Mass Spectrometry Reviews Jun 2024Dental caries, a prevalent global infectious condition affecting over 95% of adults, remains elusive in its precise etiology. Addressing the complex dynamics of caries... (Review)
Review
Dental caries, a prevalent global infectious condition affecting over 95% of adults, remains elusive in its precise etiology. Addressing the complex dynamics of caries demands a thorough exploration of taxonomic, potential, active, and encoded functions within the oral ecosystem. Metabolomic profiling emerges as a crucial tool, offering immediate insights into microecosystem physiology and linking directly to the phenotype. Identified metabolites, indicative of caries status, play a pivotal role in unraveling the metabolic processes underlying the disease. Despite challenges in metabolite variability, the use of metabolomics, particularly via mass spectrometry and nuclear magnetic resonance spectroscopy, holds promise in caries research. This review comprehensively examines metabolomics in caries prevention, diagnosis, and treatment, highlighting distinct metabolite expression patterns and their associations with disease-related bacterial communities. Pioneering in approach, it integrates singular and combinatory metabolomics methodologies, diverse biofluids, and study designs, critically evaluating prior limitations while offering expert insights for future investigations. By synthesizing existing knowledge, this review significantly advances our comprehension of caries, providing a foundation for improved prevention and treatment strategies.
PubMed: 38940512
DOI: 10.1002/mas.21896 -
Photochemistry and Photobiology Jun 2024The purpose of this study was to evaluate the effects of 635 nm diode laser with different powers on undifferentiated mesenchymal stem cells obtained from buccal fat...
The purpose of this study was to evaluate the effects of 635 nm diode laser with different powers on undifferentiated mesenchymal stem cells obtained from buccal fat pad. Human buccal fat stem cells were cultured in DMEM containing 10% FBS, penicillin, and streptomycin under 5% CO and 95% humidity. Cells were cultured in 96-well plate and 24 h later, laser irradiation with 635 nm diode laser was performed in four groups of 200, 300, 400, and 500 mW powers in addition to the control group with the same energy density of 4 J/cm. MTT and flow cytometry assay was performed to evaluate cell proliferation and viability on 2 and 4 days after irradiation. Alizarin red assay and real-time PCR (OPN, OCN, ALP, and RUNX-2 genes) was performed to evaluate osteogenic differentiation. According to the MTT assay, none of the mentioned powers of 635 nm diode laser had significant effect on cell proliferation. Cells irradiated with power of 400 mW and 500 mW significantly showed a greater number of necrotic cells compared to the control group in Day 4. Cells irradiated with 300 mW power significantly exhibited a greater amount of nodule formation compared to all groups. Results of this study indicated that 635 nm diode laser with energy density of 4 J/cm has a positive effect inducing osteogenic differentiation when applying with a power of 300 mW in buccal fat pad mesenchymal stem cells.
PubMed: 38940369
DOI: 10.1111/php.13992 -
The Cochrane Database of Systematic... Jun 2024Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective... (Meta-Analysis)
Meta-Analysis Review
BACKGROUND
Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems.
OBJECTIVES
To assess the effectiveness of PICC material and design in reducing catheter failure and complications.
SEARCH METHODS
The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information.
SELECTION CRITERIA
We included randomised controlled trials (RCTs) evaluating PICC design and materials.
DATA COLLECTION AND ANALYSIS
We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE.
MAIN RESULTS
We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence).
AUTHORS' CONCLUSIONS
There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.
Topics: Humans; Randomized Controlled Trials as Topic; Catheterization, Peripheral; Catheter-Related Infections; Equipment Failure; Equipment Design; Venous Thromboembolism; Catheter Obstruction; Central Venous Catheters; Cause of Death; Bias; Catheterization, Central Venous; Bacteremia
PubMed: 38940297
DOI: 10.1002/14651858.CD013366.pub2 -
Journal of Esthetic and Restorative... Jun 2024The purpose of the study was to investigate the influence of different preparation designs and scan patterns on the accuracy of intraoral scans for complete-arch...
PURPOSE
The purpose of the study was to investigate the influence of different preparation designs and scan patterns on the accuracy of intraoral scans for complete-arch maxillary laminate veneers.
