-
Resuscitation Jun 2024
PubMed: 38942267
DOI: 10.1016/j.resuscitation.2024.110296 -
JACC. Advances Jan 2024Multilevel obstruction in left ventricular inflow and outflow predisposes to arrhythmias in Shone's complex (SC).
BACKGROUND
Multilevel obstruction in left ventricular inflow and outflow predisposes to arrhythmias in Shone's complex (SC).
OBJECTIVES
The purpose of this study was to study the prevalence and outcomes (heart failure [HF] hospitalization, cardiac transplant, death) of cardiac arrhythmias in adults with SC.
METHODS
Adults with SC (defined as ≥2 lesions out of supramitral ring, parachute mitral valve, subvalvular/valvular aortic stenosis (AS), and aortic coarctation) seen at Mayo Clinic between January 1999 and March 2020 were identified and evaluated for the presence of sustained atrial fibrillation, atrial flutter, and ventricular arrhythmias (VA). Kaplan-Meier survival analysis was used to calculate the occurrence of these arrhythmias.
RESULTS
Seventy-three patients with SC (mean age at first visit 33 ± 13 years) were identified. Most common anomalies were valvular AS (88%), coarctation (85%), parachute mitral valve (44%), subvalvular AS (44%), and supramitral ring (25%). Atrial arrhythmias were diagnosed in 24 patients (33%) at a mean age of 34.6 ± 12.7 years. Patients with atrial fibrillation and atrial flutter had higher number of surgeries, left atrial size, right ventricular systolic pressure, and HF hospitalizations. A rhythm control approach was used in majority of patients (75% on antiarrhythmic drugs and 50% underwent catheter ablation). Sustained VA occurred in 6 of 73 patients of whom 4 had an ejection fraction <40%. Death and cardiac transplantation occurred in 11 and 3 patients, respectively, during a median follow-up of 7.3 ± 6.0 years.
CONCLUSIONS
In adults with SC, atrial arrhythmias occurred in one-third of patients, were associated with more HF hospitalizations, and frequently required rhythm control. Prevalence of sustained VA was 8% and implantable cardioverter-defibrillator implantation should be considered in those with reduced ejection fraction.
PubMed: 38939811
DOI: 10.1016/j.jacadv.2023.100715 -
Journal of Arrhythmia Jun 2024We explored the results of two tests of the novel HeartInsight algorithm for heart failure (HF) prediction, reconstructing trends from historical cases. Results suggest...
We explored the results of two tests of the novel HeartInsight algorithm for heart failure (HF) prediction, reconstructing trends from historical cases. Results suggest potential extension of HeartInsight to implantable cardioverter defibrillators patients without history of HF and illustrate the importance of the baseline clinical profile in enhancing algorithm specificity.
PubMed: 38939800
DOI: 10.1002/joa3.13032 -
Journal of Arrhythmia Jun 2024Implantable cardioverter-defibrillator (ICD) offers an opportunity to study inducibility of ventricular tachycardia (VT) or ventricular fibrillation (VF) by performing...
BACKGROUND
Implantable cardioverter-defibrillator (ICD) offers an opportunity to study inducibility of ventricular tachycardia (VT) or ventricular fibrillation (VF) by performing noninvasive programmed ventricular stimulation (NIPS). Whether NIPS can predict future arrhythmic events or mortality in patients with primary prevention ICD, has not yet been examined.
METHODS
From the NIPS-ICD study (ClinicalTrials ID: NCT02373306) 41 consecutive patients (34 males, age 64 ± 11 years, 76% ischemic cardiomyopathy [ICM]) had ICD for primary prevention indication. Patients underwent NIPS using a standardized protocol of up to three premature extrastimuli at 600, 500 and 400 ms drive cycle lengths. NIPS was classified as positive if sustained VT or VF was induced. The study endpoint was occurrence of sustained VT/VF during the follow-up.
RESULTS
At baseline NIPS, VT/VF was induced in 8 (20%) ICM patients. During the 5-year follow-up, the VT/VF occurred in 7 (17%) patients, all with ICM. The difference between NIPS-inducible versus NIPS-noninducible patients regarding VT/VF occurrence did not meet statistical significance (38% vs. 12%, log rank test = .11). After a 5-year follow-up, the mortality rate was significantly higher in patients who had VT/VF induced at NIPS versus no VT/VF at NIPS (38% vs. 12%, = .043). The occurrence of a composite endpoint consisting of VT/VF recurrence or death in patients with ICM was also most frequent in the NIPS-inducible group (75% vs. 35%, = .037).
CONCLUSIONS
Inducibility of VT/VF during NIPS in ICM patients with primary prevention ICD is associated with higher mortality and higher incidence of composite endpoint consisting of death or VT/VF during a long-term observation.
PubMed: 38939799
DOI: 10.1002/joa3.13017 -
Journal of Arrhythmia Jun 2024We report the behavior of OptiVol2 fluid index (OVFI2) and intrathoracic impedance on remote monitoring before the appearance of signs of infection. A sustained rise in...
We report the behavior of OptiVol2 fluid index (OVFI2) and intrathoracic impedance on remote monitoring before the appearance of signs of infection. A sustained rise in OVFI2 early after implantation reflects peri-device fluid retention.
PubMed: 38939798
DOI: 10.1002/joa3.13005 -
Journal of Arrhythmia Jun 2024Guidelines recommended remote monitoring (RM) in managing patients with Cardiac Implantable Electronic Devices. In recent years, smart device (phone or tablet)...
