-
Biotechnology and Bioengineering Jun 2024The extensive use of chemical pesticides has significantly boosted agricultural food crop yields. Nevertheless, their excessive and unregulated application has resulted... (Review)
Review
The extensive use of chemical pesticides has significantly boosted agricultural food crop yields. Nevertheless, their excessive and unregulated application has resulted in food contamination and pollution in environmental, aquatic, and agricultural ecosystems. Consequently, the on-site monitoring of pesticide residues in agricultural practices is paramount to safeguard global food and conservational safety. Traditional pesticide detection methods are cumbersome and ill-suited for on-site pesticide finding. The systematic review provides an in-depth analysis of the current status and perspectives of nanobiosensors (NBS) for pesticide detection in the agricultural arena. Furthermore, the study encompasses the fundamental principles of NBS, the various transduction mechanisms employed, and their incorporation into on-site detection platforms. Conversely, the assortment of transduction mechanisms, including optical, electrochemical, and piezoelectric tactics, is deliberated in detail, emphasizing its advantages and limitations in pesticide perception. Incorporating NBS into on-site detection platforms confirms a vital feature of their pertinence. The evaluation reflects the integration of NBS into lab-on-a-chip systems, handheld devices, and wireless sensor networks, permitting real-time monitoring and data-driven decision-making in agronomic settings. The potential for robotics and automation in pesticide detection is also scrutinized, highlighting their role in improving competence and accuracy. Finally, this systematic review provides a complete understanding of the current landscape of NBS for on-site pesticide sensing. Consequently, we anticipate that this review offers valuable insights that could form the foundation for creating innovative NBS applicable in various fields such as materials science, nanoscience, food technology and environmental science.
PubMed: 38853643
DOI: 10.1002/bit.28764 -
Frontiers in Medicine 2024Ensuring high-quality healthcare for newborns is essential for improving their chances of survival within Ethiopia's healthcare system. Although various intervention...
BACKGROUND
Ensuring high-quality healthcare for newborns is essential for improving their chances of survival within Ethiopia's healthcare system. Although various intervention approaches have been implemented, neonatal mortality rates remain stable. Therefore, the present review seeks to identify initiatives for enhancing healthcare quality, their effects on neonatal wellbeing, and the factors hindering or supporting these Quality Improvement (QI) efforts' success in Ethiopia.
METHODS
We searched for original research studies up to June 23, 2023, using PubMed/Medline, WHO-Global Health Library, Cochrane, Clinical Trials.gov, and Hinari. After selecting eligible studies, we assessed their quality using a mixed-method appraisal tool. Quality of care refers to how healthcare services effectively improve desired outcomes for individuals and patient populations. It encompasses vital principles such as safety, effectiveness, timeliness, efficiency, equity, and patient-centeredness.
RESULTS
We found 3,027 publication records and included 13 studies during our search. All these interventions primarily aimed to provide safe healthcare, with a strong focus on Domain One, which deals with the evidence-based routine upkeep and handling of complications, and Domain Seven, which revolves around ensuring staff competency, emerged as a frequent target for intervention. Many interventions aimed at improving quality also concentrate on essential quality measure elements such as processes, focusing on the activities that occur during care delivery, and quality planning, involving distributing resources, such as basic medicine and equipment, and improving infrastructure. Moreover, little about the facilitators and barriers to QI interventions is investigated.
CONCLUSIONS
This review highlights the significance of introducing QI initiatives in Ethiopia, enhancing the healthcare system's capabilities, engaging the community, offering financial incentives, and leveraging mobile health technologies. Implementing QI interventions in Ethiopia poses difficulties due to resource constraints, insufficient infrastructure, and medical equipment and supplies shortages. It necessitates persistent endeavors to improve neonatal care quality, involving ongoing training, infrastructure enhancement, the establishment of standardized protocols, and continuous outcome monitoring. These efforts are crucial to achieving the optimal outcomes for newborns and their families.
PubMed: 38841585
DOI: 10.3389/fmed.2024.1293473 -
Scientific Reports Jun 2024Heart failure (HF) poses a significant challenge, often leading to frequent hospitalizations and compromised quality of life. Continuous pulmonary artery pressure (PAP)... (Meta-Analysis)
Meta-Analysis
Heart failure (HF) poses a significant challenge, often leading to frequent hospitalizations and compromised quality of life. Continuous pulmonary artery pressure (PAP) monitoring offers a surrogate for congestion status in ambulatory HF care. This meta-analysis examines the efficacy of PAP monitoring devices (CardioMEMS and Chronicle) in preventing adverse outcomes in HF patients, addressing gaps in prior randomized controlled trials (RCTs). Five RCTs (2572 participants) were systematically reviewed. PAP monitoring significantly reduced HF-related hospitalizations (RR 0.72 [95% CI 0.6-0.87], p = 0.0006) and HF events (RR 0.86 [95% CI 0.75-0.99], p = 0.03), with no impact on all-cause or cardiovascular mortality. Subgroup analyses highlighted the significance of CardioMEMS and blinded studies. Meta-regression indicated a correlation between prolonged follow-up and increased reduction in HF hospitalizations. The risk of bias was generally high, with evidence certainty ranging from low to moderate. PAP monitoring devices exhibit promise in diminishing HF hospitalizations and events, especially in CardioMEMS and blinded studies. However, their influence on mortality remains inconclusive. Further research, considering diverse patient populations and intervention strategies with extended follow-up, is crucial for elucidating the optimal role of PAP monitoring in HF management.
