Sleep Advances : a Journal of the Sleep... 2024A high prevalence of sleep apnea has been reported among transcatheter aortic valve replacement (AVR) patients; however, the prevalence of sleep apnea in the younger and...
STUDY OBJECTIVES
A high prevalence of sleep apnea has been reported among transcatheter aortic valve replacement (AVR) patients; however, the prevalence of sleep apnea in the younger and relatively healthier population of surgical AVR (SAVR) patients is unknown.
METHODS
We assessed the prevalence of sleep apnea and overall sleep quality in patients having SAVR. Participants aged 50-89 were eligible for recruitment. All participants completed type II HST before SAVR. Sleep apnea was defined as an apnea-hypopnea index (AHI) ≥ 5 events/hour. The current use of positive airway pressure was exclusionary.
RESULTS
The 46 participants (32 males/14 females) had a mean age of 66.6 years, body mass index of 30, AHI of 23.5, and obstructive AHI of 22.0. Only four participants had a prior sleep apnea diagnosis, yet all but one had sleep apnea on type II sleep testing. Two-thirds of sleep apnea was moderate or severe (AHI ≥ 15). A quarter of respiratory events were defined by arousals without desaturations. Whereas most sleep parameters resembled those of similarly aged community cohorts, mean percentage of N3 was reduced, accounting for only 3.8% of total sleep time.
CONCLUSIONS
Type II home sleep testing (HST) revealed a 97.8% prevalence of sleep apnea in this sample, most of which was undiagnosed obstructive sleep apnea. Roughly two-thirds of sleep apnea was moderate or severe. Such a high impact of obstructive sleep apnea among patients with severe aortic valve disease deserves further investigation on potential underlying mechanisms and clinical implications.
PubMed: 38947231
DOI: 10.1093/sleepadvances/zpae034 -
Cureus Jun 2024Severe aortic stenosis (AS) significantly elevates cardiovascular risk, predisposing patients to high-degree atrioventricular (AV) block and life-threatening...
Severe aortic stenosis (AS) significantly elevates cardiovascular risk, predisposing patients to high-degree atrioventricular (AV) block and life-threatening tachyarrhythmias, including torsades de pointes (TdP). This case report presents a patient with severe AS who developed high-degree AV block and, subsequently, TdP, highlighting the interplay between bradycardia and mechanisms that trigger ventricular tachycardias. The case underscores the importance of identifying and managing these risk factors to improve patient outcomes.
PubMed: 38947138
DOI: 10.7759/cureus.63315 -
Circulation. Cardiovascular... Jul 2024
PubMed: 38946556
DOI: 10.1161/CIRCINTERVENTIONS.124.014276 -
Echo Research and Practice Jul 2024Aortic stenosis (AS) is the most common degenerative valve disease in high income countries. While hemodynamic metrics are commonly used to assess severity of stenosis,...
BACKGROUND
Aortic stenosis (AS) is the most common degenerative valve disease in high income countries. While hemodynamic metrics are commonly used to assess severity of stenosis, they are impacted by loading conditions and stroke volume and are often discordant. Anatomic valve assessments such as aortic valve calcification (AVC) and valve motion (VM) during transthoracic echocardiography (TTE) can offer clues to disease severity. The reliability of these semi-quantitatively assessed anatomic imaging parameters is unknown.
METHODS
This is a retrospective study of semi-quantitative assessment of AVC and valve VM on TTE. TTEs representing a range of AS severities were identified. The degree of calcification of the aortic valve and the degree of restricted VM were assessed in standard fashion. AVC scores and valve motion were assessed by readers with varied training levels blinded to the severity of AS. Correlation and inter-reader reliability between readers were assessed.
RESULTS
420 assessments (210 each for AVC and VM) were collected for 35 TTEs. Correlation of AVC for imaging trainees (fellows and students, respectively), ranged from 0.49 (95% CI 0.18-0.70) to 0.62 (95% CI 0.36-0.79) and 0.58 (95% CI 0.30-0.76) to 0.54 (95% CI 0.25-0.74) for VM. Correlation of anatomic assessments between echocardiographer-assigned AVC grades was r = 0.76 (95% CI 0.57-0.87)). The correlation between echocardiographer-assigned assessment of VM was r = 0.73 (95% CI 0.53-0.86), p < 0.00001 for both. For echocardiographer AVC assessment, weighted kappa was 0.52 (0.32-0.72), valve motion weighted kappa was 0.60 (0.42-0.78).
CONCLUSION
There was good inter-reader correlation between TTE-based semi-quantitative assessment of AVC and VM when assessed by board certified echocardiographers. There was modest inter-reader reliability of semi-quantitative assessments of AVC and VM between board certified echocardiographers. Inter-reader correlation and reliability between imaging trainees was lower. More reliable methods to assess TTE based anatomic assessments are needed in order to accurately track disease progression.
CLINICAL TRIAL NUMBER
STUDY00003100.
