Eye (London, England) Apr 2023The XEN45 Gel Stent is a subconjunctival filtering device that has demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported complications... (Meta-Analysis)
Meta-Analysis
BACKGROUND
The XEN45 Gel Stent is a subconjunctival filtering device that has demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported complications and interventions after XEN45 implantation in the treatment of open angle glaucoma (OAG).
METHODS
Pilot, cohort, observational studies, and randomised controlled trials that included at least ten patients undergoing ab interno or externo XEN45 surgery, with or without phacoemulsification were deemed eligible for inclusion. A meta-analysis of proportions with random-effect models was performed using the meta routine in R version 3.2.1. Outcomes included the rate of complications and post-operative interventions.
RESULTS
One hundred and fifty-two studies were identified on initial literature search and 33 were included in final analysis. Numerical hypotony was the most common post-operative complication, involving 20% of patients (95% CI: 10-31%). Post-operative gross hyphema occurred in 14% (95% CI: 7-22%) and transient intra-ocular pressure (IOP) spikes (>30 mmHg) in 13% (95% CI: 4-27%). Stent exposure occurred in 1% (95% CI: 0-2%). Stent migration occurred in 1% (95% CI: 0-3%). XEN45 revision and/or a second XEN45 implantation was performed in 5% of patients (95% CI: 3-7%). Stent relocation was performed in 3% (95% CI: 1-7%). A second glaucoma procedure was performed in 11% (95% CI: 8-15%). 26% underwent one (95% CI: 17-36%), 13% underwent two (95% CI: 5-24%) while 4% underwent three (95% CI: 2-6%) bleb needling procedures. 35% of patients (95% CI: 29-40%) required at least one needling. The average rate of needling per patient was 0.38 (95% CI: 0.20-0.59). However, there is a lack of high-quality data, with 8 of the 33 studies assessed to have a moderate to high risk of bias.
CONCLUSIONS
While literature suggests that XEN45 Gel Stent implantation is safe in the treatment of OAG, the overall current level of evidence is low and further studies are needed. More than a third of patients require at least one post-operative bleb needling procedure.
Topics: Humans; Glaucoma, Open-Angle; Blister; Treatment Outcome; Glaucoma; Intraocular Pressure; Glaucoma Drainage Implants; Stents; Retrospective Studies
PubMed: 35347294
DOI: 10.1038/s41433-022-02022-5 -
Ophthalmology Aug 2022Corneal endothelial cell density (ECD) loss after glaucoma surgery with or without cataract surgery. (Meta-Analysis)
Meta-Analysis Review
TOPIC
Corneal endothelial cell density (ECD) loss after glaucoma surgery with or without cataract surgery.
CLINICAL RELEVANCE
Corneal ECD loss may occur as the result of intraoperative surgical trauma in glaucoma surgery or postoperatively with chronic endothelial cell trauma or irritation.
METHODS
Glaucoma filtration surgery or microinvasive glaucoma surgery (MIGS) in participants with ocular hypertension, primary and secondary open-angle glaucoma, normal-tension glaucoma, and angle-closure glaucoma were included. Electronic databases searched in December 2021 included MEDLINE, Embase, Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, the International Prospective Register of Systematic Reviews, Food and Drug Administration (FDA) Premarket Approval, and FDA 510(k).
RESULTS
A total of 39 studies were included in quantitative synthesis. Twelve months after suprachoroidal MIGS, mean ECD loss was 282 cells/mm (95% confidence interval [CI], 220-345; P < 0.00001; chi-square = 0.06; I = 0%; 2 studies; very low certainty). Mean ECD loss after Schlemm's canal implantable devices was 338 cells/mm (95% CI, 185-491; P < 0.0001; chi-square = 0.08; I = 0%; 2 studies; low certainty) at 12 months. Mean ECD loss was 64 cells/mm (95% CI, 21-107; P = 0.004; chi-square = 4.55; I = 0%; 6 studies; low certainty) after Schlemm's canal procedures (without implantable devices) at 12 months. At 12 months, the mean ECD loss after trabeculectomy was 33 cells/mm (95% CI, -38 to 105, P = 0.36, chi-square = 1.17; I = 0%; moderate certainty). At 12 months, mean ECD loss was 121 cells/mm (95% CI, 53-189; P = 0.0005; chi-square = 3.00; I = 0%; 5 studies; low certainty) after Express (Alcon) implantation. When compared with the control fellow eye, aqueous shunt surgery reduced ECD by 5.75% (95% CI, -0.93 to 12.43; P = 0.09, chi-square = 1.32; I = 0%; low certainty) and 8.11% ECD loss (95% CI, 0.06-16.16 P = 0.05; chi-square = 1.93; I = 48%) at 12 and 24 months, respectively.
