Biomolecules Jun 2024Osteoblastic responses play a crucial role in the success of oral implants. Enhanced proliferation of osteoblast cells is associated with reduced cell mortality and an... (Comparative Study)
Comparative Study
INTRODUCTION
Osteoblastic responses play a crucial role in the success of oral implants. Enhanced proliferation of osteoblast cells is associated with reduced cell mortality and an increase in bone regeneration. This study aims to evaluate the osteoblastic responses following oral implantation.
MATERIALS AND METHODS
Osteoblast stem cells were harvested and subsequently cultivated using cell culture techniques. The osteoblastic phenotype of the extracted cells was confirmed by examining the extracellular matrix. Cell morphogenesis on functionalized biomaterial surfaces was assessed through indirect immunofluorescence staining. The cellular response was investigated in the presence of two types of implant materials: titanium (Ti) and alumina-toughened zirconia (ATZ). Cell viability and apoptosis were quantitatively assessed using MTT assays and flow cytometry, respectively.
RESULTS
The survival of osteoblastic lineage cells was moderately reduced post-implantation. Viability in the Ti implant group remained at approximately 86%, while in the ATZ group, it was observed at 75%, which is considered acceptable. Moreover, there was a significant disparity in cell survival between the two implant groups ( < 0.05). Analysis of apoptosis levels at various concentrations revealed that the rate of apoptosis was 3.6% in the control group and 18.5% in the ATZ group, indicating that apoptosis or programmed cell death in the ATZ-treated group had increased nearly four-fold ( < 0.05).
CONCLUSIONS
The findings of this study indicate a reduction in osteoblastic cell line survival following implant treatment, with titanium implants exhibiting superior performance in terms of cell survival. However, it was also noted that the incidence of apoptosis in osteoblast cells was significantly higher in the presence of zirconium-based implants.
Topics: Zirconium; Titanium; Osteoblasts; Aluminum Oxide; Cell Survival; Apoptosis; Animals; Dental Implants; Humans; Cell Proliferation; Cells, Cultured; Surface Properties
PubMed: 38927122
DOI: 10.3390/biom14060719 -
Journal of Prosthodontic Research Jun 2024This study aimed to evaluate the 10-year outcomes of partial fixed dental prostheses (P-FDPs) fabricated using metal-free fiber-reinforced composite (FRC) resin...
PURPOSE
This study aimed to evaluate the 10-year outcomes of partial fixed dental prostheses (P-FDPs) fabricated using metal-free fiber-reinforced composite (FRC) resin frameworks veneered with composite resin and supported by short and extra-short implants.
METHODS
This study included 28 patients with 38 FRC prostheses supported by 96 implants. Implant and prosthesis survival and success rates were evaluated using Kaplan-Meier analysis.
RESULTS
The 10-year implant survival and success rate, as determined by Kaplan-Meier analysis, was 96.9%, and the prosthesis survival and success rates were 94.7% and 92.0%, respectively. None of the parameters under investigation were significantly correlated with prosthetic survival or successful outcomes, but three parameters were correlated with higher peri-implant bone levels: implant placement in the mandible as opposed to the maxilla, shorter P-FDP spans, and natural teeth on the opposing arch.
CONCLUSIONS
FRC P-FDPs supported by short and extra-short implants presented high, up to 10-year, survival and success rates, when used to restore partially edentulous arches.
PubMed: 38925987
DOI: 10.2186/jpr.JPR_D_23_00005 -
Journal of Prosthodontic Research Jun 2024Occlusal overload can cause late implant loss. However, whether the magnitude of the occlusal force is a risk factor for late implant loss remains unclear. Thus, this...
PURPOSE
Occlusal overload can cause late implant loss. However, whether the magnitude of the occlusal force is a risk factor for late implant loss remains unclear. Thus, this clinical study aimed to determine the relationship between the gonial angle (GoA), which is associated with the magnitude of occlusal force, and late implant loss.