Topics: Humans; Heart Failure; Pulmonary Artery; Hospitalization; Randomized Controlled Trials as Topic; Quality of Life
PubMed: 38839890
DOI: 10.1038/s41598-024-63742-0 -
Balkan Medical Journal Jun 2024Type 1 diabetes is one of the most common chronic diseases in children. Wearable technology (insulin pumps and continuous glucose monitoring devices) that makes diabetes...
BACKGROUND
Type 1 diabetes is one of the most common chronic diseases in children. Wearable technology (insulin pumps and continuous glucose monitoring devices) that makes diabetes management relatively simple, in addition to education and follow-ups, enhances the quality of life and health of individuals with diabetes.
AIMS
To evaluate the impact of wearable technology on metabolic management and the quality of life in children and adolescents with type 1 diabetes.
STUDY DESIGN
Systematic review and meta-analysis.
METHODS
The Preferred Reporting System for Systematic Reviews and Meta-Analyses was used to conduct a systematic review and meta-analysis. PubMed, Web of Science, MEDLINE, Cochrane Library, EBSCO, Ulakbim and Google Scholar were searched in July 2022 and July 2023 using predetermined keywords. The methodological quality of the studies was evaluated using the Joanna Briggs Institute's Critical Appraisal Checklists for randomized controlled experimental and cross-sectional studies. The meta-analysis method was used to pool the data.
RESULTS
Eleven studies published between 2011 and 2022 were included. The total sample size of the included studies was 1,853. The meta-analysis revealed that the decrease in hemoglobin A1C (HbA1c) level in those using wearable technology was statistically significant [mean difference (MD): -0.33, Z = 2.54, = 0.01]. However, the technology had no effect on the quality of life [standardized mean difference (SMD): 0.44, Z = 1.72, = 0.09]. The subgroup analyses revealed that the decrease in the HbA1c level occurred in the cross-sectional studies (MD: -0.49, Z = 2.54, = 0.01) and the 12-19 (MD = 0.59, Z = 4.40, < 0.001) and 4-18 age groups (MD: -0.31, Z = 2.56, = 0.01). The subgroup analyses regarding the quality of life revealed that there was no difference according to the research design. However, the quality of life was higher in the wearable technology group than in the control group in the 8-12 and 4-18 age groups (SMD: 1.32, Z = 2.31, = 0.02 and SMD: 1.00, Z = 5.76, < 0.001, respectively).
CONCLUSION
Wearable technology effectively reduces the HbA1c levels in children and adolescents with type 1 diabetes in some age groups. However, it does not affect the quality of life.
PubMed: 38829237
DOI: 10.4274/balkanmedj.galenos.2024.2024-2-115 -
Alimentary Pharmacology & Therapeutics Jul 2024Acute non-variceal upper gastrointestinal bleeding (UGIB) is challenging in patients at high risk of re-bleeding in whom standard endoscopic treatment (ST) has limited... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Acute non-variceal upper gastrointestinal bleeding (UGIB) is challenging in patients at high risk of re-bleeding in whom standard endoscopic treatment (ST) has limited effectiveness. Over-the-scope clips (OTSC) have shown promise in these patients although their precise role remains uncertain.
AIMS
To confirm the role of OTSC in patients with UGIB at high risk of re-bleeding.
METHODS
We systematically searched CENTRAL, MEDLINE and Embase from January 1st, 1970 to April 24, 2024 for randomised controlled trials (RCTs) comparing OTSC and ST in acute non-variceal UGIB with high re-bleeding risk. The GRADE framework assessed evidence certainty, while trial sequential analysis (TSA) controlled random errors and evaluated conclusion validity.
RESULTS
We analysed four RCTs (319 patients); pooled risk ratio (RR) for clinical success at initial endoscopy favoured OTSC (RR = 1.30, 95% CI = 1.08-1.56, p = 0.006, I = 58%, moderate certainty of evidence). TSA showed the desired sample size was 410 and the cumulative Z curve crossing the trial sequential monitoring boundary. The pooled RR for re-bleeding within 30 days favoured OTSC (RR = 0.53, 95% CI = 0.30-0.94, p = 0.03, I = 0%, moderate certainty of evidence). There was no significant difference in 30-day mortality, or length of hospital or ICU stay.
