Radiotherapy and Oncology : Journal of... May 2024Stereotactic ablative radiation therapy (SBRT) is an emerging treatment option for primary renal cell carcinoma (RCC), particularly in patients who are unsuitable for... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Stereotactic ablative radiation therapy (SBRT) is an emerging treatment option for primary renal cell carcinoma (RCC), particularly in patients who are unsuitable for surgery. The aim of this review is to assess the effect of increasing the biologically equivalent dose (BED) via various radiation fractionation regimens on clinical outcomes.
METHODS
A literature search was conducted in PubMed (Medline), EMBASE, and the Cochrane Library for studies published up to October 2023. Studies reporting on patients with localized RCC receiving SBRT were included to determine its effectiveness on local control, progression-free survival, and overall survival. A random effects model was used to meta-regress clinical outcomes relative to the BED for each study and heterogeneity was assessed by I.
RESULTS
A total of 724 patients with RCC from 22 studies were included, with a mean age of 72.7 years (range: 44.0-81.0). Local control was excellent with an estimate of 99 % (95 %CI: 97-100 %, I = 19 %), 98 % (95 %CI: 96-99 %, I = 8 %), and 94 % (95 %CI: 90-97 %, I = 11 %) at one year, two years, and five years respectively. No definitive association between increasing BED and local control, progression-free survival and overall survival was observed. No publication bias was observed.
CONCLUSIONS
A significant dose response relationship between oncological outcomes and was not identified, and excellent local control outcomes were observed at the full range of doses. Until new evidence points otherwise, we support current recommendations against routine dose escalation beyond 25-26 Gy in one fraction or 42-48 Gy in three fractions, and to consider de-escalation or compromising target coverage if required to achieve safe organ at risk doses.
Topics: Humans; Carcinoma, Renal Cell; Dose Fractionation, Radiation; Dose-Response Relationship, Radiation; Kidney Neoplasms; Treatment Outcome
PubMed: 38462092
DOI: 10.1016/j.radonc.2024.110216 -
American Journal of Ophthalmology Jul 2024This study aims to appraise the therapeutic effectiveness of intravitreal injections anti-vascular endothelial growth factor (anti-VEGF) vs alternative therapies in... (Meta-Analysis)
Meta-Analysis Review
PURPOSE
This study aims to appraise the therapeutic effectiveness of intravitreal injections anti-vascular endothelial growth factor (anti-VEGF) vs alternative therapies in managing radiation retinopathy (RR).
DESIGN
Systematic review and meta-analysis.
METHODS
We obtained comprehensive data retrieval using PubMed, Embase, Web of Science, Scopus, and the Cochrane Library from their inception until December 15, 2023. This review included randomized controlled trials (RCTs) and nonrandomized studies (NRSs) reporting on best-corrected visual acuity (BCVA) among RR patients treated with intravitreal anti-VEGF. Study selection and data extraction were meticulously performed by 2 independent reviewers. The Cochrane Risk of Bias Tool 2.0 (RoB 2.0) and Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) scales were utilized for bias risk assessment. Quantification of heterogeneity was executed using Q, H, and I statistics. The primary endpoint was the BCVA at the final observation point of each study. Secondary endpoints included central retinal thickness (CRT), foveal avascular zone (FAZ) area, and capillary density (CD) at the level of superficial capillary plexus. Subgroup analyses were undertaken to explore potential heterogeneity sources possibly due to treatment duration and study design. Sensitivity analyses were conducted to ascertain result stability.
RESULTS
This analysis incorporated 7 studies (including 3 RCTs) encompassing 922 patients afflicted with RR. Relative to other treatment modalities, intravitreal anti-VEGF therapy was associated with a statistically significant mean decrease in BCVA of -0.34 logMAR (95% CI, -0.39 to -0.30 logMAR; I = 87.70%; P < .001), and a substantial reduction in CRT of -34.65 µm (95% CI, -50.70 to -18.60 µm; I = 30.40%; P < .001). Additionally, a reduction in the FAZ area by -0.69 mm² (95% CI, -0.91 to -0.46 mm², I = 0%; P < .001) was observed. A positive tendency was noted in CD at the superficial capillary plexus between anti-VEGF and other therapeutic interventions.
CONCLUSIONS
Intravitreal anti-VEGF injections, in comparison to other treatments, demonstrate superior efficacy in enhancing BCVA and reducing CRT, thereby underscoring the potential of anti-VEGF in ameliorating radiation retinopathy outcomes. However, the conclusions are constrained by the incorporation of data from some NRSs and the small sample sizes.
