Journal of Global Health Aug 2022WHO pneumonia guidelines recommend that children (aged 2-59 months) with chest indrawing pneumonia and without any "general danger sign" can be treated with oral...
Which children with chest-indrawing pneumonia can be safely treated at home, and under what conditions is it safe to do so? A systematic review of evidence from low- and middle-income countries.
BACKGROUND
WHO pneumonia guidelines recommend that children (aged 2-59 months) with chest indrawing pneumonia and without any "general danger sign" can be treated with oral amoxicillin without hospital admission. This recommendation was based on trial data from limited contexts whose generalisability is unclear. This review aimed to identify which children with chest-indrawing pneumonia in low- and middle-income countries can be safely treated at home, and under what conditions is it safe to do so.
METHODS
We searched MEDLINE, EMBASE, and PubMed for observational and interventional studies of home-based management of children (aged 28 days to four years) with chest-indrawing pneumonia in low- or middle-income countries.
RESULTS
We included 14 studies, including seven randomised trials, from a variety of urban and rural contexts in 11 countries. Two community-based and two hospital-based trials in Pakistan and India found that home treatment of chest-indrawing pneumonia was associated with similar or superior treatment outcomes to hospital admission. Evidence from trials (n = 3) and observational (n = 6) studies in these and other countries confirms the acceptability and feasibility of home management of chest-indrawing pneumonia in low-risk cases, so long as safeguards are in place. Risk assessment includes clinical danger signs, oxygen saturation, and the presence of comorbidities such as undernutrition, anaemia, or HIV. Pulse oximetry is a critical risk-assessment tool that is currently not widely available and can identify severely ill patients with hypoxaemia otherwise possibly missed by clinical assessment alone. Additional safeguards include caregiver understanding and ability to return for review.
CONCLUSIONS
Home treatment of chest-indrawing pneumonia can be safe but should only be recommended for children confirmed to be low-risk and in contexts where appropriate care and safety measures are in place.
Topics: Amoxicillin; Child; Developing Countries; Humans; Infant; Oximetry; Pneumonia; Treatment Outcome
PubMed: 36040992
DOI: 10.7189/jogh.12.10008 -
BMC Medicine Aug 2022During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We... (Meta-Analysis)
Meta-Analysis
BACKGROUND
During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry (SpO) compared with the gold standard SaO measured by CO-oximetry.
METHODS
We searched Ovid MEDLINE, Ovid Embase, EBSCO CINAHL, ClinicalTrials.gov, and WHO International Clinical Trials Registry Platform (up to December 2021) for studies with SpO-SaO comparisons and measuring the impact of skin pigmentation or ethnicity on pulse oximetry accuracy. We performed meta-analyses for mean bias (the primary outcome in this review) and its standard deviations (SDs) across studies included for each subgroup of skin pigmentation and ethnicity and used these pooled mean biases and SDs to calculate accuracy root-mean-square (A) and 95% limits of agreement. The review was registered with the Open Science Framework ( https://osf.io/gm7ty ).
RESULTS
We included 32 studies (6505 participants): 15 measured skin pigmentation and 22 referred to ethnicity. Compared with standard SaO measurement, pulse oximetry probably overestimates oxygen saturation in people with the high level of skin pigmentation (pooled mean bias 1.11%; 95% confidence interval 0.29 to 1.93%) and people described as Black/African American (1.52%; 0.95 to 2.09%) (moderate- and low-certainty evidence). The bias of pulse oximetry measurements for people with other levels of skin pigmentation or those from other ethnic groups is either more uncertain or suggests no overestimation. Whilst the extent of mean bias is small or negligible for all subgroups evaluated, the associated imprecision is unacceptably large (pooled SDs > 1%). When the extent of measurement bias and precision is considered jointly, pulse oximetry measurements for all the subgroups appear acceptably accurate (with A < 4%).
CONCLUSIONS
Pulse oximetry may overestimate oxygen saturation in people with high levels of skin pigmentation and people whose ethnicity is reported as Black/African American, compared with SaO. The extent of overestimation may be small in hospital settings but unknown in community settings. REVIEW PROTOCOL REGISTRATION: https://osf.io/gm7ty.
Topics: COVID-19; Humans; Oximetry; Oxygen; Oxygen Saturation; Pandemics; Skin Pigmentation
PubMed: 35971142
DOI: 10.1186/s12916-022-02452-8 -
International Journal of Environmental... Aug 2022The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal... (Meta-Analysis)
Meta-Analysis Review
The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
Topics: Dentition, Permanent; Hot Temperature; Humans; Oximetry; Reproducibility of Results; Sensitivity and Specificity
PubMed: 35954958
DOI: 10.3390/ijerph19159599 -
Journal of Biomedical Optics Aug 2022Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their... (Review)
Review
SIGNIFICANCE
Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods.