METHODS
All implants with fixed prostheses placed at the Niigata University Hospital between April 2006 and August 2019 were included in this retrospective study. The implants with and without late loss were compared. Relevant variables, including smoking habits, diabetes mellitus status, remaining dentition, implant length and diameter, prosthesis design, retention systems, splinting, and GoA were assessed. Log-rank test and Cox proportional hazards regression analysis were used to estimate the adjusted hazard ratio (aHR) and to calculate the corresponding 95% confidence intervals (CI) for late implant loss.
RESULTS
A total of 919 patients (349 men and 570 women) with 2512 implants were included in this study. Cox proportional hazards regression analysis revealed that a 10° decrease in the GoA (aHR, 1.588; 95% CI, 1.115-1.766; P = 0.010), smoking habits (aHR, 3.909; 95% CI, 2.131-7.168; P < 0.001), and male sex (aHR, 2.584; 95% CI, 1.376-4.850; P = 0.003) were significantly associated with late implant loss.
CONCLUSIONS
Within the limitations of this retrospective study of 2512 implants, smaller GoA, smoking habits, and male sex were risk factors for late implant loss.
PubMed: 38925984
DOI: 10.2186/jpr.JPR_D_23_00267 -
BMJ Case Reports Jun 2024Soft tissue deficiency in a tooth extraction site in the aesthetic area is a common and challenging clinical situation. This case report demonstrates the successful...
Soft tissue deficiency in a tooth extraction site in the aesthetic area is a common and challenging clinical situation. This case report demonstrates the successful treatment of extensive gingival recession and buccal bone dehiscence associated with a hopeless tooth. Initially, a connective tissue graft was used to cover the root and thicken the soft tissue. After 2 months, the tooth was extracted, an implant was immediately placed, and a temporary restoration was installed. After 3 months, the soft tissue exhibited a natural and harmonious architecture. A custom zirconia abutment and crown were then fabricated and placed. At the 4-year follow-up, the peri-implant tissue displayed satisfactory aesthetics, with a well-structured buccal bone plate and healthy peri-implant indicators. This two-stage approach, addressing gingival recession first and proceeding with immediate implant placement after soft tissue healing, proved to be a safe and effective method with stable long-term results.
Topics: Humans; Gingival Recession; Esthetics, Dental; Female; Follow-Up Studies; Crowns; Immediate Dental Implant Loading; Tooth Extraction; Male; Dental Implants, Single-Tooth; Adult; Connective Tissue; Treatment Outcome; Middle Aged
PubMed: 38925675
DOI: 10.1136/bcr-2023-259271 -
Brazilian Dental Journal 2024Rehabilitation of edentulous atrophic mandibles involves the placement of implants in the anterior segment of the mandible. The primary stability of these implants can...
Rehabilitation of edentulous atrophic mandibles involves the placement of implants in the anterior segment of the mandible. The primary stability of these implants can be improved using the base of the mandible as complementary anchorage (bicorticalization). This study aimed to analyze the biomechanics of atrophic mandibles rehabilitated with monocortical or bicortical implants. Two three-dimensional virtual models of edentulous mandibles with severe atrophy were prepared. Four monocortical implants were placed in one model (McMM), and four bicortical implants were placed in the other (BcMM). An implant-supported total prosthesis was prepared for each model. Then, a total axial load of 600 N was applied to the posterior teeth, and its effects on the models were analyzed using finite element analysis. The highest compressive stresses were concentrated in the cervical region of the implants in the McMM (-32.562 Mpa); in the BcMM, compressive stresses were distributed in the upper and lower cortex of the mandible, with increased compressive stresses at the distal implants (-63.792 Mpa). Thus, we conclude that axial loading forces are more uniformly distributed in the peri-implant bone when using monocortical implants and concentrated in the apical and cervical regions of the peri-implant bone when using bicortical implants.
Topics: Humans; Mandible; Dental Implants; Finite Element Analysis; Atrophy; Dental Prosthesis, Implant-Supported; Jaw, Edentulous; Biomechanical Phenomena; Dental Stress Analysis
PubMed: 38922249
DOI: 10.1590/0103-6440202405621 -
CoDAS 2024To investigate the association between the number of permanent teeth and the use of removable dental prostheses with self-reported dysphagia occurrence in individuals...
PURPOSE
To investigate the association between the number of permanent teeth and the use of removable dental prostheses with self-reported dysphagia occurrence in individuals aged 60 years or older.
