Resuscitation Plus Sep 2024To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. (Review)
Review
AIM
To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth.
METHODS
A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence.
RESULTS
Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes.
LIMITATIONS
Certainty of evidence was low or very low for most comparisons.
CONCLUSION
If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.
PubMed: 38912532
DOI: 10.1016/j.resplu.2024.100668 -
European Journal of Pediatrics Jun 2024Cerebral monitoring during immediate fetal-to-neonatal transition is of increasing interest. The cerebral fractional tissue oxygen extraction (cFTOE) is a useful... (Review)
Review
UNLABELLED
Cerebral monitoring during immediate fetal-to-neonatal transition is of increasing interest. The cerebral fractional tissue oxygen extraction (cFTOE) is a useful parameter to gain insight in the balance between tissue oxygen delivery and consumption during this complex process. The aim of this study was to review the literature on cFTOE during the first 15 min immediately after birth. A systematic qualitative literature research was last performed on 23 November 2023 of PubMed and EMBASE with the following search terms: neonate, infant, newborn, transition, after birth, delivery room, NIRS, near-infrared spectroscopy, spectroscopy, cFTOE, cerebral fractional tissue oxygenation extraction, cerebral oxygenation, and fractional oxygen extraction. Additional published reports were identified through a manual search of references in retrieved articles and in review articles. The methodological quality of the included studies was assessed by predefined quality criteria. Only human studies with data of cFTOE in the first 15 min after birth were included. Accordingly, exclusion criteria were defined as no measurement of cFTOE or no measurement within the first 15 min after birth. Across all studies, a total of 3566 infants (2423 term, 1143 preterm infants) were analysed. Twenty-five studies were identified describing cFTOE within the first 15 min after birth. Four studies established reference ranges for cFTOE and another four studies focused on the effect of pre-/perinatal circumstances on cFTOE in the first 15 min after birth. Six studies investigated the course of cFTOE after transition in infants without complications. Eleven studies analysed different potentially influencing parameters on cFTOE during transition.
CONCLUSION
This systematic review provides a comprehensive insight on cFTOE during uncomplicated transition as well as the influence of perinatal circumstances, respiratory, haemodynamic, neurological, and laboratory parameters in preterm and term infants.
WHAT IS KNOWN
• The NIRS-measured cerebral fractional tissue oxygen extraction (cFTOE) is a useful parameter to estimate the balance between oxygen delivery and consumption. • During normal transition, the cFTOE decreases in the first minutes after birth and then remains at a stable plateau.
WHAT IS NEW
• The cFTOE is a promising parameter that gives additional information on cerebral oxygenation and perfusion in preterm and term infants. • Several hemodynamic, metabolic, respiratory, and perinatal factors are identified, influencing the oxygen extraction of the newborn's brain after birth.
PubMed: 38861023
DOI: 10.1007/s00431-024-05631-2 -
Frontiers in Pharmacology 2024The benefits of low-dose esketamine for painless gastrointestinal endoscopy remain unclear. As such, the present study aimed to investigate the efficacy and safety of...