Topics: Humans; Intravitreal Injections; Angiogenesis Inhibitors; Vascular Endothelial Growth Factor A; Radiation Injuries; Visual Acuity; Retinal Diseases; Treatment Outcome; Tomography, Optical Coherence
PubMed: 38458409
DOI: 10.1016/j.ajo.2024.02.038 -
The Journal of Craniofacial Surgery Mar 2024Radiographs (XRs), computed tomography (CT) scans, and cone-beam CT (CBCT) scans are utilized for assessment of secondary alveolar bone graft (SABG) in patients with...
INTRODUCTION
Radiographs (XRs), computed tomography (CT) scans, and cone-beam CT (CBCT) scans are utilized for assessment of secondary alveolar bone graft (SABG) in patients with cleft lip and palate (CLP). However, the optimal choice for imaging modality remains unclear. This study compares the image fidelity and safety profile for XR, CT, and CBCT in the assessment of patients with CLP who have undergone SABG.
METHODS
Articles from MEDLINE and Elsevier Embase were screened. The primary outcome was graft success rate. Secondary outcomes were percent-by-volume of graft maintained and patient safety, defined by radiation exposure. A random effects model was used to calculate the pooled outcomes for each imaging modality. Chi-squared analysis was used to compare pooled outcomes between different imaging modalities.
RESULTS
Of the 149 articles identified initially, 14 were included. Computed tomography exhibited a significantly higher image fidelity demonstrated by a lower graft success rate (62.0%) compared with both XR (72.6%, P<0.01) and CBCT (69.8%, P<0.01). Cone-beam CT had the lowest reported percent-by-volume of graft maintained (32.1%). Computed tomography had a higher mean radiation dosage (39.7 milligray) than what has been reported for both XR and CBCT.
CONCLUSION
Computed tomography demonstrated lower graft success rates than both XR and CBCT, possibly indicating a higher image fidelity. However, compared with CBCT, CT may have a higher radiation exposure. Randomized trials and longitudinal studies are necessary to perform a direct comparison between CT and CBCT and to correlate the image fidelity of these modalities with clinical outcomes.
PubMed: 38456609
DOI: 10.1097/SCS.0000000000010033 -
Dento Maxillo Facial Radiology Apr 2024The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those... (Meta-Analysis)
Meta-Analysis
OBJECTIVES
The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols.
METHODS
The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data.
RESULTS
The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible.
CONCLUSION
Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.
Topics: Cone-Beam Computed Tomography; Humans; Radiation Dosage; Patient Care Planning; Dental Implantation, Endosseous; Dental Implants
PubMed: 38429951
DOI: 10.1093/dmfr/twae007 -
Cureus Feb 2024Spinal fusion is a common method by which surgeons decrease instability and deformity of the spinal segment targeted. Pedicle screws are vital tools in fusion surgeries... (Review)
Review
Spinal fusion is a common method by which surgeons decrease instability and deformity of the spinal segment targeted. Pedicle screws are vital tools in fusion surgeries and advancements in technology have introduced several modalities of screw placement. Our objective was to evaluate the accuracy of pedicle screw placement in robot-assisted (RA) versus fluoroscopic-guided (FG) techniques. The PubMed and Cochrane Library databases were systematically reviewed from January 2007 through to August 8, 2022, to identify relevant studies. The accuracy of pedicle screw placement was determined using the Gertzbein-Robbins (GR) classification system. Facet joint violation (FJV), total case radiation dosage, total case radiation time, total operating room (OR) time, and total case blood loss were collected. Twenty-one articles fulfilled the inclusion criteria. Successful screw accuracy (GR Grade A or B) was found to be 1.02 (95% confidence interval: 1.01 - 1.04) times more likely with the RA technique. In defining accuracy solely based on the GR Grade A criteria, screws placed with RA were 1.10 (95% confidence interval: 1.06 - 1.15) times more likely to be accurate. There was no significant difference between the two techniques with respect to blood loss (Hedges' g: 1.16, 95% confidence interval: -0.75 to 3.06) or case radiation time (Hedges' g: -0.34, 95% CI: -1.22 to 0.53). FG techniques were associated with shorter operating room times (Hedges' g: -1.03, 95% confidence interval: -1.76 to -0.31), and higher case radiation dosage (Hedges' g: 1.61, 95% confidence interval: 1.11 to 2.10). This review suggests that RA may slightly increase pedicle screw accuracy and decrease per-case radiation dosage compared to FG techniques. However, total operating times for RA cases are greater than those for FG cases.
PubMed: 38410625
DOI: 10.7759/cureus.54969 -
Clinical and Translational Radiation... Mar 2024This systematic review aims to comprehensively summarize the current prospective evidence regarding Stereotactic Body Radiotherapy (SBRT) in various clinical contexts...