AIM
We aim to provide a systematic overview of the field of hemoglobin imaging and sensing.
APPROACH
We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy.
RESULTS
We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application.
CONCLUSIONS
We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Topics: Hemoglobins; Oximetry; Spectrum Analysis; Tomography, Optical Coherence
PubMed: 35922891
DOI: 10.1117/1.JBO.27.8.080901 -
Children (Basel, Switzerland) May 2022Determining the neonatal heart rate immediately after birth is unsatisfactory. Auscultation is inaccurate and provides no documented results. The use of foetal Doppler... (Review)
Review
Determining the neonatal heart rate immediately after birth is unsatisfactory. Auscultation is inaccurate and provides no documented results. The use of foetal Doppler ultrasound has been recognised as a possible method of determining the neonatal heart rate after birth over the last nine years. This review includes all published studies of this approach, looking at accuracy, speed of results, and practical application of the approach. Precordial Doppler ultrasound has been shown to be as accurate as ECG and more accurate than oximetry for the neonatal heart rate, and provides quicker results than either ECG or oximetry. There is the potential for a much improved determination and documentation of the neonatal heart rate using this approach.
PubMed: 35626893
DOI: 10.3390/children9050717 -
Clinical Oral Investigations Jul 2022To assess whether wearing complete dentures during sleep influences the cardiorespiratory parameters of patients with obstructive sleep apnea (OSA). (Meta-Analysis)
Meta-Analysis Review
OBJECTIVE
To assess whether wearing complete dentures during sleep influences the cardiorespiratory parameters of patients with obstructive sleep apnea (OSA).
MATERIALS AND METHODS
A systematic review was performed based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to determine whether wearing complete dentures during sleep influences the cardiorespiratory parameters of patients with OSA. An electronic search was performed in four databases, PubMed/MEDLINE, Cochrane Library, Web of Science, and SCOPUS, and in the gray literature (TRIALS) until November 2021. This review included clinical trials, randomized clinical trials, and studies in which patients using conventional complete dentures were diagnosed with OSA using polysomnography and the cardiorespiratory parameters were measured using oximetry or polysomnography during sleep.
RESULTS
In total, 788 references were found in the database, and 12 articles were selected for full reading. Six articles were selected for qualitative and quantitative analyses after applying the inclusion and exclusion criteria and reading the full article. The meta-analysis showed that mean oxygen saturation (SpO) increased with the use of complete dentures (p = 0.001), but the other parameters showed no significant differences between those wearing and not wearing dentures during sleep.
CONCLUSIONS
The mean SpO reduced in patients wearing complete dentures, but the other cardiorespiratory parameters evaluated were not affected.
CLINICAL RELEVANCE
This study indicates a possible influence of the use of complete dentures on the mean SpO during sleep. The use of complete denture could aid other treatments in improving respiratory and sleep quality.
Topics: Denture, Complete; Humans; Mouth, Edentulous; Polysomnography; Sleep; Sleep Apnea, Obstructive
PubMed: 35616727
DOI: 10.1007/s00784-022-04517-7 -
Sensors (Basel, Switzerland) Apr 2022Nowadays, pulse oximetry has become the standard in primary and intensive care units, especially as a triage tool during the current COVID-19 pandemic. Hence, a deeper... (Review)
Review
Nowadays, pulse oximetry has become the standard in primary and intensive care units, especially as a triage tool during the current COVID-19 pandemic. Hence, a deeper understanding of the measurement errors that can affect precise readings is a key element in clinical decision-making. Several factors may influence the accuracy of pulse oximetry, such as skin color, body temperature, altitude, or patient movement. The skin pigmentation effect on pulse oximetry accuracy has long been studied reporting some contradictory conclusions. Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions. This review aims to study the literature that assesses the influence of skin pigmentation on the accuracy of these devices. We employed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to conduct a systematic review retrospectively since February 2022 using WOS, PubMed, and Scopus databases. We found 99 unique references, of which only 41 satisfied the established inclusion criteria. A bibliometric and scientometrics approach was performed to examine the outcomes of an exhaustive survey of the thematic content and trending topics.
Topics: Bibliometrics; COVID-19; Humans; Oximetry; Oxygen; Pandemics; Retrospective Studies; Skin Pigmentation
PubMed: 35591092
DOI: 10.3390/s22093402 -
PloS One 2022To assess the diagnostic utility of smartphone-based measurement in detecting moderate to severe obstructive sleep apnea syndrome (OSAS). (Meta-Analysis)
Meta-Analysis
OBJECTIVES
To assess the diagnostic utility of smartphone-based measurement in detecting moderate to severe obstructive sleep apnea syndrome (OSAS).
