Clinical Ophthalmology (Auckland, N.Z.) 2023Recent advances in telemedicine have led to increased use of digital ophthalmoscopes (DO) in clinical settings. This review aims to assess commercially available DOs,... (Review)
Review
PURPOSE
Recent advances in telemedicine have led to increased use of digital ophthalmoscopes (DO) in clinical settings. This review aims to assess commercially available DOs, including smartphone (SP), desktop, and handheld ophthalmoscopes, and evaluate their applications.
METHODS
A literature review was performed by searching PubMed (pubmed.ncbi.nlm.nih.gov), Web of Science (webofknowledge.com), and Science Direct (sciencedirect.com). All English-language papers that resulted from the search terms "digital ophthalmoscope", "screening tool", "glaucoma screening", "diabetic retinopathy screening", "cataract screening", and "papilledema screening" were reviewed. Studies that contained randomized clinical trials with human participants between January 2010 and December 2020 were included. The Risk of Bias in Systematic Reviews (ROBIS) tool was used to assess the methodological quality of each included paper.
RESULTS
Of the 1307 studies identified, 35 met inclusion and exclusion criteria. The ROBIS tool determined that 29/35 studies (82.8%) had a low risk of bias, 3/35 (8.5%) had a moderate risk of bias, and 3/35 (8.5%) had a high risk of bias.
CONCLUSION
The continued adoption of DOs remains uncertain because of concerns about the image quality for non-mydriatic eyes and the confidence in data captured from the device. Likewise, there is a lack of guidelines for the use of DOs, which makes it difficult for providers to determine the best device for their practice and to ensure appropriate use. Even so, DOs continue to gain acceptance as technology and practice integration improve, especially in underserved areas with limited access to ophthalmologists.
PubMed: 37822326
DOI: 10.2147/OPTH.S423845 -
Survey of Ophthalmology 2023Retromode scanning laser ophthalmoscopy imaging captures a pseudo-3-dimensional image of the ocular fundus. Retromode scanning laser ophthalmoscopy imaging was... (Review)
Review
Retromode scanning laser ophthalmoscopy imaging captures a pseudo-3-dimensional image of the ocular fundus. Retromode scanning laser ophthalmoscopy imaging was introduced first in 2008 using the Nidek F-10 scanning laser ophthalmoscope (F-10; Nidek Co., Gamagori, Japan). At that time, no major role was described for this imaging modality. The interest in retromode scanning laser ophthalmoscopy imaging is reemerging with the recent advent of the Mirante that combines scanning laser ophthalmoscopy and optical coherence tomography (Nidek Co., Gamagori, Japan) that can capture retromode images of the fundus. We summarize the findings and clinical implications of retromode imaging using the Nidek F-10 and the Mirante in retinal diseases with the aim of helping researchers direct their future studies.
Topics: Humans; Retinal Diseases; Ophthalmoscopy; Fundus Oculi; Tomography, Optical Coherence
PubMed: 37481077
DOI: 10.1016/j.survophthal.2023.07.004 -
Frontiers in Neuroscience 2022Diabetic retinopathy (DR) is one of the major complications of diabetic eye diseases, causing vision loss and blindness worldwide. The concept of diabetic retinopathy...
Diabetic retinopathy (DR) is one of the major complications of diabetic eye diseases, causing vision loss and blindness worldwide. The concept of diabetic retinopathy has evolved from microvascular disease into more complex neurovascular disorders. Early in the disease progression of diabetes, the neuronal and glial cells are compromised before any microvascular abnormalities clinically detected by the ophthalmoscopic examination. This implies understanding the pathophysiological mechanisms at the early stage of disease progression especially due to diabetes-induced metabolic alterations to damage the neural retina so that early intervention and treatments options can be identified to prevent and inhibit the progression of DR. Hyperglycemia has been widely considered the major contributor to the progression of the retinal damage, even though tight control of glucose does not seem to have a bigger effect on the incidence or progression of retinal damage that leads to DR. Emerging evidence suggests that besides diabetes-induced hyperglycemia, dyslipidemia and amino acid defects might be a major contributor to the progression of early neurovascular retinal damage. In this review, we have discussed recent advances in the alterations of key metabolites of carbohydrate, lipid, and amino acids and their implications for neurovascular damage in DR.
PubMed: 35911994
DOI: 10.3389/fnins.2022.938029 -
Journal of AAPOS : the Official... Apr 2022To synthesize the literature assessing the diagnostic accuracy of telemedicine evaluation compared with clinical examination for retinopathy of prematurity (ROP) in... (Review)
Review
Comparing the diagnostic accuracy of telemedicine utilization versus in-person clinical examination for retinopathy of prematurity in premature infants: a systematic review.
