-
JACC. Clinical Electrophysiology Aug 2023Commotio cordis is an increasingly recognized cause of sudden cardiac death. Although commonly linked with athletes, many events occur in non-sport-related settings.
BACKGROUND
Commotio cordis is an increasingly recognized cause of sudden cardiac death. Although commonly linked with athletes, many events occur in non-sport-related settings.
OBJECTIVES
The goal of this study was to characterize and compare non-sport-related vs sport-related commotio cordis.
METHODS
PubMed and Embase were searched for all cases of commotio cordis from inception to January 5, 2022.
RESULTS
Of 334 commotio cordis cases identified, 121 (36%) occurred in non-sport-related contexts, which included assault (76%), motor vehicle accidents (7%), and daily activities (16%). Projectiles were implicated significantly less in non-sport-related events (5% vs 94%, respectively; P < 0.001). Nonprojectile etiologies in non-sport-related events mostly consisted of impacts with body parts (79%). Both categories affected similar younger aged demographic (P = 0.10). The proportion of female victims was significantly higher in non-sport-related events (13% vs 2%, respectively; P = 0.025). Mortality was significantly higher in non-sport-related events (88% vs 66%, respectively; P < 0.001). In non-sport-related events, rates of cardiopulmonary resuscitation (27% vs 97%, respectively; P < 0.001) and defibrillation (17% vs 81%, respectively; P < 0.001) were both lower and resuscitation was more commonly delayed beyond 3 min (80% vs 5%, respectively; P < 0.001).
CONCLUSIONS
Commotio cordis occurs across a spectrum of non-sport-related settings including assault, motor vehicle accidents, and daily activities. Both categories affected a younger and male-predominant demographic. Mortality is higher in non-sport-related commotio cordis, likely owing to lower rates of cardiopulmonary resuscitation, defibrillation, automated external defibrillator availability, and extended time to resuscitation. Increased awareness of non-sport-related commotio cordis is essential to develop a means of prevention and mortality reduction, with earlier recognition and prompt resuscitation measures.
Topics: Humans; Male; Female; Aged; Commotio Cordis; Cardiopulmonary Resuscitation; Death, Sudden, Cardiac; Defibrillators
PubMed: 37558288
DOI: 10.1016/j.jacep.2023.01.010 -
World Journal of Emergency Surgery :... May 2023The diagnosis of cardiac contusion, caused by blunt chest trauma, remains a challenge due to the non-specific symptoms it causes and the lack of ideal tests to diagnose... (Meta-Analysis)
Meta-Analysis Review
INTRODUCTION
The diagnosis of cardiac contusion, caused by blunt chest trauma, remains a challenge due to the non-specific symptoms it causes and the lack of ideal tests to diagnose myocardial damage. A cardiac contusion can be life-threatening if not diagnosed and treated promptly. Several diagnostic tests have been used to evaluate the risk of cardiac complications, but the challenge of identifying patients with contusions nevertheless remains.
AIM OF THE STUDY
To evaluate the accuracy of diagnostic tests for detecting blunt cardiac injury (BCI) and its complications, in patients with severe chest injuries, who are assessed in an emergency department or by any front-line emergency physician.
METHODS
A targeted search strategy was performed using Ovid MEDLINE and Embase databases from 1993 up to October 2022. Data on at least one of the following diagnostic tests: electrocardiogram (ECG), serum creatinine phosphokinase-MB level (CPK-MB), echocardiography (Echo), Cardiac troponin I (cTnI) or Cardiac troponin T (cTnT). Diagnostic tests for cardiac contusion were evaluated for their accuracy in meta-analysis. Heterogeneity was assessed using the I and the QUADAS-2 tool was used to assess bias of the studies.
RESULTS
This systematic review yielded 51 studies (n = 5,359). The weighted mean incidence of myocardial injuries after sustaining a blunt force trauma stood at 18.3% of cases. Overall weighted mean mortality among patients with blunt cardiac injury was 7.6% (1.4-36.4%). Initial ECG, cTnI, cTnT and transthoracic echocardiography TTE all showed high specificity (> 80%), but lower sensitivity (< 70%). TEE had a specificity of 72.1% (range 35.8-98.2%) and sensitivity of 86.7% (range 40-99.2%) in diagnosing cardiac contusion. CK-MB had the lowest diagnostic odds ratio of 3.598 (95% CI: 1.832-7.068). Normal ECG accompanied by normal cTnI showed a high sensitivity of 85% in ruling out cardiac injuries.
CONCLUSION
Emergency physicians face great challenges in diagnosing cardiac injuries in patients following blunt trauma. In the majority of cases, joint use of ECG and cTnI was a pragmatic and cost-effective approach to rule out cardiac injuries. In addition, TEE may be highly accurate in identifying cardiac injuries in suspected cases.
Topics: Humans; Thoracic Injuries; Wounds, Nonpenetrating; Heart Injuries; Myocardial Contusions; Troponin I; Troponin T; Diagnostic Tests, Routine
PubMed: 37245048
DOI: 10.1186/s13017-023-00504-9 -
European Journal of Trauma and... Aug 2021Myocardial contusion can be a life-threatening condition in patients who sustained blunt thoracic trauma. The diagnostic approach remains a subject of debate. The aim of... (Meta-Analysis)
Meta-Analysis
PURPOSE
Myocardial contusion can be a life-threatening condition in patients who sustained blunt thoracic trauma. The diagnostic approach remains a subject of debate. The aim of this study was to determine the sensitivity and specificity of echocardiography, electrocardiography, troponins T and I (TnT and TnI), and creatine kinase muscle/brain (CK-MB) for identifying patients with a myocardial contusion following blunt thoracic trauma.