CONCLUSIONS
Overall, there is low certainty evidence to suggest that glaucoma surgery involving long-term implants has a greater extent of ECD loss than glaucoma filtration surgeries without the use of implants. The results of this review support follow-up beyond 36 months to assess ECD loss and corneal decompensation after implantation of glaucoma drainage implants.
Topics: Cataract; Corneal Endothelial Cell Loss; Endothelial Cells; Glaucoma; Glaucoma Drainage Implants; Glaucoma, Open-Angle; Humans
PubMed: 35331751
DOI: 10.1016/j.ophtha.2022.03.015 -
Ophthalmic Research 2022Pathophysiological overlaps exist between diabetes and primary open-angle glaucoma (POAG) and presence of diabetes increases the risk of POAG. Considering that diabetic... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Pathophysiological overlaps exist between diabetes and primary open-angle glaucoma (POAG) and presence of diabetes increases the risk of POAG. Considering that diabetic retinopathy (DR) is an ocular complication of diabetes, one could speculate that DR as a severity measure may associate with or even predict POAG. Given that POAG is asymptomatic in early stages, an association to DR may prove clinically important and facilitate an earlier diagnosis of POAG.
OBJECTIVES
The aim of the study was to investigate if DR is associated with and predictive of POAG.
METHOD
We systematically searched 11 literature databases on May 12, 2021. We screened a total of 1,535 records and found six studies eligible for qualitative and quantitative analysis. Two independent authors reviewed the studies, extracted data, and evaluated risk of bias within individual studies. Studies were reviewed qualitatively, and meta-analyses were made based on the odds ratios (ORs) with 95% confidence intervals (CI) of the association between DR and POAG using the random-effects model. Subgroup analyses were made on the association between subtypes of DR and POAG.
RESULTS
Six studies (two longitudinal and four cross-sectional) were eligible for review with a total of 255,614 patients with diabetes, of which 20,483 patients had any degree of DR and 5,258 had POAG. All studies were based on patients with type 2 diabetes except one with both type 1 and type 2 patients. Any DR was not associated with POAG (OR 1.17; 95% CI: 0.58-2.35; p = 0.65). Further stratification revealed that neither cross-sectional (OR 1.00; 95% CI: 0.56-1.81, p = 0.99) nor longitudinal studies (OR 1.47; 95% CI: 0.57-3.78, p = 0.43) demonstrated an association between DR and POAG.
CONCLUSIONS
We did not find convincing evidence of an associations between DR and prevalent or incident POAG.
Topics: Cross-Sectional Studies; Diabetes Mellitus, Type 2; Diabetic Retinopathy; Glaucoma, Open-Angle; Humans; Polymorphism, Genetic
PubMed: 35313300
DOI: 10.1159/000523940 -
Frontiers in Medicine 2022XEN gel stents are used for the treatment of open-angle glaucoma (OAG), including primary and secondary glaucoma that are uncontrolled by previous medical therapy and...
PURPOSE
XEN gel stents are used for the treatment of open-angle glaucoma (OAG), including primary and secondary glaucoma that are uncontrolled by previous medical therapy and cases with previous failed surgery. Our aim was to systematically review of the clinical data of currently published ab-interno XEN gel stents with an emphasis on intraocular pressure (IOP), antiglaucoma medication outcomes, and safety profiles.
METHODS
We analyzed all of the publications (MEDLINE, EMBASE, Cochrane Library) on the ab-interno XEN gel stent to evaluate the reduction in IOP and antiglaucoma medications following the procedure. The primary outcomes measured for the meta-analysis were reduction in IOP and anti-glaucoma medications. The secondary outcome were adverse events. For each study, we used a random effects analysis model to calculate the mean difference and 95% confidence intervals for the continuous results (reduction in IOP and antiglaucoma medications) using the inverse variance statistical method.
RESULTS
Five hundred twenty-seven articles were checked and 56 studies were found to be relevant with a total of 4,410 eyes. There was a significant reduction in IOP as well as in the number of medications required in patients treated with ab-interno XEN implant either alone or combined with cataract surgery. This new treatment for various types of glaucoma reduced the IOP by 35% to a final average close to 15 mmHg. This reduction was accompanied by a decrease in the number of antiglaucoma medications in all the studies, approximately 2 classes of medication at the price of more needlings. The overall complete success rate was 21.0-70.8% after 2 years using strict criteria originally designed to record success rate in filtration surgery. The incidence of complications vision-threatening was low at <1%.