METHODS
Six databases were thoroughly reviewed. Random-effect models were used to estimate the summary sensitivity, specificity, negative predictive value, positive predictive value, diagnostic odds ratio, summary receiver operating characteristic curve and measured the areas under the curve. To assess the accuracy and precision, pooled mean difference and standard deviation of apnea hypopnea index (AHI) between smartphone and polysomnography (95% limits of agreement) across studies were calculated using the random-effects model. Study methodological quality was evaluated using the QUADAS-2 tool.
RESULTS
Eleven studies were analyzed. The smartphone diagnostic odds ratio for moderate-to-severe OSAS (apnea/hypopnea index > 15) was 57.3873 (95% confidence interval [CI]: [34.7462; 94.7815]). The area under the summary receiver operating characteristic curve was 0.917. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.9064 [0.8789; 0.9282], 0.8801 [0.8227; 0.9207], 0.9049 [0.8556; 0.9386], and 0.8844 [0.8234; 0.9263], respectively. We performed subgroup analysis based on the various OSAS detection methods (motion, sound, oximetry, and combinations thereof). Although the diagnostic odds ratios, specificities, and negative predictive values varied significantly (all p < 0.05), all methods afforded good sensitivity (> 80%). The sensitivities and positive predictive values were similar for the various methods (both p > 0.05). The mean difference with standard deviation in the AHI between smartphone and polysomnography was -0.6845 ± 1.611 events/h [-3.8426; 2.4735].
CONCLUSIONS
Smartphone could be used to screen the moderate-to-severe OSAS. The mean difference between smartphones and polysomnography AHI measurements was small, though limits of agreement was wide. Therefore, clinicians should be cautious when making clinical decisions based on these devices.
Topics: Humans; Oximetry; Polysomnography; Predictive Value of Tests; Sleep Apnea, Obstructive; Smartphone
PubMed: 35587944
DOI: 10.1371/journal.pone.0268585 -
American Journal of Perinatology Nov 2023Congenital heart defects (CHDs) are the most common neonatal malformations and are a leading cause of infant death in developed countries. Finding safe and effective... (Meta-Analysis)
Meta-Analysis
Congenital heart defects (CHDs) are the most common neonatal malformations and are a leading cause of infant death in developed countries. Finding safe and effective diagnostic methods to screen for CHDs is important. The aim of this study was to evaluate the effectiveness of pulse oximetry (PO) and perfusion index (PI) in screening CHD. We conducted a systematic review of studies in PubMed, Embase, and the Cochrane Library published on or before October 1, 2021. Studies based on PICOS were included in this systematic review. The flow chart is made by PRISMA software. The quality of included studies was assessed by RevMan5 software (QUADAS-2: Quality Assessment of Diagnostic Accuracy Studies-2). The sensitivity, specificity, and other measurements of accuracy were pooled using Stata/SE 12.0 software. Five studies containing 46,965 neonates were included in this study. A randomized-effects model was used for the meta-analysis because of significant heterogeneity. The combined sensitivity and specificity were 0.82 (95% confidence interval [CI], 0.53-0.95) and 0.97 (95% CI, 0.57-1.00), respectively. The area under the curve was 0.92 (95% CI, 0.89-0.94). The combination PO and PI was significant in CHD screening. Once diagnosed by the combined method, it means that the neonate is most likely to have a CHD. KEY POINTS: · Pulse oximetry and PI screening.. · Congenital heart defects.. · A systematic review and meta-analysis..
Topics: Infant, Newborn; Infant; Humans; Perfusion Index; Neonatal Screening; Oximetry; Sensitivity and Specificity; Heart Defects, Congenital
PubMed: 35580627
DOI: 10.1055/s-0042-1748163 -
Anesthesiology and Pain Medicine Feb 2022One of the main objectives in neurosurgical procedures is the prevention of cerebral ischemia and hypoxia leading to secondary brain injury. Different methods for early...
One of the main objectives in neurosurgical procedures is the prevention of cerebral ischemia and hypoxia leading to secondary brain injury. Different methods for early detection of intraoperative cerebral ischemia and hypoxia have been used. Near-infrared spectroscopy (NIRS) is a simple, non-invasive method for monitoring cerebral oxygenation increasingly used today. The aim of this study was to systematically review the brain monitoring with NIRS in neurosurgery. The search process resulted in the detection of 324 articles using valid keywords on the electronic databases, including Embase, PubMed, Scopus, Web of Science, and Cochrane Library. Subsequently, the full texts of 34 studies were reviewed, and finally 11 articles (seven prospective studies, three retrospective studies, and one randomized controlled trial) published from 2005 to 2020 were identified as eligible for systematic review. Meta-analysis was not possible due to high heterogeneity in neurological and neurosurgical conditions of patients, expression of different clinical outcomes, and different standard reference tests in the studies reviewed. The results showed that NIRS is a non-invasive cerebral oximetry that provides continuous and measurable cerebral oxygenation information and can be used in a variety of clinical settings.
PubMed: 35433374
DOI: 10.5812/aapm.116637