CONCLUSIONS
Moderate certainty evidence supports OTSC as a superior initial treatment for acute non-variceal UGIB with high re-bleeding risk. Further large-scale studies are needed to confirm OTSCs' role by exploring other prognostic outcomes and assessing cost-effectiveness and potential complications.
Topics: Humans; Gastrointestinal Hemorrhage; Surgical Instruments; Recurrence; Randomized Controlled Trials as Topic; Endoscopy, Gastrointestinal; Hemostasis, Endoscopic; Treatment Outcome; Upper Gastrointestinal Tract
PubMed: 38818831
DOI: 10.1111/apt.18093 -
JAMA Jun 2024Concerns have arisen that renin-angiotensin system (RAS) blockers are less effective in Black patients than non-Black patients with heart failure and reduced ejection... (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Concerns have arisen that renin-angiotensin system (RAS) blockers are less effective in Black patients than non-Black patients with heart failure and reduced ejection fraction (HFrEF).
OBJECTIVE
To determine whether the effects of RAS blockers on cardiovascular outcomes differ between Black patients and non-Black patients with HFrEF.
DATA SOURCES
MEDLINE and Embase databases through December 31, 2023.
STUDY SELECTION
Randomized trials investigating the effect of RAS blockers on cardiovascular outcomes in adults with HFrEF that enrolled Black and non-Black patients.
DATA EXTRACTION AND SYNTHESIS
Individual-participant data were extracted following Preferred Reporting Items for Systematic Reviews and Meta-analyses Independent Personal Data (PRISMA-IPD) reporting guidelines. Effects were estimated using a mixed-effects model using a 1-stage approach.
MAIN OUTCOME AND MEASURE
The primary outcome was first hospitalization for HF or cardiovascular death.
RESULTS
The primary analysis, based on the 3 placebo-controlled RAS inhibitor monotherapy trials, included 8825 patients (9.9% Black). Rates of death and hospitalization for HF were substantially higher in Black than non-Black patients. The hazard ratio (HR) for RAS blockade vs placebo for the primary composite was 0.84 (95% CI, 0.69-1.03) in Black patients and 0.73 (95% CI, 0.67-0.79) in non-Black patients (P for interaction = .14). The HR for first HF hospitalization was 0.89 (95% CI, 0.70-1.13) in Black patients and 0.62 (95% CI, 0.56-0.69) in non-Black patients (P for interaction = .006). Conversely, the corresponding HRs for cardiovascular death were 0.83 (95% CI, 0.65-1.07) and 0.84 (95% CI, 0.77-0.93), respectively (P for interaction = .99). For total hospitalizations for HF and cardiovascular deaths, the corresponding rate ratios were 0.82 (95% CI, 0.66-1.02) and 0.72 (95% CI, 0.66-0.80), respectively (P for interaction = .27). The supportive analyses including the 2 trials adding an angiotensin receptor blocker to background angiotensin-converting enzyme inhibitor treatment (n = 16 383) gave consistent findings.
CONCLUSIONS AND RELEVANCE
The mortality benefit from RAS blockade was similar in Black and non-Black patients. Despite the smaller relative risk reduction in hospitalization for HF with RAS blockade in Black patients, the absolute benefit in Black patients was comparable with non-Black patients because of the greater incidence of this outcome in Black patients.
Topics: Heart Failure; Humans; Randomized Controlled Trials as Topic; Angiotensin Receptor Antagonists; Angiotensin-Converting Enzyme Inhibitors; Hospitalization; Renin-Angiotensin System; Stroke Volume; Black or African American
PubMed: 38809561
DOI: 10.1001/jama.2024.6774 -
World Journal For Pediatric &... May 2024Outpatient monitoring of infants with congenital heart disease has been shown to significantly reduce rates of mortality in the single ventricle population. Despite the... (Review)
Review
Outpatient monitoring of infants with congenital heart disease has been shown to significantly reduce rates of mortality in the single ventricle population. Despite the accelerating development of miniaturized biosensors and electronics, and a growing market demand for at-home monitoring devices, the application of these technologies to infants and children is significantly delayed compared with the development of devices for adults. This article aims to review the current landscape of available monitoring technologies and devices for pediatric patients to describe the gap between technologies and clinical needs with the goal of progressing development of clinically and scientifically validated pediatric monitoring devices.
PubMed: 38807505
DOI: 10.1177/21501351241247500 -
JMIR MHealth and UHealth May 2024Unaddressed early-stage mental health issues, including stress, anxiety, and mild depression, can become a burden for individuals in the long term. Digital phenotyping... (Review)
Review
BACKGROUND
Unaddressed early-stage mental health issues, including stress, anxiety, and mild depression, can become a burden for individuals in the long term. Digital phenotyping involves capturing continuous behavioral data via digital smartphone devices to monitor human behavior and can potentially identify milder symptoms before they become serious.