PubMed: 38946008
DOI: 10.1186/s44156-024-00050-3 -
Clinical Nutrition ESPEN Jun 2024Accurate diagnosis of sarcopenia requires evaluation of muscle quality, which refers to the amount of fat infiltration in muscle tissue. In this study, we aim to...
Low muscle quality on a procedural computed tomography scan assessed with deep learning as a practical useful predictor of mortality in patients with severe aortic valve stenosis.
BACKGROUND & AIMS
Accurate diagnosis of sarcopenia requires evaluation of muscle quality, which refers to the amount of fat infiltration in muscle tissue. In this study, we aim to investigate whether we can independently predict mortality risk in transcatheter aortic valve implantation (TAVI) patients, using automatic deep learning algorithms to assess muscle quality on procedural computed tomography (CT) scans.
METHODS
This study included 1199 patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) between January 2010 and January 2020. A procedural CT scan was performed as part of the preprocedural-TAVI evaluation, and the scans were analyzed using deep-learning-based software to automatically determine skeletal muscle density (SMD) and intermuscular adipose tissue (IMAT). The association of SMD and IMAT with all-cause mortality was analyzed using a Cox regression model, adjusted for other known mortality predictors, including muscle mass.
RESULTS
The mean age of the participants was 80 ± 7 years, 53% were female. The median observation time was 1084 days, and the overall mortality rate was 39%. We found that the lowest tertile of muscle quality, as determined by SMD, was associated with an increased risk of mortality (HR 1.40 [95%CI: 1.15-1.70], p < 0.01). Similarly, low muscle quality as defined by high IMAT in the lowest tertile was also associated with increased mortality risk (HR 1.24 [95%CI: 1.01-1.52], p = 0.04).
CONCLUSIONS
Our findings suggest that deep learning-assessed low muscle quality, as indicated by fat infiltration in muscle tissue, is a practical, useful and independent predictor of mortality after TAVI.
PubMed: 38944828
DOI: 10.1016/j.clnesp.2024.06.013 -
Cardiovascular Revascularization... Jun 2024Although the impact of predicted prosthesis-patient mismatch (PPM) on outcomes after surgical aortic valve replacement is well established, studies on PPM in...
BACKGROUND/PURPOSE
Although the impact of predicted prosthesis-patient mismatch (PPM) on outcomes after surgical aortic valve replacement is well established, studies on PPM in transcatheter aortic valve replacement (TAVR) are limited. This study investigated the effects of PPM on haemodynamic and 5-year clinical outcomes after TAVR.
METHODS/MATERIALS
We analysed 1733 patients who underwent TAVR. PPM was defined using two different methods: 1) normal reference values of the effective orifice area for each valve type and size indexed to body surface area (PPM; n = 1733) and 2) reference values for aortic annulus area or perimeter assessed with pre-procedural computed tomography indexed to body surface area (PPM; n = 1227). The primary endpoint was the composite of all-cause death and/or rehospitalisation for heart failure at 5 years.
RESULTS
The incidence of PPM was 11.7 % and 0.8 % in moderate and severe cases, respectively. PPM was classified as either moderate (3.8 %) or severe (0 %). Rates of residual mean aortic gradient ≥20 mmHg significantly increased depending on PPM severity (no PPM: 3.1 % vs. moderate PPM: 26.8 % vs. severe PPM: 53.9 %, p < 0.0001) and PPM (no PPM: 4.1 % vs. moderate PPM: 12.8 %, p = 0.0049). Neither of PPM methods were associated with the composite outcome in total cohort; however, PPM was significantly related to worse clinical outcomes at 5 years among patients with reduced left ventricular ejection fraction (LVEF) in multivariate analysis (HR: 1.87; 95 % CI: 1.02-3.43).
CONCLUSIONS
The impact of PPM on TAVR clinical outcomes may not be negligible in patients with low LVEF.
PubMed: 38944598
DOI: 10.1016/j.carrev.2024.06.011 -
Interdisciplinary Cardiovascular and... Jun 2024The healthcare registries in Denmark present a unique opportunity to gain novel insights into the outcomes associated with both transcatheter and surgical approaches to...
Severe aortic stenosis treated with transcatheter aortic valve implantation or surgical aortic valve replacement with perimount in Western Denmark 2016-2022: a nationwide retrospective study.
OBJECTIVES
The healthcare registries in Denmark present a unique opportunity to gain novel insights into the outcomes associated with both transcatheter and surgical approaches to aortic valve replacement. Our objective is to enhance shared decision-making by comparing long-term mortality and clinical outcomes between treatments.
METHODS
This observational study included all patients with severe aortic stenosis undergoing elective isolated transfemoral transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR) in Western Denmark between January 2016 and April 2022. Patient population and clinical data were identified from the Western Danish Heart Registry and the National Danish Patient Registry, respectively. A propensity score-matched population was generated. Outcomes were investigated according to Valve Academic Research Consortium-3.