METHODS
A population-based cross-sectional study was conducted with 5,432 old individuals who participated in the baseline of the Brazilian Longitudinal Study of Elderly Health (ELSI-Brazil). The outcome "dysphagia" was associated with the number of permanent teeth and the use of removable dental prostheses. Sociodemographic independent variables (age, sex, and race/ethnicity) and clinical history variables (no morbidity, one morbidity, or more than two morbidities) were analyzed using Poisson Regression with robust variance and their respective 95% confidence intervals (CI).
RESULTS
The prevalence of self-reported dysphagia in non-institutionalized old individuals was 30%. The group of old individuals with 10 - 19 natural teeth showed a 52% increased risk of self-reported dysphagia complaint (PRadj 1,565 IC95% 1,34;1,826) compared to their counterparts with more teeth.
CONCLUSION
An association was found between a lower number of teeth and removable prostheses with the occurrence of dysphagia.
Topics: Humans; Brazil; Female; Male; Deglutition Disorders; Cross-Sectional Studies; Self Report; Aged; Middle Aged; Prevalence; Dental Prosthesis; Longitudinal Studies; Aged, 80 and over; Risk Factors; Socioeconomic Factors; Tooth Loss
PubMed: 38922245
DOI: 10.1590/2317-1782/20242023072pt -
Journal of Applied Oral Science :... 2024to evaluate the morphological and functional characteristics of the peri-implant bone tissue that was formed during the healing process by the placement implants using...
OBJECTIVES
to evaluate the morphological and functional characteristics of the peri-implant bone tissue that was formed during the healing process by the placement implants using two different surface treatments: hydrophilic Acqua™ (ACQ) and rough NeoPoros™ (NEO), in spontaneously hypertensive (SHR) and normotensive rats (Wistar) whether or not treated with losartan.
METHODOLOGY
In total, 96 male rats (48 Wistar and 48 SHR) were divided into eight subgroups: absolute control rough (COA NEO), absolute control hydrophilic (COA ACQ), losartan control rough (COL NEO), losartan control hydrophilic (COL ACQ), SHR absolute rough (SHR NEO), SHR absolute hydrophilic (SHR ACQ), SHR losartan rough (SHRL NEO), and SHR losartan hydrophilic (SHRL ACQ). The rats medicated with losartan received daily doses of the medication. NeoPoros™ and Acqua™ implants were installed in the tibiae of the rats. After 14 and 42 days of the surgery, the fluorochromes calcein and alizarin were injected in the rats. The animals were euthanized 67 days after treatment. The collected samples were analyzed by immunohistochemistry, biomechanics, microcomputerized tomography, and laser confocal scanning microscopy analysis.
RESULTS
The osteocalcin (OC) and vascular endothelium growth factor (VEGF) proteins had moderate expression in the SHRL ACQ subgroup. The same subgroup also had the highest implant removal torque. Regarding microarchitectural characteristics, a greater number of trabeculae was noted in the control animals that were treated with losartan. In the bone mineralization activity, it was observed that the Acqua™ surface triggered higher values of MAR (mineral apposition rate) in the COA, COL, and SHRL groups (p<0.05).
CONCLUSION
the two implant surface types showed similar responses regarding the characteristics of the peri-implant bone tissue, even though the ACQ surface seems to improve the early stages of osseointegration.
Topics: Animals; Losartan; Rats, Inbred SHR; Rats, Wistar; Male; Surface Properties; Dental Implants; Time Factors; X-Ray Microtomography; Reproducibility of Results; Immunohistochemistry; Hydrophobic and Hydrophilic Interactions; Osseointegration; Treatment Outcome; Dental Implantation, Endosseous; Microscopy, Confocal; Tibia; Analysis of Variance; Biomechanical Phenomena; Reference Values; Osteocalcin
PubMed: 38922240
DOI: 10.1590/1678-7757-2023-0374 -
Brazilian Oral Research 2024The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical...