MATERIALS AND METHODS
Three maxillary typodonts were used to obtain reference models with three different laminate veneer preparation designs: windows (W), beveled (B), and incisal overlap (IO). Reference scans were obtained with a desktop scanner. A total of 90 complete arch intraoral scans were made with an intraoral scanner (Medit i700) following three different scan patterns: straight motion (SM), zigzag motion (ZM), and combined motion (CM). Ten scans were made in each subgroup and exported as standard tessellation language (STL) files. Assessment of accuracy was conducted with a 3D software analysis program (Geomagic Control X). Each STL file was individually aligned with the reference scan using the best fit algorithm tool, and 3D differences were calculated using the root mean square (RMS) value. Two-way analysis of variance (ANOVA) followed by post hoc comparison tests were applied to analyze precision and trueness data (α = 0.05).
RESULTS
Two-way ANOVA and post hoc comparison tests revealed significant differences among different preparation designs and scan patterns (p < 0.05). Regarding trueness, the IO when scanned with SM presented higher mean RMS than the other preparation designs (W and B) scanned with the same scanning pattern (p < 0.05). Regarding precision, the groups of W and IO presented significantly higher mean RMS than the group of B when scanned with ZM (p < 0.05).
CONCLUSIONS
Accuracy of intraoral scans for complete-arch laminate veneers was affected by different laminate veneer preparation designs and scan patterns.
CLINICAL SIGNIFICANCE
Modifying scan pattern according to preparation design helps to improve scan accuracy for complete-arch laminate veneers.
PubMed: 38940120
DOI: 10.1111/jerd.13276 -
Annals of Agricultural and... Jun 2024Both periodontitis and non-specific bowel diseases (IBD) are complex chronic diseases, and the elements connecting them are the dysregulated microbiota and abnormal... (Review)
Review
INTRODUCTION AND OBJECTIVE
Both periodontitis and non-specific bowel diseases (IBD) are complex chronic diseases, and the elements connecting them are the dysregulated microbiota and abnormal immune response of the host. In turn, in the etiology of these diseases, the common environmental risk factor is improper mode of nutrition. The aim of the study is to review nutritional interventions and effective nutritional protocols applied in periodontitis and IBD. The result of the review will be identification of dietary recommendations exerting a beneficial effect on the reduction of the risk of development and alleviation of the severity of both diseases. At the same time, non-recommended dietary choices will be indicated.
REVIEW METHODS
A review of literature was carried out using the databases PubMed, Google Scholar, and Web of Science. Publications were analyzed by a non-systematic literature review aimed at making a brief synthesis of the collected information.
BRIEF DESCRIPTION OF THE STATE OF KNOWLEDGE
Diets recommended to patients with both periodontitis and IBD included the Mediterranean diet, DASH diet and vegetarian diet; excluding veganism, raw foodism and fruitarianism. For patients with IBD, special dietary recommendations were elaborated on the recommendations of the International Organization for Research into Inflammatory Bowel Diseases (IOIBD), and specific diets, i.e. specific carbohydrate diet (SCD), and Groningen anti-inflammatory diet (GrAID). In the process of treatment of oral and intestinal dysbiosis, probiotic therapy is beneficial in both diseases, specified as the Western diet. Non-conventional diets are not recommended.
SUMMARY
Diet therapy for inflammatory periodontal diseases and IBD requires extensive individualization; nevertheless, a universal principle is avoidance of highly processed food, and implementation of easily digestible meals based on natural, ecological products. Proper nutrition plays a crucial role in primary prevention of both diseases analyzed, whereas in secondary prevention, diet therapy is a valuable supplementation of pharmacotherapy.