PURPOSE
This systematic review aims to comprehensively summarize the current prospective evidence regarding Stereotactic Body Radiotherapy (SBRT) in various clinical contexts for pancreatic cancer including its use as neoadjuvant therapy for borderline resectable pancreatic cancer (BRPC), induction therapy for locally advanced pancreatic cancer (LAPC), salvage therapy for isolated local recurrence (ILR), adjuvant therapy after radical resection, and as a palliative treatment. Special attention is given to the application of magnetic resonance-guided radiotherapy (MRgRT).
METHODS
Following PRISMA guidelines, a systematic review of the Medline database via PubMed was conducted focusing on prospective studies published within the past decade. Data were extracted concerning study characteristics, outcome measures, toxicity profiles, SBRT dosage and fractionation regimens, as well as additional systemic therapies.
RESULTS AND CONCLUSION
31 studies with in total 1,571 patients were included in this review encompassing 14 studies for LAPC, 9 for neoadjuvant treatment, 2 for adjuvant treatment, 2 for ILR, with an additional 4 studies evaluating MRgRT. In LAPC, SBRT demonstrates encouraging results, characterized by favorable local control rates. Several studies even report conversion to resectable disease with substantial resection rates reaching 39%. The adoption of MRgRT may provide a solution to the challenge to deliver ablative doses while minimizing severe toxicities. In BRPC, select prospective studies combining preoperative ablative-dose SBRT with modern induction systemic therapies have achieved remarkable resection rates of up to 80%. MRgRT also holds potential in this context. Adjuvant SBRT does not appear to confer relevant advantages over chemotherapy. While prospective data for SBRT in ILR and for palliative pain relief are limited, they corroborate positive findings from retrospective studies.
PubMed: 38370495
DOI: 10.1016/j.ctro.2024.100738 -
International Journal of Radiation... Jun 2024Radiation myelitis (RM) is a rare complication of radiation therapy (RT). The Pediatric Normal Tissue Effects in the Clinic spinal cord task force aimed to identify RT... (Review)
Review
PURPOSE
Radiation myelitis (RM) is a rare complication of radiation therapy (RT). The Pediatric Normal Tissue Effects in the Clinic spinal cord task force aimed to identify RT dose effects and assess risk factors for RM in children. Through systematic review, we analyzed RT dose, fraction size, latency between completion of RT and toxicity, chemotherapy use, age when irradiated, and sex.
METHODS AND MATERIALS
We conducted literature searches of peer-reviewed manuscripts published from 1964 to June 2017 evaluating RM among children. Normality of variables was assessed with Kolmogorov-Smirnov or Shapiro-Wilk tests. Spearman's rank correlation coefficients were used to test correlations between RT dose/fraction size and latency between RT and development of toxicity.
RESULTS
Of 1329 identified and screened reports, 144 reports were fully reviewed and determined to have adequate data for analysis; 16 of these reports had a total of 33 cases of RM with a median age of 13 years (range, 0.2-18) at the time of RT. The most common primary tumor histologies were rhabdomyosarcoma (n = 9), medulloblastoma (n = 5), and Hodgkin lymphoma (n = 2); the most common chemotherapy agents given were vincristine (n = 15), intrathecal methotrexate (n = 12), and intrathecal cytarabine (n = 10). The median RT dose and fraction size were 40 Gy (range, 24-57.4 Gy) and 1.8 Gy (range, 1.3-2.6 Gy), respectively. RT dose resulting in RM in patients who also received chemotherapy was lower than in those not receiving chemotherapy (mean 39.6 vs 49.7 Gy; P = .04). There was no association of age with RT dose. The median latency period was 7 months (range, 1-29). Higher RT dose was correlated with longer latency periods (P = .03) to RM whereas sex, age, fraction size, and chemotherapy use were not. Two of 17 patients with adequate follow-up recovered from RM; unfortunately, it was fatal in 6 of 15 evaluable patients. Complication probability modeling was not possible because of the rarity of events.
CONCLUSIONS
This report demonstrates a relatively short latency from RT (with or without chemotherapy) to RM and a wide range of doses (including fraction sizes) associated with RM. No apparent association with age at the time of RT could be discerned. Chemotherapy appears to reduce spinal cord tolerance. Recovery from RM is rare, and it is often fatal.
Topics: Humans; Child; Adolescent; Child, Preschool; Male; Infant; Radiation Injuries; Female; Neoplasms; Radiotherapy Dosage; Myelitis; Medulloblastoma; Risk Factors; Rhabdomyosarcoma; Hodgkin Disease; Age Factors; Spinal Cord Diseases
PubMed: 38323945
DOI: 10.1016/j.ijrobp.2023.12.020 -
Health Physics Mar 2024A comprehensive search was performed to examine the literature on diagnostic reference levels (DRL) for computed tomography (CT) and radiography examinations that are...