PURPOSE
To synthesize the literature assessing the diagnostic accuracy of telemedicine evaluation compared with clinical examination for retinopathy of prematurity (ROP) in premature infants.
METHODS
Covidence software was used to conduct a systematic literature search from September 14, 2020, through September 27, 2020, on MEDLINE (Ovid), EMBASE (Ovid), CINAHL, and the gray literature to identify studies relevant to telemedicine utilization for ROP detection. After duplicate removal and two-levels of screening, studies comparing telemedicine evaluation with binocular indirect ophthalmoscopic examination were included. Risk of bias assessment was conducted for the included studies following data extraction. A qualitative review was performed to summarize estimates of accuracy of ROP evaluation by telemedicine.
RESULTS
A total of 507 studies were reviewed, of which 323 were found in EMBASE, 115 in MEDLINE, and 79 in CINAHL. Three possibly relevant conference abstracts were found. Following duplicate removal, 410 studies were reviewed based on titles and abstracts. Subsequently, 19 articles were thoroughly examined, and 14 studies (2,655 participants) were included. Most studies found that telemedicine performance for detecting ROP was comparable to ophthalmic examination, especially with regard to identifying treatment-requiring ROP.
CONCLUSIONS
Telemedicine evaluation can reliably detect ROP. Incorporation of telemedicine into conventional neonatal care has the potential to improve access to ROP care.
Topics: Gestational Age; Humans; Infant; Infant, Newborn; Infant, Premature; Ophthalmoscopy; Retinopathy of Prematurity; Telemedicine
PubMed: 35306149
DOI: 10.1016/j.jaapos.2021.12.006 -
American Journal of Otolaryngology 2022The use of smartphones in the United States has more than doubled since 2011. Mobile phone applications have versatile functions in ophthalmology, otolaryngology, and... (Review)
Review
BACKGROUND
The use of smartphones in the United States has more than doubled since 2011. Mobile phone applications have versatile functions in ophthalmology, otolaryngology, and plastic surgery, such as increasing patient engagement in treatment, decreasing no-shows to appointments, and providing patient education. They also provide practical advantages to the clinician, including supplementing an otoscope, laryngoscope, or ophthalmoscope. Their use in oral and maxillofacial surgery (OMFS) and oculoplastic surgery has shown effectiveness for a variety of applications, such as for photography and medical reference. Research suggests that smartphones may improve clinical outcomes and efficiency.
OBJECTIVE
The goal of this study is to provide a comprehensive and up-to-date systematic review of the available literature investigating mobile phone use in oculoplastic surgery and OMFS.
METHODS
A query of terms relevant to oculoplastic surgery and OMFS was conducted using the databases PubMed, CINAHL, Web of Science, and PsychINFO to identify studies meeting inclusion criteria that investigated the implementation, efficacy, and outcomes of mobile device use in oculoplastic surgery and OMFS. A qualitative summary and discussion of the literature was subsequently synthesized.
RESULTS
Out of a total of 289 articles reviewed, 171 were removed due to duplication across the four databases. Of the 118 studies remaining, 19 of them were included within the final qualitative review after screening the abstracts and full text for relevance. The articles were published between 2005 and 2020 from 7 different countries. Review of the relevant articles showed three settings in which mobile devices were used: communication between providers, communication between providers and patients, and as surgical supplementation. The literature review included use of mobile device photography for quality improvement, visual representation of procedures for patient education, and improved communication amongst providers and patients in the setting of oculoplastics and OMFS.
CONCLUSION
Mobile device use has become ubiquitous across cultures worldwide. The literature suggests that mobile phone use in oculoplastic surgery and OMFS may improve clinical practice in multiple settings. However, further investigation is necessary to quantify the clinical benefits of mobile device use in oculoplastic and oral and maxillofacial surgery.
Topics: Appointments and Schedules; Cell Phone; Computers, Handheld; Humans; Surgery, Oral; Text Messaging
PubMed: 34893349
DOI: 10.1016/j.amjoto.2021.103282 -
JAMA Ophthalmology Jan 2021Red reflex testing is a simple and inexpensive method implemented in many countries as an important part of infant screening for ocular pathologies. (Meta-Analysis)
Meta-Analysis
IMPORTANCE
Red reflex testing is a simple and inexpensive method implemented in many countries as an important part of infant screening for ocular pathologies.
OBJECTIVES
To review the literature on the diagnostic accuracy of the red reflex test in infant screening for ocular pathologies and to perform meta-analyses to provide summary estimates.
DATA SOURCES
The following literature databases were searched for English-language, peer-reviewed literature, published until April 19, 2020: Cochrane Central, PubMed/MEDLINE, Embase, Web of Science Core Collection, BIOSIS Previews, Current Contents Connect, Data Citation Index, Derwent Innovations Index, KCI-Korean Journal Database, Russian Science Citation Index, SciELO Citation Index, CINAHL (Cumulative Index to Nursing and Allied Health Literature), and ClinicalTrials.gov.