Topics: Humans; Inflammatory Bowel Diseases; Periodontitis; Diet; Secondary Prevention; Primary Prevention
PubMed: 38940099
DOI: 10.26444/aaem/190438 -
Frontiers in Bioscience (Landmark... Jun 2024Neuroinflammation has emerged as a shared molecular mechanism in epilepsy and cognitive impairment, offering new insights into the complex interplay between immune... (Review)
Review
Neuroinflammation has emerged as a shared molecular mechanism in epilepsy and cognitive impairment, offering new insights into the complex interplay between immune responses and brain function. Evidence reveals involvement of High mobility group box 1 (HMGB1) in blood-brain barrier disruption and correlations with epilepsy severity and drug resistance. While anti-inflammatory treatments show promise, translating these discoveries faces challenges in elucidating mechanisms and developing reliable biomarkers. However, strategically targeting neuroinflammation and HMGB1-mediated inflammation holds therapeutic potential. This review synthesises knowledge on HMGB1 and related biomarkers in epilepsy and cognitive impairment to shape future research and treatments targeting these intricate inflammatory processes.
Topics: HMGB1 Protein; Humans; Epilepsy; Cognitive Dysfunction; Neuroinflammatory Diseases; Animals; Blood-Brain Barrier; Biomarkers; Translational Research, Biomedical; Inflammation
PubMed: 38940048
DOI: 10.31083/j.fbl2906229 -
Infectious Disorders Drug Targets Jun 2024The Bruton tyrosine kinase (BTK), an important element for the production of several inflammatory cytokines, may play a role in the pathogenesis of COVID-19. The aim of...
OBJECTIVES
The Bruton tyrosine kinase (BTK), an important element for the production of several inflammatory cytokines, may play a role in the pathogenesis of COVID-19. The aim of this study was to investigate the level of BTK gene expression in COVID-19 cases based on the severity and the outcome of the disease.
METHODS
In this study, 33 hospitalized patients with COVID-19 were recruited and were divided into two groups based on the severity of the disease: "mild to moderate" and "severe to critical". A blood sample was taken from each patient, peripheral blood mononuclear cells (PBMCs) were extracted, and BTK gene expression was measured. The level of BTK gene expression was compared based on the demographic data, laboratory results, and the severity and outcome of the disease.
RESULTS
Among 33 patients, 22 (66.7%) were male. Nearly half of the cases had at least one underlying disease. According to the severity of the disease, 12 patients were in the "mild to moderate" group, and 21 were in the "severe to critical" group; eight (24.2%) eventually died. Age, weight, and BMI had no significant relationship with BTK expression. BTK expression was significantly lower in "severe to critical" and ICU-admitted cases and in subjects with low O2 saturation. There was no significant difference in BTK expression between cured and dead patients (p=0.117).
CONCLUSION
BTK gene expression in PBMCs had an inverse relationship with the severity of the disease of COVID-19. However, no correlation between BTK expression and disease outcome was observed.
PubMed: 38939988
DOI: 10.2174/0118715265301312240529044923 -
Annals of Surgery Jun 2024We aimed to establish global benchmark outcomes indicators for L-RPS/H67.
OBJECTIVE
We aimed to establish global benchmark outcomes indicators for L-RPS/H67.
BACKGROUND
Minimally invasive liver resections has seen an increase in uptake in recent years. Over time, challenging procedures as laparoscopic right posterior sectionectomies (L-RPS)/H67 are also increasingly adopted.
METHODS
This is a post hoc analysis of a multicenter database of 854 patients undergoing minimally invasive RPS (MI-RPS) in 57 international centers in 4 continents between 2015 and 2021. There were 651 pure L-RPS and 160 robotic RPS (R-RPS). Sixteen outcome indicators of low-risk L-RPS cases were selected to establish benchmark cutoffs. The 75th percentile of individual center medians for a given outcome indicator was set as the benchmark cutoff.
RESULTS
There were 573 L-RPS/H67 performed in 43 expert centers, of which 254 L-RPS/H67 (44.3%) cases qualified as low risk benchmark cases. The benchmark outcomes established for operation time, open conversion rate, blood loss ≥500 mL, blood transfusion rate, postoperative morbidity, major morbidity, 90-day mortality and textbook outcome after L-RPS were 350.8 minutes, 12.5%, 53.8%, 22.9%, 23.8%, 2.8%, 0% and 4% respectively.
CONCLUSIONS
The present study established the first global benchmark values for L-RPS/H6/7. The benchmark provided an up-to-date reference of best achievable outcomes for surgical auditing and benchmarking.
