EJVES Vascular Forum 2024Acute limb ischaemia resulting from foreign body embolisation is an infrequent yet critical complication associated with vascular closure devices (VCDs). Despite the...
INTRODUCTION
Acute limb ischaemia resulting from foreign body embolisation is an infrequent yet critical complication associated with vascular closure devices (VCDs). Despite the widespread use of VCDs, rare complications such as fragment emboli pose unique challenges, necessitating heightened clinical awareness. This case report presents a case of acute limb ischaemia caused by a VCD malfunction following an endovascular procedure.
REPORT
A 70 year old male who was diagnosed with a severe claudication of the lower extremity (Rutherford III) due to right common iliac stenosis, underwent angioplasty using a FemoSeal (Terumo Ltd., Surrey, UK) to close the right femoral artery access. Two weeks later, the patient presented with acute lower limb ischaemia due to a right popliteal-tibial occlusion. Emergency surgical thrombo-embolectomy was successfully performed from a medial popliteal approach, and the thrombus, which contained a polymer disc from the VCD at its distal end, was completely removed.
DISCUSSION
Despite VCDs being proven safe and efficient, rare complications such as fragment emboli can occur, and physicians should be aware of the possible delayed onset of symptoms. Moreover, the radiolucent nature of the polymer disc in a FemoSeal complicates diagnostic imaging. While endovascular approaches exist, open surgery is a safe and effective strategy for retrieving fragments and treating the patient in acute limb ischaemia cases.
CONCLUSION
Physicians should remain vigilant for embolic risks associated with vascular closure devices, even with suitable anatomy and following guidelines, especially considering the trend toward early ambulation and discharge.
PubMed: 38884075
DOI: 10.1016/j.ejvsvf.2024.05.006 -
Cureus May 2024The Amplatzer Vascular Plug (AVP) series enables precise positioning and high migration resistance, allowing embolization in short segments; however, inadequate...
INTRODUCTION
The Amplatzer Vascular Plug (AVP) series enables precise positioning and high migration resistance, allowing embolization in short segments; however, inadequate embolization or recanalization may occasionally occur. We hypothesized that leaks may occur when AVPs are implanted in vessels with irregular lumen due to insufficient adherence to the vessel. This hypothesis was tested by experiments with a vascular model. We employed a coil packing technique between the AVP lobes to embolize internal iliac arteries with an irregular lumen.
METHODS
Saline was injected through the Y-shaped glass tubes of the stenotic and the smooth model (without stenotic lesion), and the amount of leakage was measured when the AVP was deployed. The feasibility and effectiveness of filling coils between the lobes of AVP II were evaluated. A total of 11 cases were retrospectively reviewed using this technique for internal iliac artery embolization prior to endovascular aortic repair.
RESULTS
The amount of leakage was significantly higher in the presence of stenotic lesions. Insertion of a 2.2 F microcatheter from the side of the proximal lobe of AVP II and filling of coils was achieved in all 11 cases. Follow-up contrast-enhanced CT showed no recanalization, leakage, or other obvious complications.
CONCLUSION
Coil packing technique around Amplatzer Vascular Plugs could be an effective method and a reliable option for arterial embolization, especially in vessels with irregular lumens.
PubMed: 38883083
DOI: 10.7759/cureus.60469 -
Journal of Neurosurgery. Pediatrics Jun 2024During the COVID-19 pandemic, the authors' institution managed ventriculoatrial (VA) shunt complications in 2 teenage patients in close proximity to a symptomatic...
OBJECTIVE
During the COVID-19 pandemic, the authors' institution managed ventriculoatrial (VA) shunt complications in 2 teenage patients in close proximity to a symptomatic COVID-19 infection. Systemic thrombotic events are an established complication of COVID-19 infection due to a hypercoagulable state. Thrombotic complications, particularly elevated central venous pressure, can cause VA shunt failure. The true effect of COVID-19 on patients with intravascular devices is currently unknown. In this study, the authors aimed to determine if there was an association between COVID-19 infection and VA shunt failure.
