurosurgical Review Apr 2024Cerebral aneurysm is a life-threatening condition, which requires high precision during the neurosurgical procedures. Increasing progress of evaluating modern devices in... (Review)
Review
Cerebral aneurysm is a life-threatening condition, which requires high precision during the neurosurgical procedures. Increasing progress of evaluating modern devices in medicine have led to common usage of robotic systems in many fields, including cranial aneurysm operations. However, currently no systematic review describes up-to date knowledge of this topic. Following PRISMA guidelines, we have independently screened and extracted works from seven databases. Only studies fulfilling inclusion criteria were presented in this study. Device used, operation time, complications, aneurysm type and patient demographics were extracted from each work. We identified a total of 995 articles from databases. We have found six original works and one supplementary article eligible for this synthesis. Majority of works (4/6) have implemented CorPath GRX in cerebral aneurysm procedures. The procedures involved diverse aneurysm locations, utilizing flow diverters, stents, or coiling. One study described implementation of robot-assist on 117 patients and compared results to randomized clinical trials. One work with a small patient cohort described use of the magnetically-controlled microguidewire in the coiling procedures, without any complications. Additionally, one case-series study described use of a robotic arm for managing intraoperative aneurysm rupture. Currently, robotical devices for cerebral aneurysm treatment mainly lack jailing and haptic feedback feature. Further development of these devices will certainly be beneficial for operators and patients, allowing for more precise and remote surgeries.
Topics: Humans; Intracranial Aneurysm; Robotics; Robotic Surgical Procedures; Treatment Outcome; Embolization, Therapeutic; Endovascular Procedures; Stents; Retrospective Studies
PubMed: 38600417
DOI: 10.1007/s10143-024-02400-5 -
Cureus Feb 2024Inferior vena cava (IVC) filters have been used successfully in high-risk patients to prevent thromboembolism. The filters are widely created as retrievable devices, but... (Review)
Review
Inferior vena cava (IVC) filters have been used successfully in high-risk patients to prevent thromboembolism. The filters are widely created as retrievable devices, but complication rates progressively increase during IVC filter retrieval. This study aims to analyze IVC filter retrieval cases and associated complications during and following the procedures regarding dwell times, specific filter types, filter positioning, and advanced retrieval techniques. This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines to select and analyze relevant articles. A literature search for articles was performed on September 23, 2023, through three research databases: PubMed, ProQuest, and ScienceDirect. The keywords used to identify relevant publications were "IVC Filter retrieval AND complications" and "IVC filter removal AND complications". The articles before 2012 were excluded. Relevant articles were selected based on the inclusion and exclusion criteria. In total, 20,435 articles were found: 812 from PubMed, 15,635 from ProQuest, and 3,988 from Science Direct. Among the exclusions were 18,462 articles, which were excluded in the automatic screening process, leaving 1,973 for manual screening. The manual screening of articles was conducted based on title, abstract, article type, duplicates, and case reports, where 1,918 articles were excluded. Ultimately, 55 articles were included in this review. This study demonstrates that IVC filter retrievals have significant complication rates. Many complications have a common theme: prolonged dwell time and lost follow-up appointments. Therefore, importance should be placed on patient education and implementing strict protocols regarding the timelines of IVC filter removals.
PubMed: 38550500
DOI: 10.7759/cureus.55052 -
Neurosurgical Review Mar 2024Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch... (Meta-Analysis)
Meta-Analysis Review
Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.
Topics: Humans; Treatment Outcome; Retrospective Studies; Embolization, Therapeutic; Stents; Intracranial Aneurysm; Cerebral Angiography
PubMed: 38503965
DOI: 10.1007/s10143-024-02343-x