The benefits of low-dose esketamine for painless gastrointestinal endoscopy remain unclear. As such, the present study aimed to investigate the efficacy and safety of low-dose esketamine for this procedure. Seven common databases were searched for clinical studies investigating low-dose esketamine for painless gastrointestinal endoscopy. Subsequently, a meta-analysis was performed to synthesize and analyze the data extracted from studies fulfilling the inclusion criteria. Meta-analysis revealed that, compared with propofol, low-dose esketamine in combination with propofol significantly reduced recovery time by 0.56 min (mean difference [MD] -0.56%, 95% confidence interval (CI) -1.08 to -0.05, = 0.03), induction time by 9.84 s (MD -9.84, 95% CI -12.93 to -6.75, < 0.00001), propofol dosage by 51.05 mg (MD -51.05, 95% CI -81.53 to -20.57, = 0.01), and increased mean arterial pressure by 6.23 mmHg (MD 6.23, 95% CI 1.37 to 11.08, = 0.01). Meanwhile, low-dose esketamine reduced injection pain by 63% (relative risk [RR] 0.37, 95% CI 0.28 to 0.49, < 0.00001), involuntary movements by 40% (RR 0.60, 95% Cl 0.42 to 0.85, < 0.005), choking by 42% (RR 0.58, 95% Cl 0.38 to 0.88, = 0.01), bradycardia by 68% (RR 0.32, 95% Cl 0.18 to 0.58, = 0.0002), hypotension by 71% (RR 0.29, 95% Cl 0.21 to 0.40, < 0.00001), respiratory depression by 63% (RR 0.37, 95% 0.26 to 0.51, < 0.00001), additional cases of propofol by 53% (RR 0.47, 95% Cl 0.29 to 0.77, = 0.002), and increased hypertension by 1000% (RR 11.00, 95% Cl 1.45 to 83.28, = 0.02). There were no significant differences in mean heart rate, mean oximetry saturation, delirium, dizziness, vomiting, tachycardia, and hypoxemia. Subgroup analyses revealed that, compared with other dose groups, 0.25 mg/kg esketamine afforded additional benefits in recovery and induction time, mean arterial pressure, involuntary movements, hypoxemia, and respiratory depression. Low-dose esketamine was found to be safe and effective for providing anesthesia during gastrointestinal endoscopy, with 0.25 mg/kg identified as the optimal dose within the dosage ranges examined. However, caution should be exercised when administering this drug to patients with inadequate preoperative blood pressure control.
PubMed: 38645560
DOI: 10.3389/fphar.2024.1364546 -
Revista Da Escola de Enfermagem Da U S P 2024To determine the accuracy of the Pulse Oximetry Test (POT) in screening for Congenital Heart Diseases (CHD) in newborns in the first 48 hours of life. (Meta-Analysis)
Meta-Analysis
OBJECTIVE
To determine the accuracy of the Pulse Oximetry Test (POT) in screening for Congenital Heart Diseases (CHD) in newborns in the first 48 hours of life.
METHOD
Systematic review of diagnostic test accuracy with meta-analysis. The selection of studies was carried out in June 2021. Studies were selected with newborns, in a hospital or home environment, without a previous diagnosis of CHD, regardless of gestational age at birth, who underwent POT within the first 48 hours after birth. Registration on the PROSPERO platform - CRD42021256286.
RESULTS
Twenty-nine studies were included, totaling a population of 388,491 newborns. POT demonstrated sensitivity of 47% (95% CI: 43% to 50%) and specificity of 98% (95% CI: 98% to 98%). Subgroup analyses were carried out according to the different testing period, inclusion of retests in protocols and population of premature newborns.
CONCLUSION
POT is a test with moderate sensitivity and high specificity. It is more effective when carried out within 24h - 48h of birth; in protocols that present retests, within two hours after the first measurement. It does not show satisfactory effectiveness for premature newborns.
Topics: Humans; Infant, Newborn; Sensitivity and Specificity; Neonatal Screening; Oximetry; Hospitals; Heart Defects, Congenital
PubMed: 38426937
DOI: 10.1590/1980-220X-REEUSP-2023-0215en -
Critical Care Explorations Feb 2024Near-infrared spectroscopy (NIRS) is used in critical care settings to measure regional cerebral tissue oxygenation (rSo). However, the accuracy of such measurements has... (Review)
Review
OBJECTIVES
Near-infrared spectroscopy (NIRS) is used in critical care settings to measure regional cerebral tissue oxygenation (rSo). However, the accuracy of such measurements has been questioned in darker-skinned individuals due to the confounding effects of light absorption by melanin. In this systematic review, we aim to synthesize the available evidence on the effect of skin pigmentation on rSo readings.
DATA SOURCES
We systematically searched MEDLINE, Cochrane Database of Systematic Reviews, Embase, and Google Scholar from inception to July 1, 2023.
STUDY SELECTION
In compliance with our PROSPERO registration (CRD42022347548), we selected articles comparing rSo measurements in adults either between racial groups or at different levels of skin pigmentation. Two independent reviewers conducted full-text reviews of all potentially relevant articles.
DATA EXTRACTION
We extracted data on self-reported race or level of skin pigmentation and mean rSo values.