METHODS
TriNetX, an aggregated electronic health record platform, was used to analyze data of more than 13 million US pediatric patients. Two matched cohorts of patients < 18 years of age with a VA shunt were defined. Group 1 (n = 311) had a positive laboratory test for COVID-19 from March 1, 2020, to March 31, 2022. Group 2 (n = 311), a control group, had any medical appointment from March 1, 2020, to March 31, 2022, and never had a positive laboratory test for COVID-19. The authors analyzed outcomes 1 year after testing positive for COVID-19 in group 1, and after the medical appointment in group 2. Outcomes included shunt complications, shunt revisions or replacements, and thromboembolic complications. To protect patient privacy, individual results of fewer than 10 patients are not specified in TriNetX.
RESULTS
Group 1 had a greater odds of mechanical shunt complication than group 2 (20% vs 4%, OR 5.71, 95% CI 3.07-10.62). Group 1 had a greater odds of shunt reoperation than group 2 (11% vs < 3%, OR > 3.7, 95% CI 1.72-7.62). There were 1-10 patients in group 1 (≤ 3% of group 1) who experienced a thromboembolism due to the shunt, compared with no patients in group 2 who had a thromboembolism due to the shunt.
CONCLUSIONS
This analysis demonstrates an association of shunt complications, reoperations, and thromboembolic events in patients with VA shunts following COVID-19 infection.
PubMed: 38875726
DOI: 10.3171/2024.4.PEDS23517 -
Acta Neurochirurgica Jun 2024The management of perioperative venous thrombembolism (VTE) prophylaxis is highly variable between neurosurgical departments and general guidelines are missing. The main...
BACKGROUND
The management of perioperative venous thrombembolism (VTE) prophylaxis is highly variable between neurosurgical departments and general guidelines are missing. The main issue in debate are the dose and initiation time of pharmacologic VTE prevention to balance the risk of VTE-based morbidity and potentially life-threatening bleeding. Mechanical VTE prophylaxis with intermittend pneumatic compression (IPC), however, is established in only a few neurosurgical hospitals, and its efficacy has not yet been demonstrated. The objective of the present study was to analyze the risk of VTE before and after the implementation of IPC devices during elective neurosurgical procedures.
METHODS
All elective surgeries performed at our neurosurgical department between 01/2018-08/2022 were investigated regarding the occurrence of VTE. The VTE risk and associated mortality were compared between groups: (1) only chemoprophylaxis (CHEMO; surgeries 01/2018-04/2020) and (2) IPC and chemoprophylaxis (IPC; surgeries 04/2020-08/2022). Furthermore, general patient and disease characteristics as well as duration of hospitalization were evaluated and compared to the VTE risk.
RESULTS
VTE occurred after 38 elective procedures among > 12.000 surgeries. The number of VTEs significantly differed between groups with an incidence of 31/6663 (0.47%) in the CHEMO group and 7/6688 (0.1%) events in the IPC group. In both groups, patients with malignant brain tumors represented the largest proportion of patients, while VTEs in benign tumors occurred only in the CHEMO group.
CONCLUSION
The use of combined mechanical and pharmacologic VTE prophylaxis can significantly reduce the risk of postoperative thromboembolism after neurosurgical procedures and, therefore, reduce mortality and morbidity.
Topics: Humans; Neurosurgical Procedures; Venous Thromboembolism; Female; Male; Middle Aged; Intermittent Pneumatic Compression Devices; Aged; Adult; Postoperative Complications; Retrospective Studies; Elective Surgical Procedures; Anticoagulants; Risk Factors
PubMed: 38874608
DOI: 10.1007/s00701-024-06129-4 -
Interventional Neuroradiology : Journal... Jun 2024Radial arterial access has gained interest for neurovascular procedures in recent years. Although there are no randomized control trials for neurointervention procedures...