RESULTS
A total of 2269 TAVI patients and 1094 SAVR patients where identified. The propensity score-matched population consisted of 468 TAVI patients (mean[SD]age, 75.0[5.3] years) and 468 SAVR patients (mean[SD] age, 75.1[4.6]years). The Kaplan-Meier estimate for the 5-year all-cause mortality was 29.8% in the TAVI group and 16.9% for in the SAVR group (p = 0.019). The risk of all stroke or transient ischaemic attack after five year was 15.1% in the TAVI group and 11.0% in the SAVR group (p = 0.047).
CONCLUSIONS
This study underscores the importance of evaluating all patient factors when choosing an aortic valve replacement method. Surgical aortic valve replacement was a viable choice, especially for patients with New-York Heart Association class I/II, ≥75 age, left ventricular ejection fraction ≥50%, or longer life expectancy.
PubMed: 38944031
DOI: 10.1093/icvts/ivae122 -
Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation.Clinical Hemorheology and... Jun 2024Data on the effect of transcatheter aortic valve implantation (TAVI) on peripheral microcirculation are limited.
BACKGROUND
Data on the effect of transcatheter aortic valve implantation (TAVI) on peripheral microcirculation are limited.
OBJECTIVE
The aim of this study is to evaluate peripheral microvascular tissue saturation (StO2) before and after TAVI in relation to central and peripheral hemodynamics, cardiac and renal function.
METHODS
In this single-center prospective study, patients with severe aortic stenosis (sAS) scheduled for TAVI or cardiac catheterization (control) were assessed before and up to five days after the procedure. Cardiac function including cardiac output (CO) was assessed by echocardiography. Brachial (bBP) and central blood pressure (cBP), ankle brachial index (ABI), and parameters of arterial stiffness, including augmentation pressure (AP) and augmentation index adjusted for heart rate (AIx@HR75) were measured to assess hemodynamic changes. StO2 was measured in all extremities using a near-infrared spectroscopy (NIRS) camera. Renal function was measured by creatinine levels.
RESULTS
26 patients underwent TAVI and 11 patients served as control. Cardiac output was significantly increased, whereas hemodynamic parameters and peripheral StO2 were significantly decreased after TAVI. At follow-up, StO2 returned to baseline values. Changes in StO2 were negatively related to creatinine levels.
CONCLUSION
Transcatheter aortic valve implantation causes a temporary decrease in microvascular tissue saturation that is associated with renal function.
PubMed: 38943384
DOI: 10.3233/CH-232051 -
Scientific Reports Jun 2024Subclinical leaflet thrombosis (SLT) can be one of the causes of transcatheter heart valve (THV) failure after transcatheter aortic valve implantation (TAVI). We sought...
Subclinical leaflet thrombosis (SLT) can be one of the causes of transcatheter heart valve (THV) failure after transcatheter aortic valve implantation (TAVI). We sought to clarify the formation process of SLT and thrombogenicity during the perioperative period of TAVI. This multicenter, prospective, single-arm interventional study enrolled 26 patients treated with edoxaban for atrial fibrillation and who underwent TAVI for severe aortic stenosis between September 2018 and September 2022. We investigated changes in maximal leaflet thickness detected by contrast-enhanced computed tomography between 1 week and 3 months after TAVI in 18 patients and measured the thrombogenicity by Total Thrombus-formation Analysis System (T-TAS) and flow stagnation volume by computational fluid dynamics (CFD) (n = 11). SLT was observed in 16.7% (3/18) at 1 week, but decreased to 5.9% (1/17) at 3 months after TAVI. Patients with SLT at 1 week had a significantly decreased maximal leaflet thickness compared to those without SLT. Thrombogenicity assessed by T-TAS decreased markedly at 1 week and tended to increase at 3 months. The stagnation volume assessed by CFD was positively associated with a higher maximum leaflet thickness. This study showed the course of leaflet thrombus formation and visualization of stagnation in neo-sinus of THV in the acute phase after TAVI.
Topics: Humans; Aortic Valve Stenosis; Transcatheter Aortic Valve Replacement; Atrial Fibrillation; Thrombosis; Female; Male; Aged, 80 and over; Aged; Prospective Studies; Aortic Valve; Severity of Illness Index; Pyridines; Thiazoles
PubMed: 38942790
DOI: 10.1038/s41598-024-65600-5 -
Korean Journal of Radiology Jul 2024This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in...
OBJECTIVE
This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function.
MATERIALS AND METHODS
A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed.
RESULTS
Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR ( < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration.
CONCLUSION
Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.
Topics: Humans; Male; Female; Contrast Media; Aged, 80 and over; Transcatheter Aortic Valve Replacement; Tomography, X-Ray Computed; Aged; Acute Kidney Injury; Aortic Valve Stenosis; Radiography, Dual-Energy Scanned Projection; Radiation Dosage; Reproducibility of Results; Renal Insufficiency; Retrospective Studies; Signal-To-Noise Ratio
PubMed: 38942457
DOI: 10.3348/kjr.2023.1207