DATA SYNTHESIS
Of the 11,495 unique records screened, two studies ( = 7,549) met our inclusion criteria for systematic review. Sun et al (2015) yielded significantly lower rSo values for African Americans compared with Caucasians, whereas Stannard et al (2021) found little difference between self-reported racial groups. This discrepancy is likely because Stannard et al (2021) used a NIRS platform which specifically purports to control for the effects of melanin. Several other studies that did not meet our inclusion criteria corroborated the notion that skin pigmentation results in lower rSo readings.
CONCLUSIONS
Skin pigmentation likely results in attenuated rSo readings. However, the magnitude of this effect may depend on the specific NIRS platform used.
PubMed: 38352943
DOI: 10.1097/CCE.0000000000001049 -
Sports Medicine (Auckland, N.Z.) Apr 2024In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy...
BACKGROUND
In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.
OBJECTIVES
Considering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized.
METHODS
Preferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation.
RESULTS
Of the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions.
CONCLUSIONS
Although the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Topics: Humans; Oximetry; Muscle, Skeletal; Spectroscopy, Near-Infrared; Oxygen Consumption; Sports Medicine
PubMed: 38345731
DOI: 10.1007/s40279-023-01987-x -
BJS Open Jan 2024Point-of-care tests (POCT) for haemoglobin are increasingly used to guide intraoperative transfusion. However, their accuracy compared to central laboratory tests is... (Meta-Analysis)
Meta-Analysis
BACKGROUND
Point-of-care tests (POCT) for haemoglobin are increasingly used to guide intraoperative transfusion. However, their accuracy compared to central laboratory tests is unknown. The objective was to perform a systematic review and meta-analysis of method comparison studies assessing the accuracy of POCT versus central laboratory haemoglobin tests in patients undergoing surgery.
METHODS
Electronic databases were searched from inception to April 2020 (updated August 2023). Any methodological approach comparing haemoglobin measurements between POCT and central laboratory in patients undergoing surgery under anaesthesia in the operating room were included. Data abstraction was guided by PRISMA and risk of bias was assessed by QUADAS-2. Data were extracted independently and in duplicate by two reviewers. Outcomes included mean differences between POCT and central laboratory haemoglobin with associated standard deviations and 95% limits of agreement (LOA).
RESULTS
Of 3057 citations, 34 studies were included (n = 2427, 6857 paired measurements). Several devices were compared (pulse co-oximetry, n = 25; HemoCue, n = 10; iSTAT, n = 6; blood gas analysers, n = 10; haematology analyser, n = 2). Median sample size was 41 patients, and 11 studies were funded by device manufacturers. Fifteen of 34 studies had low risk of bias. Pooled mean differences (95% LOA) were: pulse co-oximeters 2.3 g/l (-25.2-29.8), HemoCue -0.3 g/l (-11.1-10.5), iSTAT -0.3 g/l (-8.4-7.8) and blood gas analysers -2.6 g/l (-17.8-12.7).
CONCLUSION
All POCT examining intraoperative haemoglobin measurement yielded pooled mean difference LOAs larger than the allowable limit difference of ±4 g/dl. Intraoperative haemoglobin measured by POCT should not be considered interchangeable with central laboratory values and caution is necessary when using these tests to guide intraoperative transfusion.
Topics: Humans; Anesthesia; Hemoglobins; Operating Rooms
PubMed: 38266123
DOI: 10.1093/bjsopen/zrad148 -
Perfusion Jan 2024The decision regarding intraoperative transfusion has traditionally been based on hemodynamic instability and estimated blood loss. We performed a systematic review to... (Review)
Review
BACKGROUND
The decision regarding intraoperative transfusion has traditionally been based on hemodynamic instability and estimated blood loss. We performed a systematic review to determine the validity of the oximetry method compared to standard of care for hemoglobin measurement.
METHODS
A systematic literature review was conducted, and several libraries were searched from inception to March 31,2023. The primary outcome was comparing the mean difference between laboratory-derived hemoglobin and non-invasive, point-of-care hemoglobin measurement. Subgroup analysis included comparing the mean difference in the pediatric population and among female patients.