STUDY SELECTION
Eligibility criteria were defined according to population (studies of consecutively screened infants), exposure (red reflex or Brückner test as the index test), comparator (any ophthalmological examination), and study type (any study with diagnostic test accuracy data).
DATA EXTRACTION AND SYNTHESIS
The Preferred Reporting Items for Systematic Reviews and Meta-Analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines were followed. Data were extracted independently by 2 authors. For summary estimates of diagnostic test accuracy, the hierarchical summary receiver operating characteristics curve was used. Prevalence of ocular pathologies was introduced for a prevalence meta-analysis, which was then used in calculations of diagnostic accuracy of the red reflex test when applied in infant screening.
MAIN OUTCOMES AND MEASURES
True-positive, false-positive, true-negative, and false-negative findings; sensitivity; specificity; and positive and negative predictive values.
RESULTS
In this meta-analysis, 8713 unique infants from 5 unique studies were eligible for qualitative and quantitative review. All studies used the red reflex test without pupillary dilation and were compared with a reference test performed with pupillary dilation. For any ocular pathology, an estimated sensitivity of 7.5% (95% CI, 7.4%-7.5%) and specificity of 97.5% (95% CI, 97.5%-97.5%) was found. Focusing on ocular pathologies that required a medical or surgical intervention, sensitivity improved to 17.5% (95% CI, 0.8%-84.8%) and specificity remained high at 97.6% (95% CI, 87.7%-99.6%).
CONCLUSIONS AND RELEVANCE
These findings suggest that an abnormal red reflex finding most likely reflects an underlying ocular pathology. However, a normal red reflex finding during screening does not exclude ocular disease.
Topics: Humans; Infant; Infant, Newborn; Neonatal Screening; Ophthalmoscopes; Ophthalmoscopy; Predictive Value of Tests; Refraction, Ocular; Refractive Errors; Reproducibility of Results; Vision Screening; Vision, Ocular
PubMed: 33180103
DOI: 10.1001/jamaophthalmol.2020.4854 -
Eye (London, England) Oct 2020To evaluate all simulation models for ophthalmology technical and non-technical skills training and the strength of evidence to support their validity and effectiveness.... (Review)
Review
To evaluate all simulation models for ophthalmology technical and non-technical skills training and the strength of evidence to support their validity and effectiveness. A systematic search was performed using PubMed and Embase for studies published from inception to 01/07/2019. Studies were analysed according to the training modality: virtual reality; wet-lab; dry-lab models; e-learning. The educational impact of studies was evaluated using Messick's validity framework and McGaghie's model of translational outcomes for evaluating effectiveness. One hundred and thirty-one studies were included in this review, with 93 different simulators described. Fifty-three studies were based on virtual reality tools; 47 on wet-lab models; 26 on dry-lab models; 5 on e-learning. Only two studies provided evidence for all five sources of validity assessment. Models with the strongest validity evidence were the Eyesi Surgical, Eyesi Direct Ophthalmoscope and Eye Surgical Skills Assessment Test. Effectiveness ratings for simulator models were mostly limited to level 2 (contained effects) with the exception of the Sophocle vitreoretinal surgery simulator, which was shown at level 3 (downstream effects), and the Eyesi at level 5 (target effects) for cataract surgery. A wide range of models have been described but only the Eyesi has undergone comprehensive investigation. The main weakness is in the poor quality of study design, with a predominance of descriptive reports showing limited validity evidence and few studies investigating the effects of simulation training on patient outcomes. More robust research is needed to enable effective implementation of simulation tools into current training curriculums.
Topics: Clinical Competence; Computer Simulation; Humans; Ophthalmology; Simulation Training; Virtual Reality
PubMed: 32203241
DOI: 10.1038/s41433-020-0832-1 -
Asia-Pacific Journal of Ophthalmology... 2015This systematic review was performed to estimate the diagnostic accuracy of the confocal scanning laser ophthalmoscopy in diagnosing glaucoma. We did a sensitive... (Meta-Analysis)
Meta-Analysis Review
This systematic review was performed to estimate the diagnostic accuracy of the confocal scanning laser ophthalmoscopy in diagnosing glaucoma. We did a sensitive electronic search to find relevant studies. Two reviewers independently screened relevant articles and extracted required data about study methods and reported results of sensitivity and specificity. A meta-analysis was conducted for pooling data to compare different editions of the Heidelberg Retina Tomograph (HRT) with one of its alternatives, scanning laser polarimetry (GDx) with the criteria of "visual field defect" and "changes of nerve fiber layer" as the reference standard. We identified 37 evaluations from 28 relevant primary studies. In these studies, 9573 eyes (4883 glaucomatous and 4689 non-glaucomatous) were assessed with regards to the reference standard using one of the HRT editions with or without GDx. Diagnostic odds ratios were 9.35 [95% confidence interval (CI): 7.58-11.53] for HRT, 11.84 (95% CI: 9.97-14.06) for HRT II, 11.86 (95% CI: 9.16-15.35) for HRT III, and 21.33 (95% CI, 13.56-33.55) for GDx. Although GDx was more accurate than HRT, all editions of HRT had acceptable performance in diagnosing glaucomatous eyes with an ophthalmologist's clinical examination as the reference standard.