BACKGROUND
Radial arterial access has gained interest for neurovascular procedures in recent years. Although there are no randomized control trials for neurointervention procedures using radial access, there is growing literature demonstrating its feasibility and favorable outcomes. Equipment technical improvements, like the recently introduced BENCHMARK™ BMX®81 System, have made radial navigation safer, with improved maneuverability and support for a variety of procedures. We present a multicenter case series highlighting our institutional radial access experience comparing the BMX®81 with alternative catheters.
METHODS
Multicenter retrospective cohort study of 80 patients who underwent neurovascular procedures through a radial approach. In half of the cases a BENCHMARK™ BMX®81 System was used. The comparison group consisted of the BENCHMARK™071 and 96, Neuron MAX®088 and BALLAST™ systems. Procedures included endovascular thrombectomy, carotid and brachiocephalic artery stenting, middle meningeal artery embolization, flow diverter stenting, vertebral artery sacrifice, aneurysm coiling, and WEB™ device deployment.
RESULTS
In our series, the BMX®81 was successful in the navigation of the anatomy to the target location in 95% of cases. No radial access or BMX®81 related complications were identified. There was no significant difference in fluoroscopy time between the BMX81 and the comparison group. Four patients in the comparison group had catheter-related complications due to vasospasm. Eighty-six percent of BMX®81 cases had satisfactory outcomes and no technical difficulties. The remainder presented technical difficulties, but none of these were considered secondary to the puncture site or support structure.
CONCLUSIONS
The BENCHMARK™ BMX®81 System is a recently developed guiding catheter which has design and size features supporting radial access for a variety of neurovascular interventions. Early multicenter experience highlights the ease of use and versatility of this new catheter as an alternative to transfemoral access as well as other catheters used for radial access.
PubMed: 38874547
DOI: 10.1177/15910199241261756 -
The American Journal of Cardiology Jun 2024This analysis aimed to estimate 30-day episode care costs associated with 3 contemporary endovascular therapies indicated for treatment of pulmonary embolism (PE)....
This analysis aimed to estimate 30-day episode care costs associated with 3 contemporary endovascular therapies indicated for treatment of pulmonary embolism (PE). Systematic literature review was used to identify clinical research reporting costs associated with invasive PE care and outcomes for ultrasound-accelerated thrombolysis (USAT), continuous aspiration mechanical thrombectomy (CAMT), and volume-controlled-aspiration mechanical thrombectomy (VAMT). Total episode variable care costs were defined as the sum of device costs, variable acute care costs, and contingent costs. Variable acute care costs were estimated using methodology sensitive to periprocedural and post-procedural resource allocation unique to the 3 therapies. Contingent costs included expense for thrombolytics, post-procedure bleeding events, and readmissions through 30 days. Through February 28, 2023, 70 sources were identified and used to inform estimates of 30-day total episode variable costs. Device costs for USAT, CAMT, and VAMT were the most expensive single component of total episode variable costs, estimated at $5,965, $10,279, and $11,901, respectively. Costs associated with catheterization suite utilization, intensive care, and hospital length of stay, along with contingent costs, were important drivers of total episode costs. Total episode variable care costs through 30-days were $19,146, $20,938, and $17,290 for USAT, CAMT, and VAMT, respectively. In conclusion, estimated total episode care costs following invasive treatment for PE are heavily influenced by device expense, in-hospital care, and post-acute care complications. Regardless of device cost, strategies that avoid thrombolytics, reduce the need for ICU care, shorten length of stay, and reduce post-procedure bleeding and 30-day readmissions contributed to the lowest episode costs.
PubMed: 38871160
DOI: 10.1016/j.amjcard.2024.06.002 -
European Heart Journal Supplements :... Apr 2024Implantable cardiac devices have shown that atrial fibrillation (AF) is more frequent than previously assumed, with subclinical, asymptomatic, self-limiting...