OBJECTIVE
This systematic literature review aimed to answer the following questions: (1) what is the evidence of the effectiveness of digital phenotyping using smartphones in identifying behavioral patterns related to stress, anxiety, and mild depression? and (2) in particular, which smartphone sensors are found to be effective, and what are the associated challenges?
METHODS
We used the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) process to identify 36 papers (reporting on 40 studies) to assess the key smartphone sensors related to stress, anxiety, and mild depression. We excluded studies conducted with nonadult participants (eg, teenagers and children) and clinical populations, as well as personality measurement and phobia studies. As we focused on the effectiveness of digital phenotyping using smartphones, results related to wearable devices were excluded.
RESULTS
We categorized the studies into 3 major groups based on the recruited participants: studies with students enrolled in universities, studies with adults who were unaffiliated to any particular organization, and studies with employees employed in an organization. The study length varied from 10 days to 3 years. A range of passive sensors were used in the studies, including GPS, Bluetooth, accelerometer, microphone, illuminance, gyroscope, and Wi-Fi. These were used to assess locations visited; mobility; speech patterns; phone use, such as screen checking; time spent in bed; physical activity; sleep; and aspects of social interactions, such as the number of interactions and response time. Of the 40 included studies, 31 (78%) used machine learning models for prediction; most others (n=8, 20%) used descriptive statistics. Students and adults who experienced stress, anxiety, or depression visited fewer locations, were more sedentary, had irregular sleep, and accrued increased phone use. In contrast to students and adults, less mobility was seen as positive for employees because less mobility in workplaces was associated with higher performance. Overall, travel, physical activity, sleep, social interaction, and phone use were related to stress, anxiety, and mild depression.
CONCLUSIONS
This study focused on understanding whether smartphone sensors can be effectively used to detect behavioral patterns associated with stress, anxiety, and mild depression in nonclinical participants. The reviewed studies provided evidence that smartphone sensors are effective in identifying behavioral patterns associated with stress, anxiety, and mild depression.
Topics: Humans; Depression; Stress, Psychological; Anxiety; Phenotype; Smartphone
PubMed: 38780995
DOI: 10.2196/40689 -
The Cochrane Database of Systematic... May 2024Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail,... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection.
OBJECTIVES
To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people.
SEARCH METHODS
We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people.
DATA COLLECTION AND ANALYSIS
Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence).
AUTHORS' CONCLUSIONS
There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.
Topics: Humans; Randomized Controlled Trials as Topic; Catheterization, Peripheral; Bandages; Catheter-Related Infections; Polyurethanes; Bias; Equipment Failure
PubMed: 38780138
DOI: 10.1002/14651858.CD013023.pub2 -
Critical Care Science 2024To provide insights into the potential benefits of goal-directed therapy guided by FloTrac in reducing postoperative complications and improving outcomes. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To provide insights into the potential benefits of goal-directed therapy guided by FloTrac in reducing postoperative complications and improving outcomes.
METHODS
We performed a systematic review and meta-analysis of randomized controlled trials to evaluate goal-directed therapy guided by FloTrac in major surgery, comparing goal-directed therapy with usual care or invasive monitoring in cardiac and noncardiac surgery subgroups. The quality of the articles and evidence were evaluated with a risk of bias tool and GRADE.
RESULTS
We included 29 randomized controlled trials with 3,468 patients. Goal-directed therapy significantly reduced the duration of hospital stay (mean difference -1.43 days; 95%CI 2.07 to -0.79; I2 81%), intensive care unit stay (mean difference -0.77 days; 95%CI -1.18 to -0.36; I2 93%), and mechanical ventilation (mean difference -2.48 hours, 95%CI -4.10 to -0.86, I2 63%). There was no statistically significant difference in mortality, myocardial infarction, acute kidney injury or hypotension, but goal-directed therapy significantly reduced the risk of heart failure or pulmonary edema (RR 0.46; 95%CI 0.23 - 0.92; I2 0%).
CONCLUSION
Goal-directed therapy guided by the FloTrac sensor improved clinical outcomes and shortened the length of stay in the hospital and intensive care unit in patients undergoing major surgery. Further research can validate these results using specific protocols and better understand the potential benefits of FloTrac beyond these outcomes.
Topics: Humans; Length of Stay; Postoperative Complications; Randomized Controlled Trials as Topic; Intensive Care Units; Respiration, Artificial; Early Goal-Directed Therapy; Monitoring, Physiologic
PubMed: 38775544
DOI: 10.62675/2965-2774.20240196-en