RESULTS
A total of 276 studies were identified, and 37 were included. We found that the pooled mean difference varied qualitatively between adult and pediatric population ( value for heterogeneity <0.001). In adult populations, lab hemoglobin measurements were on average slightly higher than non-invasive measurements (mean difference = 0.23; 95% CI -0.13, 0.59), though there was greater heterogeneity across studies (I2 = 97%, value = <0.001). In the pediatric population, most studies showed lab hemoglobin to be slightly lower (mean difference = -0.42; 95% CI -0.87 to 0.03).
CONCLUSIONS
In general, there was no clinically significant difference in mean hemoglobin among adult and pediatric populations. The percentage of female participants had no effect on the mean difference in hemoglobin.
PubMed: 38231793
DOI: 10.1177/02676591241226465 -
Frontiers in Medicine 2023Acute carbon monoxide poisoning (COP) is one of the leading causes of intoxication among patients presenting to the emergency department (ED). COP symptoms are not...
INTRODUCTION
Acute carbon monoxide poisoning (COP) is one of the leading causes of intoxication among patients presenting to the emergency department (ED). COP symptoms are not always specific and may vary from mild to critical. In the last few years, COHb pulse oximeters have been developed and applied to the setting of suspected COP. The aim of this systematic review is to assess the diagnostic accuracy of CO pulse oximetry (SpCO) with carboxyhemoglobin (COHb) levels measured by blood gas analysis, used as a reference standard, in patients with suspected COP.
METHODS
We developed our search strategy according to the PICOS framework, population, index/intervention, comparison, outcome, and study, considering the diagnostic accuracy of SpCO compared to COHb levels measured by blood gas analysis, used as a reference standard, in patients with suspected COP enrolled in cross-sectional studies in English. The search was performed on MEDLINE/PubMed and EMBASE in February 2022. Quality assessment was performed using the QUADAS-2 methodology. A COHb cutoff of 10% was chosen to test the sensitivity and specificity of the index test. A bivariate model was used to perform the meta-analysis. The protocol was registered on PROSPERO (CRD42022359144).
RESULTS
A total of six studies (1734 patients) were included. The pooled sensitivity of the test was 0.65 (95% CI 0.44-0.81), and the pooled specificity was 0.93 (95% CI 0.83-0.98). The pooled LR+ was 9.4 (95% CI 4.4 to 20.1), and the pooled LR- was 0.38 (95% CI 0.24 to 0.62).
CONCLUSION
Our results show that SpCO cannot be used as a screening tool for COP in the ED due to its low sensitivity. Because of its high LR+, it would be interesting to evaluate, if SpCO could have a role in the prehospital setting as a tool to quickly identify COP patients and prioritize their transport to specialized hospitals on larger samples with a prospective design.
PubMed: 38223786
DOI: 10.3389/fmed.2023.1250845 -
Journal of Pediatric Orthopedics. Part B Dec 2023The supracondylar humeral fracture (SCHF) is the most common fracture seen in children, forming up to 70% of all pediatric elbow fractures. The decision to surgically...
The supracondylar humeral fracture (SCHF) is the most common fracture seen in children, forming up to 70% of all pediatric elbow fractures. The decision to surgically explore the brachial artery in a well-perfused, pulseless arm remains a controversial one among vascular and orthopedic surgeons and is something we seek to explore in this article. We reviewed the literature from electronic databases such as PubMed and Embase for studies focusing on the management of the pink pulseless hand (PPH) following SCHF. We gathered a total of 23 articles to be analyzed in this review. We found 336 PPH postreduction and evaluated the management as well as the follow-up and complications of the PPH involved. Most recent articles have cited the close observation strategy as the most reliable strategy. It is clear that the management of a SCHF requires immediate reduction and fixation. In the management of a postoperatively pulseless pink humerus, we do agree with the latest conclusion of Delionitis et al. who advocate the traditional dogma of watchful waiting in the case of a PPH postreduction and fixation as long as no signs of vascular deterioration appear. However, the outcome of this study also advocates for the monitoring of up to 24-48 h postreduction and the use of noninvasive tools such as ultrasound Doppler, Color flow duplex Ultrasound and pulse oximetry to monitor perfusion as they all have had good outcomes in the articles cited in this review. Still, in the event of vascular deterioration or development of complications of the hand, immediate vascular exploration is still indicated.
PubMed: 38189745
DOI: 10.1097/BPB.0000000000001149