JACC. Cardiovascular Interventions Jun 2024
Topics: Humans; Embolic Protection Devices; Intracranial Embolism; Treatment Outcome; Risk Factors; Risk Assessment; Endovascular Procedures; Prosthesis Design
PubMed: 38866460
DOI: 10.1016/j.jcin.2024.04.016 -
Neurosurgery Jun 2024Endovascular treatment of cerebral aneurysms has tremendously advanced over the past decades. Nevertheless, aneurysm residual and recurrence remain challenges after...
Open Microsurgical Cerebral Aneurysm Treatment After Failed Endovascular Therapy: An Evaluation of Aneurysm Treatment Frequencies in All Neurovascular Centers Across Austria and the Czech Republic Over 20 Years.
BACKGROUND AND OBJECTIVES
Endovascular treatment of cerebral aneurysms has tremendously advanced over the past decades. Nevertheless, aneurysm residual and recurrence remain challenges after embolization. The objective of this study was to elucidate the portion of embolized aneurysms requiring open surgery and evaluate whether newer endovascular treatments have changed the need for open surgery after failed embolization.
METHODS
All 15 cerebrovascular centers in Austria and the Czech Republic provided overall aneurysm treatment frequency data and retrospectively reviewed consecutive cerebral aneurysms treated with open surgical treatment after failure of embolization from 2000 to 2022. All endovascular modalities were included.
RESULTS
On average, 1362 aneurysms were treated annually in the 2 countries. The incidence increased from 0.006% in 2005 to 0.008% in 2020 in the overall population. Open surgery after failed endovascular intervention was necessary in 128 aneurysms (0.8%), a proportion that remained constant over time. Subarachnoid hemorrhage was the initial presentation in 70.3% of aneurysms. The most common location was the anterior communicating artery region (40.6%), followed by the middle cerebral artery (25.0%). The median diameter was 6 mm (2-32). Initial endovascular treatment included coiling (107 aneurysms), balloon-assist (10), stent-assist (4), intrasaccular device (3), flow diversion (2), and others (2). Complete occlusion after initial embolization was recorded in 40.6%. Seventy-one percent of aneurysms were operated within 3 years after embolization. In 7%, the indication for surgery was (re-)rupture and, in 88.3%, reperfusion. Device removal was performed in 16.4%. Symptomatic intraoperative and postoperative complications occurred in 10.2%. Complete aneurysm occlusion after open surgery was achieved in 94%.
CONCLUSION
Open surgery remains a rare indication for cerebral aneurysms after failed endovascular embolization even in the age of novel endovascular technology, such as flow diverters and intrasaccular devices. Regardless, it is mostly performed for ruptured aneurysms initially treated with primary coiling that are in the anterior circulation.
PubMed: 38864626
DOI: 10.1227/neu.0000000000003040 -
Journal of Neurointerventional Surgery Jun 2024Transcirculation catheterization, also known as the retrograde approach, involves the navigation of a catheter or other endovascular device from one arterial circulation...
Transcirculation catheterization, also known as the retrograde approach, involves the navigation of a catheter or other endovascular device from one arterial circulation to the other (right to left, or anterior to posterior).1-4 We present a case of a complex vertebrobasilar junction aneurysm previously treated by bilateral vertebral artery deconstruction, precluding antegrade access (video 1). Following the creation of a protective occipital artery to posterior inferior cerebellar artery (PICA) bypass, the patient was treated with transcirculation placement of a Pipeline embolization device (PED).5-9 The right internal carotid artery was accessed with a guide catheter using a transradial approach. The microwire-microcatheter combination was then tracked through the right posterior communicating artery, down the basilar trunk, and to the left PICA. The PED was successfully deployed from the left vertebral artery to the mid-basilar artery. At 3-month follow-up, the aneurysm was completely obliterated. The nuances of transcirculation technique, especially for flow diversion, are discussed. (Used with permission from Barrow Neurological Institute, Phoenix, Arizona, USA.)neurintsurg;jnis-2023-021363v1/V1F1V1Video 1Transcirculation retrograde placement of a Pipeline embolization device for treatment of a vertebrobasilar junction aneurysm previously treated by bilateral vertebral artery deconstruction, precluding antegrade access.
PubMed: 38862210
DOI: 10.1136/jnis-2023-021363 -
Neurology Jul 2024Embolic strokes of undetermined source (ESUS) represent 9%-25% of all ischemic strokes. Based on the suspicion that a large proportion of cardioembolic sources remain... (Review)
Review
Embolic strokes of undetermined source (ESUS) represent 9%-25% of all ischemic strokes. Based on the suspicion that a large proportion of cardioembolic sources remain undetected among embolic stroke of undetermined source patients, it has been hypothesized that a universal approach of anticoagulation would be better than aspirin for preventing recurrent strokes. However, 4 randomized controlled trials (RCTs), with different degrees of patient selection, failed to confirm this hypothesis. In parallel, several RCTs consistently demonstrated that prolonged cardiac monitoring increased atrial fibrillation detection and anticoagulation initiation compared with usual care in patients with ESUS, and later in individuals with ischemic stroke of known cause (e.g., large or small vessel disease). However, none of these trials or subsequent meta-analyses of all available RCTs have shown a reduction in stroke recurrence associated with the use of prolonged cardiac monitoring. In this article, we review the clinical and research implications of recent RCTs of antithrombotic therapy in patients with ESUS and in high-risk populations with and without stroke, with device-detected asymptomatic atrial fibrillation.