BACKGROUND
Guidelines recommended remote monitoring (RM) in managing patients with Cardiac Implantable Electronic Devices. In recent years, smart device (phone or tablet) monitoring-based RM (SM-RM) was introduced. This study aims to systematically review SM-RM versus bedside monitor RM (BM-RM) using radiofrequency in terms of compliance, connectivity, and episode transmission time.
METHODS
We conducted a systematic review, searching three international databases from inception until July 2023 for studies comparing SM-RM (intervention group) versus BM-RM (control group).
RESULTS
Two matched studies (21 978 patients) were retrieved (SM-RM arm: 9642 patients, BM-RM arm: 12 336 patients). There is significantly higher compliance among SM-RM patients compared with BM-RM patients in both pacemaker and defibrillator patients. Manyam et al. found that more SM-RM patients than BM-RM patients transmitted at least once (98.1% vs. 94.3%, < .001), and Tarakji et al. showed that SM-RM patients have higher success rates of scheduled transmissions than traditional BM-RM methods (SM-RM: 94.6%, pacemaker manual: 56.3%, pacemaker wireless: 77.0%, defibrillator wireless: 87.1%). There were higher enrolment rates, completed scheduled and patient-initiated transmissions, shorter episode transmission time, and higher connectivity among SM-RM patients compared to BM-RM patients. Younger patients (aged <75) had more patient-initiated transmissions, and a higher proportion had ≥10 transmissions compared with older patients (aged ≥75) in both SM-RM and BM-RM groups.
CONCLUSION
SM-RM is a step in the right direction, with good compliance, connectivity, and shorter episode transmission time, empowering patients to be in control of their health. Further research on cost-effectiveness and long-term clinical outcomes can be carried out.
PubMed: 38939794
DOI: 10.1002/joa3.13054 -
Journal of Arrhythmia Jun 2024Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often...
Multicenter prospective observational study to clarify the current status and clinical outcome in Japanese patients who have an indication for implantable cardioverter defibrillator (ICD) or wearable cardioverter defibrillator (WCD) (TRANSITION JAPAN-ICD/WCD study): Rationale and design of a...
BACKGROUND
Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often withheld especially in Japanese heart failure patients with reduced left ventricular ejection fraction (HFrEF) who have not experienced ventricular tachycardia (VT) or ventricular fibrillation (VF) for uncertain reasons. Recent advancements in heart failure (HF) medications have significantly improved the prognosis for HFrEF. Given this context, a critical reassessment of the treatment and prognosis of ICDs and WCDs is essential, as it has the potential to reshape awareness and treatment strategies for these patients.
METHODS
We are initiating a prospective multicenter observational study for HFrEF patients eligible for ICD in primary and secondary prevention, and WCD, regardless of device use, including all consenting patients. Study subjects are to be enrolled from 31 participant hospitals located throughout Japan from April 1, 2023, to December 31, 2024, and each will be followed up for 1 year or more. The planned sample size is 651 cases. The primary endpoint is the rate of cardiac implantable electronic device implementation. Other endpoints include the incidence of VT/VF and sudden death, all-cause mortality, and HF hospitalization, other events. We will collect clinical background information plus each patient's symptoms, Clinical Frailty Scale score, laboratory test results, echocardiographic and electrocardiographic parameters, and serial changes will also be secondary endpoints.
RESULTS
Not applicable.
CONCLUSION
This study offers invaluable insights into understanding the role of ICD/WCD in Japanese HF patients in the new era of HF medication.
PubMed: 38939793
DOI: 10.1002/joa3.13028 -
Journal of Arrhythmia Jun 2024A 26-year-old man with long QT syndrome (LQTS) underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. The patient exhibited sinus...
A 26-year-old man with long QT syndrome (LQTS) underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. The patient exhibited sinus bradycardia relative to his age. The heart rate decreased, and the QT interval became longer with the administration of β-blockers, the first-line therapy for LQTS. The patient experienced frequent S-ICD discharges. Subsequently, a single-chamber pacemaker was implanted, and the 12-lead electrocardiogram showed atrial pacing and ventricular sensing at 60 beats per minute with a shorter QTc interval. After converting to "double-device therapy," the patient did not experience any ventricular arrhythmia events.
PubMed: 38939789
DOI: 10.1002/joa3.13027 -
JACC. Advances Sep 2023
PubMed: 38939490
DOI: 10.1016/j.jacadv.2023.100561 -
Cureus May 2024Chagas disease (CD), caused by is a leading cause of cardiomyopathy in Latin America that can lead to heart failure, arrhythmias, and sudden cardiac death (SCD). We...
Chagas disease (CD), caused by is a leading cause of cardiomyopathy in Latin America that can lead to heart failure, arrhythmias, and sudden cardiac death (SCD). We present a case of a 71-year-old female from El Salvador with symptomatic ventricular tachycardia (VT) requiring emergent cardioversion and implantable cardioverter-defibrillator (ICD) due to CD. Diagnostic evaluation is limited and unclear in cases of chronic disease. Treatment involves antiparasitic therapy, heart failure management, and arrhythmia prevention. With growing numbers of cases in the US and limited treatment options, we highlight the need for timely recognition and intervention to reduce the burden of CD.
PubMed: 38939252
DOI: 10.7759/cureus.61189