A comprehensive search was performed to examine the literature on diagnostic reference levels (DRL) for computed tomography (CT) and radiography examinations that are performed routinely in Jordan. EBSCO, Scopus, and Web of Science were used for the search. The acronym "DRL" and the additional phrase "dose reference levels" were used to search for articles in literature. Seven papers that reported DRL values for radiography and CT scans in Jordan were identified. One study reported DRLs for conventional radiography, two studies reported CT DRLs in pediatrics, and the remaining four studies provided DRL values for adult CT scans. The most popular techniques for determining the DRLs were the entrance surface dose, volume CT dose index (CTDIvol), and dose-length product (DLP) values. Variations in Jordanian DRL values were noted across both modalities. Lower radiation doses and less variation in DRL values may be achieved by educating and training radiographers to better understand dose reduction strategies. To limit dose variance and enable dosage comparison, CT DRLs must be standardized in accordance with the guidelines of the International Commission on Radiological Protection (ICRP).
Topics: Adult; Child; Humans; Jordan; Diagnostic Reference Levels; Tomography, X-Ray Computed; Radiation Protection
PubMed: 38252949
DOI: 10.1097/HP.0000000000001778 -
Wideochirurgia I Inne Techniki... Dec 2023The diagnosis of pulmonary nodules (PNs) has traditionally relied on computed tomography (CT)-guided biopsy. To reduce radiation exposure, low-dose CT-guided PN biopsy...
INTRODUCTION
The diagnosis of pulmonary nodules (PNs) has traditionally relied on computed tomography (CT)-guided biopsy. To reduce radiation exposure, low-dose CT-guided PN biopsy has been employed.
AIM
This meta-analysis aimed at evaluating the efficacy and safety of low-dose CT-guided biopsy in the diagnosis of PNs.
MATERIAL AND METHODS
PubMed, Web of Science, and Wanfang were searched for relevant articles until June 2023. Comparing low-dose CT to normal-dose CT, we considered factors such as diagnostic yield, diagnostic accuracy, biopsy process time, dose-length product (DLP) value, the frequency of pneumothorax and pulmonary bleeding, and the frequency with which complications necessitated the placement of a chest tube.
RESULTS
This meta-analysis included data from a total of 6 investigations. There was a total of 459 patients who had a CT-guided PN biopsy performed at a low dosage, and 384 patients who had a normal-dose CT-guided PN biopsy. There were no statistically significant differences between the low-dose CT and normal-dose CT groups in terms of diagnostic accuracy (p = 0.08), diagnostic yield (p = 0.55), biopsy procedure duration (p = 0.30), pneumothorax (p = 0.61), pulmonary hemorrhage (p = 0.29), or complications requiring a chest tube (p = 0.48). Low-dose CT patients obtained a DLP that was 91% lower than those in the standard-dose CT group (p = 0.01). According to Egger's test, there is a significant possibility of publication bias in DLP (p = 0.034).
CONCLUSIONS
The diagnostic and safety results of low-dose CT-driven PN biopsy are equivalent to those of the standard one, although patients are much less exposed to radiation.
PubMed: 38239580
DOI: 10.5114/wiitm.2023.131563 -
Radiation Oncology (London, England) Jan 2024SBRT is an effective local treatment for patients with early-stage non-small cell lung cancer (NSCLC). This treatment is currently used in patients who have poor lung... (Review)
Review
SBRT is an effective local treatment for patients with early-stage non-small cell lung cancer (NSCLC). This treatment is currently used in patients who have poor lung function or who decline surgery. As SBRT usually has small PTV margins, reducing the beam-on-time (BOT) is beneficial for accurate dose delivery by minimising intrafraction motion as well as improved patient comfort. Removal of the linear accelerator flattening filter can provide a higher dose rate which results in a faster treatment. In addition, the choice of photon energy can also affect the dose distribution to the target and the organs-at-risk (OAR). In this systematic review, studies analysing the choice of various photon beam energies, with a flattening filter or flattening filter free (FFF), were compared for their overall dosimetric benefit in the SBRT treatment for early-stage NSCLC. It was found that FFF treatment delivers a comparatively more conformal dose distribution, as well as a better homogeneity index and conformity index, and typically reduces BOT by between 30 and 50%. The trade-off may be a minor increase in monitor units for FFF treatment found in some studies but not others. Target conformity and OAR sparing, particularly lung doses appear better with 6MV FFF, but 10MV FFF was marginally more advantageous for skin sparing and BOT reduction. The favourable beam modality for clinical use would depend on the individual case, for which tumour size and depth, radiotherapy technique, as well as fractionation scheme need to be taken into account.
Topics: Humans; Radiosurgery; Carcinoma, Non-Small-Cell Lung; Lung Neoplasms; Radiotherapy, Intensity-Modulated; Radiotherapy Planning, Computer-Assisted; Lung; Small Cell Lung Carcinoma; Radiotherapy Dosage
PubMed: 38167095
DOI: 10.1186/s13014-023-02392-4