CONCLUSIONS
XEN gel stent was effective and safe for primary and secondary OAG. Further studies should be performed to investigate the impact of ethnicity on the success and failure rate after XEN implantation.
PubMed: 35186992
DOI: 10.3389/fmed.2022.804847 -
Repeat Selective Laser Trabeculoplasty for Glaucoma Patients: A Systematic Review and Meta-analysis.Journal of Current Glaucoma Practice 2021To evaluate repeat selective laser trabeculoplasty (SLT) for treating primary open-angle glaucoma (POAG).
AIM AND OBJECTIVE
To evaluate repeat selective laser trabeculoplasty (SLT) for treating primary open-angle glaucoma (POAG).
MATERIALS AND METHODS
PubMed, CINAHL, and EMBASE were systematically searched along with grey literature. All English articles that measured intraocular pressure (IOP) before and after repeat SLT on adult patients with POAG were included. Studies were not filtered by location or publication date. Covidence was used to screen imported articles. Risk of bias assessment and data extraction was performed after screening. Meta-analysis was performed using STATA 16.0. Fixed-effect or random-effects models were developed depending on the presence of heterogeneity.
RESULTS
Database and grey literature search identified 512 unique studies. After duplicate removal and screening, 12 articles were included and data from included studies were synthesized. Nine articles were included in the meta-analysis. Three studies were prospective observational studies, and nine studies were retrospective chart reviews. Due to the presence of heterogeneity, a random-effects model has been utilized that suggested significant IOP reduction (IOPR) by repeat SLT at 24 months follow-up.
CONCLUSION
Based on our results, repeat SLT could be an effective procedure in reducing IOP for patients with glaucoma for up to 24 months. Efficacy of third, fourth, or further SLT remains to be verified. More data from long-term, high-quality randomized-controlled trials (RCTs) are required to make conclusions.
CLINICAL SIGNIFICANCE
Repeat SLT may be an effective treatment for lowering IOP with minimal complications or safety issues. This may allow the use of SLT as a primary treatment for POGA, allowing the discontinuation of medications or eye drops and lead to additional benefits.
HOW TO CITE THIS ARTICLE
Jang HJ, Yu B, Hodge W, Repeat Selective Laser Trabeculoplasty for Glaucoma Patients: A Systematic Review and Meta-analysis. J Curr Glaucoma Pract 2021;15(3):117-124.
PubMed: 35173393
DOI: 10.5005/jp-journals-10078-1302 -
BMC Ophthalmology Feb 2022β-Zone parapapillary atrophy (β-PPA) is a common sign in patients with open-angle glaucoma (OAG). Some studies have suggested that β-PPA can aid in the diagnosis of... (Meta-Analysis)
Meta-Analysis
BACKGROUND
β-Zone parapapillary atrophy (β-PPA) is a common sign in patients with open-angle glaucoma (OAG). Some studies have suggested that β-PPA can aid in the diagnosis of OAG. We performed a systematic review and meta-analysis of the prevalence and diagnostic ability of β-PPA in OAG.
METHODS
We performed a literature search in PubMed, Web of Science, Embase and Google Scholar from inception to 1st November, 2021. Both hospital-based and population-based studies that reported details of β-PPA in OAG were included.
RESULTS
We screened 1404 articles from these databases and ultimately included 24 articles in our meta-analysis. The prevalence of β-PPA in OAG was 0.73 (95% CI 0.67 to 0.78). The results of subgroup analysis by country revealed prevalence rates of 0.83 (95% CI 0.78 to 0.88) in Japan, 0.85 (95% CI 0.64 to 0.97) in Korea, 0.64 (95% CI 0.55 to 0.73) in the USA, 0.61 (95% CI 0.58 to 0.63) in Germany and 0.57 (95% CI 0.39 to 0.74) in China. Fundus photography, Heidelberg retina tomography (HRT), Heidelberg retina angiography (HRA) + indocyanine green angiography (ICGA), Spectral domain optical coherence tomography (SD-OCT)and Swept source optical coherence tomography(SS-OCT) values were 0.65 (95% CI 0.58 to 0.71), 0.70 (95% CI 0.50 to 0.86), 0.78 (95% CI 0.61 to 0.91), 0.77 (95% CI 0.65 to 0.88) and 0.99(95% CI 0.87 to 1.00) respectively. The sensitivity and specificity of β-PPA as a diagnostic marker were 0.78 (95% CI 0.68 to 0.85) and 0.63 (95% CI 0.51 to 0.73), respectively.