Topics: Diagnostic Techniques, Ophthalmological; Glaucoma; Humans; Microscopy, Confocal; Ophthalmoscopy; Scanning Laser Polarimetry; Sensitivity and Specificity; Visual Field Tests; Visual Fields
PubMed: 26068611
DOI: 10.1097/APO.0000000000000085 -
The British Journal of Ophthalmology Mar 2015Retinopathy of prematurity (ROP) is one of the leading and preventable causes of blindness. The investigation of choice for diagnosing ROP is binocular indirect... (Review)
Review
Retinopathy of prematurity (ROP) is one of the leading and preventable causes of blindness. The investigation of choice for diagnosing ROP is binocular indirect ophthalmoscope (BIO) done by ophthalmologists. Since the number of ophthalmologists available to do BIO examination is limited, especially in developing countries, there is a need for an alternate, cheap, reliable and feasible test. Telemedicine imaging with Digital Retinal Photography (DRP) is one such alternate diagnostic test which can be performed easily by non-ophthalmologists, with adequate training. Our objective was to conduct a systematic review to evaluate the accuracy of DRP performed by trained personnel (non-ophthalmologists) in diagnosing clinically significant ROP. Medline, EMBASE, CINAHL and Cochrane databases were searched independently by two authors. Eligible studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. Six were included in the review (three prospective; N=120, three retrospective; N=579). Studies had methodological limitations on QUADAS-2. Because of the heterogeneity of studies, data could not be pooled to derive single-effect size estimates for sensitivity and specificity. The included studies reported sensitivity of 45.5-100% with the majority being more than 90%; specificity 61.7-99.8% with the majority being more than 90%, positive predictive value 61.5-96.6% and negative predictive value of 76.9-100% for diagnosing clinically significant ROP. We conclude that diagnostic accuracy of DRP must be established in prospective studies with adequate sample size where DRP is compared against the simultaneously performed BIO examination.
Topics: Allied Health Personnel; Databases, Factual; Diagnostic Techniques, Ophthalmological; False Positive Reactions; Humans; Infant, Newborn; Neonatal Screening; Photography; Predictive Value of Tests; Quality Assurance, Health Care; Reproducibility of Results; Retinopathy of Prematurity; Sensitivity and Specificity
PubMed: 25001320
DOI: 10.1136/bjophthalmol-2014-304984 -
Acta Ophthalmologica Feb 2015Prophylactic treatment of retinal breaks has been examined in several studies and reviews, but so far, no studies have successfully applied a systematic approach. In the... (Review)
Review
Prophylactic treatment of retinal breaks has been examined in several studies and reviews, but so far, no studies have successfully applied a systematic approach. In the present systematic review, we examined the need of follow-up after posterior vitreous detachment (PVD) - diagnosed by slit-lamp biomicroscopy or Goldmann 3-mirror examination - with regard to retinal breaks as well as the indication of prophylactic treatment in asymptomatic and symptomatic breaks. A total of 2941 publications were identified with PubMed and Medline searches. Two manual search strategies were used for papers in English published before 2012. Four levels of screening identified 13 studies suitable for inclusion in this systematic review. No meta-analysis was conducted as no data suitable for statistical analysis were identified. In total, the initial examination after symptomatic PVD identified 85-95% of subsequent retinal breaks. Additional retinal breaks were only revealed at follow-up in patients where a full retinal examination was compromised at presentation by, for example, vitreous haemorrhage. Asymptomatic and symptomatic retinal breaks progressed to rhegmatogenous retinal detachment (RRD) in 0-13.8% and 35-47% of cases, respectively. The cumulated incidence of RRD despite prophylactic treatment was 2.1-8.8%. The findings in this review suggest that follow-up after symptomatic PVD is only necessary in cases of incomplete retinal examination at presentation. Prophylactic treatment of symptomatic retinal breaks must be considered, whereas no unequivocal conclusion could be reached with regard to prophylactic treatment of asymptomatic retinal breaks.
Topics: Cryosurgery; Humans; Laser Coagulation; Retinal Detachment; Retinal Perforations; Slit Lamp; Vitreous Detachment
PubMed: 24853827
DOI: 10.1111/aos.12447