METHODS
Sensitivity and specificity were first determined in a 10-year retrospective cohort study and second by a systematic literature review with meta-analysis.
RESULTS
Of the 117 patients in the retrospective study, 44 (38%) were considered positive for myocardial contusion. Chest X-ray, chest CT scan, electrocardiograph, and echocardiography had poor sensitivity (< 15%) but good specificity (≥ 90%). Sensitivity to cardiac biomarkers measured at presentation ranged from 59% for TnT to 77% for hs-TnT, specificity ranged from 63% for CK-MB to 100% for TnT. The systematic literature review yielded 28 studies, with 14.5% out of 7242 patients reported as positive for myocardial contusion. The pooled sensitivity of electrocardiography, troponin I, and CK-MB was between 62 and 71%, versus only 45% for echocardiography and 38% for troponin T. The pooled specificity ranged from 63% for CK-MB to 85% for troponin T and 88% for echocardiography.
CONCLUSION
The best diagnostic approach for myocardial contusion is a combination of electrocardiography and measurement of cardiac biomarkers. If abnormalities are found, telemonitoring is necessary for the early detection of life-threatening arrhythmias. Chest X-ray and CT scan may show other thoracic injuries but provide no information on myocardial contusion.
Topics: Biomarkers; Electrocardiography; Humans; Myocardial Contusions; Retrospective Studies; Sensitivity and Specificity; Thoracic Injuries; Troponin T
PubMed: 31982920
DOI: 10.1007/s00068-020-01305-4 -
Heart Rhythm Oct 2017The underlying mechanisms and temporal course of complete heart block (CHB) after blunt cardiac injuries (BCIs) are poorly understood, and a systematic analysis of... (Review)
Review
The underlying mechanisms and temporal course of complete heart block (CHB) after blunt cardiac injuries (BCIs) are poorly understood, and a systematic analysis of available data is lacking. In this systematic review, PubMed was searched for publications of reported cases of CHB-BCI analyzing clinical findings, electrocardiographic features, temporal course, and outcomes. Case reports on CHB-BCI were available for 50 patients, mainly secondary to traffic or sport accidents. A fatal outcome occurred in 10 of 50 (20%) of patients, while a structural damage of the atrioventricular (AV) conductive system was evident in 4 of 8 (50%) of necropsy studies. Clinical manifestation of CHB-BCI occurred within 72 hours of injury in 38 of 47 (∼80%) of patients, and 1:1 AV conduction was restored within 7-10 days in about half of early survivors. Permanent pacemaker implantation was indicated in 22 of 42 (∼50%) of early survivors because of recurrent or permanent CHB. Cardiac troponins, when analyzed, were elevated in 12 of 13 (∼90%) of patients, and electrocardiographic features of aberrancy were present in 29 of 40 (>70%) of patients. In conclusion, CHB secondary to BCI is associated with 20% mortality mainly occurring in the early posttraumatic period and most of the deaths are due to or triggered by this malignant arrhythmia. Recurrent or permanent CHB requiring pacemaker implantation occurs in ∼50% of survivors. A structural damage of the AV conductive system can be found in 50% of necropsy studies.
Topics: Atrioventricular Block; Electrocardiography; Heart Conduction System; Humans; Myocardial Contusions
PubMed: 28583850
DOI: 10.1016/j.hrthm.2017.05.040 -
The Physician and Sportsmedicine Apr 2010To determine whether chest protectors and/or safety baseballs reduce the incidence of commotio cordis during sport through a review of the best available evidence. (Review)
Review
OBJECTIVE
To determine whether chest protectors and/or safety baseballs reduce the incidence of commotio cordis during sport through a review of the best available evidence.
DATA SOURCES
PubMed, Ovid Medline, and Embase databases from 1950 to 2009. We selected articles according to "death, sudden, cardiac," "commotio cordis," "sports equipment," and "protective devices." We identified 17 articles in the systematic literature search. Of these, 7 articles met inclusion criteria. Three independent reviewers reviewed the articles. The study results and generated conclusions were extracted and agreed on.
RESULTS
The softest safety baseball shows statistically significant reductions in the incidence of ventricular fibrillation (VF) at all velocities compared with standard baseballs in the 3 studies that evaluated their use. Different degrees of softness did not show statistically significant reductions in VF. In the 3 studies that evaluated the use of chest protectors against controls, there was an increase in protection against fatal arrhythmias; however, this was only statistically significant for 1 chest protector.
CONCLUSIONS
This systematic review shows strong supportive evidence toward a decreased rate of commotio cordis with safety baseballs when compared with standard balls. Based on the results of our systematic review, the rate of induction of VF was at its lowest when chest protection was used.
Topics: Animals; Baseball; Commotio Cordis; Disease Models, Animal; Humans; Manikins; Protective Clothing; Sports Equipment; Sus scrofa
PubMed: 20424405
DOI: 10.3810/psm.2010.04.1765