CONCLUSIONS
β-PPA is a potential diagnostic marker for OAG. However, a more detailed understanding of β-PPA characteristics is needed to improve the ability to predict OAG.
Topics: Atrophy; Glaucoma, Open-Angle; Humans; Intraocular Pressure; Optic Atrophy; Optic Disk; Prevalence; Tomography, Optical Coherence
PubMed: 35151269
DOI: 10.1186/s12886-022-02282-5 -
European Journal of Ophthalmology Jul 2022It had been reported that mutations in gene probably play an important role in the pathogenesis of primary open angle glaucoma (POAG) but the existing genetic... (Meta-Analysis)
Meta-Analysis
PURPOSE
It had been reported that mutations in gene probably play an important role in the pathogenesis of primary open angle glaucoma (POAG) but the existing genetic association studies show contradictory results. Thus, the objective of our study was to perform a systematic review and meta-analysis to characterize more precisely the potential association between given polymorphisms in gene and the risk of suffering POAG.
METHODS
A systematic review of studies that related the risk of carrying gene polymorphisms with POAG development was conducted. We selected 19 case-control studies including 3855 POAG patients and 4125 control subjects in our meta-analyses. A random effects model was used. Sensitivity analysis and assessment of bias were also included.
RESULTS
The prevalence of gene polymorphisms were significantly more frequent among POAG patients compared to all controls (OR = 2.91, 95% CI = 1.37 - 6.21; P = 0.006). Moreover, their prevalence was significantly higher in juvenile-onset patients than in adult-onset ones (OR = 2.27, 95% CI = 1.20-4.28; P = 0.001).
CONCLUSION
The results of this meta-analysis uphold that being a carrier of polymorphic genetic variants in gene would increase the risk of POAG, especially the juvenile onset.
Topics: Adult; Case-Control Studies; Cytochrome P-450 CYP1B1; Genetic Association Studies; Glaucoma, Open-Angle; Humans; Mutation; Polymorphism, Single Nucleotide
PubMed: 35138193
DOI: 10.1177/11206721221077621 -
Ophthalmology Jun 2022This systematic review and meta-analysis summarizes the existing evidence for the association of alcohol use with intraocular pressure (IOP) and open-angle glaucoma... (Meta-Analysis)
Meta-Analysis Review
TOPIC
This systematic review and meta-analysis summarizes the existing evidence for the association of alcohol use with intraocular pressure (IOP) and open-angle glaucoma (OAG).
CLINICAL RELEVANCE
Understanding and quantifying these associations may aid clinical guidelines or treatment strategies and shed light on disease pathogenesis. The role of alcohol, a modifiable factor, in determining IOP and OAG risk also may be of interest from an individual or public health perspective.
METHODS
The study protocol was preregistered in the Open Science Framework Registries (https://osf.io/z7yeg). Eligible articles (as of May 14, 2021) from 3 databases (PubMed, Embase, Scopus) were independently screened and quality assessed by 2 reviewers. All case-control, cross-sectional, and cohort studies reporting a quantitative effect estimate and 95% confidence interval (CI) for the association between alcohol use and either IOP or OAG were included. The evidence for the associations with both IOP and OAG was qualitatively summarized. Effect estimates for the association with OAG were pooled using random effects meta-analysis. Studies not meeting formal inclusion criteria for systematic review, but with pertinent results, were also appraised and discussed. Certainty of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework.
RESULTS
Thirty-four studies were included in the systematic review. Evidence from 10 studies reporting an association with IOP suggests that habitual alcohol use is associated with higher IOP and prevalence of ocular hypertension (IOP > 21 mmHg), although absolute effect sizes were small. Eleven of 26 studies, comprising 173 058 participants, that tested for an association with OAG met inclusion criteria for meta-analysis. Pooled effect estimates indicated a positive association between any use of alcohol and OAG (1.18; 95% confidence interval [CI], 1.02-1.36; P = 0.03; I = 40.5%), with similar estimates for both prevalent and incident OAG. The overall GRADE certainty of evidence was very low.
CONCLUSIONS
Although this meta-analysis suggests a harmful association between alcohol use and OAG, our results should be interpreted cautiously given the weakness and heterogeneity of the underlying evidence base, the small absolute effect size, and the borderline statistical significance. Nonetheless, these findings may be clinically relevant, and future research should focus on improving the quality of evidence.