Topics: Humans; Embolic Stroke; Anticoagulants; Atrial Fibrillation; Randomized Controlled Trials as Topic; Monitoring, Physiologic
PubMed: 38861698
DOI: 10.1212/WNL.0000000000209535 -
PloS One 2024Post-partum haemorrhage is among the main causes of (preventable) mortality for women in low-resource settings (LRSs), where, in 2017, the mortality ratio was 462 out of...
Post-partum haemorrhage is among the main causes of (preventable) mortality for women in low-resource settings (LRSs), where, in 2017, the mortality ratio was 462 out of every 100 000 live births, over 10 times higher than for high-resource settings. There are different treatments available for post-partum haemorrhage. The intrauterine balloon tamponade is a medical device that proved to be a simple and cost-effective approach. Currently, there are several balloon tamponades available, with different design and working principles. However, all these devices were designed for high-resource settings, presenting several aspects that could be inappropriate for many lower-income countries. This paper presents the results of a preclinical study aiming at informing the design, prototyping and validation of a 3D-printed intrauterine balloon tamponade concept, contributing towards the United Nation's Sustainable Development Goal 3: Good health and Well-being. Frugal engineering concepts and contextualised design techniques were applied throughout, to define the design requirements and specifications. The performance of the final prototype was validated against the requirements of the UK National Health System (NHS) technical guidelines and relevant literature, measuring the water leak and pressure drop over time, both open air and in a approximate uterus model. The resulting prototype is made up of six components, some of which are easy to retrieve, namely a water bottle, a silicone tube and an ordinary condom, while others can be manufactured locally using 3D printers, namely a modified bottle cap, a flow stopper and a valve for holding the condom in place. Validation testing bore promising results with no water or pressure leak open air, and minimal leaks in the approximate uterus model. This demonstrates that the 3D printed condom-based intrauterine balloon tamponade is performing well against the requirements and, when compared to the state of the art, it could be a more appropriate and more resilient solution to low-resource settings, as it bypasses the challenges in the supply of consumables and presents a greener option based on circular economy.
Topics: Printing, Three-Dimensional; Female; Humans; Uterine Balloon Tamponade; Equipment Design; Postpartum Hemorrhage; Condoms; Pregnancy
PubMed: 38861495
DOI: 10.1371/journal.pone.0303844 -
Methodist DeBakey Cardiovascular Journal 2024We report three cases of coronary artery aneurysm (CAA) in adults who presented with acute coronary syndrome. Two of these patients did not have traditional coronary...
We report three cases of coronary artery aneurysm (CAA) in adults who presented with acute coronary syndrome. Two of these patients did not have traditional coronary artery disease risk factors. Management of CAA poses a significant challenge to interventionalists. We discuss the etiologic mechanisms, risk factors, pathophysiology, and diagnosis using angiography, intravascular ultrasound, and coronary computed tomography. We also highlight management options, including medical therapy and catheter-based interventions such as stenting, coil embolization, stent-assisted coil embolization, and surgical exclusion.
Topics: Humans; Coronary Aneurysm; Acute Coronary Syndrome; Male; Treatment Outcome; Coronary Angiography; Middle Aged; Embolization, Therapeutic; Ultrasonography, Interventional; Female; Aged; Predictive Value of Tests; Stents; Percutaneous Coronary Intervention; Computed Tomography Angiography; Risk Factors
PubMed: 38855039
DOI: 10.14797/mdcvj.1343 -
Cureus May 2024Intrasaccular flow modification with devices like the Woven EndoBridge (WEB, MicroVention, Inc., Aliso Viejo, California, US) is an increasingly utilized endovascular...
Intrasaccular flow modification with devices like the Woven EndoBridge (WEB, MicroVention, Inc., Aliso Viejo, California, US) is an increasingly utilized endovascular treatment for bifurcation aneurysms. Among the potential complications of the procedure is branch vessel occlusion. There are no previous publications of rescue stenting for inadvertent branch vessel occlusion with the WEB device. We report two cases of rescue stenting following branch vessel occlusion after cerebral aneurysm embolization with the WEB device. In both cases, rescue stenting with a Neuroform Atlas stent Stryker, Fremont, CA, US) successfully revascularized the occluded vessel and led to good patient outcomes.
PubMed: 38854321
DOI: 10.7759/cureus.59880 -
Circulation. Cardiovascular... Jun 2024Surgery or fibrinolysis is the currently available evidence-based treatment for obstructive mechanical valve thrombus. We reported the feasibility and short-term...
BACKGROUND
Surgery or fibrinolysis is the currently available evidence-based treatment for obstructive mechanical valve thrombus. We reported the feasibility and short-term outcomes of percutaneous transcatheter therapy with cerebral embolic protection. Mid- and long-term outcomes remain unknown.