The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography. A significant difference was noted in the ISQ values between t1 and t2 in type III bone for EH and MT implants. No significant difference in bone loss values was observed when comparing bone types for EH or MT in all evaluated sites. Based on marginal bone loss assessed using radiography, there was no significant difference between the MT and EH groups. A positive correlation between torque and ISQ t1 value was observed for MT (correlation: 0.439; p = 0.041) and EH (correlation: 0.461; p = 0.031) implants. For EH and MT implants, the greater the insertion torque, the greater was the ISQ value (moderately positive correlation). A weak negative correlation was found between bone type and ISQ t1 for MT implants. Contrarily, no correlation was observed between bone type and ISQ t1 for EH implants. In all cases, bone loss around the implants was clinically normal.
Topics: Humans; Torque; Male; Female; Alveolar Bone Loss; Osseointegration; Dental Implantation, Endosseous; Middle Aged; Reference Values; Time Factors; Treatment Outcome; Statistics, Nonparametric; Dental Prosthesis Design; Adult; Mandible; Dental Prosthesis Retention; Aged; Resonance Frequency Analysis; Dental Implants; Maxilla; Dental Implants, Single-Tooth; Reproducibility of Results
PubMed: 38922209
DOI: 10.1590/1807-3107bor-2024.vol38.0049 -
Journal of Functional Biomaterials May 2024The progress of digital technologies in dental prosthodontics is fast and increasingly accurate, allowing practitioners to simplify their daily work. These technologies...
The progress of digital technologies in dental prosthodontics is fast and increasingly accurate, allowing practitioners to simplify their daily work. These technologies aim to substitute conventional techniques progressively, but their real efficiency and predictability are still under debate. Many systematic reviews emphasize the lack of clinical RCTs that compare digital and traditional workflow. To address this evidence, we conducted a three-arm designed clinical RCT, which compares fully digital, combined digital, and analogic and fully analog workflows. We aimed to compare the clinical properties of each workflow regarding interproximal (IC) and occlusal contact (OC), marginal fit, impression time (IT), and patient satisfaction through a VAS scale. In total, 72 patients were included in the study. The IC and OC of the digital workflow were better than the others ( < 0.001), which obtained similar results. No difference between implant-abutment fit was observed ( = 0.5966). The IT was shorter in the digital workflow than the others ( < 0.001), which were similar. Patient satisfaction was higher in the digital workflow than in the conventional one. Despite the limitations, this study's results support better accuracy and patient tolerance of digital workflow than of conventional techniques, suggesting it as a viable alternative to the latter when performed by clinicians experienced in digital dentistry.
PubMed: 38921523
DOI: 10.3390/jfb15060149 -
Dentistry Journal Jun 2024The increase in soft tissue (ST) around implants can benefit peri-implant health and aesthetic results. The objective was to compare the gingival and esthetic health... (Review)
Review
BACKGROUND
The increase in soft tissue (ST) around implants can benefit peri-implant health and aesthetic results. The objective was to compare the gingival and esthetic health benefits of immediate implant placement (IIP) with simultaneous or delayed connective tissue graft (CTG) compared to IIP without CTG.
METHODS
A systematic review was carried out by two reviewers in Medline-Pubmed, Scopus, and Cochrane. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were considered. Randomized Clinical Trials (RCTs) that were published between April 2017 and February 2024 were used. Studies that analyzed the performance of a simultaneous or deferred CTG after the placement of an implant in the aesthetic zone, with or without immediate provisionalization, without previous regeneration, with a follow-up of 6 months, and that were performed in humans were included.
RESULTS
Quantitative analysis was performed using data provided by the RCTs. The five RCTs that were selected analyzed a total "" of 245 subjects who met the inclusion criteria and focused on the subject of the study. In the quantitative analysis, four RCTs were included. The studies evaluated buccal gingiva levels when placing the IIP with and without CTG, obtaining a mean buccal gingiva level difference of 0.09 mm (95% CI: -0.54 to 0.72, = 0.05), statistically not significant, but with a favorable trend.
CONCLUSIONS
The use of CTG associated with the II can maintain the gum level but not increase the volume. CTG is favorable for achieving successful esthetic results when immediate placement of an implant with a provisional prosthesis is planned.
PubMed: 38920885
DOI: 10.3390/dj12060183