Topics: Cross-Sectional Studies; Ethanol; Glaucoma, Open-Angle; Humans; Intraocular Pressure; Ocular Hypertension; Tonometry, Ocular
PubMed: 35101531
DOI: 10.1016/j.ophtha.2022.01.023 -
Survey of Ophthalmology 2022The XEN45 Gel Stent (Allergan Inc., Irvine, CA) allows the drainage of aqueous into the sub-conjunctival space, through a minimally-invasive approach. This systematic... (Meta-Analysis)
Meta-Analysis Review
The XEN45 Gel Stent (Allergan Inc., Irvine, CA) allows the drainage of aqueous into the sub-conjunctival space, through a minimally-invasive approach. This systematic review and meta-analysis evaluates its intraocular pressure (IOP)-lowering efficacy and complications in the treatment of open-angle glaucoma. Fourteen studies comprising 963 eyes were included. IOP decreased significantly (P < 0.001) across all timepoints (1 day, 1 week, 1, 3, 6, 12, 18, and 24 months) with a mean decrease of 7.44 mm Hg (95%CI:4.91-9.97) at 24 months. IOP-lowering medications decreased significantly (P < 0.001) across all timepoints (1 week, 1, 3, 6, 12, 18, 24 months) with a mean reduction of 1.67 medications (95%CI:1.28-2.06) at 24 months. Numerical hypotony occurred in 39% (95%CI:14%-67%) and stent exposure in 1% (95%CI:0%-2%) of eyes. 38% (95%CI:30%-46%) of eyes required at least one postoperative needling, with an average of 0.6 (95%CI:0.37-0.81) needlings per eye. Standalone XEN45 Gel Stent implantation is effective in lowering IOP in open-angle glaucoma. Transient numerical hypotony is the most common postoperative complication. Sight-threatening complications are rare. Postoperative needling may be required to maintain IOP-lowering outcomes; however, the overall quality of current evidence is low, with the need for more randomized controlled trials and outcomes measured with a clinically meaningful definition of success.
Topics: Glaucoma Drainage Implants; Glaucoma, Open-Angle; Humans; Intraocular Pressure; Stents; Tonometry, Ocular; Treatment Outcome
PubMed: 35081414
DOI: 10.1016/j.survophthal.2022.01.003 -
Ophthalmic Genetics Apr 2022To investigate the penetrance of gene mutation in primary open-angle glaucoma (POAG) through systematic review and meta-analysis. To explore the factors affecting the... (Meta-Analysis)
Meta-Analysis
PURPOSE
To investigate the penetrance of gene mutation in primary open-angle glaucoma (POAG) through systematic review and meta-analysis. To explore the factors affecting the penetrance of and provide evidence-based medical evidence for clinical work.
METHODS
We searched all studies that reported the penetrance of mutation in PubMed, Embase, Web of Science, and Chinese databases including Wanfang, CNKI (China National Knowledge Infrastructure), and CBM (China Bio-Med). Random effects meta-analysis was conducted to estimate the penetrance of mutation in POAG.
RESULTS
Fifty-two studies were included in this analysis after screening. Meta-analysis of the penetrance of mutation showed that the penetrance of mutation in POAG was 60% (95% CI: 51.0% to 68.0%) and the penetrance of mutation in POAG and suspected POAG was 68% (95% CI: 60.0% to 75.0%). The penetrance of mutation increases with age. Among Caucasians, Asians, and Africans, the penetrance of mutation in POAG was 55%, 71%, 54%, respectively, and the penetrance of mutation in POAG and suspected POAG was 64%, 83%, and 57%, respectively. Besides, the penetrance of different mutation sites was significantly discrepant. The penetrance of mutation in POAG ranged from 10.3% to 100% depending on the mutation sites. Some mutation sites have a certain population specificity, which is only pathogenic in Caucasians or Asians.
CONCLUSIONS
The penetrance of mutation in POAG showed significant differences due to different mutation sites. The penetrance increased with the accrescent of age. Ethnic difference was an important factor affecting the penetrance of mutation. Knowing the rules and influencing factors of the penetrance of mutations is significant for the assessment of the risk of POAG in carriers with the mutation.
Topics: Cytoskeletal Proteins; DNA Mutational Analysis; Eye Proteins; Glaucoma, Open-Angle; Glycoproteins; Humans; Mutation; Penetrance
PubMed: 35014583
DOI: 10.1080/13816810.2021.2021427