PubMed: 38939972
DOI: 10.1097/SLA.0000000000006418 -
JBMR Plus Jul 2024Previous studies have demonstrated that the administration of zoledronic acid (ZOL) once yearly for 3 years or once over 3 years, yields similar antifracture efficacy....
Previous studies have demonstrated that the administration of zoledronic acid (ZOL) once yearly for 3 years or once over 3 years, yields similar antifracture efficacy. Bone turnover markers can predict the antifracture efficacy of antiresorptive agents, with procollagen type 1 N-terminal propeptide (P1NP) being the most useful marker. In this retrospective cohort study, we explored the effects of intravenous dosing of ZOL guided by serum (S)-P1NP assessment on bone mineral density (BMD) and fractures. Consenting patients ( = 202, mean age 68.2 years) with osteoporosis were treated with ZOL for an average of 4.4 (range 2-8) years. S-P1NP and BMD were measured at baseline and every 1-2 years. We assessed the number of subsequent vertebral and nonvertebral fractures in the 2-year time periods. The number of patients assessed was 202, 147, 69, and 29 at years 1-2, 3-4, 5-6, and 7-8, respectively. A new ZOL infusion was given if S-P1NP exhibited values above 35 μg/L. BMD increased by 6.2% (SD 4.0) over the first 2 years and stabilized in years 2-8 ( <.05). Median S-P1NP exhibited an initial reduction from 58.0 to 31.3 μg/L at year 2 and then increased to 39.0 μg/L at years 7-8. Compared with fractures observed in the last 2 years before baseline, fracture rates exhibited consistent reductions, for vertebral fractures odds ratio (OR) [95% confidence interval] = 0.61 [0.47, 0.80], <.001 and for nonvertebral fractures OR = 0.23 [0.18, 0.31], <.001. In conclusion, intermittent dosing of intravenous ZOL based on the assessment of S-P1NP with cut-off at 35 μg/L resulted in an initial increase followed by a stable BMD, suppression of S-P1NP, and stable reduction of fractures for 8 years. Only 39% of patients needed more than one infusion. This approach reduces healthcare costs and might also reduce the risk of rare side effects such as osteonecrosis of the jaw and atypical femoral fracture.
PubMed: 38939827
DOI: 10.1093/jbmrpl/ziae072 -
Journal of Arrhythmia Jun 2024Remote monitoring (RM) of cardiac implantable electrical devices (CIEDs) can detect various events early. However, the diagnostic ability of CIEDs has not been...
BACKGROUND
Remote monitoring (RM) of cardiac implantable electrical devices (CIEDs) can detect various events early. However, the diagnostic ability of CIEDs has not been sufficient, especially for lead failure. The first notification of lead failure was almost noise events, which were detected as arrhythmia by the CIED. A human must analyze the intracardiac electrogram to accurately detect lead failure. However, the number of arrhythmic events is too large for human analysis. Artificial intelligence (AI) seems to be helpful in the early and accurate detection of lead failure before human analysis.
OBJECTIVE
To test whether a neural network can be trained to precisely identify noise events in the intracardiac electrogram of RM data.
METHODS
We analyzed 21 918 RM data consisting of 12 925 and 1884 Medtronic and Boston Scientific data, respectively. Among these, 153 and 52 Medtronic and Boston Scientific data, respectively, were diagnosed as noise events by human analysis. In Medtronic, 306 events, including 153 noise events and randomly selected 153 out of 12 692 nonnoise events, were analyzed in a five-fold cross-validation with a convolutional neural network. The Boston Scientific data were analyzed similarly.
RESULTS
The precision rate, recall rate, F1 score, accuracy rate, and the area under the curve were 85.8 ± 4.0%, 91.6 ± 6.7%, 88.4 ± 2.0%, 88.0 ± 2.0%, and 0.958 ± 0.021 in Medtronic and 88.4 ± 12.8%, 81.0 ± 9.3%, 84.1 ± 8.3%, 84.2 ± 8.3% and 0.928 ± 0.041 in Boston Scientific. Five-fold cross-validation with a weighted loss function could increase the recall rate.
CONCLUSIONS
AI can accurately detect noise events. AI analysis may be helpful for detecting lead failure events early and accurately.
PubMed: 38939795
DOI: 10.1002/joa3.13037