Implantable cardiac devices have shown that atrial fibrillation (AF) is more frequent than previously assumed, with subclinical, asymptomatic, self-limiting manifestations called atrial high-rate events (AHREs) or subclinical AF. The clinical significance and correct therapeutic management of these episodes of subclinical AF is less well defined than in the case of clinically manifest AF. Two important randomized studies on the topic have recently been published, NOAH-AFNET 6 and ARTESIA, which, however, have not definitively clarified the topic. In patients with AHRE or subclinical AF, the average thrombo-embolic risk is lower than that in patients with clinically manifest AF and is ∼1%. For this reason, in these patients, the possibility that the benefit of anticoagulant therapy is overshadowed by the risk of bleeding is very high. Therefore, while waiting for new tools that allow a better stratification of low-risk patients, we must rely on individual clinical evaluation and overcome the qualitative dichotomy (AHRE yes vs. AHRE no), preferring instead an approach that is as quantitative as possible and takes into account the number of episodes, their duration, and the patient's CHADSVASC score, before deciding, in each individual case, whether or not to use anticoagulant therapy.
PubMed: 38867861
DOI: 10.1093/eurheartjsupp/suae029 -
JACC. Cardiovascular Interventions Jun 2024
Topics: Humans; Embolic Protection Devices; Intracranial Embolism; Treatment Outcome; Risk Factors; Risk Assessment; Endovascular Procedures
PubMed: 38866461
DOI: 10.1016/j.jcin.2024.04.029 -
JACC. Cardiovascular Interventions Jun 2024
Topics: Humans; Embolic Protection Devices; Intracranial Embolism; Treatment Outcome; Risk Factors; Risk Assessment; Endovascular Procedures; Prosthesis Design
PubMed: 38866460
DOI: 10.1016/j.jcin.2024.04.016 -
Neurosurgery Jun 2024Endovascular treatment of cerebral aneurysms has tremendously advanced over the past decades. Nevertheless, aneurysm residual and recurrence remain challenges after...
Open Microsurgical Cerebral Aneurysm Treatment After Failed Endovascular Therapy: An Evaluation of Aneurysm Treatment Frequencies in All Neurovascular Centers Across Austria and the Czech Republic Over 20 Years.
BACKGROUND AND OBJECTIVES
Endovascular treatment of cerebral aneurysms has tremendously advanced over the past decades. Nevertheless, aneurysm residual and recurrence remain challenges after embolization. The objective of this study was to elucidate the portion of embolized aneurysms requiring open surgery and evaluate whether newer endovascular treatments have changed the need for open surgery after failed embolization.
METHODS
All 15 cerebrovascular centers in Austria and the Czech Republic provided overall aneurysm treatment frequency data and retrospectively reviewed consecutive cerebral aneurysms treated with open surgical treatment after failure of embolization from 2000 to 2022. All endovascular modalities were included.
RESULTS
On average, 1362 aneurysms were treated annually in the 2 countries. The incidence increased from 0.006% in 2005 to 0.008% in 2020 in the overall population. Open surgery after failed endovascular intervention was necessary in 128 aneurysms (0.8%), a proportion that remained constant over time. Subarachnoid hemorrhage was the initial presentation in 70.3% of aneurysms. The most common location was the anterior communicating artery region (40.6%), followed by the middle cerebral artery (25.0%). The median diameter was 6 mm (2-32). Initial endovascular treatment included coiling (107 aneurysms), balloon-assist (10), stent-assist (4), intrasaccular device (3), flow diversion (2), and others (2). Complete occlusion after initial embolization was recorded in 40.6%. Seventy-one percent of aneurysms were operated within 3 years after embolization. In 7%, the indication for surgery was (re-)rupture and, in 88.3%, reperfusion. Device removal was performed in 16.4%. Symptomatic intraoperative and postoperative complications occurred in 10.2%. Complete aneurysm occlusion after open surgery was achieved in 94%.
CONCLUSION
Open surgery remains a rare indication for cerebral aneurysms after failed endovascular embolization even in the age of novel endovascular technology, such as flow diverters and intrasaccular devices. Regardless, it is mostly performed for ruptured aneurysms initially treated with primary coiling that are in the anterior circulation.
PubMed: 38864626
DOI: 10.1227/neu.0000000000003040