METHODS
From 2020 to 2023, 24 patients underwent percutaneous transcatheter release of stuck leaflets with cerebral embolic protection for obstructive mitral mechanical valve thrombus. The indications for the transcatheter therapy were failed fibrinolysis, contraindications for fibrinolysis, not willing for fibrinolysis, or high risk for surgery. The study participants were followed up for a median period of 344.50 (65.00-953.75) days.
RESULTS
Technical success was achieved in 91.67% (n=22) of procedures. During the follow-up, 12.50% (n=3) all-cause death, 4.17% (n=1) stroke, and 16.67% (n=4) recurrence were seen. The mean survival time free from death was 1101.48 (95% CI, 929.49-1273.47) days, stroke was 1211.38 (95% CI, 1110.40-1312.35) days, and recurrence was 907.71 (95% CI, 760.20-1055.21) days.
CONCLUSIONS
Transcatheter release of the stuck mitral mechanical valve with cerebral embolic protection is an alternative therapy with promising mid-term outcomes where surgery or fibrinolysis is not possible or in failed fibrinolysis subsets.
PubMed: 38853741
DOI: 10.1161/CIRCINTERVENTIONS.124.014044 -
The American Journal of Case Reports Jun 2024BACKGROUND The Over-the-Scope-Clip (OTSC) System is a class of endoscopic clips intended to provide improved strength and tissue capture compared to conventional...
BACKGROUND The Over-the-Scope-Clip (OTSC) System is a class of endoscopic clips intended to provide improved strength and tissue capture compared to conventional through-the-scope clips. These clips are generally safe and effective in managing many gastrointestinal conditions, with a low overall adverse event rate. Although the OTSC has been used to treat gastrointestinal bleeding and bowel perforations for many years, it often is relegated to second-line therapy and has only recently become a first-line hemostatic therapy for gastrointestinal bleeding. CASE REPORT Here, we present a unique adverse event of the OTSC causing iatrogenic ligation of the gastroduodenal artery (GDA). A 71-year-old man presented with 6 months of epigastric abdominal pain and 2 weeks of hematemesis, and was ultimately diagnosed with a bleeding duodenal ulcer. He underwent multiple endoscopic interventions to attempt to control the duodenal ulcer bleeding, including placement of the OTSC on a visible vessel. Soon after OTSC placement, he became hypotensive with recurrent hematochezia, and Interventional Radiology was consulted for endovascular management of the bleeding. Angiography showed the OTSC had been deployed across the midportion of the GDA from the duodenal lumen, effectively ligating the GDA, causing bleeding due to direct vascular injury. This bleeding was ultimately controlled with coil embolization. However, this iatrogenic ligation of the midportion of the GDA by the OTSC significantly complicated endovascular intervention to control the bleeding. CONCLUSIONS As the OTSC device becomes more commonly used in the endoscopy suite, it is important to share potential pitfalls that may be encountered in the clinical setting that impact not only endoscopists and patients, but other specialties as well.
Topics: Humans; Male; Aged; Ligation; Duodenum; Iatrogenic Disease; Surgical Instruments; Gastrointestinal Hemorrhage; Duodenal Ulcer
PubMed: 38853402
DOI: 10.12659/AJCR.943891 -
Journal of Neurointerventional Surgery Jun 2024Neuroendovascular procedures require careful and simultaneous attention to multiple devices on multiple screens. Overlooking unintended device movements can result in...
BACKGROUND
Neuroendovascular procedures require careful and simultaneous attention to multiple devices on multiple screens. Overlooking unintended device movements can result in complications. Advancements in artificial intelligence (AI) have enabled real-time notifications of device movements during procedures. We report our preliminary experience with real-time AI-assisted cerebral aneurysm coiling in humans.
METHODS
A real-time AI-assistance software (Neuro-Vascular Assist, iMed technologies, Tokyo, Japan) was used during coil embolization procedures in nine patients with an unruptured aneurysm. The AI system provided real-time notifications for 'coil marker approaching', 'guidewire movement', and 'device entry' on biplane fluoroscopic images. The efficacy, accuracy, and safety of the notifications were evaluated using video recordings.
RESULTS
The AI system functioned properly in all cases. The mean number of notifications for coil marker approaching, guidewire movement, and device entry per procedure was 20.0, 3.0, and 18.3, respectively. The overall precision and recall were 92.7% and 97.2%, respectively. Five of 26 true positive guidewire notifications (19%) resulted in adjustment of the guidewire back toward its original position, indicating the potential effectiveness of the AI system. No adverse events occurred.
CONCLUSIONS
The software was sufficiently accurate and safe in this preliminary study, suggesting its potential usefulness. To the best of our knowledge, this is the first reported use of a real-time AI system for assisting cerebral aneurysm coiling in humans. Large scale studies are warranted to validate its effectiveness. Real-time AI assistance has significant potential for future neuroendovascular therapy.
PubMed: 38849208
DOI: 10.1136/jnis-2024-021873